Relationship beyond Bankjng TENDER DOCUMENT FOR ELECTRICAL (ELECTRICAL & DATA CABELING WORK ONLY) IN BANK OF INDIA BRANCH AT SECTOR 25 PANCHKULA BANK OF INDIA, ZONAL OFFICE, S.C.O. NO. 76-82, SECTOR 31-A, CHANDIGARH - 160030 PART B: FINANCIAL BID ARCHITECTS : GURDEV GROUP OF ARCHITECTS SCO 1094-95, SECTOR 22-B, CHANDIGARH 160 022 PHONE : 0172-2712201 MOBILE : 094170-08450 LAST DATE OF SUBMISSION : 16.12.2015 Please note that Special Conditions of contract & specifications are not enclosed with this Part A however they are integral part of the tender and are strictly applicable for all bidders. It will be issued on written request from the bidders to the following address: CHIEF MANAGER (Corporate Services Deptt.), Bank of India, S.C.O. 76-82, 2 nd Floor, Zonal Office, Sector 31-A, Chandigarh 160030
S.NO 1. 2. 3. 4. Relationship beyond Bankjng RECOMMENDED MAKE TO BE USED FOR THE ELECTRICAL WORKS IN BANK OF INDIA BRANCH AT SECTOR 25 PANCHKULA DESCRIPTION MCB Change over switch Modular Switch Wires / cables(frls) MAKE/BRANDS Havell.s / L & T / MDS / Schinder. L & T /G.E MDS / MK / NorthWest Finolex / Ploy cab /Havells. 5. Ceiling fans Bajaj / Khaitan/ Crompton Greaves 6. Exhaust fans with louvers Bajaj / Khaitan/ Crompton Greaves. 7. Wall mounted fan Bajaj / Khaitan/ Crompton Greaves/ Havells. 8. 9. tube light CFL( Single Tube light fixtures ( Double Philips / Wipro/G.E. Philips / Wipro/G.E. 10. 3X36 w recessed fixture Philips / Wipro/G.E. 11. 12v, 50w halogens Philips / Wipro/G.E. 12. MCCB Havell / L & T / ABB / Schinder. 13. ELCB Havell / L & T / Schinder. 14. Telephone wire finolex/ Havell. 15. Isolator Havell's/ L & T / ABB. 16. LAN Cable (Cat 5) D-Link Digi-link 17. I/O Switch D-Link,HCL, Digi-link All Materials shall be best quality heavy section mentioned in the drawing as well as in bill of quantities and also approved by Bank / Consultant. (Tenders to be submitted by Empanelled Category Contractors of Bank of India in Chandigarh Zone only)
Relationship beyond Bankjng TENDER FOR THE ELECTRICAL WORKS IN BANK OF INDIA AT SECTOR 25 PANCHKULA B. ELECTRICAL QTY. UNIT RATE AMOUNT (RS) 1. Providing & Fixing 2" x 2 " recessed mounted LED 15 Nos. Luminaire LCTLR-36-CDL of Crompton. 2. i) Providing & Fixing 15 W LED ROUND DOWNLIGHTER 15 Nos. LCND-15-CDL of Crompton. ii) Providing & fixing ordinary tube lights 1x40W of Philips. 10 Nos. 3. (i) Providing & Fixing wall fans: Khaitan / Crompton 14 Nos. Greaves / Orient. (ii) Exhaust Fans 12 Dia: 1400 rpm 4 Nos. (Double ball bearing) Heavy duty Crompton Greaves / Phillips. iii) Providing & Fixing ceiling fans: Khaitan / Crompton 1 Nos. Greaves / Orient 4 dia. iv) Cost of modular regulators of Havells / Anchor ROMA 1 Nos. makes. 4. ELECTRICAL POINTS: Providing laying, fixing & testing of electrical points ncluding wiring from MCB s to switches, plate type switches, socket & M.S. Modular boxes with rust proof treatment size to accommodate the required nos. of switches & sockets plus circuit wiring from switches to ights/fans/fixtures etc. wherever required complete with earthing 1.00 mm2 multi strand wire in 25mm dia. Unbreakable PVC conduit ISI marked with specials under floor / wall & above false ceiling or making truff under / along work - stations including chase cutting, disposal of melba away from the site and repair of the same with cement mortar, copper conductor wires only will be used of approved make. a) Electrical wiring for single-phase split type Air- 5 Nos. Conditioning: P / F 32 Amp wiring with MCB from D/B to site of outdoor and indoor to outdoor A/C Unit, i.e. circuit wiring with 4mm sq. multi-strand PVC copper wire, earth wire with DP switches. b) Electrical wiring for 3-phase cassette type Air- NILL Nos. Conditioning: P / F 32 Amp wiring with MCB from D/B to site of outdoor and indoor to outdoor A/C Unit, i.e. circuit wiring with four runs of 10mm sq. multi-strand PVC copper wire, earth wire with isolators.
c) Electrical wiring for UPS input-output: 2 Nos P / F 32 Amp wiring with MCB 32 Amp. from D/B to the ocation of UPS/UPS room for input and output power supply (with 2 sets of 3-pin switch-socket of 15 Amp for each UPS) with 2 runs of 4mm sq. and one run of 1.5 sq. mm as earth wire multi-strand PVC copper wires, with 3-pin power pt. i.e. switch-socket. c) 15 Amp wiring with 2.5mm sq. multi strand PVC 8 Nos. copper wire & metal clad enclosure sockets & plus. d) 5 Amp plug point wiring with 1.5mm sq. multi stand 6 Nos. PVC copper wire inc. Plate switches, sockets, plugs. Etc. e) Call-bell point wiring including Ding-dong bell with 2 Nos. 1.5mm sq. multi strand PVC copper wire including plate switches, sockets, etc. f) Wall Fan, lights & exhaust fan point wiring with 1.5mm 50 Nos. sq. from D/B to switches & fittings multi strand PVC copper wire including plate switches, sockets, etc. ( For payment no. of switches shall be counted). g) Signage wiring (material & labour) - P&F of 3x4mm & 2 Nos. copper flexible wire & PVC conduiting of ISI make complete with all accessories like Saddles, bends modular switches etc. 5. UPS POINTS : P/L & testing electrical three point wiring having ndividual circuits for computers with 2.5mm2 Multistrand copper PVC wire in unbreakable PVC conduits 25mm dia wall thickness 2mm thick with specials under floor / wall & above false ceiling ncluding chase cutting, disposal of melba away from the site and repair of the same with cement mortar, ncl. Switches & socket M.S. switch boxes with rust proof treatment size to accommodate the required nos. of Modular switches, sockets etc. & plate type sockets with indicator three in one plate including earthing with 1.00 mm2 multi strand wire complete in all respect. Set of 6 amp. 4 sockets & 4 switches 15 Sets each set 6. Supplying and installation (Testing, connection & 2 No. commissioning with 2.5 sq. mm earth wire) of earth stations for computers with 600 mm x 600 mm x 3mm th. Copper plate electrode complete with 25mm dia. B Class G.I. pipe for watering including funnel, 30cm x 30cm x 30 cm masonry chamber with precasted RCC cover / C.I. cover complete with salt & charcoal filling (as per IS: 3034-1987) incl. copper strip 1 wide 4mm th. with copper base plate up to UPS cabin. 7. Providing and fixing of PVC conduit in wall floor incl. 8 Nos. Telephone wire, M.S. box and two pin telephone sockets or R.J. - 11 plates out let incl. Testing and commissioning etc. as required. 8.i) Providing & laying CAT-VI/ Lucent / D-link computer 15 Nos. networking cable in PVC conduit in floor or wall from
server room to each table with I.O. s (Socket) ii) Supplying of patch chords for computers 1m & 2m 15 Nos. ength. 9. Providing & fixing main electrical dist. Board with all electrical and generator internal connections with 10 sq.mm multi strand copper wire, which shall include the following items. i) Kit-kats 100 Amp. 3 Nos. ii) Aluminum bus bar 100 Amp. 2 Nos. iii) 100 Amps. Main switch MCCB. 1 No. iv) Change -over 63 Amps. 3-phase. 1 No. v) 3-Phase 4-way D/B TPN of Havells make with MCB,s 32 1 No. Amp and TPN s for power supply and AC s. vi) 3-Phase 4-way D/B TPN of Havells make with MCB,s 10 1 No. Amp. to 16 Amp./20 Amp./32 Amp. power supply, ights, fans. vii) 6-way single phase D/B of Havells make with MCB s 2 No. and DP switch for UPS supply to computers. viii) Making double-door powder coated M.S. Distribution 12 Sqft. board 3 x4 to accommodate the above noted electrical items. ix) MASTER SWITCHES 2 Nos. 10. CABLES : 100 Amp MCCB: 2 Nos. to be installed at the main gate of the Bank to switch off main supply for ights, power/ac s and UPS supply (output) except router, UPS s Charging lines, glow sign board. Complete wiring with 4x10 sqmm multistrand PVC copper wire for the above said MASTER SWITCHES. i) Providing & fixing main electrical cable 4- core al. 50 Mtr. cable armored from elect. pole to meter 35mm dia. ii) P/F generator wire/cable 16mm 4-core Alum. Cable. 50 Mtr. iii. Connectivity for the VSAT / leaselines (material & 2 No. abour) - P&F of 40mm PVC conduit of ISI make ncluding data cable of D-link & RJ-45, complete for connectivity. 11.i) Providing, fixing, testing and commissioning 1 sets computers 16- Ports networking switch with racks. 12. P/L copper pipe with complete insulation required for 250 Rft. i) 1.5 ton Split type A.C.s from the place of external units upto the location of inside units.
P/L copper pipe with complete insulation required for NILL Rft. 7.5/10.00 ton Cassette type / ductable A.C.s from the place of external units upto the location of inside units. ii) Providing and laying 25mm dia. PVC pipe heavy duty 200 Rft. Diplast make for drainage of water of inside units. TOTAL GRAND TOTAL = RS ---------------- Quote Discount, if any = ( - ) RS NET TOTAL = Rs (Rupees ) CONTRACTOR BANK OF INDIA