GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Air-insulated switchgear UniGear type ZS1

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS up to 40.5 kv, Gas-Insulated

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

ZX-Family Gas-insulated medium voltage switchgear

NXAirS Withdrawable Medium-Voltage Switchgear up to 24kV Air-Insulated

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Metal Clad Air Insulated Switchgear

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Unitole UP kv Primary substations Motor control centres

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Air-Insulated Medium-Voltage Switchgear NXAIR, up to 24 kv

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

NXPLUS C Single busbar. Maintenance-free for lifetime

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Gas Insulated Metal-clad Switchgear, HMGS!

Benefits, typical uses

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Fixed-Mounted Circuit-Breaker Switchgear up to 36 kv, SF 6 -Insulated

Catalog HA Edition Medium-Voltage Switchgear. siemens.com/nxair

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Metal Clad Switchgears

PIX-H Metal-clad switchgear up to 17.5kV

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

CPG.0 Single busbar gas-insulated cubicles

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

MESG 12 / 17.5 / 24 / 36 KV

the safe, reliable, and efficient choice for MV switchgear

Types. Fixed-mounted circuitbreaker. NXPLUS C is a factoryassembled,

Unitole UP kv Primary substations Motor control centres

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

ZX-Family Gas-insulated medium voltage switchgear

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

UniGear. Technical Guide

Power IT Air Insulated Cubicle Uniswitch

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

8DJ. Maintenance-free for lifetime

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Vacuum Circuit Breaker VS1

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

LKE LAURITZ KNUDSEN ELECTRIC. VECTOR series 12~24 kv VECTOR Metal-clad Switchgear & Vacuum Circuit Breaker

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

36kV Gas Insulated Medium Voltage Switchgear

Load Break Switch. Sf 6. 12~24 kv Type GLBS SF 6 Load Break Switch Type LCA-G Metal Enclosed Switchgear. Medium Voltage Systems 003 FM 73638

33KV INDOOR SWITCHGEAR

with Vacuum Circuit Breaker HAF

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

HB1 and VB1 Generator Circuit-Breaker Switchgear. Medium-Voltage Switchgear. siemens.com/generatorswitchgear. Catalog HB1 and VB1 Edition 2017

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Instruction for Installation and Operation

Medium voltage vacuum circuit breaker. E-VAC series

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Gas Insulated Switchgear

MCSG 12kV / A

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

Switchgear Type 8DJH 36 for Secondary

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Innovac SVS/08 - SVS/ kv modular switchgear

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Modular medium-voltage switchgear. NorMax

TECHNICAL MANUAL AND APPLICATION GUIDE. Engineering Your Power

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

cor Long Run Experience

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Metal Clad VCBs ~ Mk1

ZX2 Gas-insulated medium voltage switchgear

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Contents. We build a better future! MCC HCB

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

COMPACT SUBSTATION GUIDE

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Transcription:

Vacuum Circuit Breaker 12/24kV VECTOR series Vacuum Circuit Breaker VMS series Metal-clad Switchgear Medium Voltage Systems 003 FM 73638

12/24kV VECTOR VCB Features of the VECTOR Vacuum Circuit Breaker: The VECTOR is a cassette-type (withdrawable) 12/24kV Vacuum Circuit Breaker designed f the VMS metal-clad switchgear, featuring compact dimensions of the circuit breaker and switchboard panels. The VECTOR VCB has nominal current ratings of up to 2000A, with a maximum breaking capacity of 31.5 ka, and sht-time current ratings of up to 31.5 ka / 4 sec. Whereas the VECTOR-S is a spring-mechanism driven VCB, the VECTOR-M is driven by a low-energy single-coil permenantmagnet actuat system capable of me than 50,000 mechanical operations. VECTOR24-S32 VECTOR12-M32 The Vect-M is a low maintenance circuit breaker. The vacuum interrupters are maintenance-free with a minimum lifetime of 20 years. Maintenance of the operating mechanism is only required after 10 years 25,000 operations. After 40,000 switching operations a general inspection by the manufacturer is recommended. (5) (6) (1) (2) (3) (8) (9) VECTOR VCB compliance with the following standards: (7) (10) (4) IEC 298, IEC 185, IEC 282, IEC 529, IEC 186,IEC 56, IEC 129, DL 404 (14) (11) (15) Ambient conditions (12) Ambient temperature: -25 o C to +40 o C. (16) Relative humidity: daily average of less than 95% and (13) monthly average of less than 90%. Section view of VECTOR Height above sea level of less than 1000 m. Earthquake intensity less than 8 degree. Environment: no frequent violent vibration. (1)--Top termianls with lotus contacts (2)--Interrupter housing of epoxy resin (3)--Truck (4)--Lower terminals with lotus contacts (5)--Vacuum interrupter (6)--Top copper conduct (7)--Bottom copper conduct (8)--Flexible copper connection. F ratings of current 1600A & above sliding contacts are used instead. (9)-- Insulated push rod (10)--Contact load spring (11)--Actuat controller (12)--Capacit banks (13)--Permenant magnet actuat (14)--Auxilliary terminal connection block (15)--Manual trip button (16)--Position interlock

Technical parameters Electrical Characteristics Unit VECTOR12-M32 VECTOR12-S20~S32 VECTOR24-S20~S32 Rated Voltage kv 12 12 24 Rated current A 2000 1250 1250 Rated frequency Hz 50/60 50/60 50/60 Rated power-frequency withstand voltage kv 28/32 28/32 50/60 Rated Lighting impulse withstand voltage kv 75/85 75/85 125/145 Rated sht-circuit breaking current ka 31.5 20, 25, 31.5 20, 25, 31.5 Rated sht-time withstand current ka/s 31.5/4 20/4, 25/4, 31.5/4 20/4, 25/4, 31.5/4 Rated peak withstand current ka 80 80 80 Rated sht-circuit making current kv 80 80 80 Mechanical endurance cycles 20000 20000 30000 Rated Operating sequence O-0.3s-CO-180s-CO Mass kg 170 120 130 The VECTOR as the following general dimensions 600 560 190 190 600 630 697 536 600 577.5 165 210 165 210 VECTOR12 VECTOR24 585 615 285 315 250 643 613 VECTOR12-M32 649 279 250 671 540 640 570 670 608(631) * Dimensions indicated in brackets (xxx) are those of the VECTOR24 series, whereas dimensions without brackets are common to both VECTOR12 and VECTOR24.

VMS Metal-clad switchgear The type VMS metal-clad switchgear is designed f installation in distribution substations, transfmer substations, electric power stations and industrial companies. Features Air-insulated switchgear panels, metal-enclosed, metal-clad, with a single busbar system. Compact dimensioning arising from the compactness of the Vect-M/S and the combination of the terminal box, the cur rent transfmers and the voltage indicats into a single component bloc. The cable connection compartment is readily accessible through a seperate do. Ease of operation on closed front section. High staff safety through closing of the busbar compartment cladding even in service position. Reliability through effective mechanical interrogat interlocking system. Modular construction allows high fl exibility and adaptability. The design of the VMS The basic frame and suppts f mounting theincpated devices are designed as a compound construction made of welded and bolted parts. Reinfced H-frame provides the necessary robustness to withstand internal arcing. The reinfced sheet-steel do is provided with a four-point centrally controlled locking system. The withdrawable chassis is moved by means of a manual crank into the service and disconnected positions. The circuit breaker truck is placed upon the chassis in the service and disconnected positions. F removing the circuit breaker truck, it is slid from the chassis unto a transpt trolley and locked onto the trolley f transptation. The transpt trolley and thus the circuit breaker, may be moved without any other mechanical aid. Easy access to the various switching devices f routine tests even with maximum complements. Pressure relief shutters Sectionalising partition Busbar suppt bushing low voltage compartment Busbar compartment Shutters Epoxy-resin moulded Terminal box Terminal block connections f secondary circuitry Circuit breaker compartment Vect-M/S VCB truck Block current transfmers Copper f cable connections Fault-making earth switch Cable compartment Compartment f potential transfmer truck

Switchgear panel dimensions 2000 650/700 1500 Front Elevation Side Elevation Rear Elevation VMS confms to the following standards and specifications Construction and design type test, routine test Arcing resistance in compliance with Earthing Operation,control and wk near live parts Installation, building dimensions, room height in compliance with Protection categies in compliance with* Basic version To der Nmal operating conditions Metal-enclosed(M) DIN VDE 0670, part 6 IEC 298 DIN VDE 0670, part 601, IEC 298, Appendix AA Criteria 1-3,6 1s 1-6 1s DIN VDE 0670, part 6 IEC 298, VDE 0141 DIN VDE 0105, part 1 DIN VDE 0101 Closed electrical substations DIV VDE 0670, part 6 IP 2X IP 3X / IP 4X DIN VDE 0670, part 1000 DIN VDE 0670, part 6 IEC 694, IEC 298 Temperature of ambient air Relative humidity Installation altitude Maximum Mean over 24 hrs Minimum 40 o C 35 o C minus 5 o C indo (minus 25 o C with additional measures) up to 95% up to 1,000m (3,300 ft) above sea level Enquiries must be made regarding other operating conditions,e.g. higher ambient temperature,different altitude *Up to IP52 to der-where no louvres possible

Layout of standard panels Circuit-breaker panel VECTOR-M/S Vacuum circuit breaker With: With: With: Surge diverter Section isolation panel Panel 1 Vacuum Circuit-breaker Up to 3 current tranfmers Earthing switch,make-resistan Panel 2 Isolat chassis Panel 1 Circuit-breaker Switch-disconnect Up to 3 current tranfmers Panel 2 Upward feeder panel Disconnection truck Section isolation with switch-disconnect -up to 1250A - Panel 1 Section isolation with switch-disconnect Panel 2(also supplied 600mm wide) Busbar measurement truck panel/chassis panel Instrument truck panel/ Instrument chassis panel Without/with fuse-carrier Disconnection truck panel/disconnection chassis panel Busbar Up to 3 single-pole insulated voltage transfmers Up to 2 two-pole insulated voltage transfmers Earthing switch, make-resistant Up to 3 current transfmers Busbar connection(fully insulated busbar and fl at copper connection) Cable connection Up to 2 cable end boxes per phase