STABILOY BRAND FeeDeR SOLuTIONS

Similar documents
STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

ATHLETIC STADIUMS AND SPORTS ARENAS

Primary, Secondary, Post-Secondary Education Facilities

HOSPITAL AND HEALTHCARE

RENEWABLE ENERGY. Alcan cable solutions

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2


Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

The Reliable Choice. Field Pocket Guide

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

NEC 2014 Code Changes

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

Variable Frequency Drive (VFD) Cable Solutions

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

TC-RHH/RHW-2 USE-2 Copper

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

Mecklenburg County Common Code Defects

MC, THHN/THWN-2 Copper

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

National Marine Manufacturers Association Product Compliance Specialist Examination D.C. Electrical (2013 MY) ABYC E-11 (08 Amended 09)

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

MC or MV-105 Copper, TR-XLPE Insulated

Section 02: Pre-Installation Procedures

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

C-L-X Aluminum Sheath Type IEC

Code Calculations. for an Off-Grid PV System

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Variable Frequency Drive (VFD) Cable Solutions

PART A General Conductor Requirements

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

SECONDARY 600 VOLT CABLES

CHAPTER V RESIDENTIAL WIRING

HW250 REV 8/16 TYPE SOOW. 600 Volt UL/CSA, -40 C to 90 C Black Jacket Flexible Copper Conductors

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

2016 Photovoltaic Solar System Plan Review List

High Voltage Copper, Smooth Aluminum Shield/Sheath

E R C. R E R C ; ; W T E C

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Easier! Faster! Safer!

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

Section 8. Portable Cordage & Power Cable

IEEE 1580 TYPE T/N CABLE

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

MEDIUM VOLTAGE

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Wired for Power Generation

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

Medium Voltage Power Cables

Introducing. Paralleled

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

KALAS ENTERTAINMENT CABLE

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Category # 1 - Overhead, Primary, & Secondary Conductors

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

A. Submit manufacturer's literature and technical data before starting work.

Electrical Design/Build Guide

TUNNELING POWER CABLES

Metering and Control Standards OFF-PEAK & DUAL FUEL WIRING DIAGRAMS

SINGLE PHASE WIRING SPECIFICATIONS

TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

PHOTOVOLTAIC SYSTEMS

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

EV Charging Station Submittal Requirements

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Photovoltaic Solar Plan Review

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

THREE PHASE WIRING SPECIFICATIONS

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

Protecting the oil & gas industry for more than half a century!

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

Battery Cables. Wire & Cable

Spring Test 10 due 05/11/2013

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

Type MMV-WP Medium Voltage Wind Power Cable

Expedited Permitting Process for Electric Vehicle Charging Stations

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Outdoor Power Transmission & Distribution

Transcription:

STABILOY BRAND Feeder Solutions DATA CENTER

Introduction General Cable understands that data centers depend heavily on a steady, reliable and scalable source of power. That is why our STABILOY Brand aluminum alloy feeder cables are installed with confidence in a variety of data centers in North America including: Corporate data centers Web hosting data centers Co-location facilities The STABILOY Brand of products includes MC Cable, FeederPlex HS XHHW-2 cable, and single conductor WIDESTRIPE HS XHHW-2 cable, which are designed to distribute power throughout the building. Each of these cable solutions provides significant cost savings and reliable performance. STABILOY Brand MC Cable offers a durable interlocked aluminum armor to protect the electrical conductors from damage, while allowing flexibility in construction and design. The all-in-one assembly of MC Cable makes it a cost-effective solution for electrical retrofits in existing buildings. STABILOY Brand single conductor WIDESTRIPE HS XHHW-2, a phase-identified, low coefficient of friction cable can be used in EMT, PVC or other types of conduit. Our FeederPlex HS XHHW-2 cable is a factory-plexed assembly of XHHW-2 conductors that allows for fast and easy cable pulls while eliminating the need to pull multiple conductors from separate reels. So whether you are installing in conduit or not, STABILOY Brand aluminum alloy feeder cables offer you a safe, reliable and cost-effective solution for distribution feeder applications. Quality is never a question with STABILOY Brand cables. In fact, General Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Each STABILOY Brand single conductor and FeederPlex assembly is tested using the application of high voltage while immersed in water, ensuring that the insulation has zero defects. The superior performance of STABILOY Brand aluminum alloy cables has been validated by independent research. The Georgia Power Research Laboratory conducted a study comparing STABILOY Brand feeders to copper conductors. The results of the study show that connections installed on AA-8030 aluminum alloy performed as well as or better than connections installed on copper conductors of equivalent ampacity in the current cycle submersion test. STABILOY Brand aluminum alloy is readily available, infinitely recyclable and is manufactured in an environmentally responsible manner. STABILOY Brand feeders contain no heavy metals and are RoHS* compliant, and the cable jackets are free of lead and cadmium stabilizers. General Cable XHHW-2 insulation provides a longer life than THHN/THWN-2, thereby extending the total life of the installation and reducing waste. There s no question: green construction is the building trend of the decade. However, in today s tough economy, it is crucial to cut costs while considering the environmental impact of our building material choices. By including STABILOY Brand MC Cable in your project specifications, the savings you realize can be used to defray the cost of energy-saving devices and accelerate the payback of your data center. *Denotes compliance to RoHS, Directive 2002/95/EC. For more information on General Cable, call toll-free at 855-720-2792.

APPLICATION STABILOY Brand feeder cables are UL Listed and can be used for services and feeders. Service and feeder conductors to the main distribution center in a variety of buildings including: corporate data centers, web hosting data centers and co-location facilities. Feeder conductors for power distribution to the panel throughout a variety of building constructions including: wood stud, metal stud, concrete poured and cinder block. Feeder and branch circuits for a variety of specialized equipment and HVAC services. Temporary services for power throughout the construction phase. Our Metal Clad cable with PVC jacket can be used in exterior locations including wet locations and those exposed to sunlight. PROJECTS LIST Time Warner Data Center Syracuse, NY Microsoft Renovations Redmond, CA Amazon Boardman Data Center Pasco, WA Microtech Office Building Denton, TX Bank One Operations Data Center Fort Worth, TX Bank Data Center Guelph, ON SPECIFICATIONS Field Application Engineers are on staff to help you navigate the electrical specification process including takeoffs and voltage drop calculations. FAEs also serve as a resource for specification changes, value engineering proposals and technical questions. To gain the maximum value benefit on your project, specify STABILOY Brand 8000 Series aluminum alloy as an alternative in the Master Electrical Specification. A sample specification is included below for reference. 600-VOLT INSULATED CONDUCTORS A. All branch circuit conductors and feeder conductors 10 AWG and less shall be soft-drawn annealed copper with conductivity of not less than 98% IACS at 20 degrees C (68 degrees F). Conductors greater than 10 AWG copper may be converted to aluminum at the contractor s option. The contractor shall be responsible for increasing the conductor and conduit sizing, if necessary, when aluminum conductors are substituted for copper. The ampacity of the aluminum conductor shall be adequate for the load served and sized appropriately for the overcurrent device. The conduit fill shall not exceed NEC requirements. B. Conductors 10 AWG and smaller shall be solid and conductors 8 AWG and larger shall be stranded. Minimum wire size shall be 12 AWG unless otherwise noted on the drawings. C. All wire and cable shall be permanently marked to indicate size, voltage, type and temperature rating in accordance with NEC Article 310 and applicable product standards. 6 AWG and smaller grounded and equipment grounding conductors must be factory identified (typically white or green). D. Provide factory colored insulation for phase conductors 10 AWG and smaller. Larger insulated phase conductors may be factory identified with an approved field applied tape. E. Aluminum conductors shall be as follows: STABILOY Brand Type XHHW-2: For dry and wet locations, maximum operating temperature 90 C. The conductor shall be compact stranded AA-8000 series aluminum with black cross-linked polyethylene insulation. The cable shall meet the requirements of Federal Specification JC-30B. The conductor shall comply with ASTM Standards B800 and B801 or B836. ALUMINUM CONNECTORS AND TERMINATIONS A. All connectors and terminations shall be UL listed for use with aluminum conductors. All connectors and terminations shall comply with UL Standard 486A-B and be marked AL, ALCU, AL7CU or AL9CU for 90 C circuits. B. All connections and terminations shall be made in accordance with the connector or equipment manufacturer s recommendations. C. Tighten electrical connectors and equipment, including screws and bolts, in accordance with manufacturer s published torque tightening values. Where manufacturer s torquing requirements are not indicated, tighten connectors and equipment to comply with tightening torques specified in NEC Annex I.

STABILOY Brand aluminum alloy features a unique composition of metals that is specially engineered to give you the same performance as copper with less weight, lower cost and greater flexibility. Conductivity It s true. Aluminum conductors carry twice the current per pound as copper conductors. This is a significant performance advantage that utilities depend on for the national power grid. In feeder cable applications, the same performance advantage of aluminum can be realized by using STABILOY Brand aluminum alloy instead of copper. Insulation No question about it. STABILOY Brand aluminum alloy conductors feature superior insulation. In fact, the cross-linked polyethylene (XLPE) insulation on STABILOY Brand conductors performs better in cold impact, wet electrical and long-term aging tests. This makes it a better insulation for every application. Termination Why mix metals? STABILOY Brand aluminum alloy conductors terminate safely with industry standard dual-rated aluminum lugs.the similar metals connection eliminates thermal expansion mismatch, which translates into a safe and reliable termination. Quality It s a fact. General Cable tests every foot of every aluminum alloy feeder cable that it manufactures. Because STABILOY Brand aluminum alloy feeder cable is 100% tested for quality its reliability, durability and safety are all guaranteed! Performance High-quality STABILOY Brand aluminum alloy features a unique composition of metals that is specially engineered for superior performance in building feeder applications. Confidence You can rest assured. If aluminum is the utility companies preferred choice for carrying power all the way from the generator to the grid, it s the right choice for the last 100 feet of power delivery feeder cable. Ease-Of-Use STABILOY Brand aluminum alloy feeder cable is much easier to install. Maintenance for STABILOY Brand and copper is equal. This makes it more time-efficient and more cost-effective as well. Value At twice the ampacity per pound, not only is aluminum more cost-effective than copper, but the price of aluminum is much more stable than the price of copper. Sustainability Aluminum alloy is readily available and infinitely recyclable. In addition, STABILOY Brand aluminum alloy conductors are manufactured in an environmentally responsible manner.

Products MC Cable An all-in-one XHHW-2 conductor assembly with phase-identified conductors and a bare equipment grounding conductor. The assembly is a no conduit solution that provides labor and material savings of up to 50% over copper in conduit. STABILOY Brand MC Cable is available with and without a PVC jacket. FeederPlex HS XHHW-2 Factory-plexed assembly of aluminum alloy XHHW-2 conductors with specially designed XLPE insulation that allows for fast and easy pulling. Designed with phase identification for safer connections and delivered on one reel to the job site. STABILOY Brand FeederPlex HS significantly reduces installation time and effort during the pull, and minimizes site management. WIDESTRIPE HS XHHW-2 A single conductor aluminum alloy feeder cable with a specially designed XLPE insulation that allows for fast and easy pulling. Phase identification on the conductor consists of three wide color stripes embedded within the surface of the insulation. The insulation onstabiloy Brand WIDESTRIPE HS (High Speed) XHHW-2 conductors reduces pull force by 42% compared to the installation of regular XHHW-2 using pull lube. STABILOYBrand XHHW-2 A single conductor feeder with cross-linked polyethylene (XLPE) insulation that provides better performance than THHN insulation in hot and cold weather conditions, wet electrical tests, higher short circuit temperatures and long-term aging tests. CASE STUDIES NNSA National Security Campus Kansas City, MO Citadel Electric Group Inc. Oak Grove, MO Why STABILOY Brand? STABILOY Brand FeederPlex HS was specified and installed for this highly sensitive defense project to reduce installation time and on-site storage. Yahoo Data Center Buffalo, N.Y. Cupertino Design Engineers San Diego, CA Why STABILOY Brand? STABILOY Brand XHHW was installed in this large data center project to reduce installation time. www.stabiloy.com