Flame arresters 4301A/4319A ATEX Approved

Similar documents
Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration)

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 320. Product Description. (Vertical, in-line, detonation )

94406 Vertical Inline Deflagration Flame Arrester. Features

94407 Horizontal Inline Deflagration Flame Arrester

INSTALLATION AND MAINTENANCE

Flame arresters/vents

Protection & Safety Equipments For Storage Tanks. Pressure / Vacuum Relief Valves, Flame Arresters, Free Vent, Gauge Hatch.

ANDERSON GREENWOOD TYPE 4410 SIDE ENTRY ATMOSPHERIC VACUUM RELIEF VALVES

DETONATION FLAME ARRESTER MODEL 7658A

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS

In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

Operating Instruction Inline Detonation Flame Arrester

Amal are not only known for the high quality of their products but also for the exemplary levels of commitment and dedication shown to their

Operating Instructions Inline Detonation Flame Arrester and

SERIES 670E End-of-Line Deflagration Flame Arrester

PROTEGO Detonation Flame Arresters. Volume 4. for safety and environment

Model 6A00 TECHNICAL BULLETIN 6A00 - TB Inline Deflagration Flame Arrestor

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) Model 6A00. Inline Deflagration Flame Arrestor SECTION I

Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

In-Line Detonation Flame Arrester PROTEGO DA-CG

KITO explosion and endurance burning flame arrester devices

PROTEGO Detonation Flame Arresters. Volume 4. Volume 4. for safety and environment

Flame Arrestor Design and Application Data

SERIES R - MD MOR & GOR

Explosion and flame-proof single phase electric motors

Explosion and flame-proof cast iron electric motors

Biogas safety control equipment

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester

Installation, Operation and Maintenance Manual for Model 7758A Deflagration and Detonation Flame Arrester

Model 7A00 7A00 - TB TECHNICAL BULLETIN. Detonation Flame Arrestor

Instructions for installation, service and maintenance 1. INTRODUCTION APPLICATION TECHNICAL DATA, IDENTIFICATION...

VAREC 5810B AND 5820B SERIES RELIEF VALVE WITH FLAME ARRESTER

Powder and Bulk Technology

Sample gas pumps P2.x ATEX

In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

INSTRUCTION MANUAL FOR

In-line sampling system for representative sampling without process interruption

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

Liquid ring vacuum pumps with magnetic coupling

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Tightness control TC. Product brochure GB Edition 12.10

Kunkle Bailey 756 safety relief valve

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Sample gas pumps P 2.3, P 2.3C, P 2.83, P 2.4, P 2.4C, P 2.84

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

TRIVAC. Rotary Vane Vacuum Pumps, Oil-Sealed; 1.5 to 65 m 3 /h (0.7 to 38.3 cfm) S 1,5, Single-Stage. TRIVAC E, Two-Stage. TRIVAC NT, Two-Stage

Installation, Operation & Maintenance. Model 7688 In Line Deflagration Flame Arrester. ATEX Certified

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

SITRANS P measuring instruments for pressure

SILOXA FAKA Gas Cleaning System

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Why use a flame arrester?

Explosion proof electric motor For Fuel dispensing application. Main characteristic

P R O D U C T I N F O R M A T I O N. Gear pumps. Series LZ / LZM

SUITABLE FOR EXAMPLES OF USE APPROVALS. TS EC type examination. Requirements AD 2000 Data sheet A2 DIN EN ISO PED 2014/68/EU

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Liquid ring vacuum pumps in compact design

HAZARDOUS AREA. Multi ac THE VERY BEST IN HAZARDOUS AREA VACUUM RECOVERY SYSTEMS INNOVATION THROUGH EXPERIENCE.

FRP VENTS. Fiberglass Reinforced Plastic Vents... No Exposed Metal Components. Distributed by Relevant Solutions relevantsolutions.

FILTER, REGULATOR AND FILTER REGULATOR stainless steel 316L compact 1/4, high flow 1/4, 1/2, 3/4 and 1

Control and Terminal Box Type A21-**-*****

Liquid ring vacuum pumps

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Zirconia Oxygen Probe

Factor 1) Modulating torque 4) [Nm]

VERSAFLOW MAG 4000 Quick Start

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

p Additional dimensions see section dimensions.

BFG range BFGC range BFN range

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

megaflo BSP Pressure Relief Vent

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

Flap-Type Flow Meter Prall

Filter Housing SG ATEX Standard

Liquid ring compressors

Installation, Operation & Maintenance. Model 7678 End of Line Deflagration Flame Arrester ATEX Certified

Connection parts with nominal width DN 6 Valves, coupling valves, protection caps, fittings, adapters and connections for analytic instruments

Valve attachment Gearbox Reduction ratio :1 5) : ,

SUITABLE FOR EXAMPLES OF USE APPROVALS. Type approval Deutsche Bahn. Requirements. AD 2000 Data sheet A2 DIN EN ISO PED 2014/68/EU

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he

Volumeter. RMG Meßtechnik GmbH. Publication No E

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

Process screen basket filter PRFS

VALFONTA USE, INSTALLATION AND MAINTENANCE MANUAL PNEUMATIC CONTROL VALVE MODEL C1

OPTIMASS 2000 Technical Datasheet

Nominal sizes: DN 10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150 Pressure rating: PN 16. Product No. Nominal size Body connection

SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL

Double Block and Bleed Plug Valves

FLOW SOLUTION PROVIDER

SUITABLE FOR EXAMPLES OF USE APPROVALS. Type approval Deutsche Bahn. Requirements AD 2000 Data sheet A2 DIN EN ISO PED 2014/68/EU

Flash Point Process Analyzer

dp pumps dpv vertical pumps The dynamics of water made in holland

Transcription:

Flame arresters 4301A/4319A ATEX Approved The Whessoe Vapour Control range of flame arresters are designed and certified for use in conjunction with Whessoe pressure and vacuum valves, as well as for use as an inline flame arrester (4301A) or as an end of line flame arrester (4319A) Features Low pressure drop Crimped ribbon design Removable element for easy maintenance Sizes 2 (50mm) to 12 (300mm) Body materials aluminium, carbon steel, stainless steel Stainless steel element Full flange ANSI and DIN flanges Condensate drain plugs ATEX approved General application Storage tank farms Petroleum & chemical Methane gas production In waste digesters Pipelines with flammable gasses Whessoe Vapour Control are constantly developing their range of products, therefore additional sizes, additional materials and settings outside the normal range can be offered. Please contact the sales office with your requirements. Technical data Gas group : IIA, IIB1, IIB2, IIB3, IIB, IIC Sizes inch : 2-12 Sizes mm : 50-300 Certification : EN 12874 Tyco reserves the right to change the contents without notice WEVSB-0034-EN-0607

Flame arresters 4301A ATEX Approved dimensions and weights Element Length * * 19mm, if mounted directly under an atmospheric vented P/V valve. 38mm, if mounted within a pipeline not directly to atmosphere or a piped away P/V valve (The DN50 arrester remains 19mm) Dimensions 4301A Nominal size inch 2 3 4 6 8 10 12 A 50 76 101 152 203 254 305 B (19mm element) 247 299 346 452 524 571 678 B (38mm element) 266 318 365 471 543 590 697 C 202 261 346 486 548 620 755 All dimensions in millimetres Weights 4301A Nominal size inch 2 3 4 6 8 10 12 Aluminium Carbon Steel Stainless Steel All weights in kilograms 13 21 30 40 80 100 150 19 29 45 70 122 204 286 19 29 45 70 122 204 286 Tyco reserves the right to change the contents without notice page 2

Flame arresters 4301A ATEX Approved pressure drops Flame arresters 4301A ATEX Approved - For use Inline or directly under a piped away P/V valve 4301A Flame arrester pressure drop / flow - IIA gasses Nominal Pipe size mm 50 80 100 150 200 250 300 Element length mm 19 38 38 38 38 38 38 50 0,7 <0,5 <0,5 <0,5 <0,5 <0,5 <0,5 100 1,8 1,0 0,5 <0,5 <0,5 <0,5 <0,5 200 4,8 2,4 1,2 0,5 <0,5 <0,5 <0,5 400 12,7 6,2 3,0 1,2 0,6 <0,5 <0,5 600 20,6 11,1 5,3 1,9 0,9 0,6 <0,5 800 25,4 16,7 7,9 2,8 1,3 0,8 0,5 1000 22,5 10,9 3,9 1,7 1,0 0,7 2000 27,9 10,3 4,3 2,5 1,6 4000 26,5 11,6 6,4 4,1 6000 39,9 20,4 11,5 7,2 8000 29,3 17,3 10,9 10000 36,6 23,3 14,9 38,8 27,7 4301A Flame arrester pressure drop / flow - IIB1, IIB2 & IIB3 gasses 50 1,7 1,2 0,7 <0,5 <0,5 <0,5 <0,5 100 3,2 2,4 1,4 0,7 <0,5 <0,5 <0,5 200 6,6 4,6 2,8 1,4 0,8 0,5 <0,5 400 19,5 9,1 5,4 2,7 1,5 1,0 0,7 600 49,3 15,0 8,0 1,9 2,2 1,5 1,1 800 23,5 11,1 2,8 2,9 2,0 1,4 1000 36,1 14,7 3,9 3,6 2,4 1,8 2000 52,6 10,3 6,9 4,7 3,4 4000 26,5 15,6 9,3 6,6 6000 39,9 30,8 15,5 10,2 8000 57,7 24,5 14,6 10000 101,0 37,9 20,5 118,5 51,9 4301A Flame arrester pressure drop / flow - IIB gasses 50 4,8 1,9 1,1 0,5 <0,5 <0,5 <0,5 100 10,6 4,0 2,3 1,1 0,6 <0,5 <0,5 200 27,0 8,7 4,8 2,2 1,2 0,8 0,6 400 91,9 21,1 10,6 4,6 2,4 1,6 1,1 600 224,5 39,4 17,2 7,2 3,7 2,4 1,7 800 66,0 27,0 10,1 5,0 3,2 2,3 1000 103,0 38,6 13,2 6,4 4,1 2,9 2000 148,3 35,9 14,8 8,9 6,1 4000 134,6 41,2 21,7 13,9 6000 347,2 87,6 40,9 24,3 8000 162,0 68,8 38,2 10000 Pressure drop mbar (either pressure or vacuum flow) 272,6 107,8 56,4 4301A Flame arrester pressure drop / flow - IIC gasses 20 9,3 12,0 7,1 3,4 30 14,0 18,2 10,7 5,1 50 23,5 30,7 18,0 8,5 100 47,8 63,9 36,8 17,2 200 137,9 77,0 35,1 400 320,2 168,6 73,4 600 276,4 115,0 800 160,0 1000 208,8 2000 4000 Pressure drop mbar (either pressure or vacuum flow) Tyco reserves the right to change the contents without notice page 3

Flame arresters 4301A ATEX Approved pressure drops Flame arresters 4301A ATEX Approved - For use directly under a P/V valve with atmospheric discharge 4301A Flame arrester pressure drop / flow - IIA & IIB1 gasses Nominal Pipe size mm 50 80 100 150 200 250 300 Element length mm 19 19 19 19 19 19 19 50 0,7 <0,5 <0,5 <0,5 <0,5 <0,5 <0,5 100 1,8 0,6 <0,5 <0,5 <0,5 <0,5 <0,5 200 4,8 1,4 0,7 <0,5 <0,5 <0,5 <0,5 400 12,7 3,7 1,8 0,7 <0,5 <0,5 <0,5 600 20,6 6,7 3,2 1,2 0,5 <0,5 <0,5 800 25,4 10,0 4,8 1,7 0,8 <0,5 <0,5 1000 13,5 6,6 2,3 1,0 0,6 <0,5 2000 16,8 6,2 2,6 1,5 1,0 4000 15,9 7,0 3,9 2,4 6000 23,9 12,2 6,9 4,3 8000 17,6 10,4 6,5 10000 22,2 14,0 8,9 23,3 16,6 4301A Flame arrester pressure drop / flow - IIB2 & IIB3 gasses 50 1,7 0,7 <0,5 <0,5 <0,5 <0,5 <0,5 100 3,2 1,4 0,9 <0,5 <0,5 <0,5 <0,5 200 6,6 2,7 1,7 0,8 <0,5 <0,5 <0,5 400 19,5 5,5 3,2 1,6 0,9 0,6 <0,5 600 49,3 9,0 4,8 2,4 1,3 0,9 0,7 800 14,1 6,6 3,1 1,7 1,2 0,9 1000 21,6 8,8 3,8 2,1 1,5 1,1 2000 31,6 8,3 4,2 2,8 2,1 4000 28,6 9,3 5,6 4,0 6000 79,4 18,5 9,3 6,1 8000 34,6 14,7 8,8 10000 60,6 22,7 12,3 71,1 31,1 4301A Flame arrester pressure drop / flow - IIB gasses 50 2,0 0,7 <0,5 <0,5 <0,5 <0,5 <0,5 100 5,0 1,6 0,9 0,7 <0,5 <0,5 <0,5 200 14,4 4,0 2,0 1,3 0,7 <0,5 <0,5 400 46,0 11,0 5,0 2,8 1,4 0,9 0,7 600 94,4 21,2 9,2 4,3 2,2 1,4 1,0 800 34,4 14,4 6,0 3,0 1,9 1,4 1000 50,6 20,7 8,0 3,9 2,5 1,7 2000 68,3 21,5 8,9 5,3 3,7 4000 80,8 24,7 13,0 8,3 6000 208,3 52,6 24,5 14,6 8000 97,2 41,3 22,9 10000 Pressure drop mbar (either pressure or vacuum flow) 163,6 64,7 33,8 4301A Flame arrester pressure drop / flow - IIC gasses 20 9,3 3,9 2,3 1,1 30 14,0 5,9 3,5 1,7 50 23,5 9,8 5,8 2,8 100 47,8 19,8 11,7 5,6 200 40,1 23,5 11,2 400 82,3 47,9 22,5 600 73,0 34,0 800 45,7 1000 57,6 2000 4000 Pressure drop mbar (either pressure or vacuum flow) Tyco reserves the right to change the contents without notice page 4

Flame arresters 4319A ATEX Approved Dimensions and weights Dimensions 4319A Element length mm 19 19 19 19 19 19 19 A 50 76 101 152 203 254 305 B 160 185 235 360 405 495 585 C 203 261 347 450 590 730 870 All dimensions in millimetres Weights 4319A Nominal size inch 2 3 4 6 8 10 12 Aluminium Carbon Steel Stainless Steel All weights in kilograms 10 15 23 31 60 80 125 13 19 30 46 80 132 185 13 19 30 46 80 132 185 Tyco reserves the right to change the contents without notice page 5

Flame arresters 4319A ATEX Approved Pressure drops Flame arresters 4319A ATEX Approved - End of line (endurance burn) 4319A Flame arrester pressure drop / flow - IIA gasses Nominal Pipe size mm 50 80 100 Element length mm 19 19 19 50 0,7 <0,5 <0,5 100 1,5 0,5 <0,5 200 3,4 1,1 0,7 400 8,9 2,5 1,5 600 16,6 4,2 2,6 800 26,4 6,3 3,9 1000 8,6 5,4 2000 16,4 4000 6000 8000 10000 16000 Pressure drop mbar (either pressure or vacuum flow) Notes 1. DN 150, 200, 250 & 300 are not available. 2. Gas groups IIB1, IIB2, IIB3, IIB & IIC are not available. Flame arresters 4319A ATEX Approved - End of line (standard / short burn) 4319A Flame arrester pressure drop / flow - IIA & IIB1 gasses Nominal Pipe size mm 50 80 100 150 200 250 300 Element length mm 19 19 19 19 19 19 19 50 0,7 <0,5 <0,5 <0,5 <0,5 <0,5 <0,5 100 1,5 0,5 <0,5 <0,5 <0,5 <0,5 <0,5 200 3,4 1,1 0,7 <0,5 <0,5 <0,5 <0,5 400 8,9 2,5 1,5 0,5 <0,5 <0,5 <0,5 600 16,6 4,2 2,6 0,8 <0,5 <0,5 <0,5 800 26,4 6,3 3,9 1,2 0,7 <0,5 <0,5 1000 8,6 5,4 1,5 0,8 <0,5 <0,5 2000 16,4 3,9 2,0 1,2 0,8 4000 11,1 5,2 3,0 1,9 6000 21,9 9,7 5,3 3,3 8000 15,6 8,3 5,0 10000 22,8 11,9 6,9 26,4 14,7 4319A Flame arrester pressure drop / flow - IIB2 & IIB3 gasses 50 1,3 0,5 <0,5 <0,5 <0,5 <0,5 <0,5 100 2,8 1,0 0,5 <0,5 <0,5 <0,5 <0,5 200 5,9 2,1 1,1 <0,5 <0,5 <0,5 <0,5 400 13,4 4,5 2,2 0,8 0,5 <0,5 <0,5 600 22,7 7,1 3,3 1,3 0,8 0,5 <0,5 800 9,9 4,5 1,7 1,0 0,7 <0,5 1000 13,0 5,8 2,1 1,3 0,9 0,6 2000 13,1 4,5 2,6 1,8 1,2 4000 9,8 5,6 3,7 2,6 6000 16,2 8,9 5,7 3,9 8000 12,6 8,3 5,4 10000 16,7 11,9 6,9 26,4 12,1 4319A Flame arrester pressure drop / flow - IIB gasses 50 3,0 0,9 <0,5 <0,5 <0,5 <0,5 <0,5 100 8,2 2,0 0,9 0,6 <0,5 <0,5 <0,5 200 24,9 5,3 2,1 1,1 0,7 <0,5 <0,5 400 82,9 15,2 5,3 2,3 1,4 0,9 0,7 600 173,0 29,7 9,7 3,6 2,1 1,4 1,0 800 48,8 15,3 5,0 2,9 1,9 1,4 1000 72,4 22,0 6,5 3,7 2,4 1,7 2000 72,8 16,8 8,5 5,3 3,6 4000 57,8 23,3 12,8 8,1 6000 142,2 49,0 24,1 14,1 8000 90,0 40,4 22,1 10000 Pressure drop mbar (either pressure or vacuum flow) 150,5 63,2 32,6 4319A Flame arrester pressure drop / flow - IIC gasses 20 11,3 4,0 1,9 0,7 <0,5 <0,5 <0,5 30 18,2 6,2 3,0 1,1 0,7 <0,5 <0,5 50 34,0 11,0 5,1 1,9 1,2 0,8 0,6 100 80,3 25,1 11,1 4,0 2,4 1,6 1,1 200 59,6 25,4 8,5 4,9 3,3 2,3 400 131,1 60,1 19,0 10,7 6,9 4,8 600 97,7 31,2 17,2 10,9 7,5 800 44,6 24,3 15,3 10,3 1000 59,0 32,0 20,0 13,4 2000 75,7 47,0 30,9 4000 Pressure drop mbar (either pressure or vacuum flow) 108,1 73,1 Tyco reserves the right to change the contents without notice page 6