INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

Similar documents
INSTALLATION GUIDE. Greentek. Residential use only MODEL HS 3.0

INSTALLATION / OPERATION / MAINTENANCE GUIDE

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

UV-AIRE AIR PURIFYING SYSTEM

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

Installer s Manual. PCO/UV N-Duct Model

Further information: Berriman Associates Model 850P.2 Owners Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Installation Instructions

Safety, Installation and Service Manual Models 1952, 1953 & 1972

HARDWARE KIT INSTALLATION GLOVES

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

MCI. SynAIRgPURE. Owner s Manual

OWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Installation Instructions

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

IMPORTANT: SAFETY INSTRUCTIONS

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

21", 33", 45", & 61" Installation & Operation Manual

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

UV-AIRE AIR PURIFYING SYSTEM

MODEL 950C-NP-UV Installation and Owners Manual

WARRANTY. Air flow. (Please note standard off-the-shelf lamps are not compatible with this unit. Use of improper lamps will void warranty.

Troubleshooting manual for Sanuvox R+ Air Purifier

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

UNPACKING THE UNIT. Alcohol cleaning pad

EXT DUCTLESS FUME HOOD

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

INSTALLATION TEMPLATE

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

FOODSAFE IL INSTALLATION MANUAL

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Model G14SD Vapor Management System

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

WARNING Risk of property damage, injury, or death.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

EXT HEPA/CARBON FUME HOOD

SLIMZONE CLASSIC /

Model 8144NC Fresh Air Ventilator

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

CAUTION: Read manual carefully for proper procedures and operation.

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

User s Manual and Operating Instructions

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.

Automatic Emergency Light

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Miracle State Of The Art Air Filtration System!

Cincinnati, OH USA

1000 Watt Pure Sine Wave Power Inverter, Users Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Bottom Loading Water Dispenser

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

FD Conveyor for FD 260 Tabber

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

ESE Series Cast Iron Sewage Pumps

Before replacing LED light ensure the unit is switched off, when you want to

Source Capture Air Purification System

Power Inverter 400 MW Owner s Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual

VCM LAMINAR FLOW HOOD VERTICAL

SUBMERSIBLE MINI-PUMP

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Instruction Manual. Fudge Puppy Display Case

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

HEPA AIR FILTRATION SYSTEM

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

READ AND SAVE THESE INSTRUCTIONS FOR THE DUCTSTAT TEMPERATURE SENSITIVE SWITCH

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

Installation Instructions

F111U In-Ceiling Media Air Cleaner with Ultraviolet Air Treatment System

Installation Instructions Electric Heaters 5 20 kw

LESTRONIC II BATTERY CHARGER MODEL 19740

Installation, Operating and Maintenance instructions for Hydro-Air pumps

Environmental Series Air Curtains

Transcription:

INSTALLATION, MAINTENANCE & OPERATION GUIDE MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER ITEM # 101275 Sanuvair S 300-120V EN

SAFETY CONSIDERATIONS Installation and servicing or equipment can be hazardous. Only trained and qualified service personnel should install, repair, or service equipment. Untrained personnel can perform basic maintenance functions such as changing lamps and filters. All other operations should be performed by trained service personnel. When working on equipment, observe precautions in the literature, tags and labels attached to the unit or accessory, and other safety precautions that may apply. Follow all safety codes.wear safety glasses and work gloves WARNING Before installing the Sanuvair S300 HEPA/UV Purifier or performing maintenance or service on the air purifier, disconnect power cord from the unit. Never expose eyes or skin to ultra-violet light from any source. The Sanuvair S300 must be unplugged before performing maintenance or service. Personal injury may result. Do not touch lamp glass without gloves. Reduced performance of lamp may result. Clean lamp after handling. La lampe UV contient une faible quantité de mercure. Si la lampe se brise, veuillez nettoyer et en disposer Lamp contains a small quantity of mercury. If a lamp breaks, clean and dispose of with care. Use only specified replacement Lamps with your Sanuvox Purifier. Use of an incorrect Lamp can result in damage to the Purifier and/or Lamp. UV rays may destroy certain type of filters (polymer or plastic), please keep units away from shinning directly on plastic. NOTICE UV lamp can be disposed/recycle after use as for any other fluorescent bulb.

LIMITED PARTS WARRANTY THREE-YEAR WARRANTY This SANUVOX TECHNOLOGIES INC. product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of 3 years from the date of original installation and for a period of 3 years (2 years for commercial) for the UV Lamp. A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty TABLE OF CONTENTS 1. GETTING STARTED 1.1 Unpacking and inspection 3 1.2 Technical data 4 2. INSTALLATION GUIDE 2.1 Planning the installation 5 2.2 Type of installation: Return to Return 6 2.3 Type of installation: Stand-Alone 6 2.4 Installing the unit 7 2.5 Installing the UV Lamp 10 3. OWNER S OPERATION GUIDE 3.1 General Operating Information 11 4. MAINTENANCE GUIDE 4.1 Changing filters 12 4.2 Cleaning unit 12 4.3 Troubleshooting 12 4.4 Electrical Wiring Diagram 12 1.1. UNPACKING AND INSPECTION BOX CONTENT INCLUDES: Sanuvair S300 HEPA/UV AIR PURIFIER Power cord, 5 FT Plenum seal, 7.5 FT Screws, (16) 8 x 32 x 1/2" Template Ultraviolet UVC/UVV Lamp J Type 10.5" (266.7 mm) Pre-Filter HEPA Filter SANUVOX - MODEL SANUVAIR S300-3

1.2. TECHNICAL DATA SPECIFICATIONS MODEL SANUVAIR S300 Filtration Stage 1 Filtration Stage 2 Weight Plenum Mount Port Openings Collar Mount Port Openings Installation type Electrical Supply Power Consumption Certification Air flow data UV Lamp Prefilter HEPA filter 33 Lbs. (15kg) 16" x 3.5" (406mm x 89mm) 8" (203mm) Round* Plenum, Floor Mount* or Wall Mount** 120 VAC @ 60 Hz 270 W C CSA US 220-300 CFM Proprietary UV-C/UV-V J Lamp DIMENSIONS AND CLEARANCE INSTALLATION RETURN AIR PLENUM INSTALLATION 31" 795 mm Front View Side View - Clearance Stage 1 Back View 4" 97 mm 30" 770 mm * Installation requires inlet / outlet 8" round collars (sold in pairs). Part# MSCCOL1 Stage 2 ** Installation requires inlet / outlet louvers (sold individually). Part# MSCLOU1 13" 327 mm 12" 305 mm 17" 432 mm IMPORTANT INFORMATION Sanuvox Technologies Inc. reserves the right to modify the product without prior notice. Please consult local authorities as to whether the installation requires the services of a certified technician or electrician. RETURN AIR PLENUM AND STAND ALONE INSTALLATIONS* WITH COLLAR MOUNT KIT Front View 8" 203 mm Side View - Clearance Back View Power Connection 4" 97 mm 31" 795 mm Stage 1 30" 770 mm Stage 2 13" 327 mm 12" 305 mm 17" 432 mm 4 - SANUVOX - MODEL SANUVAIR S300

2.1 PLANNING THE INSTALLATION SPECIAL CONSIDERATION FOR INTEGRATED SYSTEM INSTALLATION Verify clearance on the ductwork to mount the unit using the Forced Air Heating/Cooling system Respect the Minimum clearance requirements for maintenance and service Electrical power requirements Interaction between the HEPA/UV air purifier unit and other mechanical devices. The HEPA/UV air purifier is a versatile appliance with multiple installations configuration. It is recommended to take your time in planning the installation. A number of installations follow for HEPA/UV air purifier applications: Return duct to Return duct integrated with the forced air HVAC system. Central draw points using a dedicated duct system. Consult Sanuvox for other special applications. 2.2 TYPE OF INSTALLATION: RETURN TO RETURN DUCTING FLAIR SYSTEM INSTALLATION The HEPA/UV air purifier system is designed to install directly onto the return air plenum of the HVAC system. This installation eliminates the need to externally duct the HEPA/UV air purifier to the plenum system. With this installation, it is recommended that you run the fan on your forced air system continuously to maximize its cleaning ability. TIPS TO INSTALLER DUCTING FLAIR SYSTEM (MOUNTED ON DUCT) Return Air Plenum To living space OPTIONAL COLLAR SYSTEM (MOUNTED ON WALL) The HEPA/UV air purifier does not replace the filter from the HVAC system. Regular maintenance of this filter is necessary for proper performance of the system. Forced Air Heating/Cooling System Return Air Plenum To living space OPTIONAL MOUNTING COLLAR SYSTEM INSTALLATION Using Part Number: Collars1, the HEPA/UV air purifier can be converted to use 8 inch round collars for applications that require ducting. The kit includes two, 8 inch round collars, two mounting brackets for wall or floor mounting, installation guide and fasteners. Forced Air Heating/Cooling System INSTALLATION SHOULD BE PERFORMED BY A CERTIFIED PROFESSIONAL. Consult your HVAC product manufacturer if the usage of this product will affect the performance of your forced air heating/cooling system. SANUVOX - MODEL SANUVAIR S300-5

2.3 TYPES OF INSTALLATION: STAND ALONE STAND ALONE ATTIC INSTALLATION Ideal for homes without a forced air HVAC system. Allows for air filtration and circulation throughout the home. The HEPA/UV system must be operated continuously whenever a part of all the system is located in an unconditioned space below freezing (0ºC, 32ºF) to prevent condensation in the ductwork. STAND ALONE BASEMENT INSTALLATION Ducting will usually consist of one return duct (with grille) from one side of the home, and one supply duct with diffuser at the opposite end of the home. Stand Alone Wall Mount The Sanuvox Sanuvair S300 can be wall mounted using optional inlet and outlet louvers (Part # MSCLOU1) that attach to the collar mount port openings on the top and bottom of the unit. 6 - SANUVOX - MODEL SANUVAIR S300

2.4 INSTALLING THE UNIT STEP-BY-STEP INSTALLATION Steps involved in the preparation of the return plenum mount system: TOOLS REQUIRED Phillips #2 or Robertson #1 screwdriver 3/32" drill bit Tin snips or metal shear Power drill STEP 1: PREPARING RETURN AIR PLENUM Find a location that satisfies both service and maintenance requirements. Cut holes as illustrated below. STEP 2: PREPARING DUCTING FLAIRS Remove the door and filters and proceed to cut the insulation as illustrated below. LOCATION Return side connection is to be installed after the last branch on the return air plenum and a minimum of 2 linear feet from the furnace. A 5-foot power cord is supplied with the unit. A 120VAC outlet needs to be supplied. Figure 2.2a - Cut insulation along the inside edge of both of the inlet and outlet ports to remove the insulation from the port openings. Figure 2.1a - Tape template to return air plenum. Cut opening with metal shears and pre-drill for the securing screws. Figure 2.2b - One cut permits the clean removal of the insulation piece. Figure 2.1b - Remove template. Figure 2.2c - The unit should look like this when the foam piece is removed. SANUVOX - MODEL SANUVAIR S300-7

2.4 INSTALLING THE UNIT (Continued) TIPS TO INSTALLER Always consult your national and local regulations, building and safety codes to whether the installation of electrical products requires the services of a certified technician or electrician. STEP 2: (Continued) Cut the four metal tabs to release the mounting flairs for the inlet and outlet ports. Removing the filters from the unit will facilitate the installation. DUCTING FLAIRS MOUNTING SYSTEM The Sanuvox Sanuvair S300 HEPA/ UV air purifier system is designed for single person installation. The Sanuvox Ducting Flairs are integrated within the unit and will save installation time and effort. Once the holes are made in the main return duct and the unit is aligned, unfold the Ducting Flairs and screw the unit in place. Figure 2.2d Figure 2.2e Figure 2.2h - Apply plenum seal tape all around both openings on the back of the unit. Figure 2.2i Figure 2.2f Figure 2.2j - Bend tabs outward 90 degrees. Figure 2.2g 8 - SANUVOX - MODEL SANUVAIR S300

2.4 INSTALLING THE UNIT (Continued) TIPS TO INSTALLER It is recommended that the filtration unit have a devoted receptacle with 115V. It is not recommended to connect unit with an extension cord. If no receptacle is available please call an electrical contractor to have one installed. STEP 3: Mount Hepa MAKE SURE TO INSTALL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is located on the unit s motor plate. Figure 2.3c - Install unit using all supplied fastening hardware. STEP 4: Finishing Figure 2.3a - Align unit into place. Stage 1: Pre-Filter Stage 2: HEPA Filter Figure 2.4a - Remove protective plastic covers from all filters and install in their proper location. Figure 2.3b - Unfold the ducting flairs to sandwich the return air plenum between the ducting flair and the filtration unit. Figure 2.4b - Replace door and insert power cord into the receptacle of the HEPA and the other end into a wall outlet. SANUVOX - MODEL SANUVAIR S300-9

2.5 UV LAMP INSTALLATION STEP 1: The UV Lamp is packaged in the filter section of the Sanuvair S300. Remove the UV lamp from the packaging material. The lamp is fragile, use extreme care. Do not touch the glass on the lamp with bare hands. Use the enclosed gloves when handling the lamp. Handle lamp from the ceramic ends. STEP 2: Remove the screws holding the front plate of the Sanuvair S300 to access the clamp assembly. STEP 3: Position lamp inside the aluminum enclosure. Route 4-pronged end of lamp through clamp. Clamp is tightened by moving lever perpendicular to the clamp. Connect the female plug to the lamp. The plug fits in one direction only. If the plug will not connect to the lamp, turn the plug 90 degrees. STEP 4: Replace the front plate with the screws removed in (2) above. 10 - SANUVOX - MODEL SANUVAIR S300

OWNER S OPERATION GUIDE 3. GENERAL OPERATING INFORMATION DOOR SWITCH MODE SELECTOR II I FUNCTION The HEPA/UV air purifier is comprised of a ventilator, speed selection switch, 2 stages of filtration and the cabinet enclosure system. The ventilator pulls air through the prefilter and pushes the same air through the HEPA filter which removes 99.97% of particles that are 0.3μm or larger in size. OPERATION MODE OPTIONS The unit features two speeds of operation. The speed selection switch is located on the front of the motor assembly. At lowest speed the unit will provide 220 CFM of clean air while at highest speed, the unit will provide 300 CFM of clean air. It is recommended that the unit be operated on the highest speed at all times to maximize the benefits of the HEPA/UV air purifier. The Sanuvair S300 HEPA/UV Purifier is designed to kill bacteria, viruses, odor causing mold and fungus as well as chemical odors and VOC's that pass through the unit. The ultra-violet band light inhibits and kills mold, fungus, bacteria, viruses and microbial growth on 100% of the air flowing through the unit. The actual percentage of destruction depends on the velocity of the air, and the pollutant(s) treated. the door with one hand and gently taping on the bottom edge of the door with the other hand to release the door from its hinges. OPERATIONS Maximum Filtration An access door is provided at the front of the unit to permit access to the filters and speed selection switch. Opening the latch on the right side of the unit will permit the door to swing open. A safety door interlock switch cuts the power to the motor. If necessary, the door can be removed from the cabinet hinges by holding the top part of SMART SYSTEM LED STATUS DISPLAY Normal Filtration RECOMMENDED OPERATION The return plenum mount model operates in conjunction with your forced air HVAC system. A forced air distribution system continuously circulates the air inside your home. The HEPA/UV air purifier operates on the principal of bypass filtration, which means that a portion of the air being returned to the furnace is filtered on each pass. Over time all the air in the home will pass through the unit. It is recommended that the furnace blower be in operation whenever the system is in operation. For stand-alone attic installation, the HEPA/UV air purifier must be operated continuously whenever a part of the system is located in an unconditioned space to avoid condensation in the ductwork when the temperature is below freezing (32 F,0 C). Maintenance of the unit should be performed at regular intervals to keep the benefits of the HEPA/UV air purifier. LED DISPLAY The UV Lamp will function when the blower is in operation. There are two LED indicators on the front panel. The Amber LED indicates that the UV Lamp is on; the Red LED indicates that the Ballast is functioning. If the Ballast (Red) LED is on, and the Lamp (Amber) LED is off, the UV lamp is not functioning. If both LED lights are off, the ballast is not functioning. SANUVOX - MODEL SANUVAIR S300-11

4. GENERAL MAINTENANCE INFORMATION WHEN SHOULD I SERVICE MY UNIT? SERVICE AND ACCESSORIES Detailed maintenance information is located on the front decal on motor plate. PRE-FILTER Replace filter every 3 to 6 months or as needed. HEPA FILTER Replace filter every 2 to 5 years or as needed. Check regularly to maintain maximum performance from your HVAC system. For replacement filters, contact your local HVAC contractor. UV LAMP Replace lamp every 3 years. Lamps are available through your local HVAC contractor. INSIDE THE UNIT Once a year or as needed, clean the interior of the unit (Wall and Motor Plate) with a mild and non-abrasive soap. It is recommended to use products that are environmentally friendly. IMPORTANT: ALWAYS UNPLUG UNIT BEFORE SERVICING REPLACEMENT PARTS Part # LMPHGXJ105 T6 Dual Zone High Intensity 10.5" (266.7 mm) UV "J" Lamp for Sanuvair S300 Part # MSCFTR10 Pre-filter for Sanuvair S300 Part # MSCFTR11 HEPA Filter for Sanuvair S300 4.1 CHANGING FILTERS After opening the unit s door, grasp both edges of filter and pull with equal force to slide out the filter. 4.3 TROUBLESHOOTING PROBLEM Unit does not operate. Unit operates only on one speed. Unit vibrates. balancing weight 4.4 ELECTRICAL WIRING DIAGRAM Black 2.5uf M Brown Blue 4.2 CLEANING Once a year or as needed, clean the interior of the unit (Wall and motor plates) using mild non-abrasive soap and water. It is recommended to use products that are environmentally friendly. SUGGESTIONS Is power cord fully inserted in the unit s connector? Is outlet powered? Is door interlock switch operating? Possible loose wire inside electrical box, contact your local contractor. Check for excessive dust buildup or missing on the impeller wheel. Part # BST120/277GL 120/230 bolt Ballast with LED's for Sanuvair S300 Speed Selection 7.5uf UV Power Part # MSCMTR11 Motor for Sanuvair S300 120 volt Door Interlock Supply cord for optional UV module Part # MSCMTR7 Motor for Sanuvair S300 230 volt *Must be ordered with part# MSCCAP3 Capacitor. L G N 12 - SANUVOX - MODEL SANUVAIR S300

SANUVAIR S300 HEPA/UV LIMITED PARTS AND LAMP WARRANTY 3-YEAR WARRANTY Except for the UV Lamp and Ballast, this SANUVOX TECHNOLOGIES INC. product is warranted to be free from defects in material and workmanship under normal use and maintenance for a period of three years from the date of original installation. A new or remanufactured part to replace the defective part will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty. COMMERCIAL LAMP WARRANTY The SANUVOX TECHNOLOGIES INC. Ultra-Violet Lamps are warranted to be free from defects and operate for 2 years after installation, under normal use and maintenance in a commercial application. A new lamp to replace the defective lamp will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty. 3-YEAR RESIDENTIAL LAMP WARRANTY The SANUVOX TECHNOLOGIES INC. Ultra-Violet Lamps are warranted to be free from defects and operate for Three (3) years after installation, under normal use and maintenance in a residential application. A new lamp to replace the defective lamp will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty. 3-YEAR BALLAST WARRANTY The SANUVOX TECHNOLOGIES INC. Electronic Ballast is warranted to be free from defects and operate for three (3) years after installation, under normal use and maintenance in a residential or commercial application. A new ballast to replace the defective ballast will be provided without charge for the part itself, through a qualified servicing SANUVOX TECHNOLOGIES INC. dealer or distributor, PROVIDED the defective part is returned to our distributor. The replacement part assumes the unused portion of the warranty. THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL LABOR ALLOWANCE OR OTHER COSTS incurred for diagnosis, repairing, removing, installing, shipping, servicing, or handling of either defective parts of replacement parts. SUCH COSTS MAY BE COVERED BY a separate warranty provided by the installer. LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. SANUVOX WILL NOT BE RESPONSIBLE FOR: 1. Normal maintenance as outlined in the installation and servicing instruction or owner's manual. 2. Damage or repairs required as a consequence or faulty installation or application by others. 3. Failure to start due to voltage condition, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption or electrical service. 4. Damage or repairs needed as a consequence of any misapplication, abuse, improper servicing, unauthorized alteration, or improper operations. 5. Damage as a result of floods, winds, fires, lightning, accidents, corrosive atmosphere, or other conditions beyond the control of SANUVOX TECHNOLOGIES INC. 6. Parts not supplied or designated by SANUVOX TECHNOLOGIES INC. 7. SANUVOX TECHNOLOGIES INC. products installed outside the continental USA, Alaska, Hawaii, and Canada. 8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. Model number: Date of installation: Name of owner: Unit serial number: Installed by: Address of installation: SANUVOX TECHNOLOGIES INC. 146, rue Barr, St-Laurent, QC H4T 1Y4 Canada T. 1-888-SANUVOX F. 1-514-382-6475 www.sanuvox.com info@sanuvox.com SANUVOX - MODEL SANUVAIR S300-13

NOTES 14 - SANUVOX - MODEL SANUVAIR S300

NOTES SANUVOX - MODEL SANUVAIR S300-15

SANUVOX TECHNOLOGIES INC. 146, rue Barr, St-Laurent, QC H4T 1Y4 Canada T. 1-888-SANUVOX F. 1-514-382-6475 www.sanuvox.com info@sanuvox.com