DETAIL 'A' INTERIOR INSTALLATION. OVERALL ISOMETRIC VIEW (unless noted otherwise) 300C CARRIER 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS

Similar documents
INTERIOR INSTALLATION

12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.1 MAIN RUNNER SPLICE. SPECIFICATIONS (unless noted otherwise)

MIDDLE SECTION REPRESENTS "BLADE SIZE" (EXAMPLE: 24 = 24/32" [3/4"] 48 = 48/32" [1 1/2"]) REPRESENTS NUMBER OF BLADES PER 12" WIDE PANEL WG WB

PANEL SPLICE SEE DETAIL A1.3 FLOATING TRIM SEE DETAIL A1.7 TRIM NOT SHOWN FOR CLARITY

SafeLite Installation Steps For a 2 x 2 Light Fixture

2006 Saturn Ion ACCESSORIES & EQUIPMENT Doors - Ion

SECTION METAL LOCKERS. A. ADAAG - Americans with Disabilities Act, Accessibility Guidelines.

CLEANROOM PRODUCTS FLUSH HEPA GRID WITH INTEGRAL LIGHTING PLENUM MODULES CUSTOM AIR HANDLERS PLENUM MODULES FAN POWERED PLENUM MODULES

GRAVITY VENTILATORS SIZING

CUSTOM FLOW ARCHITECTURAL SLOT DIFFUSER

20" 1/1/14 Drawn By: Plan. R Custom 3 4 " " Title: S.S Brake-metal corner. View: Detail System Type: Scale:

AEROWINGS Sun Control Systems

No clips required for this panel system

SECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.

COMPACT BUSWAY 40 & 60 AMP HOUSING

Section 3. Custom. Recessed

SLIDING DOOR SYSTEM_ S42 TECHNICAL BOOK. System description Accessories

1501 Industrial Way N., Toms River, NJ Fax: PACKING LIST MUSTANG GT LONG TUBE HEADERS (M30000)

Short-throw Shifter Installation Guide

CEILING MOUNTED WORK STATION STEEL BRIDGE CRANE

HSpecialties Inc. TABLE OF CONTENTS

Notes: 2 3/8" 60mm. (1) One lamp with satin lens only (2) Not available for T8 Add 9 per lamp. Specify quantity Requires 120V or 277V

2-120-T Aurora BRO FEATURES

1. Product Overview: Read all instructions for installing Drop-In Panels before starting.

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K K. EM/10W 10-watt emergency battery [4] TrimLock.

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Running Magnet 2.0 Recessed High-tech LED lighting system for interior architecture

6DR 6 Downlight Round

REVISION DESCRIPTION:

LUXLINEAR LOW 1707 SLEEKER ILLUMINATION MECHANICAL. Indoor/Dry Location Series

P15 - P44: 5-3/4 P62: 6-1/2. SCA Sloped ceiling TrimLock K K K K TW Tunable white (80 CRI, 2700K 5000K) 65 Open

2-520-T Miro BRO FEATURES

ISO 9001:2008

2-115-T Aqua BRO FEATURES

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

Safety Grating DIAMOND-GRIP PRODUCT DESCRIPTION FEATURES & BENEFITS MATERIAL SPECIFICATIONS. Note:

NOTES: REQUIRES REMOTE DRIVER(S) (see page 4 for more info) LED DRIVE POWER DIRECT INDIRECT* VLO

NIOB-2 2" BWF IOLITE TRIMS

PC-125x Counter-Balanced Backdraft Damper

R & S Manufacturing and Sales Company

600 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS

SolarSheat Wall Installation Manual

HLS House Lighting System SURFACE MOUNT, 2-CIRCUIT REMOTE POWER SUPPLY

SERIES 4SQLBV OPEN Lumen Bridgelux LED Recessed Downlight

400 SERIES STANDARD DUTY STRAIGHT TRACK INSTALLATION INSTRUCTIONS

SERIES 6VLFL2X Lensed LED Downlight Lumen Flex

2-125-T Deep Aurora BRO

4DR 4.5 Downlight Round

Running Magnet 2.0 Surface High-tech LED lighting system for interior architecture

Wall/Slot -II 85N Recessed Perimeter

NAILCLMP-Nail Clamps RW List Prices - Page J-1

Technical Data Sheet Signature 841

4DR 4.5 Downlight Round

ENCLOSURES & PANELS. The Trusted Source for Innovative Control Solutions

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

NRM2-511 / NRM2-512 / NRM2-518

REVISION DESCRIPTION: REV 2: Steps re-written for clarity REV 2: Steps re-written for clarity.

NON-SIZED SIZED HANDED

A. This Section includes the following types of sectional overhead doors:

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

L10 - L40: 5-3/4 L50 - L60: 6-1/ K K K F OF 1/2. 65 Open. CG Champagne gold anodize for shower. 45 Open

SLIM PENDANT DIRECT. Project. Type. Notes. Ordering Guide PERFORMANCE PER LINEAR FOOT AT 3500K 1 / 8. axislighting.com. Shown with VL optic

Acoustical. Pages Watch for this icon for compatibility with new taller grid profile. Ph:

Specialties Inc. DISCLAIMER TABLE OF CONTENTS

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K F. 65 Open. SPC Clear specular anodize for shower

4DS 4.5 Downlight Square

AC-20 Multi Point Actuator

LCN 4040SE SERIES FEATURES HINGE (PULL) SIDE MOUNTING

Running Magnet 2.0 Surface High-tech LED lighting system for interior architecture

Tubular Daylighting Device with Proven Performance

Opticom Rack Mount Fiber Enclosures

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

HCB-8 AFTER BLENDING. Servoreeler vertical cradle support Registration slots in adapter bracket

SUBMITTAL SHEET Panel Radiator Model PR

Estimated Cable Fill Width in (mm) in 2 mm 2.30 OD. Cable Fill Area

WESTERN SPECIFIER. Technical Data for PWI Joists, PWLVL Headers, Beams, Rim Board, Stud, and Dimension

Rittling Econoline Enclosures

4' x 10' Assembly Instructions. We re Here To Help! Call Toll Free Section Roll In Dock Shown

INSTALLATION & OWNER S MANUAL

SAS International +44 (0) tubeline. tubular linear ceiling

2-520-T Miro XTM FEATURES

SUT-450-I ASSEMBLY REQUIREMENTS

MÜPRO. One-piece pipe clamps. Sprinkler pipe clamps. Refrigerant pipe clamps. Two-piece pipe clamps. Heavy-duty pipe support/din pipe clamps

Fluorescent Slot, Regressed Lens with MR16 Splay Aperture. Plaster Flange Flangeless. Donn Fineline Armstrong Bolt. Flange (All Ceilings)

G2.1 RETROFIT LED LIGHTING

AUDIO & VIDEO SOLUTIONS

M36 LED Recessed Quickship

Installation Instructions

SHOW YOUR PROFILE WITH OCTANORM ALUMINIUM PROFILES Overview of OCTANORM's extensive collection of extrusions. Product is sorted by function and form.

6DS 6 Downlight Square

1Unpack fixture. Suspensions/canopies are ordered and

3.25, 4.5, 7.5 Tabletop Conveyor Specifications

Tri-Boro Shelving Features

4DS 4.5 Downlight Square

Standard Installation Fire Damper Models: 319, 319(SS), D39

Price O.R. Systems AIR CURTAIN SYSTEM

NON-SIZED SIZED HANDED

Transcription:

3 " NOM. 316 G, ER V RO N HA. TYP SEE DETAILS A1.7 THROUGH A1.10 FOR FIXTURE OPENING RECOMMENDATIONS IE ARR XC 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS SEE DETAIL A1.2 A "M 1'-0 300C PANEL SPLICE SEE DETAIL A1.3 300C SYSTEM PROFILE 13" NOM. 1116 TYPICAL SYSTEM SECTION SEE DETAIL THIS SHEET DETAIL AX "M 4'-0 GER N HA E WIR P., TY G CIN SPA 300C PANEL SEE DETAIL A1.1 WALL ANGLE SEE DETAIL A1.5 WALL ANGLE SEE DETAIL A1.5 4'-0 "M SPA CIN G, TY P. 3 0 3'-0 0C " M PAN IN - EL 19' LENG -8" TH MA X 0 11 C P -1 AN 3/ E 16 L W "N I OM DTH. IER FLOATING TRIM SEE DETAIL A1.6 TRIM NOT SHOWN FOR CLARITY 30 PANEL BUTT JOINT SEE DETAIL A1.4 AX CAR R PAN SUSPENSION REQUIREMENTS SEE DETAIL A1.2 "M -0 2' EL O VER AX HA N G, T YP. INTERIOR INSTALLATION All rights reserved. T his dr awing is the pr oper ty of H unt er Dougl as. I t may not be copi ed or mult i pl i ed, nei t her no t b e su bmi t t e d f o r per usal to thir d par ties. OVERALL ISOMETRIC VIEW PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.0

3 16 3 " NOM. SYSTEM HEIGHT 1 16 3 " PANEL HEIGHT 1 16 3 " PANEL HEIGHT PERFORATION #160 AT FACTORY PANEL END 3'-0" MINIMUM PANEL LENGTH 19'-8" MAXIMUM PANEL LENGTH** 11 25 32 " (11.81) PANEL WIDTH ONLY NON-PERFORATED FACTORY PANEL END FACTORY PANEL SIDE VIEW *VERTICAL SUPPORT OMITTED FOR CLARITY **PANEL LENGTHS VARIABLE IN 1/8" INCREMENTS, TOLERANCE ±1/8" FACTORY PANEL ENDS *SUSPENSION OMITTED FOR CLARITY 11 25 32 " (11.81) PANEL WIDTH 300C PANEL MATERIAL THICKNESS.028" ALUMINUM 300C PANEL FINISHES PAINTED & POWDER COATED PERFORATION DIRECTION DECORATED WOOD FINISH (POWDER COATED) WOOD VENEER PERFORATION #160 PERF AREA 23% OPEN HOLE DIAMETER 0.060" AVAILABLE PANEL PERFORATION of H unter Dougl as. It not be submi t ted f or PANEL SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.1 SCALE: NTS DATE: 8/15/16

4'-0" MAX HANGER WIRE SPACING, TYP. 12 GA HANGER WIRE, BY OTHERS, NOT BY HUNTER DOUGLAS NOTE: S ARE DIRECTIONAL, CHECK ORIENTATION PRIOR TO INSTALLATION SIDE VIEW OF WITH PANEL 1'-0" MAX CARRIER OVERHANG, TYP. SIDE VIEW OF END VIEW OF WITH PANEL 300C PANEL 4'-0" MAX CARRIER SPACING, TYP. END VIEW OF 2'-0" MAX PANEL OVERHANG, TYP. MATERIAL: FINISH: PART LENGTH:.040" ALUMINUM MATTE BLACK 16'-0" of Hunter Douglas. It not be submitted f or SUSPENSION SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.2 SCALE: NTS

12" MAXIMUM AT CARRIER SPLICE 12" MAXIMUM AT CARRIER SPLICE CARRIER SPLICE 12 GA HANGER WIRE, NOT BY HUNTER DOUGLAS 12"MAXIMUM AT CARRIER SPLICE 300C PANEL 3 16 3 " NOM. 12"MAXIMUM AT CARRIER SPLICE 12 GA HANGER WIRE, NOT BY HUNTER DOUGLAS SECTION - SNAP SPLICE TABS INTO 300C CARRIER IF THE DESIRED CARRIER LENGTH EXCEEDS THE MAXIMUM OF 16'-0", USE A LUXALON CARRIER SPLICE, TO CONNECT TWO FACTORY CARRIER ENDS. THE TABS OF THE SPLICE SNAP INTO THE HOLES IN THE CARRIER AND ADDITIONAL FIXING IS NOT NECESSARY. THE MODULE IS CONTINUED AUTOMATICALLY. INTERIOR INSTALLATION of H unter Douglas. It CARRIER SPLICE PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.3 DATE: 8/15/16

4'-0" MAX CARRIER SPACING, TYP. 12 GA HANGER WIRE BY OTHERS, TYP. 24" MAXIMUM PANEL OVERHANG 24" MAXIMUM PANEL OVERHANG 300C PANEL DO NOT FASTEN PANEL ENDS TOGETHER. DOING SO WILL CAUSE DEFORMATION IN PANEL FACE. INTERIOR INSTALLATION ISOMETRIC VIEW OF FACTORY PANEL ENDS AT JOINT *CARRIERS NOT SHOWN FOR CLARITY NOTE: 300C PANEL ENDS MUST BUTT AT FACTORY PANEL ENDS AND PANELS CANNOT BE SPLICED. PANEL ENDS CAN ONLY BE FIELD CUT AT PERIMETERS WHERE TRIMS ARE USED FOR TERMINATIONS. PANEL SPLICES ARE NOT REQUIRED NOR AVAILABLE. of H unter Douglas. It PANEL BUTT JOINT PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.4

FIELD MITER TRIMS AT CORNERS SUSPENSION NOT SHOWN FOR CLARITY FIELD CUT 300C PANEL ENDS FOR LENGTH FIELD CUT 300C PANEL SIDES FOR WIDTH USE WALL ANGLE AS HOLD DOWN CLIP FIELD CUT 300C PANEL SIDE SECTION VIEW AT WALL ANGLE & 300C PANEL SIDE USE WALL ANGLE TO SECURE CUT PANEL SIDE. TYPICALLY NOT REQUIRED AT FIELD CUT PANEL ENDS. FACTORY PANEL ENDS DIRECT FASTEN WALL ANGLE TO STRUCTURE WALL ANGLE WALL ANGLE 12'-0" PART LENGTH FACTORY PANEL ENDS INTERIOR INSTALLATION *VERTICAL SUPPORT OMITTED FOR CLARITY of H unter Dougl as. It may not be copi ed or m u l t i p l i e d, ne i t h e r not be submi t ted f or WALL ANGLE TRIM PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.5 SCALE: NTS DATE: 8/15/16

2-1/4" 2 1 4 " 3-3/16" 12 GA HANGER WIRE, NOTCH TRIM AS NECESSARY, TYP. FIELD CUT 300C PANEL ENDS FIELD MITER TRIMS AT CORNERS FASTENERS TO SECURE 300C J-TRIM TO CARRIER BY OTHERS, TYP. FIELD CUT 300C PANEL SIDES FOR WIDTH FIELD CUT PANEL SIDE USE TRIM ANGLE AS HOLD DOWN 3 16 3 " DOUBLE-SIDED ADHESIVE TO SECURE TRIM ANGLE FIELD CUT PANEL END SECTION SCALE: 6" = 1'-0" SECTION SCALE: 6" = 1'-0" WALL ANGLE TO SECURE FIELD CUT PANEL SIDE. TYPICALLY NOT REQUIRED AT FIELD CUT PANEL ENDS & FULL PANEL EDGES. 2-1/4" 3-3/16" 300C J-TRIM FOR FLOATING CONDITION 10'-0" PART LENGTH FULL 300C PANELS INTERIOR INSTALLATION *VERTICAL SUPPORT OMITTED FOR CLARITY of H unter Dougl as. It m ul t i p l i e d, n e i t h er not be submi t ted f or FLOATING TRIM PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.6 SCALE: NTS DATE: 8/15/16

MAX LENGTH VARIES BASED ON PANEL LENGTH INTERRUPT CARRIER AT FIXTURE LOCATION, TYP. 2" MIN FROM PANEL END, TYP. ROUND OPENINGS FOR CAN LIGHTS, SPEAKERS, SPRINKLERS, ETC. 8" MAX WIDTH CENTERED IN PANEL RECOMMENDED MAX VARIES BASED ON PANEL LENGTH 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 300C PANEL FIELD CUT FOR FIXTURE OPENING 2" MIN FROM PANEL END, TYP. RECOMMENDED 8" MAX WIDTH FOR FIELD CUT OPENING CENTERED IN PANEL INTERRUPT CARRIER AT FIXTURE FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS BEYOND FIELD CUT 300C PANEL FIELD CUT 300C PANEL SECTION - SECTION - NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIM FOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS of Hu nter Douglas. It FIELD CUT PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.7

INTERRUPT CARRIER AT FIXTURE LOCATION, TYP. MAX LENGTH VARIES BASED ON PANEL LENGTH VARIES TO ACCOMMODATE FIXTURE WIDTH 11.81 MAX WIDTH TO REMAIN ON MODULE MAX VARIES BASED ON PANEL LENGTH FACTORY 300C PANELS 11.81 MAX WIDTH TO REMAIN ON MODULE INTERRUPT CARRIER AT FIXTURE FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS BEYOND FIELD CUT 300C PANEL FULL 300C PANEL FULL 300C PANEL SECTION - SECTION - NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of H unter Douglas. It INTERRUPTED PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.8

MAX WIDTH VARIES BASED ON PANEL LENGTH MAX LENGTH VARIES 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. 2" MIN FROM PANEL SIDE, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES BASED ON PANEL LENGTH FIXTURE CUT IN 300C PANEL FACE MAX WIDTH VARIES 2" MIN FROM PANEL SIDE, TYP. 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. CONTINUOUS 300C CARRIER BEYOND FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIELD CUT 300C PANEL FIELD CUT 300C PANEL SECTION - SECTION - NOTE: ROUND OPENINGS LESS THAN EIGHT (8) INCHES DIAMETER TYPICALLY FIELD CUT INTO PANEL FACE, TRIM FOR ALL FIXTURES BY OTHERS NOT BY HUNTER DOUGLAS of Hu nter Douglas. It FIELD CUT PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.9

4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES PANEL LENGTHS FACTORY FABRICATED TO MAINTAIN PANEL SEAM MODULE MAX LENGTH VARIES BASED (PANEL WIDTH) ON 11.81 INCREMENTS FACTORY FULL 300C PANELS 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. MAX WIDTH VARIES BASED ON 11.81 INCREMENTS (PANEL WIDTH) OPENING WIDTH VARIES 4'-6" MAX CARRIER SPACING ALLOWABLE AT FIXTURES, TYP. CONTINUOUS 300C CARRIER BEYOND FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FIXTURE TO BE INDEPENDENTLY SUPPORTED BY OTHERS FULL 300C PANEL FULL 300C PANEL SECTION - SECTION - NOTE: FIXTURE WITH TRIM FLANGE NOT BY HUNTER DOUGLAS of H unter Douglas. It INTERRUPTED PANEL FOR FIXTURE OPENINGS PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.10

COMPRESSION STRUT SPLAYED 12 GA HANGER WIRE, BY OTHERS, TYP. 45 45 N E 45 45 W S 300C PANEL LATERAL BRACING: BRACE WITH HANGER WIRES AND STRUTS PER ASTM E-580 AND IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. (4) #12 GAUGE WIRES SPLAYED 90 FROM EACH OTHER AT ANGLE NOT EXCEEDING 45 FROM PLANE OF CEILING. A STRUT FASTENED TO MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE ABOVE. SPLAYED WIRE AND STRUT BRACING TO BE PLACED NOT MORE THAN 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6 FEET FROM EACH WALL. INTERIOR INSTALLATION of H unter Douglas. It SEISMIC SPEC PROJECT: 300C PRODUCT DRAWING NUMBER: 300C-A1.11 SCALE: NTS DATE: 8/15/16