GSW170I. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Similar documents
GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMS-110V. Power Rating Standby power LTP kva Standby power LTP kw Prime power PRP kva Prime power PRP kw 81.14

GSW80I. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW145V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW570M. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW275P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW415V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW555V. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

GSW415P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase 3

MSW Series P. Main applications: Construction Mobile Workshop Emergency stand-by (residential / industry) Island/Mains synchro (from 100kVA)

GSW870M. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

MSW Series V. Main applications: Construction Mobile Workshop Emergency stand-by (residential/industry) Island/Mains synchro

GMR - 67P 67P 09/05/2016 GMR - 067P

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GQW1400V. 1MWe TWINGEN in container 20 HC

P6000s 230V 50Hz #CONN #DPP

THE COMPLETE PETROL PACKAGE

MODEL GSW Deutz.

P V 50HZ #CONN #DPP

SG101TDA 102,5 (82,0) 108,1 (86,5) 0, ,6 mm Water. Water n disp. 112,0 l/h 91,1 23,0 28,0 217.

S V50HZ #AVR #CONN #DPP

MODEL GSW80 Deutz & 110 Perkins.

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

MODEL GBW15-22 Yanmar

Rating Definitions and Conditions

Rating Definitions and Conditions

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

1 / Genset general description

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Model NA 2 L

Standby Amper VOLTAGE

EN-GM GENERAC MOBILE PRODUCTS 50Hz POWER GENERATORS GENERAL CATALOGUE

Rating Definitions and Conditions

Model MP150 W W

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

1 / Genset general description

Rating Definitions and Conditions

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

GE.PK.022/020.SS+0_all

Rating Definitions and Conditions

Standby Amper VOLTAGE

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

TECHNICAL SPECIFICATIONS

Standby Amper VOLTAGE

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

1 / Genset general description

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Better Soundproof, Better Life!

PERKINS MECC ALTE P CM control system. This generator set is manufactured in facilities certified to ISO Continuous Rating (CRP) Voltage

GAS MODEL SERIES: HFGE/O 16.5kW 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

19 KW / 24 KVA POWERED by

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

CUKUROVA GENERATOR SYSTEMS

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

The GRW Series Designed for rental businesses POWER FOR RENT

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

kva kw kva kw N/A K.U.N.Z. Handels-&Produktions GmbH

Super Silent, Superior Life!

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

Voltage. kva kw kva kw

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

DIESEL GENERATOR SET MTU 12V1600 DS660

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Rental Power QSL9 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Transcription:

GSW170I Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 164.00 Standby power LTP kw 131.20 Prime power PRP kva 158.00 Prime power PRP kw 126.40 Ratings definition (According to standard ISO8528 1:2005) PRP - Prime Power: It is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufacturer. The permissible average power output over 24 h of operation shall not exceed 70 % of the prime power. LTP - Limited-Time running Power: It is defined as the maximum power available, under the agreed operating conditions, for which the generating set is capable of delivering for up to 500 h of operation per year (whose no more than 300 for continuative use) with the maintenance intervals and procedures being carried out as prescribed by the manufacturers. No overload capability is available.

Engine specifications Engine manufacturer Model [50Hz] Exhaust emission level Engine cooling system Nr. of cylinder and disposition FPT NEF67TM3A Stage II Water 6 in line Displacement cm³ 6700 Aspiration Speed governor Turbocharged aftercooled Mechanical Prime gross power PRP kw 142.7 Maximum gross power LTP kw 157 Oil capacity l 17.2 Lube oil consumption @ PRP (max) % 0.1 Coolant capacity l 12 Fuel Diesel Specific fuel consumption @ 75% PRP g/kwh 213.8 Specific fuel consumption @ PRP g/kwh 212.7 Starting system Electric Starting engine capability kw 3 Electric circuit V 12 Standards Class G2 of ISO 8528 standard certification of excellent performance related to load acceptance. Injection system The system, is based on direct fuel injection for accurate fuel delivery and is consistent with standard andalternative fuels. Air handling NEF series engines are available in Naturally Aspirated, turbocharged and turbocharged with aftercoolerversions in order to reach the highest engine performance in terms of load acceptance & fuel consumption. 600h Oil interval change NEF series adopt combustion chambers optimized to reduce oil dilution and are designed with anoptimum engine design in terms of mechanical clearances, piston rings and engine oil system calculation. Engine design Balancer counterweights incorporated in crankshaft webs, rear gear train layout, camshaft in crankcase,suspended oil pan, ladder frame cylinder block

Alternator Specifications Brand Mecc Alte Model ECP34-2L Voltage V 400 Frequency Hz 50 Power factor cos ϕ 0.8 Type Brushless Poles 4 Voltage regulation system Electronic Standard AVR DSR Voltage tolerance % 1.5 Efficiency @ 75% load % 93.5 Class H IP protection 23 Mechanical structure Robust mechanical structure which permits easy access to the connections and components during routine maintenance check-ups. Voltage regulator Voltage regulation with DSR. The digital DSR controls the range of voltage, avoiding any possible trouble that can be made by unskilled personnel. The voltage accuracy is ±1% in static condition with any power factor and with speed variation between 5% and +30% with reference to the rated speed. Windings / Excitation system Generator stator is wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th ) harmonics on the voltage waveform and is found to be the optimum design for troublefree supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches. MAUX (Standard): The MAUX MeccAlte Auxiliary Winding is a separate winding within the main stators that feeds the regulator. This winding enables to take an overload of 300% forced current (short circuit maintenance) for 20 seconds. This is ideal for motor starting requirements. Insulation / Impregnation Insulation is of class H standard. Impregnation is made with premium tropicalised epoxy resins by dipping and dripping. High voltage parts are impregnated by vacuum, so the insulation level is always very good. In the high-power models, the stator windings undergo a second insulation process. Grey protection is applied on the main and exciter stator to give enhanced protection. Reference standards Alternator manufactured according to, and complies with, the most common specification such as CEI 2-3, IEC 34-1, EN 60034-1, VDE 0530, BS 4999-5000, CAN/ CSA-C22.2 No14-95-No100-95.

Genset equipment BASE FRAME MADE OF WELDED STEEL PROFILE, COMPLETE WITH: Anti-vibration mountings properly sized Welded or Screwed support legs. (according to canopy size) PLASTIC FUEL TANK WITH THE FOLLOWING COMPONENT: Filler neck Air breather (ventilation pipe) Minimum fuel level sensor OIL DRAININ PIPE WITH CAP: Oil draining facilities ENGINE COMPLETE WITH: Battery Liquids (no fuel) CANOPY: Soundproof canopy made up of modular panels, realized with zinced steel as treatment against corrosion and aggressive conditions, properly fixed and sealed allowing a full weatherproof enclosure. Easy access to the genset for maintenance purposes thanks to: Wide lateral access doors fixed by stainless steel hinges and provided with plastic lockable handles; Detachable panels, with screws holes protected by rubber tap. Control panel protection door provided with suitable window and lockable handle. Lateral air inlet opening properly protected and soundproofed. Exhaust air outlet from the roof, trough wet section protected by proper grid. Single detachable lifting eye placed on the roof. SOUNDPROOF: Noise attenuation thanks to soundproofing material (rock wool) Efficient residential silencer placed inside the canopy

Dimensional data Length (L) mm 3400 Width (W) mm 1250 Height (H) mm 1770 Dry weight Kg 2057 Fuel tank capacity l 350 Autonomy Fuel consumption @ 75% PRP l/h 27.08 Fuel consumption @ 100% PRP l/h 35.61 Running time @ 75% PRP h 12.92 Running time @ 100% PRP h 9.83 Noise level Guaranteed noise level (LWA) db(a) 96 Noise pressure level @ 7 mt db(a) 67 Installation data Total air flow m³/min 257.09 Exhaust gas flow @ PRP m³/min 29 Exhaust gas temperature @ LTP C 570 Data Current MAX current A 236.72 Circuit breaker A 250 Control panel availability MANUAL CONTROL PANEL MCP MANUAL CONTROL PANEL FULL OPTION MPF AUTOMATIC CONTROL PANEL ACP MODULAR PARALLEL PANEL MPP

MCP - Manual control panel Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle. INSTRUMENTATION (ANALOGUE) Voltmeter (1 phase) Ammeter (1 phase) Hours-counter COMMANDS Start/stop selector switch with key Emergency stop button PROTECTION WITH ALARM Low fuel level Battery charger failure low oil pressure high engine temperature Earth Fault. PROTECTIONS WITH SHUTDOWN Low fuel level Battery charger failure low oil pressure high engine temperature. Circuit breaker protection: III poles Emergency stop button OTHERS PROTECTIONS Panel protected through door with lockable handle. OUT PUT PANEL MCP Power cables connection to Circuit Breaker. External Terminal Board (ETB) Socket kit Optional Optional

MPF - Manual control panel full option Mounted on the genset and complete of: analogue instrumentation, control, protection of the generating set, protected through door with lockable handle INSTRUMENTATION (ANALOGUE) Voltmeter with selector switch (3 phases) Frequency meter Ammeter with selector switch (3 phases) Hours-counter Fuel level indicator Oil pressure indicator Engine temperature indicator COMMANDS Start/stop selector switch with key Emergency stop button PROTECTION WITH ALARM Low fuel level Battery charger failure low oil pressure high engine temperature Earth Fault PROTECTIONS WITH SHUTDOWN Low fuel level Battery charger failure low oil pressure high engine temperature Circuit breaker protection: III poles Emergency stop button OTHERS PROTECTIONS Panel protected through door with lockable handle OUT PUT PANEL MPF ETB- External Terminal Board ETB Socket kit Standard Individual CB and Earth Fault protection 3P+N+T 400V 63A n 1 3P+N+T CEE 400V 32A n 1 3P+N+T CEE 400V 16A n 1 230V/16A 2P+T CEE n 1 230V/16A SCHUKO n 1

ACP - Automatic control panel Mounted on the genset, complete with digital control unit AC03 for monitoring, control and protection of the generating set, protected through door with lockable handle DIGITAL INSTRUMENTATION (through AC-03) Generating set voltage (3 phases) Mains voltage Generating set frequency Generating set current (3 phases) Battery voltage Power (kva - kw - kvar) Power factor Cos φ Hours-counter Engine speed r.p.m. Fuel level (%) Engine temperature (depending on model) COMMANDS AND OTHERS Four operation modes: OFF - Manual starting - Automatic starting - Automatic test Pushbutton for forcing Mains contactor or Genset contactor Push-buttons: start/stop, fault reset, up/down/page/enter selection Remote starting availability DC system disconnection switch Acoustic alarm Automatic battery charger RS232 Communication port Settable PASSWORD for protection level PROTECTIONS WITH ALARM Engine protections: low fuel level, low oil pressure, high engine temperature Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage PROTECTIONS WITH SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure Circuit breaker protection: III poles Earth Fault included in the control unit OTHERS PROTECTIONS Emergency stop button Panel protected through door with lockable handle OUT PUT PANEL ACP Plinth row for connection from ACP to LTS panel. Power cables connection to Circuit Breaker. Predisposed for remote control optional: RCG External Terminal Board (ETB) Optional Socket kit Optional

MPP - Modular parallel panel Mounted on the genset, complete with digital control unit IG-NTC for monitoring, control, protection and load sharing for both single and multiple gen-sets operating in standby or parallel modes (up to 32 gen-sets in island). DIGITAL INSTRUMENTATION (through IG-NTC control unit) Mains: voltage, Intensity, Frequency. Mains kw - kvar -Power factor Cos f. Genereting set voltage (3 phases). Generating set frequency. Generating set current (3 phases). Generating set Power (kva - kw - kvar). Generating set Power factor Cos f. Generating set kwh and kvah. Battery voltage. Hours-counter. Engine speed r.p.m. Fuel level (%). Engine temperature (depending on model). Oil pressure (depending on model). COMMAND AND OTHERS Graphical display 128x64 pixels. Operation modes: OFF - AMF function - Single Parallel to mains Island application - Single Parallel to Mains AMF application - Mulitple parallel genset Island application. Pushbutton for forcing Mains Breaker/contactor or Genset Breaker/contactor. Push-buttons: start/stop, fault reset, up/down/page/enter selection. Multiple parallel and Power Management operation with digital load AVR sharing. Automatic synchronizing and power control (via speed goveroner or ECU) Baseload Import/Export and Peak shaving Voltage and PF control (AVR). Configurable digital I/O (12/12) and analogue inputs (3). Integrate PLC programmable functions. Event-based history (up to 500records). Selectable measurment range 120/277V and 0-1/0-5A. Remote starting and Blocking signal availability. DC system disconnection switch. Acoustic alarm. Automatic battery charger. 2xRS232/RS485/USB Comuncation ports. Setable PASSWORD for protection level. PROTECTION WITH ALARM AND SHUTDOWN Engine protections: low fuel level, low oil pressure, high engine temperature. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage Others: overcurrent, shortcircuit, reverse power, Earth fault OTHERS PROTECTION: Circuit breaker protection: IV poles Motorized. Emergency stop button. Panel protected through door with lochetable handle OUT PUT PANEL MPP Multi-pin connectors (in and out ) for parallel with other generators n 2 Connecting cable with 2 connectors multipin (length 10m) n 1 ETB External terminal board ETB

Supplements: Only Available when order : CONTROL PANEL SUPPLEMENT RCG - Various supplements for remote controls - available for models: TLP - Various supplements for remote signals - available for models: ADI - Adjustable Differential Intensity - available only for models: TIF - IV Poles Circuit Breaker instead of III - available for models: ETB - External Terminal Board - available for models: ACP MPP ACP MPP ACP ACP MCP MCP ACP Socket kit SKB socket kit B - available for models: ACP MCP Individual CB and Earth Fault protection 3P+N+T 400V 63A n 1 3P+N+T CEE 400V 32A n 1 230V/16A 2P+T CEE n 1 230V/16A SCHUKO n 1 NB: for assembly is necessary: ETB 3P+N+T CEE 400V 16A n 1 GENSET EQUIPMENT KPR - Premium Kit (Leak Proof Tray - Leakage detection sensor - Manual oil drain pump) AFP - Automatic Fuel Pump KRT - Kit Rental which includes fuel filter with water separator, 3-way fuel valve, battery switch, earth rod, docs folder) ACP MPP Extended Fuel Tank Fuel tank capacity l 1750 Length (Genset) (L) mm 3414 Width (Genset) (W) mm 1398 Height (Genset) (H) mm 2539 ENGINE SUPPLEMENTS PHS - Coolant Pre-Heating System - available for models: EEG - Engine Electronic Governor ACP MPP

Accessories Items available as accessory equipment STR - Site trailer RTR - Road Trailer LTS - LOAD TRANSFER SWITCH - Accessories ACP Automatic under-load change-over (AC22, AC23) from and to any of positions 1, 0, 2 both electrical and manual (emergency change-over), transfer function with direct transition from position 1 to position 2 and vice versa. Safety: locking by padlock preventing any electrical or manual operation, key lock for the selection of electrical or manual operation.- Quick operating time from pos. 1 to 2 and vice versa. Easy and fast electrical connections by means of terminal blocks of quick connection type. Conformity to standards: IEC 60947-1 IEC 60947-3, CEI EN 60947-1 / CEI EN 60947-3IEC 439-1, CEI EN 60439-1IEC 204-1, CEI EN 60204-1, VDE 0660 Teil 107 NOMINAL CURRENT & DIMENSIONS PANEL LTS (standard*) Nominal Current A 250 Width (W) mm 600 Height (H) mm 400 Depth (D) mm 200 * = Available electrical power more Printed on 11/03/2016 (ID 2050) 2012 PR INDUSTRIAL s.r.l. All rights reserved Image shown may not reflect actual package. Specifications subject to change without notice ENERGY GENERATION is registered trademarks of PR INDUSTRIAL s.r.l. Other company, product or service names may be trademarks or service marks of others. RevA (06/2012).