ECET Distribution System Protection. Overcurrent Protection

Similar documents
Miniature circuit breaker Application guide

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Power systems Protection course

MAGNETIC MOTOR STARTERS

Design Standards NEMA

FUSE TECHNOLOGY Ambient temperature

EE 741 Over-voltage and Overcurrent. Spring 2014

FACT SHEET Standard: Electrical Safety

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Fuseology. Dual-Element, Time-Delay Fuse Operation

Selective Coordination Requirements

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

A. Submit manufacturer's literature and technical data before starting work.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Selecting Protective Devices

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Electrical Safety. Introduction

Recommended Procedures

ELECTRICAL. 60 Minutes

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Evaluating Selective Coordination Between Current-Limiting Fuses And Non Current-Limiting Circuit Breakers

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Service Entrance Methods

Low-Peak 600V Class RK1

Evaluating Selective Coordination Between

Overcurrent Protection According to the 2011 NEC

Electrical Safety. Recognizing & Controlling Hazards

Selective Coordination

Table of Contents. Review Answers...84 Final Exam...85 quickstep Online Courses...88

Fuseology. High Speed Fuses

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

The Evolution of Arc Fault Circuit Interruption

Overcurrent Protection (2014 NEC) (Homestudy)

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Electrical Safety and Overcurrent Protection

UL248 North American Low Voltage Fuses

3.2. Current Limiting Fuses. Contents

Engineering Dependable Protection

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

Electrical Equipment and Terminology

www. ElectricalPartManuals. com Engineering Dependable Protection

Equipment Protection. Transformers 600V or Less

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

PROTECTION OF THE BRANCH CIRCUIT

Selective Coordination Enforcement:

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Motor Protection. Presented By. Scott Peele PE

INSTALL CIRCUIT PROTECTIVE DEVICES

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

TRANSMISSION SYSTEMS

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Fused Coordination Panelboard

Compact Circuit Protector (CCP) Application Note

Design considerations for generator set mounted paralleling breakers

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

White Paper. Ground Fault Application Guide. WL Low Voltage Power Circuit Breakers

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

RESIDUAL CURRENT CIRCUIT BREAKER

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Reducing. with Current. arc flash note 2. points of interest. Why Use Current Limiting Fuses. By mike lang, Principal field engineer

Fuses still the best form of overload protection

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

Motor Protection. Voltage Unbalance & Single-Phasing

Introduction. Upon completion of Basics of Circuit Breakers you will be able to: Explain the need for circuit protection

Selection Guide. Control Circuit and Load Protection

Bulletin 1489 Circuit Breakers. Selection Guide

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

What is included in a circuit diagram?

Self-protected Combination Starters System PKZ 2-SP

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

Busway Construction. Bus Bars

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

1489-M Circuit Breakers

Electrical Protection

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Advanced Design - Legendary Performance - Superior Circuit Protection - Count on it. An Introduction to Overcurrent Protection

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Grounding Of Standby & Emergency Power Systems

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

Quick Start Guide TS 910 & TS 920

A Special Note To Our Customers

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

TERMS AND DEFINITIONS

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Equipment Protection. Transformers 600V or Less

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

General Purpose US Fuses

18.5. Electrical Circuits and Safety

General information about motor protection

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Electrical Energy and Power Ratings

Companion II 8.3kV, 17.2kV and 23kV 12K - 40K Backup Fuses

Current Ratings. Standards & codes note 1. Introduction. interest. By Steve Hansen Sr. Field Engineer

Specification made simple for selective coordination in a compact size

Transcription:

ECET 4520 Industrial Distribution Systems, Illumination, and the NEC Distribution System Protection Overcurrent Protection One of the most important aspects of distribution system design is system protection. Overcurrent protection for conductors and equipment is provided to de-energize (open) a circuit if the circuit current reaches a value that will cause the operational temperature in the circuit conductors or in the terminating equipment to exceed the temperature rating. 1

Overcurrent Overcurrent any current in excess of the rated current of equipment or the ampacity of a conductor. It may result from an overload, short circuit, or ground fault. Although any current above rated current may be considered an overcurrent, overcurrents are typically separated into two distinct classes: Fault (Short Circuit) Currents Overload Currents System Faults Short Circuits Short-Circuit a short-circuit occurs when one or more of a circuit s energized conductors are either directly connected to each other or to a neutral (grounded) conductor. A short-circuit can result in exceptionally large currents that, if not mitigated quickly, can damage or destroy system components, cause a fire, and/or lead to injury or death. 2

System Faults Short Circuits The short-circuit current available at any point in a distribution system is key factor that must be considered when selecting the system s protective devices. As per the NEC: Equipment intended to interrupt current at fault levels shall have an interrupting rating sufficient for the current that is available at the line terminals of the equipment. (Article 110.9) The overcurrent protective devices shall be selected and coordinated to permit the circuit protective devices used to clear a fault to do so without extensive damage to the electrical equipment of the circuit. (Article 110.10) System Faults Ground Faults Ground Fault a ground fault occurs in a distribution system when an electrically conductive path is created from a circuit conductor back to the electrical supply source through the system s normally non-current-carrying conductors or equipment, external conductive materials or pathways, or the earth itself. 3

Ground-Fault Circuit Interrupter Although ground faults can also result in exceptionally large currents, a high-impedance ground fault can produce relatively small currents that may still present a risk of fire or injury due to electrocution but may not be detectable by a system s primary protective devices. A Ground-Fault Circuit Interrupter (GFCI) is a device intended for the protection of personnel that functions to de-energize a circuit within an established period of time when a current to ground exceeds the values of 4-6mA. Note GFCIs are not covered in this presentation. Overcurrent vs. Overload Overcurrent any current in excess of the rated or maximum allowable continuous current of a circuit. Overload operation of equipment in excess of normal, fullload rating, or of a conductor in excess of rated ampacity that, when it persists for a sufficient length of time, would cause damage or dangerous overheating. Note the term overcurrent is sometimes used to refer only to currents whose magnitudes are in excess of those associated with an overload, up to and including those that result from an ideal short-circuit fault. 4

Overloads Overload an overload occurs when more than the rated (maximum allowable continuous) current flows along the normally conductive path of a circuit. An overload is not the result of a system fault since a fault, by nature, bypasses the normal conductive path in a circuit. Instead, an overload is typically the result of either improper circuit loading or improper/abnormal operation of a load. Overload Examples Examples of Overloads due to Improper Circuit Loading: Too many loads are simultaneously plugged into the receptacles of a 20A, general-purpose branch circuit resulting in a current draw that is greater-than 20A. Over time, as the lightbulbs in a dimly-lit parking deck burn-out, the fixtures are retrofitted for brighter bulbs. The higher wattage rating of the new bulbs eventually cause the current draw to exceed the rating of the circuit. The 240/120V 1Φ service of a small commercial facility is upgraded to a 208Y/120V 3Φ service without replacing the facility s 230V 1Φ AC compressor motors. When supplied at 200V instead of 230V, the motors draw larger currents, in-turn overloading their circuits. 5

Overload Examples Example of an Overload due to Improper Load Operation: Thirty people squeeze into an elevator that has a posted maximum occupancy of twenty. The excessive weight causes the elevator s motor to run slower, in-turn drawing a larger-than-rated current that could be potentially damaging if the improper operation is allowed to continue for extended periods of time. Example of an Overload due to Abnormal Load Operation: Due to a mechanical failure, the shaft of a 3 Induction Motor is not able to rotate. If energized and supplied with rated voltage, the motor may draw from 4-10x it s rated current, resulting in quick, excessive heating in both the motor itself and in the conductors of the circuit supplying the motor. Ampacity vs. Current Rating Conductor Ampacity the maximum current, in amperes, that a conductor can carry continuously under the conditions of use without exceeding its temperature rating. In comparison to ampacity, the Current Rating of a circuit is the maximum current that a circuit can supply to its load(s), as determined by the rating or setting of the overcurrent device that is protecting the circuit. 6

Ampacity vs. Current Rating Note that: The ampacity of a circuit s conductors provides a maximum limit to the current rating of a circuit. Although conductor ampacity provides an upper limit for a circuit s current rating, it is the rating of the circuit s overcurrent protective device that defines the actual current rating of the circuit. Despite its rating, a circuit may not be able to supply rated current continuously to its loads. Overcurrent Protection Devices The proper design of a distribution system may include the use many different devices that provide protection during the occurrence of a system fault or overload. These devices primarily include: Fuses Circuit Breakers Ground-Fault Circuit Interrupters 7

Fuses A fuse is a protective device that can be placed in series with a circuit conductor in order to limit the conductor current to a safe level. A fuse can only interrupt current flow one time, after which the fuse (or the fusible link) must be replaced. Fuse Operation A fuse consists of a fusible link (metal strip or wire) that is encapsulated in a non-conductive housing. The link is designed such that it will melt when the current flowing through the fuse exceeds a prescribed value. During normal operation, the link simply acts as a part of the conductive circuit. But, when an overcurrent occurs, the link melts and open-circuits the conductive path in order to prevent any further damage to the distribution system. 8

Fuse Ratings Fuses are characterized by several different criteria, including: the current rating of the fuse the interrupting rating of the fuse the voltage rating of the fuse the time-delay or rate at which the fuse will operate when exposed to an overcurrent Current Rating of a Fuse The Current Rating of a fuse provides the maximum current magnitude that may continuously flow through the fuse without the fuse blowing. situation. For example: A 30A fuse will theoretically blow if subjected to a current over 30 amps. 60A current rating Note that the above statement may or may not hold true depending on the specific type of fuse, the actual magnitude of the current (above 30A), and the duration of the current flow exceeding 30A. 9

Interrupting Rating of a Fuse A fuse s Interrupting Rating (IR) defines the maximum current magnitude that the fuse can safely interrupt. Fuses must be chosen such that their IR not less than the available short-circuit current at their location. Note that fuses may have different IR values for AC and DC systems. 200kA RMS AC IR 20kA DC IR is Voltage Rating of a Fuse A fuse s Voltage Rating defines the maximum operational voltage of the system in which the fuse can be applied. For example: A fuse with a 600V AC rating is suitable for use in AC systems having an operational voltage that is less than 600 volts. Note that fuses may have different voltage ratings for AC and DC systems. 250V AC 125V DC 10

Fuse Type Along with their current and voltage ratings, fuses are classified by the rate at which they operate: Fast Acting Time Delay Current Limiting Dual Element For example: A fuse protecting a motor circuit must operate with a time delay due to the motor s large starting current while still offering fast protection in the case of a short circuit. Fuse Classes Furthermore, fuses are separated into many standardized classes based upon: the type of circuit/load for which they are intended (AC, DC, lighting, motor, etc.) their ratings their performance (current limiting ability, etc.) their physical construction 11

Selected Fuse Classifications: Fuse Classes UL Class Type Interrupting Rating (ka) H Fast-Acting 10 AC Voltage Ratings (V) 250 600 Available Ampere Ratings (A) 1 600 L Time-Delay 200, 300 600 601 6000 CC Time-Delay 200 600 1/10 30 Suitable Uses / Protection General-purpose branch & lighting circuits (not inductive/motor loads) Feeders and service entrance equipment Motors, control transformers, etc. Selective Coordination The proper design an electric distribution system requires the selective coordination of the system s overcurrent protection devices. Selective Coordination is The act of isolating a faulted circuit from the remainder of the electrical system, thereby eliminating unnecessary power outages. The faulted circuit is isolated from the selective operation of only that overcurrent protective device closest to the overcurrent condition. - Bulletin EDP-2, Selective Coordination of Overcurrent Protective Devices Cooper Bussmann 12

Selective Coordination The proper design an electric distribution system requires the selective coordination of the system s overcurrent protection devices. Selective coordination requires knowledge of the exact operational characteristics of the fuse. These characteristics are provided by the fuse manufacturer by means of a time-current curve. Fuse Time-Current Curves A Time-Current Curve, also referred to as an I 2 t curve, defines the rate at which a fuse will operate as a function of the current magnitude flowing through the fuse. 13

Fuse Time-Current Curves Operation in the area to the left of any curve defines normal operation (both continuous and transient current flow), while operation in the area to the right of any curve result in current interruption. (i.e. a blown fuse) current interruption Note the regions for normal operation and for current interruption are highlighted for the 15A fuse. normal operation Fuse Time-Current Curves For example: The 15A fuse whose time-curve is shown to the right will: blow in 120 seconds for a 30A steady-state circuit current blow in 11 seconds for a 75A steady-state circuit current blow in 0.11 seconds for a 150A steady-state circuit current 14

Fuse Time-Current Curves To prevent conductor damage, fuses should be chosen such that their time-curve allows them to interrupt the circuit current before unsafe heating occurs in the conductors. 100sec 10sec t Normal Operation Damage Region Conductor Heating Curve Fuse / C.B. Time Curve 1sec IZ I Fuse Time-Current Curves In terms of selective coordination, fuses are selected by overlaying their time-current curves to guarantee that the fuse closest to a fault will operate faster than fuses that are further up-stream (closer to the service entrance). 15

Circuit Breakers Similar to a fuse, a circuit breaker is a device that is also placed a circuit to protect the circuit against overcurrents. But, unlike a fuse, a circuit breaker can be reset after operation, thus allowing it to operate many times without replacement. Circuit Breakers Circuit breakers are also given ratings based upon: the normal current that they are expected to carry their current interrupting ability their operational system voltage 16

Circuit Breakers Unlike fuses that can protect only a single circuit conductor, circuit breakers come in a variety of configurations (singlepole, multi-pole, etc.), allowing the to simultaneously protect one or more circuit conductors. Additionally, a circuit breaker s operation can be based upon several different fundamental principles, allowing for very complex operational characteristics. Some circuit breakers even allow for adjustment of the operational settings. Circuit Breaker Operation Magnetic circuit breakers rely on the magnetic pull force created by a solenoid to release a latch, allowing a spring to open a set of electric contacts, thereby interrupting the current flowing in a circuit. Thermal circuit breakers rely on the heating and bending of a bimetal strip to due to release a latch and allow a spring to open a set of electric contacts. Note that circuit breakers can be constructed such that they incorporate both techniques; using the magnetic mechanism to provide a quick response to large (short-circuit) currents, and using the thermal mechanism to provide a time-delayed response to lesser currents (overloads). 17

Circuit Breakers The construction of circuit breakers is also greatly affected by their operational voltage level and their current interrupting capability. The various issues involved when designing circuit breakers that are capable of operating at high voltages and/or interrupting large currents are beyond the scope of this presentation. Circuit Breaker Configuration Circuit breakers are produced in a variety of different configurations: Single-pole circuit breakers operate based upon the current flowing in a single conductor & protect only that conductor Multi-pole circuit breakers protect multiple conductors simultaneously, operating if any one of the protected conductor currents exceed their rated values 18

Circuit Breaker Time Curves The detailed operation of a circuit breaker is characterized by an inverse time-current curve. Circuit breaker time-curves are used in the same manner as those provided for fuses, allowing for circuit breakers to be incorporated into the selective coordination scheme for the distribution system. Circuit Breaker Time Curves Furthermore, some circuit breakers are designed such that a limited adjustment may be made to their operational time-current curve, increasing the flexibility of their use within a distribution system. 19