ROOFMASTER STEF-HT ROOF FAN

Similar documents
ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-ATEX ROOF FAN

ROOFMASTER STEF ROOF FAN

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ROOF FAN ROOFMASTER STEC

Kitchen exhaust fan GLEB

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

Centriflow Plus EC. Technical data

MAJAX-2 GENERAL SPECIFICATION

KSOF Fire damper valve

Exhaust air diffuser EYMA-2 and air intake device DYMA-1

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

CTVK Supply air diffuser

Sky Wing. Contents. Power Roof Ventilator

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

HIGH TEMPERATURE TWIN SQUIF FANS

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

Pressure control damper ERPA

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

KTI Supply air valve. Product Facts. Product code example. Quick Selection

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection


Multifunctional 400ºC/2h and 300ºC/2h roof fans

Bifurcated Case Axial Fans (BIFA)

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

BPF. Centrifugal Plug Fans

Fire damper ETPR. Specifications. Product code example Fire damper ETPR

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

AXIAL FANS Catalogue CN0050C01 May 2008

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

ACOUSTIC CABINET FANS CVAB / CVAT Series

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

SQUIF HIGH TEMPERATURE FANS

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

OPTIVENT Housing HVSA, HVSL

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

KSOM Control exhaust valve

MegaBox Product-specific information

HIGH-POWERED VENTILATORS

CHMT Series, F Rated Fans

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

Medium Pressure Centrifugal Fans

IN-LINE CENTRIFUGAL DUCT FANS VT Series

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Square Mixed Flow Fans (MFQ)

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Section 4. Axial Fans - Section 4

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Size and Configurations

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

ExpressBuild STANDARD FAN RANGE

Plate mounted axial flow fans HXBR / HXTR Series

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

AXUS HIGH TEMPERATURE AXIAL FANS

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

AC Commercial Fans Edition. ErP ready

Centrifugal medium-pressure fans fitted with multi-blade

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Uniclass L7534. Manufacture controlled to ISO9001

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Short casing. Long casing (L version) Commercial premises

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

ACOUSTIC CABINET FANS CVB / CVT Series

ESAS Smoke control damper

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

CENTRIFUGAL IN-LINE FANS VENT Series

ETPR-E-1 FIRE DAMPER» TECHNICAL CATALOGUE

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

Mixed Flow Roof Fans (RMH)

Regulation and shut-off damper SPB and SPC

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CVHT Series - F rated cabinet fans

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

Section 4 e c tio - P lat F a n s

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

In-line rectangular fans. Technical Catalogue

Transcription:

fire safety Air movement Roof Fans ROOFMASTER STEF-HT ROOF FAN» Technical CATALOGuE

Contents ROOFMASTER STEF-HT...3 Performance Data...4 Performance Table...5 General description...6 Fan Chart-explanation and definitions...7 STEF-1...8 STEF-2...9 STEF-3...10 STEF-4...11 STEF-5...12 STEF-6...13 STEF-7...14 ROOFMASTER - Accessories BOGA roof curb with insulation... 15 Safety switch SAFE... 17 Mounting frame MORA...17 ROOFMASTER - Wiring Star connection...18 Fläkt Woods 9552 GB 2015.04.23 2 Specifications are subject of alteration without further notice

ROOFMASTER STEF-HT Features Electrical supply 3x400 V 50 Hz Ambient temperature range 20 C +40 C (dual purpose use) Sizes STEF-1, -2, -3, -4, -5, -6, -7. Material and design The fan casing is made of black pre-painted galvanized sheet or alu minium and zinc coated sheet steel. The surface treatment meets the requirements of environmental class C4 (EN ISO 1294-2). The fan is insulated inside against noise. The fan discharges air upwards. The motor com partment is equipped with two hatches, which open in case of increased temperature. Additional cooling is arranged for the motor. The fan is equipped with a safety switch. Impeller The impeller is made of galvanized steel sheet (size 7 is made of welded steel and painted) and have a backward curved blades. The impeller is dynamically balanced to class Q6.3 in accordance with VDI 2060. The blades on the back side of the impeller support the cooling of the motor. Product Code STEF-a--c-6-e a = size a (1, size2, 3, 4, 5, 6, 7) 0 = three 0 phase motor = number b of poles c 1= painted 1 galvanized sheet metal, black 2= Al/Zn coated sheet 2 steel d 6 = high temperature 6 (HT) version e = e generation Motor Three-phase fans are using IEC standard 3-phase AC-motors, which are located outside the air stream. They are cooled by the outside air. Cooling fan of the motor is made of steel. Fläkt Woods 9552 GB 2015.04.23 3 Specifications are subject of alteration without further notice

Performance Data ROOFMASTER STEF-HT 3 phase 600 500 400 Static Pressure, Pa 300 200 STEF-2-004 STEF-3-004 STEF-4-004 100 0 0 1000 2000 3000 4000 m 3 /h 5000 0 0,2 0,4 0,6 0,8 1,0 1,2 Volume Flow m 3 /s 1000 900 800 700 600 STEF-5-004 Static Pressure, Pa 500 400 STEF-6-006 STEF-7-006 300 200 100 STEF-5-006 0 0 5000 10000 15000 m 3 /h 20000 0 1 2 3 Volume Flow 4 5 m 3 /s Fläkt Woods 9552 GB 2015.04.23 4 Specifications are subject of alteration without further notice

Performance Table ROOFMASTER STEF-HT 3 phase Air flow m 3 /h as function of static pressure Pressure (Pa) 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 STEF-2-004 1674 1552 1393 1192 889 230 STEF-3-004 3485 3341 3175 2981 2754 2480 2146 1710 925 STEF-4-004 4536 4352 4158 3953 3722 3470 3175 2822 2369 1706 STEF-5-004 7459 7268 7063 6840 6595 6329 6041 5720 5364 4968 4518 3992 3341 2347 STEF-6-006 9616 9288 8906 8460 7924 7283 6520 5612 4432 STEF-7-006 18623 18227 17798 17327 16808 16240 15628 14958 14238 13464 12629 11718 10696 9475 7754 Airflow m 3 /h Fläkt Woods 9552 GB 2015.04.23 5 Specifications are subject of alteration without further notice

General description Application/specification The smoke extract roof fan STEF is designed to be used as an exhaust fan in ventilation systems conveying the media up to a maximum of 400 C for 120 min and confirming with the standard EN 12101-3 and being CEmarked according to this standard. Easy installation and service Product type STEF Fan type: Powered smoke and heat exhaust ventilator Class: F400(120) Notified body: SP Technical Research Institute of Sweden Certificate nr: 0402-CPD-406105 Temperature class: F400(120) Motor: F400(120) classified class B/class F motor for fan The capacity measurement has been performed according to ISO 5801:2007 and the sound power level to surrounding according to ISO 3741:1999. Can be used as a standard roof fan up to an air temperature of 40 C. The fan casing is made of black pre-painted galvanized sheet or aluminium and zinc coated sheet steel. The casing and motor-impeller section can be swung out for easy service and maintenance. Impeller is made of galvanized sheet steel (size 7 is made of welded steel and painted) and has backward curved blades. The motor is outside the airstream and has additional cooling by outside air. The fan discharges air upwards. Accessories: Safety switch SAFE as standard. Quiet operation The inside of the fan casing and the side plates of the motor compartment have sound insulation. The fan itself has very low sound values. Material and design The fan casing is made of black pre-painted galvanized sheet or aluminium and zinc coated sheet steel. STEF-HT can be used in industrial areas or close to the sea as the surface treatment meets the requirements of environmental class C4 (EN ISO 1294-2). The fan is insulated inside against noise. The fan discharges air vertically. STEF-HT can be installed by using a roof curb BOGA or directly on to the concrete. It is equipped with opening hinges as standard. The impeller and duct can be easily cleaned. The roof can be removed to perform the maintenance of the motor. Motor and impeller Three-phase fans are using IEC standard 3-phase AC-motors, which are located outside of the air stream. The motors have cooling fans made of metal and additional cooling from outside temperature. The motor compartment is equipped with hatches, which will open when the temperature has reached the level where locking fuse smelts. In standard ventilation the maximum exhaust temperature is + 40 C. Impeller is made of galvanized sheet steel (size 7 is made of welded steel and painted) and has backward curved blades. Fläkt Woods 9552 GB 2015.04.23 6 Specifications are subject of alteration without further notice

Fan chart-explanation and definitions Symbols The total A-weighted sound power level to surroundings, L wa, can be read in the fan chart. The correction coefficients by octave bands can be read in the chart below. The sound power level by octave band to the duct or to the surroundings (without A-weighting) can be obtained by using the following formula. ❸ Lwoct = L wa + Koct ❷ Sound pressure level and remote attenuation Distance L (m) 1 3 5 10 15 20 25 30 40 Attenuation L (db) 7 17 22 28 31 34 36 37 40 ❹ The total sound pressure level to surroundings at different distances can be estimated using the following formula: LpA = L wa - L ❶ ❶ Q v Airflow m 3 /s ❷ Δp s Static pressure rice Pa ❸ η Overall effeciency (impeller and motor) % at max rotation speed ❹ L wa A-weighted total sound level to db(a) surroundings L woct Sound power level by octave bands db (without A-weighting) K oct Correction when diving into db different octave bands ΔL Remote attenuation (given values db calculated for an ideal case in a halfspace) Fläkt Woods 9552 GB 2015.04.23 7 Specifications are subject of alteration without further notice

STEF-2 STEF-2-004 Correction Koct (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM 63 125 250 500 1000 2000 4000 8000 STEF-2 Surroundings 0 1500-3 8 3-2 -8-13 -17-16 STEF-2 To the inlet duct 0 1500 1 1-3 -6-1 -5-11 -19 For information how to calculate sound data, sound pressure level and remote attenuation, see page 7. Motor data STEF- Speed r/min Motor nominal data at 50 Hz Output kw Voltage V Current A 2-004-c 1380 0.12 3x400/3x230 0,44/0,8 Totally enclosed squirrel cage motors for power roof ventilator STEF-HT. IP 55 IC 411. Insulation class F. Product code Dimensional drawing Roof Fan STEF- 2- - c- 6-3 Size 0 = three phase motor Number of poles c 1 = galvanised painted sheet metal, black 2 = coated sheet Al/Zn steel Weight 31 kg d = 6 HT version Generation Fläkt Woods 9552 GB 2015.04.23 9 Specifications are subject of alteration without further notice

STEF-3 STEF-3-004 Correction Koct (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM 63 125 250 500 1000 2000 4000 8000 STEF-3 Surroundings 0 1500-8 3 6-4 -8-13 -17-16 STEF-3 To the inlet duct 0 1500-9 -6-6 -6-6 -10-15 -19 For information how to calculate sound data, sound pressure level and remote attenuation, see page 7. Motor data STEF- Speed r/min Motor nominal data at 50 Hz Output kw Voltage V Current A 3-004-c 1400 0,55 3x400/3x230 1,65/2,9 Totally enclosed squirrel cage motors for power roof ventilator STEF-HT. IP 55 IC 411. Insulation class F. Product code Dimensional drawing Roof Fan STEF- 3- - c- 6-3 Size 0 = three phase motor Number of poles c 1 = galvanised painted sheet metal, black 2 = coated sheet Al/Zn steel Weight 45 kg d = 6 HT version Generation Safety switch SAFE is automatically included in STEF HT delivery Fläkt Woods 9552 GB 2015.04.23 10 Specifications are subject of alteration without further notice

STEF-4 STEF-4-004 Correction Koct (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM 63 125 250 500 1000 2000 4000 8000 STEF-4 Surroundings 0 1500-8 3 6-5 -10-15 -20-25 STEF-4 To the inlet duct 0 1500-8 -6-8 -7-5 -10-17 -22 For information how to calculate sound data, sound pressure level and remote attenuation, see page 7. Motor data STEF- Speed r/min Motor nominal data at 50 Hz Output kw Voltage V Current A 4-004-c 1410 0,75 3x400/3x230 2,0/3,5 Totally enclosed squirrel cage motors for power roof ventilator STEF-HT. IP 55 IC 411. Insulation class F. Product code Dimensional drawing Roof Fan STEF- 4- - c- 6-3 Size 0 = three phase motor Number of poles c 1 = galvanised painted sheet metal, black 2 = coated sheet Al/Zn steel Weight 50 kg d = 6 HT version Generation Fläkt Woods 9552 GB 2015.04.23 11 Specifications are subject of alteration without further notice

STEF-5 STEF-5-004 Correction Koct (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM 63 125 250 500 1000 2000 4000 8000 STEF-5 Surroundings 0 1500-8 3 6-5 -12-16 -19-22 STEF-5 To the inlet duct 0 1500-11 -7-8 -9-11 -11-18 -25 For information how to calculate sound data, sound pressure level and remote attenuation, see page 7. Motor data STEF- Speed r/min Motor nominal data at 50 Hz Output kw Voltage V Current A 5-004-c 1420 1,5 3x400/3x230 3,6/6,1 Totally enclosed squirrel cage motors for power roof ventilator STEF-HT. IP 55 IC 411. Insulation class F. Product code Dimensional drawing Roof Fan STEF- 5- - c- 6-3 Size 0 = three phase motor Number of poles c 1 = galvanised painted sheet metal, black 2 = coated sheet Al/Zn steel Weight 66 kg d = 6 HT version Generation Safety switch SAFE is automatically included in STEF HT delivery Fläkt Woods 9552 GB 2015.04.23 12 Specifications are subject of alteration without further notice

STEF-6 STEF-6-006 Correction Koct (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM 63 125 250 500 1000 2000 4000 8000 STEF-6 Surroundings 0 1500 3 8 3-2 -8-12 -15-21 STEF-6 To the inlet duct 0 1500 3 6 1-2 -7-7 -12-15 For information how to calculate sound data, sound pressure level and remote attenuation, see page 7. Motor data STEF- Speed r/min Motor nominal data at 50 Hz Output kw Voltage V Totally enclosed squirrel cage motors for power roof ventilator STEF-HT. IP 55 IC 411. Insulation class F. Current A 6-006-c 930 1,1 3x400/3x230 3,3/5,7 Product code Dimensional drawing Roof Fan STEF- 6- - c- 6-3 Size 0 = three phase motor Number of poles c 1 = galvanised painted sheet metal, black 2 = coated sheet Al/Zn steel Weight 116 kg d = 6 HT version Generation Safety switch SAFE is automatically included in STEF HT delivery Fläkt Woods 9552 GB 2015.04.23 13 Specifications are subject of alteration without further notice

STEF-7 STEF-7-006 Correction Koct (db) Octave band mid-frequency (Hz) Fan code Sound path MinRPM MaxRPM 63 125 250 500 1000 2000 4000 8000 STEF-7 Surroundings 0 1500 3 7 3-3 -7-12 -15-21 STEF-7 To the inlet duct 0 1500 1 3 5 1-2 -4-10 -15 For information how to calculate sound data, sound pressure level and remote attenuation, see page 7. Motor data Motor nominal data at 50 Hz STEF- Speed r/min Output kw Voltage V Current A 7-006-c 960 4,0 3x400/3x230 8,9/15,4 Totally enclosed squirrel cage motors for power roof ventilator STEF-HT. IP 55 IC 411. Insulation class F. Product code Dimensional drawing Roof Fan STEF- 7- - c- 6-3 Size 0 = three phase motor Number of poles c 1 = painted galvanised sheet metal, black 2 = Al/Zn coated sheet steel Weight 199 kg d = 6 HT version Generation Fläkt Woods 9552 GB 2015.04.23 14 Specifications are subject of alteration without further notice

Accessories Safety switch SAFE The safety isolation switch has been tested to IEC 947-3. Safety switch is automatically included in the delivery of STEF-HT. Fläkt Woods 9552 GB 2015.04.23 17 Specifications are subject of alteration without further notice

Wiring Star connection Three phase motor, single speed E4503497 Fläkt Woods 9552 GB 2015.04.23 18 Specifications are subject of alteration without further notice