High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Similar documents
High Voltage Copper, Smooth Aluminum Shield/Sheath

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG

UNDERGROUND TRANSMISSION SOLUTIONS

MC or MV-105 Copper, TR-XLPE Insulated

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Caledonian Medium Voltage Cables

C-L-X Aluminum Sheath Type IEC

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

Medium Voltage Cable. marmonutility.com

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Okoguard -Okoseal Type IEC

TC-RHH/RHW-2 USE-2 Copper

Medium Voltage Power Cables

MEDIUM VOLTAGE

Medium Voltage Cables for PermaLife Nuclear Utility Applications

High Voltage and Extra High Voltage Cables

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

North America HIGH&EXTRA-HIGH VOLTAGE UNDERGROUND SOLUTIONS

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

XLPE Cable Systems. User s guide. rev. 2

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

SPECIFICATION FOR EXTRUDED DIELECTRIC, SHIELDED POWER CABLES RATED 5 THROUGH 46 kv

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Power & Control Cable IEC

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

200 A 25 kv and 28 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

Company Profile. Caledonian Medium Voltage Cables

XLPE CABLES AND CABLE SYSTEMS KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal

Quintas & Quintas Group

Loadbreak Apparatus Connectors

Type MMV-WP Medium Voltage Wind Power Cable


TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

NEC 2014 Code Changes

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

MC, THHN/THWN-2 Copper

INSTALLATION PRODUCTION TESTS

Submarine Power Cables

Easy-On II Terminations

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable

Airfield Ground Lighting

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

200 A 15 kv class loadbreak elbow connector with optional integral jacket seal-canadian Edition

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Power & Control Cable IEC

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

Your Partner in Safe Power Solutions. About RESCAB

600 A 35 kv class separable splices

Power & Control Cables

Power & Control Cables. U o. /U 0.6/1 kv - IEC

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

DURAREEL TRAILING REELING CABLE

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

MEDIUM VOLTAGE POWER CABLES

Caledonian Fire Resistant Optic Fiber Cables

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

High Voltage Joints and Terminations up to 72,5 kv 145 kv

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

Any inquiries, please feel free to contact or Caledonian

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

QTII (X) Series Silicone Rubber Cold Shrink Termination Kits

EXTRA HIGH VOLTAGE c a b l e s

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

600 A 25 kv class BT-TAP deadbreak connector

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

The Following Slides are an Overview of the Hanhe Cable products and facilities For full data on G&W and Hanhe Systems, Call us!

600 A 35 kv class BT-TAP deadbreak connector

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE

Telephone Cables Fire Warning Cables

11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

MEDIUM VOLTAGE TERMINATIONS

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

Transcription:

High Voltage Aluminum, Smooth Aluminum Shield/Sheath XLPE Insulation, HDPE Jacket, 69 kv - 138 kv Features True triple vertical extrusion system for optimum insulation concentricity, and excellent electric field control. Dry cure process. Closed handling of raw materials system to eliminate any contact with ambient, until extrusion process ends. Low dielectric losses. Metallic shield for ground connection. Sunlight resistant jacket. Application Transmission and distribution circuits, in cities with high load densities. Also, for Industrial and Commercial installations. May be installed in wet or dry locations indoors or outdoors in conduit and underground ducts. Standards IEC 60840: Power cables with extruded insulation for rated voltages above 30 kv up to 150 kv. AEIC CS9: Specifications for extruded insulation power cables and their accessories rated above 46 kv through 345 kv. ICEA S-108-720: Standard for extruded insulation power cables rated above 46 kv to 345 kv. Specifications Operating (maximum) voltage: 69 kv (72.5 kv), 115 kv (123 kv) or 138 kv (145 KV) Maximum conductor operation temperatures: Wet and dry locations Normal: 90 C Emergency: 105 C Short Circuit: 250 C Engineering Information 1. Conductor: 1350-H19 Aluminum, Class B or Class 2 filled stranding compacted round or segmental as per ASTM B400 or IEC 60228. Sizes: 500 kcmil up to 4000 kcmil. On request, unfilled conductor. 2. Semiconducting Tape: A semiconducting tape may be applied helically with an overlap, as required. 1 2 3 4 5 3. Conductor Shield: Semiconducting cross-linked polyethylene. 4. Insulation: High quality, heat, moisture, ozone and corona resistant, cross-linked polyethylene (XLPE). 5. Insulation Shield: Semiconducting cross-linked polyethylene. 6. Water Barrier: Semiconducting water blocking tape, helically applied. 7. Metallic Shield/Sheath: Welded smooth aluminum tape longitudinally applied over semiconducting water blocking tapes. 8. Jacket: Black high density polyethylene (HDPE) sunlight resistant thermoplastic compound. 6 7 8 On request, semiconducting PE layer. High Voltage - Primary UD Cable

69 kv Aluminum, XLPE Insulated Size kcmil 500 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Conductor Shape Round Segmental Number of Strands 37 61 61 61 61 85 85 305 305 305 305 Conductor Diameter in 0.74 0.91 1.06 1.21 1.31 1.48 1.57 1.78 1.95 2.12 2.28 Insulation Insulation Thickness mil 380 360 340 330 320 320 310 310 300 300 300 Insulation OD in 1.57 1.71 1.82 2.02 2.09 2.27 2.34 2.55 2.70 2.87 3.03 Metallic Sheath Thickness mil 60 Diameter over sheath in 1.96 2.09 2.2 2.4 2.48 2.65 2.72 2.94 3.09 3.26 3.42 Complete Cable Outside Diameter Net Weight Minimum Bending Radius Maximum Pulling Tension in 2.36 2.50 2.61 2.81 2.88 3.06 3.13 3.35 3.50 3.67 3.83 lb/ft 2.3 2.7 3.0 3.6 3.9 4.3 4.6 5.4 6.1 6.8 7.4 in 49 51 54 58 59 63 64 68 71 75 78 lb 3,000 4,000 6,000 7,500 9,000 10,500 12,000 15,000 18,000 21,000 24,000 Electrical Stress @ U 0 Conductor Shield kv/mm 5.8 5.8 5.8 5.8 5.9 5.8 5.9 5.8 5.9 5.8 5.8 Insulation Shield kv/mm 3.0 3.3 3.6 3.9 4.1 4.1 4.3 4.4 4.6 4.6 4.6 Short Circuit for 0.5 s Conductor ka 33.3 49.9 66.5 83.2 99.8 116.4 133.0 166.3 199.6 232.8 262.6 Sheath ka 28.3 30.3 32.0 34.9 36.0 38.6 39.7 43.0 45.2 47.7 50.2 Conductor Resistance dc @ 20 C Ω/kft 0.035 0.023 0.017 0.014 0.012 0.010 0.009 0.007 0.006 0.005 0.005 dc @ 90 C Ω/kft 0.045 0.030 0.022 0.018 0.015 0.013 0.011 0.009 0.008 0.006 0.006 Capacitance pf/ft 53.1 63.8 74.7 88.3 95.7 105.4 113.4 125.5 139.1 149 158.5 Charging Current A/kft 0.80 0.96 1.12 1.33 1.44 1.58 1.70 1.88 2.09 2.24 2.38 Ampacity @ 90 C (3 ft top of duct, 1 C m/w native, 20 C Ambient, 75% if single-point or cross bonded) Single Circuit Bank A 524 656 769 867 954 1033 1104 1307 1432 1543 1641 Double Circuit Bank A 440 547 637 713 781 842 895 1095 1206 1296 1376 The above data are approximate and subject to normal manufacturing tolerances.

115 kv Aluminum, XLPE Insulated Size kcmil 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Conductor Shape Round Segmental Number of Strands 61 61 61 61 85 85 305 305 305 305 Conductor Diameter in 0.91 1.06 1.21 1.31 1.48 1.57 1.78 1.95 2.12 2.28 Insulation Insulation Thickness mil 730 680 630 610 590 580 570 550 540 540 Insulation OD in 2.46 2.51 2.63 2.68 2.82 2.89 3.08 3.21 3.36 3.52 Metallic Sheath Thickness mil 60 Diameter over sheath in 2.84 2.90 3.02 3.07 3.20 3.27 3.48 3.61 3.76 3.92 Complete Cable Outside Diameter Net Weight Minimum Bending Radius Maximum Pulling Tension Electrical Stress @ U 0 in 3.25 3.30 3.42 3.47 3.61 3.68 3.88 4.01 4.16 4.32 lb/ft 4.1 4.4 4.8 5.1 5.5 5.8 6.7 7.3 8.1 8.7 in 67 68 70 71 74 75 79 82 85 88 lb 4,000 6,000 7,500 9,000 10,500 12,000 15,000 18,000 21,000 24,000 Conductor Shield kv/mm 5.8 5.8 5.9 5.9 5.9 5.9 5.8 5.9 5.9 5.8 Insulation Shield kv/mm 2.3 2.6 3.0 3.2 3.4 3.5 3.6 3.8 4.0 4.0 Short Circuit for 0.5 s Conductor ka 49.9 66.5 83.2 99.8 116.4 133.0 166.3 199.6 232.8 262.6 Sheath ka 41.5 42.3 44.0 44.8 46.9 47.9 50.9 52.9 55.1 57.5 Conductor Resistance dc @ 20 C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 0.007 0.006 0.005 0.005 dc @ 90 C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 0.009 0.008 0.006 0.006 Capacitance pf/ft 38.5 44.5 53.2 57.2 64.0 67.6 75.1 82.8 89.5 94.8 Charging Current A/kft 0.96 1.11 1.33 1.43 1.60 1.69 1.88 2.07 2.24 2.37 Ampacity @ 90 C (3 ft top of duct, 1 C m/w native, 20 C Ambient, 75% if single-point or cross bonded) Single Circuit Bank A 651 762 859 946 1023 1093 1324 1453 1568 1658 Double Circuit Bank A 549 639 718 787 848 903 1091 1192 1282 1360 The above data are approximate and subject to normal manufacturing tolerances.

138 kv Aluminum, XLPE Insulated Size kcmil 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 Conductor Shape Round Segmental Number of Strands 61 61 61 61 85 85 305 305 305 305 Conductor Diameter in 0.91 1.06 1.21 1.31 1.48 1.57 1.78 1.95 2.12 2.28 Insulation Insulation Thickness mil 970 890 810 790 760 740 710 700 680 670 Insulation OD in 2.94 2.93 2.99 3.04 3.16 3.21 3.36 3.51 3.64 3.78 Metallic Sheath Thickness mil 60 Diameter over sheath in 3.32 3.32 3.38 3.43 3.54 3.59 3.76 3.91 4.04 4.18 Complete Cable Outside Diameter Net Weight Minimum Bending Radius Maximum Pulling Tension Electrical Stress @ U 0 in 3.73 3.72 3.78 3.83 3.95 4.00 4.16 4.31 4.44 4.58 lb/ft 5.2 5.4 5.7 6.0 6.4 6.6 7.4 8.1 8.9 9.5 in 76 76 77 78 81 82 85 88 90 93 lb 4,000 6,000 7,500 9,000 10,500 12,000 15,000 18,000 21,000 24,000 Conductor Shield kv/mm 5.9 5.9 5.9 5.9 5.8 5.9 5.9 5.8 5.9 5.9 Insulation Shield kv/mm 1.9 2.3 2.7 2.8 3.0 3.1 3.4 3.5 3.7 3.8 Short Circuit for 0.5 s Conductor ka 49.9 66.5 83.2 99.8 116.4 133.0 166.3 199.6 232.8 262.6 Sheath ka 48.7 48.5 49.4 50.2 51.9 52.7 55.1 57.3 59.3 61.4 Conductor Resistance dc @ 20 C Ω/kft 0.023 0.017 0.014 0.012 0.010 0.009 0.007 0.006 0.005 0.005 dc @ 90 C Ω/kft 0.030 0.022 0.018 0.015 0.013 0.011 0.009 0.008 0.006 0.006 Capacitance pf/ft 32.3 37.3 44.7 47.6 53.1 56.3 63.5 68.5 74.5 79.7 Charging Current A/kft 0.97 1.12 1.34 1.43 1.59 1.69 1.91 2.06 2.24 2.39 Ampacity @ 90 C (3 ft top of duct, 1 C m/w native, 20 C Ambient, 75% if single-point or cross bonded) Single Circuit Bank A 658 756 853 939 1015 1079 1305 1430 1543 1641 Double Circuit Bank A 540 637 712 777 842 896 1079 1178 1225 1300 The above data are approximate and subject to normal manufacturing tolerances.

Notes In this publication, conductor sizes are given in kcmil. According to the best practice in industry, when using pulling eyes attached to phase conductors, the maximum mechanical pulling tension that can be applied to each conductor or group of conductors being installed in ducts, should not be higher than 6,000 lbf. Doing calculations of cable pulling tensions prior to each installation, increases the possibilities of a safe and secure operation. Installation conditions taken as reference for ampacity calculations are: 1. One and two three phase circuits, cables in underground buried ducts, one cable per duct, flat parallel configuration with a distance between duct centers of twice the OD of each cable. 2. 75% Load Factor. 3. Single point or cross bonded shield grounding connection. 4. Ambient Ground Temperature, Ta = 20 C. 5. Deep to top of ducts, 3 ft. 6. Ground Thermal Resistivity: 1 C m/w. For this publication, ampacity values were calculated according to the available best engineering practice (per IEC 60287). However, they should be considered as reference values only, applicable to the conditions described below. For other cases, correction factors can be applied as follows: Deep, m 1.0 1.2 1.3 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Factor 1.03 1.01 1.00 0.98 0.95 0.93 0.91 0.89 0.88 0.87 0.86 Soil Thermal Resistivity ( C ) 0.8 1.0 1.2 1.5 2.0 2.5 Factor 1.09 1.00 0.93 0.85 0.75 0.67 Soil Temperature ( C ) 10 15 20 25 30 35 40 Factor 1.07 1.04 1.00 0.96 0.92 0.88 0.84 Temperature Correction Factor Distance Between Centers mm 400 600 800 1000 1 circuit 1.00 1.00 1.00 1.00 2 circuit 0.79 0.83 0.87 0.89 3 circuit 0.70 0.75 0.78 0.81 4 circuit 0.64 0.70 0.74 0.78 Only nominal dimensions are included in this publication. For accessary selection, please contact our Sales Department.

This page intentionally left blank