PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

Similar documents
PEC 827E. 120 VAC AC Distribution Shelf. Critical Power Product Manual

153M -48V POWER PLANT 5000 AMP

SM50F48PM (-48V) Rectifier Module. Critical Power Product Manual. Part Number: SM50F48PMPD.

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

:: :: TFD4 :: TFD6

High Frequency SineWave Guardian TM

PSX-240 Enclosed Autotransformer Installation Manual

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Demarcation Fuse Alarm Panel

POWERLINE 2000 Energy Management System TM

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Product Manual Select Code Comcode Issue 9 September Secondary DC Power Distribution Bay H

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

AIS and 40 kva 400 V. Site Preparation and Installation Manual

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

Sentry Battery Charger. Installation and Operations Manual Section 75

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Battery Control Center - Diesel

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

TOTAL POWER MODULE (TPM) HIGH FREQUENCY FLOAT CHARGER / BATTERY ELIMINATOR WITH UNIVERSAL INPUT USED WITH A TOTAL POWER CAGE (TPC)

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

30A SMART ENERGY MANAGEMENT SYSTEM TM

User s Manual. Automatic Switch-Mode Battery Charger

A63 DC/DC CONVERTER INSTRUCTION MANUAL ECN/DATE /05 INSTRUCTION DRAWING NUMBER: CPN INSTRUCTION MANUAL FOR A63 DC/DC CONVERTER

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

General Precautions. Personnel Precautions

Fuse Panels, Fuse Holders and Fuses

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

INSTRUCTION MANUAL FOR PC63 CAGE

PSJ-2212, PSJ-3612, PSJ-4424

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

DP140e. Installation & Operations Manual

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

O W N E R ' S M A N U A L


5067 Mini-BDFB Battery Distribution Fuse Bay

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

DC REGULATED POWER SUPPLY

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

SB SWITCH CONTROL BOX

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Rental Industry Safety Tester Safe Check 5s

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

PowerWorx DSX Series GMT Fuse Panel User Manual

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL

CTFRP Series Power Supplies

February EN-B POWER CHARGE PSC-700. Power Supply / Maintenance Charger for 12-volt Batteries/Systems INSTRUCTION MANUAL

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

IMPORTANT SAFEGUARDS

IMPORTANT SAFETY INSTRUCTIONS

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

E.S.P. Embedded Sensing Probes for Motor Brushes

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MASTERsine Inverter PXA Series Installation Guide

Fuse Panels, Fuse Holders and Fuses

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

GE Sensing & Inspection Technologies

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

CONTROL FEATURES AVAILABLE OPTIONS

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Installation Power Management Unit Battery Cables and Battery Harness

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

AT30 SERIES BATTERY CHARGER

ANZI Transfer Switch and Generator Wiring Installation Addendum

Foreword

Transcription:

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay Product Manual Part Number: 438 5068PD Issue 32, March 2010 Engineer: H. D. Approved: H. D. PECO II, Inc. 1376 State Route 598 Galion, OH 44833-0910 Phone: 800.999.PECO (7326) Visit us on the web at www.peco2.com

-This page intentionally left blank- Page 2 Issue 32, March 2010

Table of Contents TABLE OF CONTENTS...3 FOREWORD...5 PRODUCT INFORMATION...5 WARNINGS...6 CAUTIONS...6 SECTION 1: SPECIFICATIONS...7 1.1 GENERAL...7 1.2 BAY ALARM PANEL...8 1.3 DIGITAL METER AND ALARM PANEL...9 1.4 GROUND BUS ASSEMBLY (Two (2) Options)...10 1.5 CIRCUIT BREAKER PANEL...11 1.6 DISTRIBUTION FUSE PANEL...11 1.7 ENVIRONMENTAL RATINGS...11 SECTION 2: DIMENSIONS...13 SECTION 3: INSTALLERS CONNECTIONS...15 3.1 GROUND BUS BAR (TOP FEED)...15 3.2 GROUND BUS BAR (BOTTOM FEED)...15 3.3 BATTERY BUS BARS (A, B, C, & D)...15 3.4 GROUND BUS BAR & BATTERY (Distribution)...15 SECTION 4: INSTALLERS CONNECTIONS...17 4.1 INSTALLERS INFORMATION NOTES...17 ATTACHMENTS...19 SECTION 5 SECTION 6 SECTION 7 SECTION 8 Description Attachments Attachment # J Spec PEC 5068 BDFB 48V TPS 4385068P Att Schematic, PEC 5068 BDFB 4395068P Att Schematic, PEC 5068 BDFB 4395068T-1 Att Schematic Fuse Clearing Panel 4390001P Att Schematic, Cir Brkr Panel 19 & 23 4390006P Att Schematic, Alarm Pnls, +24 V 4390016P-2 Att Schematic, Meter & Alarm Panel 4393385 Att Schematic, Dig Meter 131N-L100 4393501 Att Issue 32, March 2010 Page 3

- This page intentionally left blank - Page 4 Issue 32, March 2010

Foreword PECO II, Inc. PEC 5068 BDFB Manual This manual is intended to help the user of the PEC 5068 BDFB to install, test, troubleshoot, and understand the system. If you should have any questions or problems, please contact one of the following sources: SERVICE - If for any reason further assistance is needed on any power equipment, complete engineering and field service groups are available in Galion, Ohio, to assist you in any way possible. CALL: 419.468.7700 Field Service OR 800.999.PECO (7326) and ask for Field Service PARTS ORDERING - Replacement parts for power equipment may be obtained by forwarding a Purchase Order to: PECO II, Inc OR Fax to: 419.462.8180 P. O. Box 910 Galion, Ohio 44833 Include the following information: A. PECO II part number and engineering level of equipment B. If part is electrical, give circuit reference numbers and PECO II part numbers. C. If part is mechanical in nature, give description as to where it is used. RETURN & REPAIR - Equipment may be returned to the Factory for repair. In order to do this, the procedure must be as follows: A. Call: 419.468.7700 Field Service OR 800.999.7326 and ask for Field Service B. Request a Returned Material Authorization (RMA) number for the defective equipment. C. Return material prepaid to: PECO II, Inc 1376 State Route 598 Galion, Ohio 44833 Attn: Field Service Dept Product Information Please take a moment when the product is new to fill in this information. This data will allow faster service when calling PECO II to order accessories, spare parts, or request field service. First, locate the product information label. This is typically located on the upper front of the equipment frame, or on the rear of the frame. Fill in the part number, as it appears on the label, in the space below. PART NUMBER DATE CODE: SERIAL NUMBER ECN Level: 8 P Issue 32, March 2010 Page 5

Warnings 1. Electrical shock hazard. Do not attempt to remove, maintain, or install this equipment with power applied. Personnel that attempt to work on this equipment with the power applied may subject themselves or others to electrical shock that may cause serious injury or death. 2. The use of this equipment by unauthorized or untrained personnel should not be attempted. Personnel that work on this equipment without the proper training may subject themselves or others to electrical shock that may cause serious injury or death. 3. Do not attempt to work on this equipment if it is, or has been, exposed to a high moisture condition. It is recommended the equipment be returned to PECO II to be properly tested. Working on this equipment during a high moisture condition subjects the user to electrical shock that may cause serious injury or death. 4. Use of an attachment other than one approved by PECO II will void any and all warranties, implied or other, and will increase risk of fire, or may possibly cause electrical shock, injury, or death to personnel. Cautions 1. Follow proper grounding instructions. 2. If connecting batteries, remove the battery-boxfuse or trip the circuit breaker. Check batteries and connections for proper polarity and power before connecting the batteries to the system 3. To remove the circuit breakers or fuses, the DC and/or AC input to the system will need to be disconnected, thereby disabling the system output to the load(s). Take the necessary precautions and inform the plant engineer that the system output power to the loads will be disabled. 4. Before performing any maintenance, ensure AC or DC power is not applied to the system. 5. Fuse holders, fuses, and circuit breakers are not to be loaded to more than 80 percent of their ampere rating. 5. Do not operate this equipment if it has been dropped or otherwise damaged. Trying to operate this equipment if it has been damaged subjects yourself or others to electrical shock that may cause serious injury or death. 6. Before you proceed, ensure the input source is not live and the input circuit breaker(s)/fuse(s) has been tripped or removed. If these procedures have not been followed and the input/output power is live, serious personnel injury or death may occur. 7. A rack/shelf may contain several operating systems. If there is another system in the general area you want to install this system, be cautious of any exposed connectors or wires and, with permission, remove power to the other systems. Failure to take the necessary safety precautions subjects the installer or maintenance personnel to severe electrical shock that may cause serious injury or death. 8. This equipment may connect to lead-acid batteries. Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. Wash hands after touching batteries. Page 6 Issue 32, March 2010

1.1 GENERAL. PECO II, Inc. PEC 5068 BDFB Manual SECTION 1: SPECIFICATIONS The PEC 5068 Battery Distribution Fuse Bay (BDFB) is designed to provide protection (Circuit Breaker or Fuse Distribution) of -48 VDC to Central Office Equipment, etc. Visual alarm signals are given whenever any circuit breaker or fuse "fails". The PEC 5068 bay (BDFB) can be top or bottom fed to facilitate ease of installation. The PEC 5068 is a distribution bay in two (2) widths to mount 19" and 23" fuse panels. These bays are provided in heights of 7'-0", 9'-0", and 11'-6". The standard depth is 16", and an optional depth of 12", is available if required. The PEC 5068 BDFB Bay can accommodate up to ten (10) load centers. Each load center is rated at 500 Amps, 2000 Amps maximum and consists of the following: A. Ground Bus Assembly (Rated at 2000 Amps). B. Circuit Breaker Panel consisting of: 1. 23" mounting panel for 24 Circuit Breakers (maximum). or 19" mounting panel for 19 Circuit Breakers (maximum). 2. Common Bus Bar (500 Amps). C. Fuse Panel Assembly consisting of the following: 1. 23" mounting panel for 17 TPS fuse holders (maximum). or 19" mounting panel for 13 TPS fuse holders (maximum). 2. Common Bus Bar (500 Amps). D. Meter & Alarm Panel Assembly consisting of the following: 1. Digital Meter Assembly. 2. Rotary Switch- six (6) position or (eleven) 11 position. 3. Fuse Holder Assembly - five (5) position. 4. Fuse Alarm PWB Assembly. 5. One to ten 500 Amp Shunts (located remotely). E. Fuse Alarm Panel Assembly consisting of the following: 1. Alarm Extension Module. 2. Fuse Alarm Lamp. Additional equipment available on an as required basis is as follows: A. Circuit Breaker Kit (for additional distribution). Issue 32, March 2010 Page 7

B. Fuses (for additional distribution). 1.2 BAY ALARM PANEL The Bay Alarm Panel monitors any fuse alarm (FA) from either Distribution Fuse or Circuit Breaker Panels within the bay. The Bay Alarm Panel provides the following: A. ALARM EXTENSION MODULE 1. The module operates using either (+) or (-) polarity with a voltage range of 20 to 60 VDC. 2. Terminal 1 is the input GND termination point. 3. Terminal 15 is the Fuse Alarm (FA) input termination point. 4. Terminal 2 is the Unit Fail alarm (UF) input termination point. 5. Terminals 9 thru 11 and 12 thru 14 are available for Fuse Fail Alarm outputs. The outputs are two (2) Dry "Form C" contacts. 6. Terminals 3 thru 5 and 6 thru 8 are available for Unit Fail Alarm outputs. The outputs are two (2) Dry "Form C" contacts. B. FUSE ALARM PANEL. The Fuse Alarm lamp (Red), located on the Bay Alarm Panel, will light during a Fuse or Circuit Breaker failure within the Bay. It remains "ON" until the failure has been corrected. C. ALARM INDICATORS 1. Distribution Fuse Alarms (FA): If any Distribution Fuse should "open" the following will happen: a. FA LED (Red) will light on the Distribution Fuse Panel associated with the "open" fuse. b. FA LED (Red) will light on the Digital Meter & Alarm Panel. c. FA lamp (Red) on the Bay Alarm Panel will light. d. FA relay on the Alarm Extension Module should operate and activate the external office alarms (if connected). 2. Distribution Circuit Breaker Alarms (FA): If any Distribution Circuit Breaker should "trip" the following should happen: a. FA LED (Red) will light on the Distribution Circuit Breaker Panel associated with the "tripped" circuit breaker. b. FA LED (Red) will light on the Digital Meter & Alarm Panel. c. FA LED (Red) will light on the Bay Alarm Panel. d. FA relay on the Alarm Extension Module should operate and activate the external office alarms (if connected). NOTE: Circuit Breaker Mod Kits (lists 100-113) does not generate an alarm when manually turned "OFF". An alarm is only generated when the circuit breaker is "electrically" turned "OFF". Page 8 Issue 32, March 2010

1.3 DIGITAL METER AND ALARM PANEL The Digital Meter and Alarm Panel is designed to monitor the volts and current of the one to ten 500 Amp loads of PEC 5068 as follows: A. To read volts, the meter switch should be in the "VOLTS" position. A rotary selector switch is provided to switch the current monitoring devise (50 MV Shunt) to the voltmeter. The switch positions are as follows: ROTARY SELECTOR SWTICH SW POS. 6-POS. SWITCH 11-POS. SWITCH 1 2 3 4 5 6 7 8 9 10 11 Shunt "A" Bus Shunt "B" Bus Shunt "C" Bus Shunt "D" Bus Spare Spare Bypass Shunt "A" Bus Shunt "B" Bus Shunt "C" Bus Shunt "D" Bus Shunt "E" Bus Shunt "F" Bus Shunt "G" Bus Shunt "H" Bus Shunt "I" Bus Shunt "J" Bus NOTE: During the time that the Volts/Amps switch is in the "VOLTS" position, the bus voltage will be read, depending on the position of the rotary switch. B. To read current, the meter switch should be in the "AMPS" position. A common resistor network is provided to properly read a 500 Amp (50 mv) Shunt with the digital voltmeter. NOTE: During the time that the Volts/Amps switch is in the "Amps" position, the bus current will be read, depending on the position of the rotary switch. C. ALARM BATTERY SUPPLY (ABS) FUSE HOLDER ASSEMBLY The Alarm Battery Supply (ABS) Fuse Holder Assembly provides the following: 1. Fused battery power for alarm circuits and miscellaneous light loads. 2. Battery source for alarming if an ABS fuse "Opens". 3. The input source (Battery) is brought in on terminal "C" of the fuse block. Individual fused outputs leave on Terminal "B" of each fuse holder. Terminal "A" is the alarm out connection if a fuse "opens". D. FUSE ALARM PWB ASSEMBLY The Fuse Alarm PWB assembly is located on the Digital Meter & Alarm Panel. When a fuse alarm signal is received from any fuse or circuit breaker panel in the PEC 5068, the following will happen: 1. Fuse Alarm LED (FA) will light. 2. FA relay (K1) will operate. 3. Visual Fuse Fail alarm output signal will be extended through the Dry "Form C" contacts of the FA relay at terminals TS1-4 (Com), TS1-3 (NC), and TS1-5 (NO). Issue 32, March 2010 Page 9

4. Audible Fuse Fail alarm output signal will be extended through the Dry "Form C" contacts of FA relay at terminals TS1-9 (Com), TS1-8 (NC), and TS1-10 (NO). NOTE: To silence the Audible Alarm (if equipped) during a Fuse Alarm condition, depress ACO switch (S2). Relay K2 (ACO) will operate, silencing the Audible Alarm. The (ACO) relay K2 will remain operated until the alarm signal has been "removed". 5. Terminal TS1-2 is the GND termination input point. 6. Terminal TS1-1 is the GND output point to the fuse alarm lamp (DS1-R), located near the top of bay. 7. Terminal TS1-6 is the -48 VDC termination point to the fuse alarm lamp and "FA" input to Alarm Extension Module, located on the Fuse Alarm Panel Assembly. 1.4 GROUND BUS ASSEMBLY (Two (2) Options) A. EXTERNAL GROUND BUS ASSEMBLY (Beneath a raised floor or on the plant superstructure) The External Ground Bus Assembly can be supplied with either 4" or 6" bus bars. Two (2) different arrangements of the Bus Bars can be made and are as follows: 1. Stacked Bus Bars for the number of Gnd Returns on an "as required" basis. or 2. Sandwiched Bus Bars, which increases the thickness of the bars providing greater Ampere Rating. These Bus Bars can also be stacked, as in Item 1 above. NOTE: See drawing J4385068P for options and crimp lug capacity. B. INTERNAL GROUND BUS ASSEMBLY (Top of Bay). The Internal Ground Bus Assembly is equipped with a 2000 Amp Ground Bus Assembly. The Ground Bus Assembly has four (4) copper bus bars as follows: 1. "A" BUS BAR consists of the following: a. Five (5) sets of lug mounting holes (3/8" on 1.0" centers) to accommodate ten (10) incoming cables "back" to "back" of 500 MCM cable. b. Eleven (11) sets of holes (1/4" on 5/8" centers) to provide distribution for 22 loads "back to back". 2. "B", "C", "D" BUS BARS consists of the following: Twenty-five (25) sets of holes (1/4" on 5/8" centers) to provide distribution for 50 loads "back to back". 3. BOTTOM FEED BUS BAR (Optional) consists of the following: Three (3) sets of lug mounting holes (3/8" on 1.0" centers) to accommodate six (6) incoming cables "back to back" of 500 MCM cable. Page 10 Issue 32, March 2010

1.5 CIRCUIT BREAKER PANEL The Circuit Breaker Panel is equipped with a common bus bar rated at 500 Amps. This common bus bar extends to the side and rear of the bay where the input "Battery" leads are terminated. Two (2) sets of lug mounting holes (3/8" on 1.0" centers) provided. The Circuit Breaker Panel has 24 positions (side by side) for 0-100 Amp Circuit Breakers to be mounted as follows: A. (24) 0-50 Amps Circuit Breakers (mounted side by side). B. (12) 60, 75, and 100 Amp Circuit Breakers (mounted every other position). NOTE: Circuit Breakers are equipped as noted on J-4385068P. 1.6 DISTRIBUTION FUSE PANEL The Distribution Fuse Panel is equipped with a copper bus bar rated at 500 Amps (Similar to Section 1.5 above). The Distribution Fuse Panel has seventeen (17) positions to mount fuse holders. Fuses are equipped as noted on J-4385068P. NOTE: Number of fuses and fuse holders depends on type of fuse and width of panel. 1.7 ENVIRONMENTAL RATINGS A. OPERATING AMBIENT TEMPERATURE RANGE: 0ΕC to 50ΕC (+32ΕF to +122ΕF) B. STORAGE TEMPERATURE RANGE: -40ΕC to +85ΕC (-40ΕF to +185ΕF) C. ALTITUDE: Sea Level to 4800 ft: 0ΕC to +50ΕC (+32ΕF to +122ΕF) 4800 ft to 7000 ft: 0ΕC to +45ΕC (+32ΕF to +113ΕF) 7000 ft to 10,000 ft: 0ΕC to +40ΕC (+32ΕF to +104ΕF) D. HUMIDITY: This system is capable of operating in an ambient relative humidity range of 0 to 95%, non-condensing. E. SHOCK: This equipment, in its shipping container, withstands shock developed when one edge of the container is dropped six (6) inches while the opposite edge is resting on the ground, or is dropped two (2) inches on any surface without physical damage or degradation of the electrical performance. F. VIBRATION: This equipment, in its shipping container, withstands vibration encountered in shipping without physical damage or degradation of the electrical performance. G. VENTILATION REQUIREMENTS: For continuous operation, the system ventilating openings should not be blocked and the ambient temperature of the air entering the units should not exceed 50ΕC. Issue 32, March 2010 Page 11

- This page intentionally left blank - Page 12 Issue 32, March 2010

SECTION 2: DIMENSIONS The PEC 5068 BDFB bay is available in the following configurations: PECO II, Inc. PEC 5068 BDFB Manual Height: Width: Depth: Mounting: Height: Width: Depth: Mounting: Height: Width: Depth: Mounting: Height: Width: Depth: Mounting: LIST 2 LIST 5 LIST 8 7'-0" 9'-0" 11'-6" 30" 30" 30" 16" 16" 16" 19" 19" 19" LIST 1 LIST 4 LIST 7 7'-0" 9'-0" 11'-6" 30" 30" 30" 12" 12" 12" 19" 19" 19" LIST 3 LIST 6 LIST 9 7'-0" 9'-0" 11'-6" 34" 34" 34" 16" 16" 16" 23" 23" 23" LIST 130 LIST 131 LIST 132 7'-0" 9'-0" 11'-6" 40" 40" 40" 16" 16" 16" 23" 23" 23" The basic bays listed above comes equipped with Fuse Alarm Panel, Digital Meter & Alarm Panel, rear covers, and mounting hardware. NOTE: See Drawing J-4385068P for details. Issue 32, March 2010 Page 13

- This page intentionally left blank - Page 14 Issue 32, March 2010

SECTION 3: INSTALLERS CONNECTIONS 3.1 GROUND BUS BAR (TOP FEED) In-coming ground cables from the power plant connect to the first (5) two-hole positions on "A" load ground bus bar. 3.2 GROUND BUS BAR (BOTTOM FEED) In-coming ground cables from the power plant connect to the first (3) two-hole positions of the bottom feed ground Bus Bar. 3.3 BATTERY BUS BARS (A, B, C, & D) In-coming Battery Cables from the power plant connect to their associated battery bus bars near the rear of the bay. 3.4 GROUND BUS BAR & BATTERY (Distribution) Distribution connections made from the Circuit Breaker or fuse panel and the ground bus bar assemblies are typical for the different bays. Issue 32, March 2010 Page 15

- This page intentionally left blank - Page 16 Issue 32, March 2010

SECTION 4: INSTALLERS CONNECTIONS CAUTION: It is essential to read and understand all warnings, cautions, and notes before any connections are made to the unit or system. If further assistance is needed, contact PECO II, Inc. Field Service at the number located in the front of this manual. 4.1 INSTALLERS INFORMATION NOTES A. LOAD CENTER INPUT BUS Bus Bar Capacity Terminal Type Wire Size Fuse Size 500 Amp (2) sets of holes for 3/8" Hdwe on 1" centers. As req'd As req'd B. INTERNAL GND RETURN BUS (COMMON) Bus Bar Capacity Terminal Type Wire Size 1300 Amp (5) sets of holes for 3/8" Hdwe on 1" centers. As req'd C. CIRCUIT BREAKER OUTPUT Terminal Capacity Terminal Type Wire Size 2 Ga. Crimp Lugs As req'd TPS FUSE OUTPUT Terminal Capacity Terminal Type Wire Size 2 Ga. Crimp Lugs As req'd D. GROUND RETURN BUS Terminal Capacity Terminal Type Wire Size 2 Ga. Crimp Lugs As req'd E. ALARMS Terminal Capacity Terminal Type Wire Size 22 to 12 Ga. Pressure Strip As req'd F. FRAME GROUND (Top of Box Frame) Terminal Capacity Terminal Type Wire Size As req'd Hole 2 Lug ¼" x 5/8", Ctrs. 6 Ga. Min. G. The symbol Ø indicates Installer wiring. H. Wire sizes are based on voltage drop considerations and National Electric Code Table 310-16 for copper wire. I. Frame or Chassis Ground WIRE size based on recommendations of National Electric code Table 250-95. J. Load circuit breakers and/or fuses should not be loaded to more than 80% of their ampere rating. K. Installation of the power plant should be in areas accessible only to qualified personnel. L. All units should be secured to the building structure before operating. Issue 32, March 2010 Page 17

- This page intentionally left blank - Page 18 Issue 32, March 2010

Attachments Issue 32, March 2010 Page 19

- This page intentionally left blank - Page 20 Issue 32, March 2010