HLC A1... HLC B1... HLC F1...

Similar documents
Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

HLC A1... HLC B1... HLC F1...

PW29... Data Sheet. Single point load cell. Special Features. Optional: Dimensions (in mm; 1 mm = inches) B en

Presented By. NicolScales.com Contact Us

Load cell PR for maximum corrosion resistance. Load cell PR 6212 benefits. Mounting kit PR 6012 benefits

Compression load cell Inteco, converter Connexx, mounting kits PR 6001, PR 614x

SLB415 Load Cell. Global Usage No Compromise on Performance. SLB415 Beam Load Cells Cost Efficient Solution

Load Cells SIWAREX WL230 BB-S SA

Load Cells Bending beam load cells SIWAREX WL230 BB-S SA

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

SWC515 PinMount. Right the First Time Safe, Accurate, Service Friendly. SWC515 PinMount. Right the First Time

Superior Accuracy. Control Your Process Anytime SLB615D POWERCELL. Know What s Ahead. Superior Accuracy

SWB505 MultiMount EN1090

SLB515 Load Cell. Global Usage Fully Approved for Accuracy and Safety. SLB515 Beam Load Cell Fully Approved

SWB505 MultiMount. SWB605 PowerMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

Weighing Technology for Industry

Load Cell A special beam load cell has been developed by METTLER TOLEDO to meet hygienic criteria. Self draining and a mirror polish make it unique.

HI LPRC03 Advantage Hermetic Rocker Load Points

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

SWB505 MultiMount. Right the First Time Safe, Accurate, Service Friendly. Right the First Time

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Type Electronic Limit Switch

KD45 ±20N. Description

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Electronic Limit Switch Type

EX-REPAIR AND MAINTENANCE RECEPTACLES

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Surface thermocouple Model TC50

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Tubeskin thermocouple assembly Model TC59-V

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

KM26z 20N; 50N; 100N, 200N, 500N, 1kN, 2kN, 5kN

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

Explosion-protected surface-mounting Thermostat ATH-Ex Series

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Pressure transmitter for industrial applications Type MBS 4510

I Ex-Safety switches I

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Load Cells SIWAREX WL280 RN-S SA

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

FICHA TÉCNICA DE PRODUTO

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Pressure Transmitter JUMO dtrans p30 Type

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Tubeskin thermocouple assembly Model TC59-V

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Siemens AG kg ( lb) 130 kg ( lb) 280 kg ( lb)

Product specification

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Safety Switches Series 8537

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Series 3730 Electropneumatic Positioner Type

Product specification

Product specification

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

RC3. LOADCELLS. Technical specification. FLINTAB is exclusive importer in Romania of FLINTEC Germany products.

3/2 and 4/2 directional seat valves with solenoid actuation

Solenoid Operator 0516 / 1216

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Control and Terminal Box Type A21-**-*****

Tubeskin thermocouple assembly Model TC59-W

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

I Ex-control stations I

10 Load and Motor Switchgear

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Resistance thermometer Model TR10-E, for additional thermowell

OPTIMASS 3000 Technical Datasheet

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Cable resistance thermometer Model TR40

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Differential pressure transmitter PASCAL Ci4 Delta P

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Differential Pressure Sensors

The platform is placed on the weighing platform using three or four height-adjustable elastomer bearings (EL 120), in order to avoid twisting.

Solenoid Valve Island Type 3965

Certificate of Conformity self-generation unit

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Certificate of Conformity self-generation unit

Certificate of Conformity self-generation unit

BODAS Pressure sensor PR3 series 10

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

Measuring insert for process resistance thermometer

JUMO dtrans p20 DELTA

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

Transcription:

HLC A1... HLC B1... HLC F1... Load Cells Data sheet Special Features Hermetically encapsulated (IP68) Maximum capacities: 110 kg... 10 t Rust-resistant materials Low height of construction Meets EMC requirements as per EN 45 501 Legal for trade per OIML R60 to 6000 divisions Explosion-proof versions per ATEX 95 (optional) Cable assignment (six-wire configuration) (gray) (black) Sensing element () Excitation () (white) Signal (+) (blue) (green) (red) (stranded wire) Excitation (+) Sensing element (+) Signal () Cable shield connected to enclosure ground B2325-4.0 en 1

Dimensions (in mm; 1 mm = 0.03937 inches) K (cable length) J J HLC... B C D H G F E A HLC A1... (220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t) HLC B1... (110 kg; 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t; 10 t) M Holes only for maximum capacities 1.76 t L M HLC A1... HLC B1... N Mounting accessories for HLC B1...: see pages 4 and 5 HLC F1... (220 kg; 550 kg; 1.1 t; 1.76 t) 90 22.2 16 HLC F1... 7.7 4.8 3 17.2 Integrated overload stop Mounting accessories for HLC F1...: see page 5 Maximum capacity 110 kg; 220 kg; 550 kg; 1.1 t A B C D E F G H J K L M N 133.4 30.2 30.7 57.7 15.4 76.2 25.4 1.7 13 3 m 20.6 M12 14.2 1.76 t 133.4 30.2 30.7 51.7 15.4 76.2 25.4 1.7 13 3 m 20.6 M12 14.2 2.2 t 1) 171.5 36.5 36.8 76.2 19.1 95.3 38.1 2.5 20.5 6 m 30.2 M20 17.0 4.4 t 1) 171.5 42.9 42.9 76.2 19.1 95.3 38.1 2.5 20.5 6 m 30.2 M20 20.1 10 t 2) 245.1 72.9 60 119.9 30.2 134.9 1) Maximum capacities 2.2 t and 4.4 t only for HLC A1... + HLC B1... 2) Maximum capacity 10 t only for HLC B1 D1... 50 0.05 11.2 27 6 m 51 +0.2 32 20 Mounting accessories (to be ordered separately) According to the mounting conditions, HBM presents different, tested load applications for load cell types HLC B1... and HLC F1... (see pages 4 and 5), to minimize the effects of load application errors. HBM 2

Specifications Type HLC A1... Maximum capacity (E max ) (Load application = tapped through hole) Type HLC B1... Maximum capacity (E max ) (load application = sinking + tapped hole) 3) Type HLC F1... Maximum capacity (E max ) (Load application = blind hole + integrated overload stop) Accuracy class per OIML R60 Number of load cell verification intervals (n LC ) Minimum load cell verification interval (v min ) D1 1000 % of E max 0.0285 HLC A1 D1 /... + HLC A1 C3 /... 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t HLC B1 D1 /... 110 kg; 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t; 10 t HLC B1 C3 /... 110 kg; 220 kg; 550 kg; 1.1 t; 1.76 t; 2.2 t; 4.4 t HLC B1 C4 /... + HLC B1 C6 /... 220 kg; 550 kg; 1.1 t HLC F1 D1 /... + HLC F1 C3 /... 220 kg; 550 kg; 1.1 t; 1.76 t C3 3000 C4 5) 4000 0.0100 (220 kg; 1.76 t; 2.2 t; 4.4 t) 0.0090 (110 kg, 550 kg + 1.1 t) Nominal (rated) sensitivity (C N ) mv/v 1.94 (10 t = 2.00 mv/v) Sensitivity tolerance % 0.5 0.1 Temperature coefficient of zero signal (TC 0 ) % of C n / 10 K 0.0400 0.0140 (220 kg; 1.76 t; 2.2 t; 4.4 t) 0.0126 (110 kg, 550 kg + 1.1 t) Temperature coefficient of sensitivity (TC S ) 4) 0.0420 0.0140 0.0105 0.0070 Relative reversibility error (d hy ) 4) 0.0500 0.0166 0.0125 0.0083 Non linearity (d lin ) 4) 0.0500 0.0170 0.0166 % of C Creep upon loading (d n cr ) over 30 min. 0.0500 0.0166 0.0166 0.0122 Minimum dead load output return (MDLOR) 0.0500 0.0166 0.0125 0.0083 Input resistance (R LC ) 350... 480 Ω Output resistance (R 0 ) 350 2 350 0.12 Reference voltage (U ref ) 5 Nominal (rated) supply voltage range (B U ) V 0.5... 15 ( Ex versions max. 12 V!!! ) 5... 10 Insulation resistance (R is ) GΩ > 5 Nominal (rated) ambient temperature range (B T ) 10... +40 Operating temperature range (B tu ) C 30... +70 Storage temperature range (B tl ) 50... +85 Limit load (E L ) 150 Limit lateral loading (E lq ) 100 % Breaking load (E d ) of E 300 max Relative perm. vibrational stress (F srel ) (oscillation width per DIN 50100) 70 Nominal (rated) displacement at E max (s nom ), approx. mm 0.5 (1.76 t = 1.4 mm) Weight (G), approx. kg 0.9 (110 kg... 1.76 t); 1.6 (2.2 t); 2.2 (4.4 t); 6.2 (10 t) Degree of protection per EN 60 529 (IEC 529) IP68 Material: Measuring body Cable entry Cable sheath stainless steel 6) stainless steel 6) / seal: Viton PVC 3) Maximum capacity 10 t: Load application = sinking + tapped hole 4) The values for non-linearity (d lin ), relative reversibility error (d hy ) and temperature coefficient of sensitivity (TC S ) are recommended values. The sum of these values is within the cumulated error limit laid down by OIML R60. 5) Accuracy classes C4 and C6 only for HLC B1... / 220 kg; 550 kg; 1.1 t 6) As per EN 10088-1 C6 5) 6000 Mounting accessories (to be ordered separately) According to the mounting conditions, HBM presents different, tested load applications for load cell types HLC B1... and HLC F1... (see pages 4 and 5), to minimize the effects of load application errors. 3 HBM

Accessories for HLC B... (to be ordered separately; Dimensions (in mm; 1 mm = 0.03937 inches)) HLCB/PCX/1.76 t Oscillating loading foot (stainless steel) for HLC B / 110 kg... 1.76 t, suitable up to accuracy class C6: HLCB/ZFP/1.76 T Oscillating loading foot (stainless steel) for HLC B / 110 kg... 1.76 t: 59.5... 65.5 * 54.5... 60.5 * 2,3 Ø50 Ø60 13 a/f 17 a/f Steel 10 Rubber plate, can be removed 65.5 72* 39 45.5* * Height adjustment 50 60 Steel Rubber Loading foot secured in load cell HLCB/ZFP/4.4 T Oscillating loading foot (stainless steel) for HLC B / 2.2 t + 4.4 t: HLCB/ZAK/1.76T Oscillating loading foot, heightadjustable (stainless steel) for HLC B 1.76 t 85.5 93 * 1) 89 96.5 * 2) 47.5 55 * 1) 51 58.5 * 2) 80 90 Steel Rubber * Height adjustment, ( 1) = Maximum capacity 2.2 t / 2) = Maximum capacity 4.4 t) 63.2 68.2 16 80 Loading foot secured in load cell 19 across flats HLCB/...T/ZEL Rubber-metal bearing (galvanized; HLCB/1.76T/ZELR made from rust-resistant material) for HLC B R X T (not for 110 kg) e Z B ZEL a Y L C Maximum permissible lateral displacement (when loaded at maximum capacity): HLCB/1.76T/ZEL: 4.5 mm HLCB/4.4T/ZEL: 8 mm HLCB/10T/ZEL: 9.5 mm Type Maximum capacity B C 0.1 L R T X Y Z a e HLCB/1.76T/ZEL HLCB/1.76T/ZELR 220 kg... 1.76 t 58.8 20 118 100 9 120 60 10 92 80 HLCB/4.4T/ZEL 2.2 t 71.2 30 152.4 125 11 150 100 10 113 100 HLCB/4.4T/ZEL 4.4 t 71.2 30 152.4 125 11 150 100 10 116 100 HLCB/10T/ZEL 10 t 85 50.8 214.9 175 13 200 100 12 167 150 HBM 4

Accessories for HLC B... + HLC F... (to be ordered separately; Dimensions (in mm; 1 mm = 0.03937 inches)) HLCB/ZDP/1.76 T Easy top Rubber-metal bearing for HLC B / 220 kg... 1.76 t (Load application: stainless steel, welding plate: galvanized) A* 12 80 60 max. 0.8 mm HLCB/ZDP/4.4 T Easy top Rubber-metal bearing for HLC B / 2.2 t + 4.4 t 72 ±0.5 * Mounting optional (Load application: stainless steel, welding plate: galvanized) B* (= condition at the time of delivery) 19 across flats 79 87 Height adjustment 12 100 76 max. 0.8 mm Height adjustment Easy top secured in load cell Welding plate (schematic top view) ZPU/1.76T: 4x M8 ZPU/2.2T + 4.4T: 4x M10 1) = maximum capacity 2.2 t 2) = maximum capacity 4.4 t HLC/ZPU/...T Mounting base / mounting kit (galvanized) for HLC B Tightening torque M A : see table Load application via: HLCB/...t/ZEL HLCB/ZDP/...t View from below G = A C D = N P HLC/ZPU/...T E F B Type Max. capacity Breaking load A B C D E F G N P M A HLC/ZPU/1.76 T 110 kg... 1.76 t 3.52 t 60.5 168 100 70 16 136 13.5 20 10 130 N m HLC/ZPU/2.2 T 2.2 t 4.4 t 81.5 212 120 84 18 175 14 25 20 400 N m HLC/ZPU/4.4 T 4.4 t 8.8 t 88 212 120 84 18 175 14 25 20 400 N m HLCF/ZKP/1.76T Oscillating loading foot, height adjustable; (stainless steel) for HLC F 1.76 t 56... 61 HLC F Loading foot secured in load cell 19 across flats 16 80 5 HBM

HLC load cells, optional versions [!!! ] Order no. K HLC Code Option 1: Design A HLCA [ not with Option 3 = 10 ] B HLCB F HLCF [ not with Option 3 = 220 / 550 / 1100 / 1760 ] Code D1 C3 C4 C6 Option 2: Accuracy class D1 (OIML) C3 (OIML) [ not with Option 3 = 10 ] C4 (OIML) [ only with Option 1 = B + Option 3 = 20 / 550 / 1100 + Option 5 = S3 ] C6 (OIML) [ only with Option 1 = B + Option 3 = 20 / 550 / 1100 + Option 5 = S3 ] Code Option 3: Maximum capacity Code Option 3: Maximum capacity 110 110 kg [ only with Option 1 = B ] 1760 1.76 t 220 220 kg 2200 2.2 t [ only with Option 1 = A / B ] 550 550 kg 4400 4.4 t [ only with Option 1 = A / B ] 1100 1.1 t 10 10 t [ only with Option 1 = B ] Code Option 4: Explosion protection (per ATEX 95) N No ATEX 1 ATEX Zone 1 + 21 and FM 2 ATEX Zone 2 + 22 (non-conductive dust) Code Option 5: Cable length S3 3 m (standard) [ only with Option 3 = 110 / 220 / 550 / 1100 / 1760 ] S6 6 m (standard) [ only with Option 3 = 2200 / 4400 ] 6 6 m [ only with Option 2 = D1 / C3 + Option 3 = 110 / 220 / 550 / 1100 / 1760 ] 12 12 m [ only with Option 2 = D1 / C3 ] Code N Option 6: Other none K-HLC N Options for HLC...: Explosion protection versions per ATEX: II 2G Ex ia IIC T4 and T6 (Zone 1) *) II 2D Ex td A21 IP68 T 80 C (Zone 21) * ) * ) with ECtype examination certificate II 3G Ex na II T6 (Zone 2) II 3D Ex td A22 IP68 T 80 C (Zone 22 for non-conductive dust) Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or durability. Hottinger Baldwin Messtechnik GmbH Im Tiefen See 45 64293 Darmstadt Germany Tel. +49 6151 803-0 Fax: +49 6151 803-9100 Email: info@hbm.com www.hbm.com