ILED Aquarius Illuminated Windsock. User Manual

Similar documents
ILED Dorado. User Manual

IQL Helios Area-/Streetlight. User Manual

Operating Instructions

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Instructions

Zone 1 Linear Range - Installation Guide

OPERATING INSTRUCTIONS

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Terminal Boxes in Stainless Steel SLS**.T

Floodlight Range Installation Guide

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

ILED Aquarius CIRCLE-H Helideck Lighting System

Ex m Solenoid Operator Type 0519

BMRX Series ROTARY LEVEL CONTROL

Explosion protected terminal boxes type, GHG 72.

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Compact Sheet-Steel Light Fittings Series 6114/1

Clarius EP PLUS LED FLOODLIGHT Installation Guide

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Product manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Operating Instructions

DC Master 24/ A

Operating Instructions

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

EXEL-L. Detail of the internal side. Transparent polycarbonate

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

ABG Cable Glands Installation Procedure

Floodlight LED Series 6125

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

SynergEX Panelboards. Installation & Maintenance Information IF Panelboards for Hazardous Locations SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Direct-acting 3/2 way plunger valve

Linear Luminaire for Fluorescent Lamps

Leading the way in hazardous areas Features EATON

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Floodlight LED Series 6525

Floodlight LED Series 6525

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear fittings EVDL LED fitting - zones 21, & 22

Solenoid coils VACF Type codes

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Motors and drives for applications in explosive atmospheres

HTSB system System overview

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

Terminal Boxes Series 8125

Linear fluorescent luminaire LED V-CG-S

Operating Instructions

General spare parts. Accessories & Spare parts. Ordering information. SPB03: Battery with retrofit battery clamp (XX) Lithium 3xAA-Cell batteries

CCAI, CCAIF, CCAIF..H

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Operating Instructions (Translation)

Type 2REX-A. Oil & Gas / Heavy Industry

Multi-Mover Charger for model L25

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Control and Terminal Box Type A21-**-*****

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Instruction Manual. Ex-Time 40 / 50

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Compact temperature switch Model TCS

3. Operating instructions: Minor 200

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

EX Series User Manual

Compact differential pressure switch Models DC, DCC

OPERATION AND MAINTENANCE INSTRUCTIONS

Flameproof Level Sensor (Flameproof F/S FP)

Mini temperature switch Stainless steel switch enclosure Model TXS

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

INTERNATIONAL METAL ENGINEERING

Pendant Light Fitting IEC

Operating Instructions

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

ExBin-P Pressure switches 5 Pa Pa

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

EX-REPAIR AND MAINTENANCE RECEPTACLES

Technical Documentation

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Transcription:

Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 3.1 The light fitting has a type plate:... 4 3.2 The junction box has a type plate:... 5 4. Product Description... 6 5. Specifications... 7 5.1 General... 7 5.2 Dimensions... 7 6. Installation... 8 6.1 Preparation... 8 6.2 Assembly... 8 6.3 Connections... 9 7. Use... 10 7.1 Commissioning...10 7.2 Switches and Controls...10 7.3 Insulation test...10 8. Maintenance... 10 9. Recycling... 10 10. Contact details... 10 11. EC Declaration of Conformity... 11 Copyright IMT B.V. All rights reserved. No part of this may be copied, redistributed, published or changed without the prior written permission of IMT B.V. 2 Version 1.4 201302

1. Safety To ensure that the product is used safely and to optimize its life time, the following instructions must be observed. Make sure dust layers accumulating on the surface of the enclosure never exceed 5 mm. Only qualified personnel may install the product. Observe the locally applicable safety standards and safety regulations. During assembly, make sure the light fitting is not subjected to mechanical stress. Use all the mounting holes when installing the light fitting. Ensure that the cable gland used is certified Ex e IIC Gb and Ex t IIIC Db, and is suitable for the ambient temperature range and maintain a minimum degree of protection of IP66. Cables entering the enclosure shall be suitable for use in temperatures of up to at least 81 C. Ensure that the cable gland used is suitable for the dimensions and type of cable to be connected, to guarantee the IP degree. Ensure that the cable gland used has an IP level of IP66, IP67 or IP68 in conformance with EN 60529, and in case of an explosion proof lighting fixture, is Ex-e certified according to IEC 60079-7. When using metal glands, use an earthing plate and lock nut on the inside of the junction box. Ensure there is a reliable connection to the earthing system, both with the external earthing point and with the connection in the light fitting junction box. Never open the light fitting's housing. Do not clean the light fitting with a high-pressure stem or water jet. This will avoid damage that is not covered by the warranty. Only clean with a damp cloth. 2. Warranty 2.1 General The warranty for the light fittings in the ILED Illuminated Windsock series is only valid when the light fitting is used within the operating limits. The operating limits are: The minimum and maximum ambient temperature is -40 C to +55 C. The light fitting must be installed by qualified personnel according to the installation instructions. Damage caused by incorrect installation, accidents or external influences, such as a lightning strike or harmonic distortion not within EN 50055, are not covered by the warranty. The light fitting's lighting level depends on the temperature and is, therefore, not covered by the warranty. If an light fitting fails within the warranty period, IMT B.V. will provide a new light fitting with similar specifications free of charge. Before it can be confirmed that the damage is covered by the warranty, the defective light fitting must be sent to IMT B.V. at the user s expense for inspection. The user will be informed of the result(s) of the inspection. For individual warranty agreements see invoice. The windsock itself (the fabric) is not covered by warranty. 2.2 Life span Switching the light fitting with a semiconductor photoelectric cell or semiconductor relay has no consequences for the life span of the light fitting. Allowing a light fitting to flash that is adjusted standard as a steady burning light fitting, by means of a semiconductor photoelectric cell or semiconductor relay has, however, a negative effect on the life time. 3 Version 1.4 201302

3. Type plate 3.1 The light fitting has a type plate: 1. Type : ILED Aquarius 2. Version : Windsock : Obstruction light : Type X 3. Ambient temp.. : -40 C tot +55 C 4. Serial number 5. Year of production 6. Forward LED voltage : Max 48Vdc 7. LED Current : Windsock 56mm I_max=450mA : Obstruction 81mm I_max = 450 or 700mA 8. Power : Windsock max 22W : Obstruction max 34W 9. Marking : EX e IIC T4 Gb : Ex tb IIIC T135 C Db Attention. The current and power consumption depends on the purpose of the light fitting. For this reason the indicated values in the table can be different, but never more than the maximum value. Attention. Above mentioned information concerns the light fitting. For connections of the driver see label on driver. 4 Version 1.4 201302

3.2 The junction box has a type plate: 1. Type : ILED ULD35W DC IN GRP JB : ILED ULD35W AC IN GRP JB : ILED ULD35W DC IN SS JB : ILED ULD35W AC IN SS JB 2. Serial number : 3. Year of production : 4. Voltage : DC: 24Vdc±10% : AC: 90-250Vac 5. Current : DC: Max 2.34A : AC: Max 0.49A 6. Power : Max 40W 7. Pros. Short-Cut Current : 200A 8. Ambient temp.. : -40 C tot +55 C 9. Marking : EX e mb IIC T4 Gb : Ex tb IIIC T135 C Db IP66 Attention. The current and power consumption depends on the purpose of the light fitting. For this reason the indicated values in the table can be different, but never more than the maximum value. 5 Version 1.4 201302

4. Product Description All light fittings are designed for use in demanding surroundings. Features of the light fittings: High quality materials Sealed for life Vibration-proof. Based on ILED technology. 6 Version 1.4 201302

5. Specifications 5.1 General Construction : Stainless steel 316L (AISI) Construction light fitting : Marine grade aluminum anodized Lens : Borosilicate glass Illumination color Windsock : White Illumination color obstruction light : Red according to ICAO Annex 14 Vol. 1 Appendix 1 Illumination color U-code : Red according to ICAO Annex 14 Vol. 1 Appendix 1 Mechanical protection : IP66 Voltage, external driver : 95-250Vac 50/60Hz or 24Vdc ±10% Burning position : Horizontal (Re)ignition : Instant Power factor : >0,9 Connection : Fitted as standard with junction box, suitable for a single-phase connection Options The following options are available for all ILED Illuminated Windsock light fittings: Base Pole Top Pole with Top Light /Obstruction Light LAN network connection Spare sock 5.2 Dimensions 7 Version 1.4 201302

6. Installation 6.1 Preparation 1. Check whether the light fitting is to be installed in an environment that meets the ambient temperatures, gas group and temperature class. This data is included on the light fitting type plate. Installation of a light fitting in an environment that does not meet the specified ambient temperatures may have a negative effect on the life time of the light fitting. 2. Choose the correct type of protection for the light fitting. When doing so, ensure: a. The choice of cut-off current for the safety device is suitable for the expected nominal current. This depends on the number of light fittings that are connected. b. The safety device's cut-off power is suitable for the maximum short-circuit current that the mains power supply can provide. 6.2 Assembly 1. Remove the light fitting from the packaging. 2. Inspect the light fitting for mechanical damage. Installation of a light fitting in an environment that does not meet the specified ambient temperatures may have a negative effect on the life time of the light fitting. 3. Mount the light fitting to the construction. Ensure a reliable connection to the earthing system, both with the external earthing point and with the connection in the light fitting junction box. Take precautions to prevent corroding of the earth connection, to ensure its functionality. 4. Ensure that the cable glands used are suitable for the dimensions and type of cable to be connected, to guarantee the IP class, and in case of an explosion proof lighting fixture the glands are Ex certified as follows: Ex e IIC T4 Gb and Ex tb IIIC T135C Db IP66 ( Atex II 2 GD) by IEC 60079-0:2007 Ed5, IEC 60079-7 Ed 4, IEC 60079-31:2008 Ed 1. 5. The chosen gland for the fixture has a thread of M12 x 1.5mm. This gland is already provided with the cable of type Jobarco PUR flex TPE guaranteed up to at least 81 C by your manufacturer. Clean fixture only with damp cloth. 6. Assemble the various components according to the drawing in 5.2 and always use all available assembly holes. 7. Pull the sock over the sock holder so that the rim of the sock is over the round protuberance. (locking ring) 8. Assemble the quick strainer by sliding it over the sock from the front and lock it with the locking bolt. 8 Version 1.4 201302

9. The mounting plate with junction box can be mounted either with the junction box upwards, or downwards. During assembly, make sure the light fitting is not subjected to mechanical stress. 10. Cable glands and plugs shall be installed according to the instructions of the manufacturer, and shall not invalidate the specific characteristics of the type of protection of the electrical equipment on which they are mounted. The cable entries for the junction box are plane holes suitable for glands size M20 x 1.5 or M25 x 1.5. The cable glands for the junction box should be chosen in accordance to the selected cable, to ensure a guarantee of insulation of the gland and preventing the cable of transmitting pulling or twisting forces to the terminals in the junction box. Plugs, intended to close unused openings in the junction box, shall satisfy the required protection and IP class, and shall only be mounted or removed with the aid of a tool. Cable glands and blanking plugs may only be tightened or released during installation with proper tools and forces as indicated by the manufacturer. Cables shall be stripped according to the instructions of the manufacturer with the appropriate tools to guarantee the functional properties of the cable and IP degree. A wire sleeve shall be positioned to the bare wire ends suitable for the quadratic wire diameter and placed with a specified tool according to the instructions of the manufacturer. 11. Connect the cable to the terminals. The standard connecting terminals are suitable for a core diameter of 0.5-4 mm². Terminals shall be installed and tightened with appropriate tools according to the installation instructions of the manufacturer. The placement and assembly will be done in such a way that the degree of protection and safety of the device is guaranteed. 12. Check the completed connections. 13. Close the junction box. 6.3 Connections The terminal block design depends on the product type purchased. In the junction box is a standard terminal block as illustrated below: The following connections can be made L, N and PE : Connection for the power (For 24Vdc version L = + and N = -) 1 and 2 : Connection : DC output 1 ( LED current source) 3 and 4 : Connection : DC output 2 ( LED current source) 5 and 6 : Option : Connection for local network ( LAN) Warning Swapping over + and can damage the luminary Swapping over 1 and 2 can damage the luminary Swapping over 3 and 4 can damage the luminary Swapping over 5 and 6 can damage the luminary If metal cable glands or blind plugs are used, an earthing plate must be used in the junction box. 9 Version 1.4 201302

7. Use 7.1 Commissioning The light fitting can be used as soon as the installation has been completed. Obtaining a flash function by switching the supply voltage has a strongly negative effect on the life span. 7.2 Switches and Controls The light fitting can be equipped with a communication connection (option : see connections ). It is possible to set several factory settings using special software. For switching on, off and controlling the light fitting there is a control unit available (IMT-LED-MASTER). This control unit is connected with the communication connections in the light fitting. 7.3 Insulation test Installations in which ILED Illuminated Windsock light fittings are mounted may be tested with an insulation test. For this test, apply a maximum of 500 Vdc between earth and phase or neutral, or between the earth and the plus and minus of the 24Vdc version together, or between the earth and both of the network connections together. Never apply 500Vdc between phase and neutral, or between the plus and minus of the led fixture or between the network connections themselves. All light fittings have undergone a dielectric test during production (24Vdc version: 700Vdc during 60 seconds, Multi voltage version: 2100 Vdc during 60 seconds). In addition, the light fittings have also been subjected to an endurance test. 8. Maintenance The light fittings are `sealed for life and therefore cannot be opened. Because of this maintenance, as defined in the IEC 60079-17 standard, is not applicable and visual inspection only for correct functioning is sufficient. Opening the light fitting voids all claims under guarantee. Only clean with a damp cloth. 9. Recycling Agreements have been made with local authorities for the recycling of the light fittings within the framework of the WEEE (Waste Electrical and Electronic Equipment Directive) We refer to your local partner (see 'Contact details'). The local partner will take care of further disposal 10. Contact details IMT B.V. Pascalweg 10a, 4104 BG Culemborg P.O. Box 88, 4100 AB Culemborg THE NETHERLANDS Phone : +31 (0)88 12 69 100 Fax : +31 (0)88 12 69 101 E-mail : sales@imt.eu For an up-to-date overview of all national and international contacts, visit our website: www.imt.eu. 10 Version 1.4 201302

11. EC Declaration of Conformity The undersigned, representing the company IMT B.V. Pascalweg 10a 4104 BG Culemborg The Netherlands Phone :+31 (0) 88-12 69 100 declares that the product: ILED Aquarius Illuminated Windsock and Obstruction luminaires, type IMT-LED Windsock, Obstruction, U-Code marked with Ex II 2 GD Ex e IIC T4 Gb or Ex II 2 GD Ex tb IIIC T135 C Db complies with the provisions of the EC directive(s) - including all supplements. 94/9/EC 2004/108/EC Equipment and protective systems intended for use in potentially explosive atmospheres Electromagnetic Compatibility and that provisions have been made in all standards and/or technically related specifications below. Standard Issue Title EN 60079-0 2009 EN 60079-7 2007 EN 60079-31 2009 Electrical apparatus for potentially explosive atmospheres General requirements Electrical apparatus for potentially explosive atmospheres Increased safety e Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure t EN 61547 2009 Equipment for general lighting purposes. EMC immunity requirements EN 61000-3-2 2006 Limits for harmonic current emissions (equipment input current up to and including 16A per phase), EC type certificate number : IECEx SIR 11.0046X Sira 11ATEX3101X Culemborg, 20 juni 2011 IMT B.V. R.L.L.M.G. Mignot, Managing director 11 Version 1.4 201302

IMT B.V. Pascalweg 10a, 4104 BG Culemborg P.O. Box 88, 4100 AB Culemborg Tel: +31 (0)88 12 69 100, Fax +31 (0) 88 12 69 101 www.imt.eu, sales@imt.eu