3 " NOM. 316 G, ER V RO N HA. TYP SEE DETAILS A1.7 THROUGH A1.10 FOR FIXTURE OPENING RECOMMENDATIONS IE ARR XC 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.2 A "M 1'-0 300C PANEL SPLICE SEE DETAIL A1.3 300C SYSTEM PROFILE 13" NOM. 1116 TYPICAL SYSTEM SECTION SEE DETAIL THIS SHEET DETAIL AX "M 4'-0 GER N HA E WIR P., TY G CIN SPA 300C PANEL SEE DETAIL A1.1 WALL ANGLE SEE DETAIL A1.5 WALL ANGLE SEE DETAIL A1.5 4'-0 "M SPA CIN G, TY P. 3 0 3'-0 0C " M PAN IN - EL 19' LENG -8" TH MA X 0 11 C P -1 AN 3/ E 16 L W "N I OM DTH. IER FLOATING TRIM SEE DETAIL A1.6 TRIM NOT SHOWN FOR CLARITY 30 PANEL BUTT JOINT SEE DETAIL A1.4 AX CAR R PAN SUSPENSION REQUIREMENTS SEE DETAIL A1.2 "M -0 2' EL O VER AX HA N G, T YP. INTERIOR INSTALLATION All rights reserved. T his dr awing is the pr oper ty of H unt er Dougl as. I t may not be copi ed or mult i pl i ed, nei t her no t b e su bmi t t e d f o r per usal to thir d par ties. OVERALL ISOMETRIC VIEW PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.0
3 16 3 " NOM. SYSTEM HEIGHT 1 16 3 " PANEL HEIGHT 1 16 3 " PANEL HEIGHT PERFORATION #160 AT FACTORY PANEL END 3'-0" MINIMUM PANEL LENGTH 19'-8" MAXIMUM PANEL LENGTH** 11 25 32 " (11.81) PANEL WIDTH ONLY NON-PERFORATED FACTORY PANEL END FACTORY PANEL SIDE VIEW *VERTICAL SUPPORT OMITTED FOR CLARITY **PANEL LENGTHS VARIABLE IN 1/8" INCREMENTS, TOLERANCE ±1/8" FACTORY PANEL ENDS *SUSPENSION OMITTED FOR CLARITY 11 25 32 " (11.81) PANEL WIDTH 300C PANEL MATERIAL THICKNESS.028" ALUMINUM 300C PANEL FINISHES PAINTED & POWDER COATED PERFORATION DIRECTION DECORATED WOOD FINISH (POWDER COATED) WOOD VENEER PERFORATION #160 PERF AREA 23% OPEN HOLE DIAMETER 0.060" AVAILABLE PANEL PERFORATION of H unter Dougl as. It not be submi t ted f or PANEL SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.1 SCALE: NTS DATE: 8/15/16
4'-0" MAX HANGER WIRE SPACING, TYP. 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS NOTE: S ARE DIRECTIONAL, CHECK ORIENTATION PRIOR TO INSTALLATION SIDE VIEW OF WITH PANEL 1'-0" MAX CARRIER OVERHANG, TYP. SIDE VIEW OF END VIEW OF WITH PANEL 300C PANEL 4'-0" MAX CARRIER SPACING, TYP. END VIEW OF 2'-0" MAX PANEL OVERHANG, TYP. MATERIAL: FINISH: PART LENGTH:.040" ALUMINUM MATTE BLACK 16'-0" of Hunter Douglas. It not be submitted f or SUSPENSION SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.2 SCALE: NTS
12" MAXIMUM AT CARRIER SPLICE 12" MAXIMUM AT CARRIER SPLICE CARRIER SPLICE 12 GA HANGER WIRE, NOT BY HUNTER DOUGLAS 12"MAXIMUM AT CARRIER SPLICE 300C PANEL 3 16 3 " NOM. 12"MAXIMUM AT CARRIER SPLICE 12 GA HANGER WIRE, NOT BY HUNTER DOUGLAS SECTION - SNAP SPLICE TABS INTO 300C CARRIER IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A LUXALON CARRIER SPLICE, TO CONNECT TWO FACTORY CARRIER ENDS. THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. INTERIOR INSTALLATION of H unter Douglas. It CARRIER SPLICE PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.3 DATE: 8/15/16
4'-0" MAX CARRIER SPACING, TYP. 12 GA HANGER WIRE BY OTHERS, TYP. 24" MAXIMUM PANEL OVERHANG 24" MAXIMUM PANEL OVERHANG 300C PANEL DO NOT FASTEN PANEL ENDS TOGETHER. DOING SO WILL CAUSE DEFORMATION IN PANEL FACE. INTERIOR INSTALLATION ISOMETRIC VIEW OF FACTORY PANEL ENDS AT JOINT *CARRIERS NOT SHOWN FOR CLARITY NOTE: 300C PANEL ENDS MUST BUTT AT FACTORY PANEL ENDS AND PANELS CANNOT BE SPLICED. PANEL ENDS CAN ONLY BE FIELD CUT AT PERIMETERS WHERE TRIMS ARE USED FOR TERMINATIONS. PANEL SPLICES ARE NOT REQUIRED NOR AVAILABLE. of H unter Douglas. It PANEL BUTT JOINT PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.4
FIELD MITER TRIMS AT CORNERS SUSPENSION NOT SHOWN FOR CLARITY FIELD CUT 300C PANEL ENDS FOR LENGTH FIELD CUT 300C PANEL SIDES FOR WIDTH USE WALL ANGLE AS HOLD DOWN CLIP FIELD CUT 300C PANEL SIDE SECTION VIEW AT WALL ANGLE & 300C PANEL SIDE USE WALL ANGLE TO SECURE CUT PANEL SIDE. TYPICALLY NOT REQUIRED AT FIELD CUT PANEL ENDS. FACTORY PANEL ENDS DIRECT FASTEN WALL ANGLE TO STRUCTURE WALL ANGLE WALL ANGLE 12'-0" PART LENGTH FACTORY PANEL ENDS INTERIOR INSTALLATION *VERTICAL SUPPORT OMITTED FOR CLARITY of H unter Dougl as. It may not be copi ed or m u l t i p l i e d, ne i t h e r not be submi t ted f or WALL ANGLE TRIM PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.5 SCALE: NTS DATE: 8/15/16
2-1/4" 2 1 4 " 3-3/16" 12 GA HANGER WIRE, NOTCH TRIM AS NECESSARY, TYP. FIELD CUT 300C PANEL ENDS FIELD MITER TRIMS AT CORNERS FASTENERS TO SECURE 300C J-TRIM TO CARRIER BY OTHERS, TYP. FIELD CUT 300C PANEL SIDES FOR WIDTH FIELD CUT PANEL SIDE USE TRIM ANGLE AS HOLD DOWN 3 16 3 " DOUBLE-SIDED ADHESIVE TO SECURE TRIM ANGLE FIELD CUT PANEL END SECTION SCALE: 6" = 1'-0" SECTION SCALE: 6" = 1'-0" WALL ANGLE TO SECURE FIELD CUT PANEL SIDE. TYPICALLY NOT REQUIRED AT FIELD CUT PANEL ENDS & FULL PANEL EDGES. 2-1/4" 3-3/16" 300C J-TRIM FOR FLOATING CONDITION 10'-0" PART LENGTH FULL 300C PANELS INTERIOR INSTALLATION *VERTICAL SUPPORT OMITTED FOR CLARITY of H unter Dougl as. It m ul t i p l i e d, n e i t h er not be submi t ted f or FLOATING TRIM PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.6 SCALE: NTS DATE: 8/15/16
MAX LENGTH VARIES BASED ON PANEL LENGTH INTERRUPT CARRIER AT FIXTURE LOCATION, TYP. 2" MIN FROM PANEL END, TYP. ROUND OPENINGS FOR CAN LIGHTS, SPEAKERS, SPRINKLERS, ETC. 8" MAX WIDTH CENTERED IN PANEL RECOMMENDED MAX VARIES BASED ON PANEL LENGTH 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 300C PANEL FIELD CUT FOR FIXTURE OPENING 2" MIN FROM PANEL END, TYP. RECOMMENDED 8" MAX WIDTH FOR FIELD CUT OPENING CENTERED IN PANEL INTERRUPT CARRIER AT FIXTURE FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS BEYOND FIELD CUT 300C PANEL FIELD CUT 300C PANEL SECTION - SECTION - NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIM FOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS of Hu nter Douglas. It FIELD CUT PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.7
INTERRUPT CARRIER AT FIXTURE LOCATION, TYP. MAX LENGTH VARIES BASED ON PANEL LENGTH VARIES TO ACCOMMODATE FIXTURE WIDTH 11.81 MAX WIDTH TO REMAIN ON MODULE MAX VARIES BASED ON PANEL LENGTH FACTORY 300C PANELS 11.81 MAX WIDTH TO REMAIN ON MODULE INTERRUPT CARRIER AT FIXTURE FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS BEYOND FIELD CUT 300C PANEL FULL 300C PANEL FULL 300C PANEL SECTION - SECTION - NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of H unter Douglas. It INTERRUPTED PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.8
MAX WIDTH VARIES BASED ON PANEL LENGTH MAX LENGTH VARIES 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 2" MIN FROM PANEL SIDE, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES BASED ON PANEL LENGTH FIXTURE CUT IN 300C PANEL FACE MAX WIDTH VARIES 2" MIN FROM PANEL SIDE, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. CONTINUOUS 300C CARRIER BEYOND FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIELD CUT 300C PANEL FIELD CUT 300C PANEL SECTION - SECTION - NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIM FOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS of Hu nter Douglas. It FIELD CUT PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.9
4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES PANEL LENGTHS FACTORY FABRICATED TO MAINTAIN PANEL SEAM MODULE MAX LENGTH VARIES BASED (PANEL WIDTH) ON 11.81 INCREMENTS FACTORY FULL 300C PANELS 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES BASED ON 11.81 INCREMENTS (PANEL WIDTH) OPENING WIDTH VARIES 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. CONTINUOUS 300C CARRIER BEYOND FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FULL 300C PANEL FULL 300C PANEL SECTION - SECTION - NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of H unter Douglas. It INTERRUPTED PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.10
COMPRESSION STRUT SPLAYED 12 GA HANGER WIRE, BY OTHERS, TYP. 45 45 N E 45 45 W S 300C PANEL LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. (4) #12 GAUGE WIRES SPLAYED 90 FROM EACH OTHER AT ANGLE NOT EXCEEDING 45 FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. INTERIOR INSTALLATION of H unter Douglas. It SEISMIC SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.11 SCALE: NTS DATE: 8/15/16