Specifications. Standard MMG100D** MMG130D** MDG150DF4

Similar documents
Magnum Mobile Generator MMG175 Specifications

Mobile Generator MMG75D Specifications

Magnum Mobile Generator MMG330 Specifications

Mobile Generator MMG130 Specifications

MMG45IF4. Mobile Generator. Engine. Generators. System Output. System Controls MMG45IF4

Mobile Generator MMG130 Specifications

Magnum Mobile Generator MMG75 Specifications

Magnum Mobile Generator MMG125 Specifications

Magnum Mobile Generator MMG75 SS Specifications

Magnum Mobile Generator MMG235 Specifications

Mobile Generator MMG25FHI Specifications

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

Mobile Diesel. Generators

Magnum Mobile Flip-Hood Generators Model MMG 45 (pages 4-7) Magnum Mobile Generators Model MMG 100 (pages 4 7)

customer driven unsurpassed value

MOBILE DIESEL GENERATORS

DCA400SSI4F. WhisperWatt 400. MQ POWER Whisperwatt Series. Prime Rating 320 kw (400 kva) Standby Rating 336 kw (420 kva)

Magnum Combination Unit MTT25 Specifications

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

10,000 Watt Diesel Generator AGi9P E

13,000 Watt Diesel Generator AGi13P E

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

The power to evolve. QAS generators

Standby. Speed rpm 60 Hz 480/277V 30 (38) 27 (35) Hz 208/120V 30 (38) 27 (35) Hz 240/120V 30 (30) 27 (27) 1800.

RENTAL DIESEL GENERATOR SET

150 KW / 195 KVA. POWERED by TP-JDR150-T3F-60. kva 194 Standby 3 Phase - Switchable kw /208, 110/220, 120/240, 277/480

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Multiple voltage 45kVA prime power Isuzu engine

FLORIDA SHERIFFS ASSOCIATION & FLORIDA ASSOCIATION OF COUNTIES

POWERBLOCK GENERATION SYSTEMS

DIESEL GENERATOR MMG130D MMG175 MMG205

GENERATORS. Mobile Full Line

DIESEL GENERATOR MMG120 MMG150 MMG150D MMG170 MMG185D MMG235

45 KW / 55 KVA POWERED by

60 Hz FEATURES. Exclusively from your Caterpillar dealer

LED Runway Closure Marker RCM-D

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

KOHLER MOBILE GENERATORS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

BID SPECIFICATIONS FOR (1) 300kW STANDBY GENERATOR

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

APD-ULJ250. Standby Power

MOBILE GENERATORS R E L I A B L E F L E X I B L E A V A I L A B L E D U R A B L E

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Rental Power QSB7 series engine

80kW Standby / 70kW Prime Power Towable Generator

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

28 KW / 28 KVA POWERED by

XQ175 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

DIESEL GENERATOR MMG75D MMG100D

DIESEL GENERATOR SETS

DIESEL GENERATOR MMG120 MMG150D MMG185D MMG235

XQ 200 R E N T A L. STANDBY 200 kw PRIME 182 kw. POWER MODULE 60Hz 1800 rpm 480V FEATURES

30kW Standby / 27kW Prime Power Towable Generator

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Godwin Hush-Power Generators

Standby kw (kva) 480V 60 Hz Rating

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

Rental Power QSL9 series engine

XQ80 RENTAL. 60 Hz FEATURES

Standby kw Prime kw

600 KW / 750 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

DIESEL GENERATOR SET. 60 Hz FEATURES

Trailer Mounted Light Towers

23 KW / 29 KVA POWERED by

55 KW / 70 KVA POWERED by

Bid Specifications HP935WCU PORTABLE AIR COMPRESSOR

Rental Power 800 kw. Specification sheet. Description. Features. Options

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

130 KW / 165 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Standby Amper VOLTAGE

APS100 Rental Generator Set Preliminary Specification

D I E S E L G E N E R A T O R S E T S

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

1000 KW / 1250 KVA POWERED by

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

customer driven unsurpassed value

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

XQ60 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

SPECIFICATIONS. File _RDA150T3_SA200

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

WPS60/S EP Series. Features:

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

400 KW / 500 KVA. POWERED by TP-JD400-T3-60-UL. kva 500 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

2000 KW / 2500 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel generator set QSX15 series engine

8,000 Watt Diesel Generator

Transcription:

Specifications Standard MMG100D** MMG130D** MDG150DF4 Output 3 Phase - Standby (kw/kva) 86 / 107 107 / 134 145 / 181 Amps (480/208 V) 129 / 297 161 / 372 218 / 503 3 Phase - Prime (kw/kva) 78 / 98 98 / 122 120 / 150 Amps (480/208 V) 118 / 272 147 / 339 180 / 416 1 Phase - Standby (kw/kva) 75 / 75 96 / 96 114 / 114 Amps (240V) 313 400 473 1 Phase - Prime (kw/kva) 71 / 71 90 / 90 108 / 108 Amps 296 375 450 AC Voltage 1-phase 120, 139, 208, 220, 240, 277 240 AC Voltage 3-phase 208, 220, 440, 480 208, 240, 400, 480 Frequency Hz 60 50 / 60 Power Factor 1 (1Ø), 0.8 (3Ø) Generator (Brand/Type/Insulation) Marathon/Brushless/H Sound (db(a) 23 Feet @ prime) 68 68 TBD CSA Listed No Yes Yes Size and Weight Skid Mounted ( l x w x h ) in (m) 119 x 40 x 62 (3.02 x 1.02 x 1.57) 144 x 50 x 77 (3.66 x 1.27 x 1.96) 145 x 50 x 84 (3.7 x 1.3 x 2.1) Dry Weight lb (kg) 3780 (1714) 5444 (2469) 8500 (3856) Operating Weight lb (kg) 4740 (2150) 7929 (3596) 11500 (5216) Trailer Mounted ( l x w x h ) in (m) 170 x 69 x 80 (4.32 x 1.75 x 2.03) 210 x 86 x 93 (5.33 x 2.18 x 2.36) 208 x 86 x 104 (5.3 x 2.2 x 2.6) Dry Weight lb (kg) 4480 (2032) 6840 (3102) 10000 (4535) Operating Weight lb (kg) 5440 (2468) 9325 (4230) 13000 (5897) Engine Interim Tier 4 Interim Tier 4 Final Tier 4 After-treatment Components DOC + DPF DOC + DPF SCR + DOC Brand John Deere John Deere John Deere Model # PE4045HFG92 PE4045HFG93 6068HFG05 Aspiration Turbo Turbo Turbo HP (prime @ 1800rpm) (kw) 121 (90) 152 (113) 196 (146) Displacement in3 (L) 275 (4.5) 275 (4.5) 415 (6.8) Cylinders 4 4 6 Speed (rpm) 1800 1800 1800 Fuel Consumed prime gph (Lph) 6.2 (23.5) 7.4 (28.0) 8.8 (33.2) DEF Consumed prime gph (Lph) -- -- 0.34 (1.3) Battery (12 volt) 1-12V / 720 CCA 1-12V / 1000 CCA 2-12V / 1000 CCA Capacities Fuel Tank gal (L) 165 (625) 342 (1295) 358 (1355) Approximate Run Time hrs 24 44 24 DEF Tank gal (L) -- -- 34.4 (130.4) AC Distribution Main Breaker 400 450 600 Voltage Selection 3 Position Switch (lockable) 3 Position Switch (lockable) 3 Position Switch (lockable) Voltage Regulation +/- 0.5% +/-0.5% +/- 0.5% 120V - 20 amp GFCI Duplex 2 2 2 240V - 30 amp Twist Lock N/A N/A N/A 240V - 50 amp Twist Lock 3 3 3 Trailer # of Axles & Capacity lbs (kg) 1-6000 (2722) 1-6000 (2722) 2-8000 (3629) Tire Size (in) 15 16 17.5 Brakes Surge Surge Surge Hitch Standard 3" Ring 3" Ring 3 " Ring Specifications and designs are subject to change. **Limited quantities. 800-926-9768 920-361-4442 14

ENGINE John Deere PE4045HFG92 - turbocharged, diesel engine o Prime - 121 hp @ 1800 rpm o Standby - 133 hp @ 1800 rpm o 4 cylinder o 4.5 L displacement o Interim Tier IV approved Steel, single wall fuel tank o 165 gal. (625 L) capacity o 24 hr. run time full load o Fuel tank built into skid of generator set Fuel consumption at prime: o 100% - 6.2 gph (23.5 Lph) o 75% - 4.7 gph (17.8 Lph) o 50% - 3.1 gph (11.7 Lph) Cooling system capable of operating at 120 F (49 C) ambient Radiator and oil drains plumbed to exterior Rubber vibration dampers isolate engine/generator from frame Disposable air filter - paper element 60 Hz engine/generator Electronic isochronous governing GENERATOR Marathon Electric o Brushless o 4 pole o Class H insulation Voltage regulation +/- 0.5% with Magnum PM600 Voltage Regulator SYSTEM OUTPUTS 3 position selector switch o Single phase 120 / 240V Zig Zag o Three phase 120 / 208V Low Wye o Three phase 277 / 480V High Wye 75 kw / 75 kva standby, single phase 71 kw / 71 kva prime, single phase 86 kw / 107 kva standby, three phase 78 kw / 98 kva prime, three phase Page 1 of 4

SYSTEM CONTROLS Power Zone controller and display o Backlit, 800 x 480 pixel resolution color display o -40 F to 185 F (-40 C to 85 C) operating temperature range o Automatic coarse voltage adjustment o Integrated fine voltage adjustment o PLC functionality Push buttons for easy operation o Manual or Auto Start o Engine Start o Engine Stop/Reset o Alarm Mute o Operator Screens Home Engine Generator Voltage Adjust o Scrolling Arrows for Diagnostic Information Engine diagnostic display Oil pressure Engine temperature Fuel level Battery After treatment inlet/outlet temperature Ash/soot levels Generator diagnostic display System kw output display Line output & frequency display Alarms Warning Shutdown Electrical Trip Engine Alarm list warnings / shutdowns; 250 event history log date/time stamp Fuel level: warning 15%; shutdown 5% Over speed protection: shutdown 115% Oil pressure: warning 25 psi; shutdown 20 psi Coolant temperature: warning 220 F (104 C); shutdown 230 F (110 C) Battery voltage: over 15VDC; under 11VDC Generator over voltage: warning 110%; electrical trip 111% Generator under voltage: warning 87%; electrical trip 86% Generator over frequency: warning 105%; electrical trip 110% Generator under frequency: warning 95%; electrical trip 90% Page 2 of 4

SYSTEM CONTROLS (continued) Inputs/Outputs Auto Schedule Status Configuration of controller, firmware and connections ELECTRICAL CONTROLS Remote start / stop contacts located in lug box Lockable control box door with diagnostics window Lockable lug box with safety switch o Trips main breaker when door is opened o Disables voltage regulator Output ground connection lug inside lug box 400A main breaker with shunt trip Convenience receptacles with individual breakers (restricted use in high wye mode) o (2) 120V 20 Amp GFCI duplex outlets (NEMA 5-20R type) o (3) 125 / 250V 50 Amp, 3 pole, 4 wire Twistlock (Non-NEMA 6369) Voltage adjustment integrated into Power Zone controller, +/- 10% 720CCA wet cell battery ENCLOSURE Aluminum, sound attenuated enclosure o UV & fade resistant, high temperature cured, white polyester powder paint o Insulated and baffled o 68 db(a) @ 23 ft. (7 m) prime power Fully lockable enclosure including doors and fuel fill Emergency stop switch located on outside of enclosure Central lifting point Multi-lingual operating/safety decals Document holder with operating manual including AC/DC wiring diagrams TRAILER DOT approved tail, side, brake, and directional lights; recessed rear lights Transportation tie downs Safety chains with spring loaded safety hooks 3 in. (76.2 mm) lunette ring hitch 6000 lb. (2722 kg) axle with surge brakes 3000 lb. (1361 kg) tongue jack with footplate ST225/75R15 tubeless tires 8 ply Page 3 of 4

WEIGHT & DIMENSIONS Skid mounted o Dry weight: 3780 lbs. (1714 kg) o Operating weight: 4740 lbs. (2150 kg) o 119 x 40 x 62 in. (3.02 x 1.02 x 1.57 m) Trailer mounted Dry weight: 4480 lbs. (2032 kg) Operating weight: 5440 lbs. (2467 kg) 170 x 69 x 80 in. (4.32 x 1.75 x 2.03 m) WARRANTY 2 Years / 2000 Hours CERTIFICATIONS CSA Certified Page 4 of 4