INTRODUCTION. initiate or display a low order of detonation. 1 Note that while there are several basic constructions for electric detonators used in

Similar documents
Experimental Investigation of Hot Surface Ignition of Hydrocarbon-Air Mixtures

Transmission Error in Screw Compressor Rotors

Product Loss During Retail Motor Fuel Dispenser Inspection

Multipulse Detonation Initiation by Spark Plugs and Flame Jets

Lab Session #1 Initiation Systems and Types of Explosives

Onboard Plasmatron Generation of Hydrogen Rich Gas for Diesel Engine Exhaust Aftertreatment and Other Applications.

A Guide to the Carriage. by Road of Detonators. with Blasting Explosive Substances

A new approach to the results of internal inspection

Reference Number: SMS-4211-L1, Rev 0 Date: May 2, 2018

Burn Characteristics of Visco Fuse

Marc ZELLAT, Driss ABOURI, Thierry CONTE and Riyad HECHAICHI CD-adapco

Comparing Flow and Pressure Drop in Mufflers

Inventor Fred W. Watson. Jr. NOTICE

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

A NEW INITIATION SYSTEM THAT REMOVES THE OUTSIDE OR SURFACE DETONATORS FROM THE UNDERGROUND FACE. M Davis and J Fenwick Master Blaster

Circuits for Protecting and Triggering SCRs in High Power Converters

Development of a Rubber Disc Piston Seal for the Mahadaga Handpump Peter Govey, Christopher Claassen, Joseph Longenecker Messiah College 2006

A view on the functioning mechanism of EBW detonators-part 3: explosive initiation characterisation

Special edition paper

INFLUENCE OF MAGNET POLE ARC VARIATION ON THE COGGING TORQUE OF RADIAL FLUX PERMANENT MAGNET BRUSHLESS DC (PMBLDC) MOTOR

Proposal to establish a laboratory for combustion studies

Sumitomo Rubber Industries, Ltd., Grant of Petition for Decision. AGENCY: National Highway Traffic Safety Administration (NHTSA),

E*Star Seismic Detonators. Electronic Programmable Detonators.

M:2:I Milestone 2 Final Installation and Ground Test

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves

Chemical decontamination in nuclear systems radiation protection issues during planning and realization

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014

Control of Static Electricity during the Fuel Tanker Delivery Process

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Instructional Objectives. Science of blasting. Blasting Objectives. Black Powder. Explosive materials. GE 5471 ROCK ENGINEERING CH 13 Blasting

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

Dr. Jim Henry, P.E. Professor of Engineering University of Tennessee at Chattanooga 615 McCallie Avenue Chattanooga, TN Dr.

Emergency Response Guide

Fischer-Tropsch Refining

THE TORQUE GENERATOR OF WILLIAM F. SKINNER

Article: The Formation & Testing of Sludge in Bunker Fuels By Dr Sunil Kumar Laboratory Manager VPS Fujairah 15th January 2018

Powered Industrial Truck Safety Program

Overcoming Motor Driver Heat-Transfer Challenges in Robotic Applications

Free Piston Engine Based Off-Road Vehicles

A REACTIVE MINE CLEARING DEVICE: REMIC. M. Majerus, R. Colbert, E. Molengraft III, R. Brown,1 and D. Patel2

Sport Shieldz Skull Cap Evaluation EBB 4/22/2016

ZDM Positive Displacement Flow Meter User Instructions

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

MULTI-POLE MOUNT LARGE GROUND MOUNT. Assembly Instructions. Assembly Instructions. step-by-step assembly and installation

Shock tube based dynamic calibration of pressure sensors

Large Electric Motor Reliability: What Did the Studies Really Say? Howard W Penrose, Ph.D., CMRP President, MotorDoc LLC

WLTP. The Impact on Tax and Car Design

HONEYCOMB & PLEATED SHADES

INSTALLATION INSTRUCTIONS TOOLS YOU WILL NEED TABLE OF CONTENTS

Regional Products Training in Singapore

Friction. Coefficients of friction for rubber on roads are listed in the table. asphalt road) Dry road Wet road 0.53

Sumitomo Rubber Industries, Ltd., Receipt of Petition for. AGENCY: National Highway Traffic Safety Administration (NHTSA),

2013 PLS Alumni/ae Survey: Overall Evaluation of the Program

MIXPAC TM Technical Services Your partner for successful solutions. Sulzer Chemtech

RNRG WHITE PAPER Early Detection of High Speed Bearing Failures

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

3.2. Current Limiting Fuses. Contents

TECHNICAL DATA. Trimpac 249a. September 16, 2013

2.61 Internal Combustion Engine Final Examination. Open book. Note that Problems 1 &2 carry 20 points each; Problems 3 &4 carry 10 points each.

Flow Visualization Tunnel. Owner s Manual. May 2009

INCREASING THE ELECTRIC MOTORS EFFICIENCY IN INDUSTRIAL APPLICATIONS

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

SET-UP TWO STROKE - presentation. SET-UP TWO STROKE - data entry

Certification Memorandum. Additive Manufacturing

APPLICATION OF AE TECHNIQUE AND THERMOGRAPHY FOR ASSESSMENT OF SLUDGE VOLUME INSIDE CRUDE OIL STORAGE TANKS

CGD8800X CGD8800X220 Combustible Gas Detector

HERCULES-2 Project. Deliverable: D8.8

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD

Normal vs Abnormal Combustion in SI engine. SI Combustion. Turbulent Combustion

3/8" NPT PISTON SPRING INLET EXHAUST VALVE SPRING LOWER PISTON ASSEMBLY

Determination of the Rate of Ignition of Nitrocellulose by Resistance Wire for the Igniter of KV 150 M2

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

Electrostatic Ignition Hazards Associated with the Pneumatic Transfer of Flammable Powders through Insulating or Dissipative Tubes and Hoses

Analysis of Pre-ignition Initiation Mechanisms using a Multi-Cycle CFD-Simulation

KISSsys Application 008: Gearbox Concept Analysis

Design of A New Non-Contact Screw Seal and Determination of Performance Characteristics

NEGATIVE DIFFERENTIAL PRESSURE BY IGNITION OF GRANULAR SOLID PROPELLANT

Chapter 4 ANALYTICAL WORK: COMBUSTION MODELING

Customer Survey. Motives and Acceptance of Biodiesel among German Consumers

Emergency Response Guide

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

Toward New French IM General Purpose bombs

IMPROVED HIGH PERFORMANCE TRAYS

Fractional Distillation Lab Simulating The Refining of Petroleum 12/12 Integrated Science 3 Redwood High School Name : Per:

Fig There is a current in each wire in a downward direction (into the page).

THERMAL MANAGEMENT OF AIRCRAFT BRAKING SYSTEM

Your interest is appreciated and hope the next 37 pages offers great profit potential for your new business. Copyright 2017 Frank Seghezzi

Rotating Detonation Wave Stability. Piotr Wolański Warsaw University of Technology

Laboratory Exercise 12 THERMAL EFFICIENCY

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

ITS-50R TRANSFER SWITCH OWNER S MANUAL

CHAPTER 8 EFFECTS OF COMBUSTION CHAMBER GEOMETRIES

RESULTS OF A MIXING TRIAL USING THE CALEVA MULTI LAB MIXER/GRANULATOR WITH SOME DIFFICULT MATERIALS

PRIMADET non-electric delay detonators MS Primadet - millisecond series

Security Council. United Nations S/2010/281

Electromagnetic Fully Flexible Valve Actuator

Reliability of Thermal Batteries Melissa Keener

2013 Latin America Perforating Symposium. SLAP-23 Perforating Options Available Today in Horizontal Shale Oil and Gas Wells. Kerry Daly, Weatherford

Transcription:

INITIATION SYSTEMS FOR OIL AND GAS PERFORATING GUNS An investigation of the effects of industry- used cleaning fluids on the A- 140F perforator initiation system. Prepared by Erika Nieczkoski and Dr. Vilem Petr Colorado School of Mines Department of Mining Engineering Advanced Explosives Processing Research Group INTRODUCTION Fluid desensitized detonators were developed specifically for the petroleum industry, designed as an additional precaution against the occasional leakage of liquid (oil, water, and perhaps a mixture of oil and water) into the perforator carrier [1]. The alternative design 1 ensures that should any liquid enter the detonator, specifically the distance between the fuse head and base charge, desensitization will occur, and thus the perforating shape charges will not detonate. However, partial order detonation 2 has been observed regardless of the absence of a leakage; this an obvious safety concern for wireline operators. The industry speculates that the reason for this occurrence is the presence of residual perforator cleaning fluids within the assembly. Typically, perforating equipment is cleaned with water, and petroleum-based distillates: mineral spirits and diesel fuel. It is an easier, more cost effective method to clean the equipment and to use it again, instead of returning it directly to the manufacturer. Essentially, the assumption is that some residual cleaning fluid is left in the system, and is then sealed into the assembly. When the perforator is lowered into the production well, temperatures become significantly high reaching 300 degrees Fahrenheit and the residual liquids become vaporized within the system. Although the fluid desensitized detonators are designed not to detonate in the presence of a liquid obstruction, the chemical effects of small amounts of liquids and vaporized petroleum-based cleaning fluids have not been studied. The industry, however, has noted a significantly higher order of partial detonation of the detonators in field operations than in laboratory conditions. Undoubtedly, this is causing concern that operating procedure is, ultimately, the primary source of initiation system error. Thus, this investigation was conducted by undergraduate researchers from the Advanced Explosives Processing Research Group (AXPRO) at the Colorado School of Mines to determine the effects of cleaning fluids on the typical perforator initiation system, with experimentation designed in such a way that 1 Note that while there are several basic constructions for electric detonators used in wireline operations, including non- resistorized, resistorized, fluid disabled, and fluid sensitive detonators, this investigation focuses exclusively on the alternatively designed fluid desensitized detonators. 2 Partial order detonation occurs when some components of the initiation system do not initiate or display a low order of detonation.

all conditions for partial detonation were understood, and subsequently either eliminated or acknowledged. METHODS AND MATERIALS Experimentation was conducted with the Austin Powder A-140F Block Type OilStar Detonator (A-140F Detonator), and Fireline 17/80 RDX Oil Field Detonating Cord. The A-140F Detonator is a fluid-desensitized detonator that is typically used by the petroleum industry, and was specifically noted by a wireline company as experiencing a higher order of field operation failures, which were speculated to be a result of the effects of residual cleaning fluids within the sealed gun assembly. A general description of the A-140F Detonator involves a metal detonator shell, with a base charge (compressed cyclotrimethylenetrinitramine (RDX) capped with a small amount of lead azide) being positioned at one end of the shell, and protected by a mesh. Adjacent to this, but a sufficient distance away, is a fuse head (a low explosive), a donor explosive, embedded with a bridge wire, which connects the legs wires, thus forming a means of electrical ignition [2]. If a firing current is applied to the leg wires, then the bridge wire becomes incandescent, and the fuse head is initiated [1]. This initiation then has enough force to initiate the base charge and, subsequently, cause detonation of the detonating cord. If liquid fills the space between the fuse head and base charge through the fluid desensitizing holes, then the initiation of the fuse head charge should not have enough force to initiate the base charge, and therefore, detonation should not propagate to the detonating cord. Figure 1. Diagram of initiation system components with detailed illustration of the A-140F Block Type Detonator interior design.

Initiation System Failure Study AXPRO began experimentation with an evaluation of the various possible conditions for partial detonation of the initiation system to ensure a standard against which the cleaning fluids testing could be compared to. Incorrect operating procedure with each component of the initiation system was tested as a control to standardize established user error as conditions for partial detonation. Thus, testing investigated user initiation system assembly that was either described by the manufacturer as not following procedure, or was not a generally recommended practice [2]. Specifically, I) tape covering the fluid desensitizing holes of the detonator was not removed before use, II) the detonating cord position was varied, and not standardly positioned through the cord hole in the block, and III) the detonating cord was physically damaged so that the amount of secondary explosive within it was reduced. AXPRO investigated the detonator s compatibility with cleaning fluids by testing varied amounts of misted mineral spirits and diesel fuel on the fuse head and the base charge, respectively. To examine the detonator s sensitivity to fluids, the initiation system was partially and completely submerged in fresh water. AXPRO also completely submerged the detonator in crude oil, as well as produced water, to observe the detonator s sensitivity to wellbore fluids. Experimentation of the initiation system at accurate wellbore temperature and pressure was not conducted at the AXPRO Research Laboratory at the Colorado School of Mines because of safety and cost concerns, and because this investigation s primary objective was to provide proof of concept. AXPRO conducted further examination of the detonator s sensitivity to fluids to verify experimental results. The preliminary sensitivity testing indicated that the detonators were not becoming desensitized when fully submerged in fresh water, and thus further examination was needed. As noted previously, testing involved both partially and completely submerging the initiation system in fresh water. For these studies, the detonator was oriented with the leg wires pointed downwards, and curled upwards through the block; the industry indicated that this orientation is used in standard wireline procedural practices. Initiation system performance was evaluated using a high-speed Phantom 7.13 Light System Camera, with a frame rate of 59,027 frames per second. Detonator Fluid-Desensitizing Function Study Inasmuch as AXPRO continued to observe full order detonation of the A-140F Detonators, further experimentation was conducted, with recommendation from the

manufacturer, to evaluate the influence of hydrostatic pressure on the detonator. The Austin Powder Company first performed the hydrostatic pressure testing, orienting the detonator in its standard position, with the leg wires pointed upwards. Fundamentally, the company concluded that at an immersion depth of 50 cm, it was clearly observed that the detonator s fluid-desensitizing (FD) function was operating correctly [4]. Thus, AXPRO performed similar experimentation, placing the detonator at immersion depths of 50 cm and 85 cm, but keeping the detonator oriented in the industry standard, with the leg wires pointed downwards. However, as there are significant elevation differences between Golden, Colorado, United States, and Vsetín, Czech Republic, the locations where AXPRO and Austin Powder Company conducted testing, respectively, the immersion depth of detonator was adjusted by AXPRO to achieve approximately the same hydrostatic pressure where the Austin Powder Company reported having proper FD function. Accordingly, the detonator was submerged at an immersion depth of 200 cm, and placed in various orientations: I) the detonator was oriented according to industry standard II) the detonator was oriented according to manufacturer standard, III) the entire initiation system (A-140F detonator with block, and detonating cord) was submerged, with the detonator oriented according to industry standard, IV) the detonator was oriented horizontally, and tilted slightly upwards, with the fluid desensitizing holes oriented horizontally, V) the detonator was oriented horizontally, with the fluid desensitizing holes oriented vertically, and VI) the detonator was oriented horizontally, and tilted slightly downwards, with the fluid desensitizing holes oriented horizontally. Note that initiation system performance was evaluated, using a high-speed Phantom 7.13 Light System Camera, for experimentation with the detonator at immersion depths of 50 cm and 85 cm. However, because a long steel pipe was used for subsequent testing at immersion depths of 200 cm, use of high-speed imaging for evaluation was not possible, therefore initiation system performance was assessed post-blast. RESULTS AND IMPLICATIONS Initiation System Failure Study Although AXPRO s evaluation of the initiation system by failure to follow manufacturer recommendations was intended to ensure a controlled experiment, and standardize incorrect operating procedures as conditions for partial detonation, the experimental data indicates that the importance of specific procedure needs to be reaccessed by the manufacturer, as well as the industry. High-speed imaging results demonstrated that the initiation system had full order detonation despite AXPRO I) failing to remove the tape from the detonators before use, II) varying the detonating cord position from standard-position, and III) physically damaging the detonating cord so that the amount of explosive within it was reduced. Thus, while it is always important to follow the manufacturer s directions, and handle explosives and explosive devices with

great caution, industry employees must consider all conditions when ensuring proper function of their explosive devices. Partial order detonation of the detonator was observed when the petroleum-based cleaning fluids, mineral spirits and diesel fuel, were placed directly on the detonator s base charge chemically, RDX displays decreased thermal stability when in the presence of petroleum-based cleaning products [3]. However, the fuse head was not desensitized when in the presence of the distillates, suggesting that the low explosive is not soluble to petroleum-based solutions. Thus, industry-operating procedure is indeed a cause of partial order detonation of the perforator initiation system. Although using petroleumbased distillates to clean perforating equipment is not a manufacturer recommended practice, it is not an obvious concern. Therefore, procedural changes are required to ensure effective production and safety within the industry. Wireline companies, specifically, should not use mineral spirits or diesel fuel to clean perforating equipment it would be more suitable to use a fluid that both the fuse head and the base charge have shown no reaction to, perhaps fresh water. Otherwise, it is advisable that companies return the equipment to the manufacturer to either be professionally cleaned or replaced. Notwithstanding AXPRO s observation of the effects of the petroleum-based cleaning fluids, full order detonation was observed when the detonator was submerged, as well as shaken, in the wellbore fluids, crude oil and produced water. Thus, it is yet unclear what components of the cleaning fluids caused the base charge to become desensitized AXPRO is currently conducting a chemical analysis on the distillates. Detonator Fluid-Desensitizing Function Study Fully submerging the A-140F Detonator in fresh water when industry-oriented, demonstrated an inconsistency in the FD function, as AXPRO s high-speed imaging evaluated the detonations consistently as full order. Thus, as was previously indicated, immersion depth tests were recommended by the Austin Powder Company, with the assumption that the detonator FD function required a specific hydrostatic pressure to begin to operate properly at the Colorado School of Mines in Golden, Colorado, United States, this approximate pressure was calculated to be at an immersion depth of 200 cm. Thus AXPRO conducted several experiments at this depth, with varying orientations. Consistent, full order detonation was observed when the detonator was oriented according to industry-standard; when the entire initiation system was submerged, with the detonator oriented in industry-standard, this detonation was powerful enough to propagate to the detonating cord. However, when the detonator was oriented according to manufacturer-standard, AXPRO observed partial order detonation, as only the fuse head detonated. Partial order detonation also occurred when the A-140F Detonator was oriented horizontally, and tilted downwards with the fluid desensitizing holes horizontal, and when the detonator was oriented horizontally, with the fluid desensitizing holes vertical. When the detonator was oriented horizontally, and tilted upwards with the fluid desensitizing holes horizontal, AXPRO observed full order detonation. These discrepancies in detonation order, can indeed, be explained by the varying orientations, as specific orientations create distinct air bubble locations. When the detonator is oriented

according to industry-standards, or oriented horizontally, and tilted upwards with fluid desensitizing holes horizontal, an air bubble is trapped directly beneath the base charge and mesh. When a firing current is applied to the leg wires, the bridge wire becomes incandescent, and the fuse head is initiated. This detonation creates a shockwave travels through the high density water as a compression wave, eventually reaching the low density air, which causes spalling, in these circumstances, high velocity water droplets that impact the mesh and subsequently have enough force to initiate the very sensitive lead azide primary explosive, and therefore the RDX [4]. When the detonator is oriented according to manufacturer-standards, or oriented in the other positions that displayed partial order detonations, the air bubble is trapped below the fuse head. Thus, when the fuse head is initiated, there is indeed a detonation shockwave that moves from the lowdensity air to the high-density water, but no direct physical force to initiate the base charge. Thus, while the A-140F Detonators are certainly quite durable, and their block design functions exceptionally well in allowing detonation to propagate to the detonating cord, they act in a distinctive way depending upon their orientation, at least on a surface level, and certainly the industry should be aware of these characteristics. LIMITATIONS AND RECOMMENDATIOBS Because testing the failure to follow the manufacturer's recommendations proved relatively inconclusive, AXPRO would like to conduct more experimentation involving explicitly not removing the manufacturer's tape on the detonator, and placing the initiation system at an immersion depth of 200 cm, with the detonator oriented according to manufacturer-standards. It is expected that the tape, which covers the detonator's fluiddesensitizing holes, would provide enough of a seal to ensure no leakage of water into the detonator, thus allowing for full order detonation of the initiation system. Although experimentation was not conducted at accurate wellbore temperature and pressure, because of safety, as well as cost concerns, it would certainly be significant for AXPRO to understand the effects of vaporized fluids, in combination with significantly high pressures, on the A-140F Detonator. Thus it is recommended that further testing be conducted with the petroleum-based cleaning fluids, mineral spirits and diesel fuel, and the initiation system in accurate simulations of the wellbore environment. The detonator's FD function, with varying orientation, should also be examined in this environment. Note that while accurate wellbore conditions include a lengthy immersion time (in cleaning fluids, wellbore fluids, or fresh water), AXPRO expects little variation in the results of the FD function studies with this variable, as the FD function is designed to operate immediately in the presence of a liquid obstruction. As a university-affiliated group, AXPRO conducts experimentation with an objective perspective. The petroleum industry, and specifically wireline companies, must be aware of the operation characteristics of their detonators. Fundamentally, AXPRO believes that it would be exceptionally beneficial to assist the industry, and specifically wireline companies, to achieve a greater understanding of their perforator initiation systems; AXPRO's Research Laboratory certainly has the capability to allow for

thorough examination of the advantages and limitations of the various production well detonators. ACKNOWLEDGEMENTS Our sincerest appreciation is conveyed for the excellent work and effort that our Explosives Engineering II students from the Colorado School of Mines, Keegan Pratt, Matt Balderston, Chris Drury, and JohnRex Hewitt dedicated to this project. We would further like to acknowledge Ray Johnson, our AXPRO researcher at the Colorado School of Mines. Many thanks to him for putting his valuable time into this project, and for offering his invaluable knowledge. We would also like to offer our deepest thanks to Gary Fisher for providing the detonators and other materials to conduct this research work, for his time, his infectious enthusiasm, and his endless patience. Many thanks, as well, to the AXPRO/Colorado School of Mines Mining Department for offering their technical support, and for allowing us to use both their high speed camera and blasting chamber REFERENCES [1] M. E. Swanson, Initiation device desensitized by fluids, U.S. Patent 2 891 477, June 23, 1959. [2] Austin Powder Company, A-140 F & Block: Fluid Disabled Resistorized Instantaneous RDX Detonator Assembly, Austin Powder Company. [Online]. Available: http://www.austinpowder.com/blastersguide/docs/pib/oilstara140fbk.pdf [Accessed: April 18, 2015]. [3] B. W. Harris, Oil/High Explosive Compatibility Study: Selection of Safing Fluids for Damaged Explosives Assemblies. Propellants, Explosives, Pyrotechnics, vol. 9, pp 7-11, 1984. [4] Personal communication with researchers at the Austin Powder Company in Vsetin, Czech Republic.