MATRIS REPORT VOLVO CONSTRUCTION EQUIPMENT 11/20/ Volvo Remarketing. arnold. arnold. Building. Administrator

Similar documents
Subject Underhood G System Error Codes and Symptoms System or Parts affected

Understanding the Modern Automotive Air Conditioning System. Trainer: Grant Hand

Section 4.2. Machine Operation - Operator s Machine Controls. Engine Throttle Control Hydraulic Motor Shift Switch (630)

GCU-10. Automatic Engine Control Unit Operators Manual

Cat Electronic Technician 2017A v1.0 Product Status Report 7/10/2017 9:49 AM

1 The speedometer displays the speed of machine in mph and km/h Emergency warning lamp Right turning pilot lamp Hyd oil temp gauge Fuel gauge

AshSPEC Dual Fuel pump control module Installation & users manual

Application Engineering Europe

messages displayed with extended idle operation

messages displayed with extended idle operation

Public Works Idling Policy Example

MaxxForce DT, 9, 10 ( )

7,15 436, Bore , ,12 Compression ratio 18 Wet weight. Engine incl. cooling system and air filtration system

7,15 436, Bore , ,12 Compression ratio. 17 Wet weight

7,15 436, Bore , ,12 Compression ratio. 18 Wet weight

VALEO HEVAC (P38 NRR) - System Overview

GTWY515, GTWY516* Fast Idle, Shift Interlock, I/O Ford Transit Introduction

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

3.6 Air Conditioning (A/C) Contents

ROAD KING TECHNOLOGIES T.: F.:

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

3.5 Air Conditioning (A/C) Contents

144 5, ,50 Compression ratio 16,5:1 Dry weight. Engine only, excluding cooling system GenPac. Engine only, excluding cooling system GenPac

12,78 779, Bore , ,22 Compression ratio. 18,1:1 Wet weight. Engine incl. cooling system, air filtration system, and frame

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Model H30 Operation Manual

International A26 (2017)

4,76 290,7 Firing order Bore

TSB #: 53 Date: 2/11/2011 HOLDEN (DELPHI) VARIABLE STROKE COMPRESSOR DIAGNOSIS STEP ACTION RESULT YES NO

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

An ISO 9001:2008 Registered Company

Release Notes. Release Notes Contents. Overview. New Vehicle Coverage - Summary: Version

DESCRIPTION AND OPERATION

Release Notes. Release Notes Contents. Overview. New Vehicle Coverage - Summary: Version

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Technical data TAD1353GE

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Technical data TAD1352GE

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

Engine incl. cooling system and air filtration system Engine incl. cooling system, air filtration system, and frame. Standby Power

EXTERNAL CONTROL VALVE (ECV) EQUIPPED VARIABLE A/C COMPRESSOR DIAGNOSIS PROCEDURE

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

General In-line four stroke diesel engine with direct injection. Rotation direction, counterclockwise viewed towards flywheel

ADESCO.LLC January 21, 2011

Technical data TAD1641VE

Stay in power. Battery consumption awareness

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/2013 2:35 PM

Maintenance Guidelines

Release Notes. Release Notes Contents. Overview. New Vehicle Coverage - Summary: Version

Installation Manual By Firstech LLC, Version: 1.1

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

Technical data TAD1641GE

6 Displacement, total Compression ratio 16,5:1 Dry weight. Engine only, excluding cooling system GenPac

TAD1661VE

Caterpillar Electronic Technician 2012A v1.0 Product Status Report 9/23/ :33 AM

Technical data TAD1642GE

MaxxForce 11 and 13 ( )

PEC017 7/20/2017. Programming Guide EPA 2017

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

ROW PRO DOWN PRESSURE

4.2 Component Identification

Technical data TWD1643GE

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

GENERAC GUARDIAN SERIES STANDBY GENERATORS

12V PROGRAMMABLE POWER OUT

User Guide 1 WAY FM MANUAL TRANSMISSION REMOTE STARTER. Table of Contents. Introduction

TriPac e. Electric Auxiliary Idle Reduction and Temperature Management System

3.10 Air Conditioning (A/C) Contents

Operator s Manual. TriPac EVOLUTION Diesel Particulate Filter (DPF) TK OP (Rev. 2, 03/16)

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

GTWY505 Fast Idle, Shift Interlock, I/O Ford E-Series

Using the Gratec Gasoline software

New Zealand Transport Outlook. VKT/Vehicle Numbers Model. November 2017

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Section 4.3. Machine Operation - Operating Procedures. Before Starting the Engine: General Pre-Start Inspection

PCT-3001 plus. Display LCD

SECTION 8 TROUBLESHOOTING GUIDE

Diagnostic Trouble Code (DTC) List

Installation Manual By Firstech LLC, Version: 1.1

ISC, QSC8.3, and ISL (FIS )

Cat Electronic Technician 2016C v1.0 Product Status Report 3/6/ :16 AM

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

Application Engineering

HGM9510 GENSET PARALLEL (WITH GENSET) UNIT USER MANUAL

Service/Inspection Checklist and Report

Caterpillar Electronic Technician 2012C v1.0 Product Status Report 11/23/2013 2:25 PM

SW20 Coolant System Maintenance.

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

ProECU Mazda MX-5. Live Data Guide 2005-onward Model Year. v1.06

General In-line four stroke diesel engine with direct injection. Rotation direction, anti-clockwise viewed towards flywheel

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

POWER SUPPLY aps-412_en 06/16

messages displayed with extended idle operation

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

L (LU4, LJ3, L88) used in Saab 9-5 ENGINE DIAGNOSTIC PARAMETERS

Idle Free Systems, Inc. Reference Guide System Component Information

Transcription:

VOLVO CONSTRUCTION EQUIPMENT MATRIS REPORT Machine model EC380D 210382 Company name Volvo Remarketing Contact name arnold Site Dealer arnold Technician Administrator Workorder Report Issuer Primary Application Building Ground Condition MATRIS Reading, Summary / Recommendation 1

EC380D 210382 Main equipment Type Equipment Track chain Hydraulic Fluid X1 Piping X3 piping Main Attachment Attachment Interface Hose Rupture Valve on Boom Hose Rupture Valve on Arm X1 return filter 2

Definition: This diagram shows the fuel consumption distribution rate on each work mode. Distribution of each work mode is shown on top of its column in rate Explanation: Y-axis: The rate of the fuel consumption on each work mode. X-axis: The work mode (10 steps in total) Distribution of each work mode is shown on top of its column in rate Average fuel consumption per hour is listed below the diagram 3

Definition: The graph shows the distribution of the operating time for the machine. The operating time is defined as the time with engine on Blue sector = Engine is running, but attachments and tracks are not moved or operated. Green sector = Machine in work with the move of attachments and tracks 4

Definition: The diagram describes the amount of fuel consumed per engine speed mode distribution. Total amount of fuel consumed (m3) in above means that the sum of the fuel while it consumed for engine ON. The values above distribution were calculated from theoretical calculation with logged data in V-ECU so it can be some different from actual performance in field. 5

Definition: The diagram describes Hydraulic Cooling fan speed control, Current (ma) distribution, on fan speed Control.. Total time (hours) in above means the sum of the time for Hydraulic Cooling fan operation. 6

Definition: The diagram describes Hydraulic Cooling fan speed control, Current (ma) distribution, on fan speed Control.. Total time (hours) in above means the sum of the time for Hydraulic Cooling fan operation. 7

Definition: The diagram describes Engine boost air temperature distribution of the machine when the engine is on. 8

Definition: This diagram shows the distribution of the engine work mode in time percent. Distribution of each work mode is shown on top of the column in percentage. Explanation: Y-axis: The percentage of the operating hours on each work mode. X-axis: The engine work mode (10 step in total) Distribution of each work mode is shown on top of the column in percentage. The sum of time distribution in percentage is 100 9

Total time (h) is listed below the diagram 10

Definition: The graph describes the engine speed distribution, in hours. The sum of all bars = total time of engine running. Explanation: Y-axis: Engine running time in hours. X-axis: Engine speed in rpm. Green bars = Normal engine speed range. Red bars =The engine speed has exceeded the maximum design speed. Exceeding the maximum design speed may cause severe damage to the engine. 11

Definition: The graph describes the engine speed distribution in percent of time. The sum of all bars=100% of engine running time. Explanation: Y-axis: Engine running time in percent. X-axis: Engine speed in rpm. Green bars = Normal engine speed range Blue bar = Idling interval. Red bars =The engine speed has exceeded the maximum design speed. 12

Exceeding the maximum design speed may cause severe damage to the engine 13

This graph shows the distribution of the engine load. Blue bar: Low load Green bar: Normal load Yellow ba r: Excessive load Load distribution for each bar is shown on top of its column in percentage. The sum of bars is 100%. 14

Definition: The graph describes the average number of engine starts per engine running hour. Explanation: X-axis: Number of average starts per hour. The actual time used for calculation, is time with engine on If the fuel consumption is high one reason may be that the engine is not turned off often enough, perhaps machine is left idling for long periods. Check " Machine utilization". The value can vary a lot depending on in which application the machine is used. To see at which different temperatures engine is started see" Start at different engine temperatures." 15

Green bar = Number of average starts per hour 16

Definition: This graph shows the distribution of delayed time at low idle speed until the engine is turned off. The delayed time distribution for each bar is shown on top of its column in percentage. The sum of bars is 100%. 17

Definition: The diagram shows the number of stops at high idle (I1 ~ P mode). Green bars = Normal engine stop Red bars = Abnormal engine stop Engine stops at a high idle can cause server damage to the turbo charger due to shortage of the oil lubrication. The engine should be stopped at low idle(i2 mode). Explanation: Y-axle: Number of engine stop at each work mode. X-axle: Work mode. 18

Distribution of each work mode is shown on top of its column in number. Total number of shut down is listed below the diagram. 19

Definition: The graph shows the distribution of engine coolant temperature, at the starting moment. Explanation: Y-axis: Number of engine starts X-axis: Engine coolant temperature. A great proportion of engine wear is due to cold starts. Try to avoid extremely cold starts. Try using an electric coolant heater. Under the graph the total number of engine starts is displayed. Also see " Number of starts / hour" to get a complete picture of engine starting. 20

21

Low coolant level Total number of occurences = 115 Op hours Year Month Day Hour Minute Duration (sec) * 0 2017 2 8 8 4 104 * 7568 2017 1 20 8 41 245 * 7568 2017 1 20 8 38 105 * 7568 2017 1 20 8 35 16 * 7568 2017 1 20 8 48 8824 * 7570 2017 1 20 11 25 307 * 7570 2017 1 20 11 21 124 * 7570 2017 1 20 11 32 107 * 7571 2017 1 20 11 42 4186 * 7571 2017 1 20 11 40 61 * 7571 2017 1 20 11 36 76 * 7642 2017 2 8 8 24 16 * 7642 2017 2 8 8 20 16 * 7644 2017 2 13 9 52 191 * 7644 2017 2 13 9 57 241 * 7646 2017 2 13 15 47 3774 * 7647 2017 2 13 16 59 1359 * 7648 2017 2 14 7 35 92 * 7648 2017 2 14 7 40 1405 * 7649 2017 2 14 8 35 16 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 22

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Criteria : In order for an occurrence of low engine coolant level to be recorded in a data point, the count to increment by 1 the engine coolant level state must change from normal to low. 23

Low engine oil level at start Total number of occurences = 0 Op hours Year Month Day Hour Minute * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 * 0 2000 0 0 0 0 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 24

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Criteria : In order for an occurrence of low engine oil level to be recorded in a data point and the count to increment by 1, an Alarm shall have been received at start up of machine 25

Low Engine Oil Pressure Total number of occurences = 12 Op hours Year Month Day Hour Minute Duration (sec) Extreme (bar) T R Q P O N M S A 6200 2016 2 13 10 2 8 2 E 6200 2016 2 13 12 13 59 2 D 6200 2016 2 13 11 11 9 2 C 6200 2016 2 13 11 2 19 2 B 6200 2016 2 13 10 42 9 2 F 6951 2016 8 31 7 51 7 2 G 7057 2016 9 22 9 5 9 2 H 7305 2016 11 2 9 41 9 2 I 7331 2016 11 6 8 19 29 0 J 7346 2016 11 10 8 44 8 2 K 7347 2016 11 10 11 37 9 2 L 7347 2016 11 10 11 41 26 1 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating hours is displayed in the first column, followed by year, month, day, hour 26

and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Extreme value : The extreme value column displays the most extreme value during the event. Criteria : In order for an occurrence of low engine oil pressure to be recorded in a data point and the count to increment by 1, the engine oil pressure state must change from normal or error to low. The event of low transmission oil pressure will end when the status changes from low back to normal or error. 27

Low Air filter pressure Total number of occurences = 21 Op hours Year Month Day Hour Minute Duration (sec) 6328 2016 3 8 4 19 1213908 6349 2016 3 25 9 59 4527 6355 2016 3 25 18 42 2610 6357 2016 3 26 9 22 9617 6360 2016 3 26 12 9 587 6361 2016 3 26 14 6 11753 6365 2016 3 26 17 32 5094 6367 2016 3 27 9 1 10953 6370 2016 3 27 12 8 3795 6373 2016 3 30 9 12 8096 6377 2016 3 30 14 18 10091 6380 2016 3 30 17 27 3863 6396 2016 4 3 9 31 6980 6510 2016 4 28 11 26 83 6511 2016 4 28 12 14 2649 6515 2016 4 28 17 29 2742 6523 2016 4 29 15 9 3626 6525 2016 4 30 8 8 6175 6703 2016 6 25 14 39 5769 6728 2016 7 1 16 21 3935 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 28

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed. Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Criteria : The criteria to get an registration, is that the alarm signal for air filter clogged is active, and that the diesel engine is running. 29

High Charge air temperature Total number of occurences = 2 Op hours Year Month Day Hour Minute Duration (sec) Extreme ( C) 6115 2016 1 22 10 58 8941 47 7929 2017 4 8 15 6 1928 103 16384 2000 0 5 0 196-2147483495 0 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 30

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Extreme value : The extreme value column displays the most extreme value during the event. Criteria : In order for an occurrence of high engine charge air temperature to be recorded and the count to increment by 1, the engine charge air temperature must change from normal to high. The event of high engine charge air temperature will end when the status changes from high back to normal. 31

Definition: The diagram describes auto-manual mode sele ction distribution of HVAC system in machine while it Works. The share of each mode compared to Total time of HVAC operation is displayed. 32

Definition: The diagram describes air temperature setting distribution for HVAC auto control mode established by operator in Cabin 33

Definition: The diagram describes ambient temperature distribution of the machine while machine operates. 34

Definition: The graph shows the total time of AC compressor engagement. Explanation: Green bar: Total time in hours, AC compressor has been engaged. Under the graph the total engine running time (in hours) is displayed. Total number of AC compressor activations is also displayed. 35

36

Definition: The diagram describes air flow direction distribution for HVAC manual control mode established by operator in Cabin. 37

Definition: The diagram describes air blower motor speed distribution for HVAC manual control mode established by operator in Cabin. 38

AC High Pressure Total number of occurences = 0 Op hours Year Month Day Hour Minute Duration (sec) Extreme ( C) Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 39

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Extreme value : The extreme value column displays the most extreme value during the event. Criteria : Logging is performed when, High AC Pressure signal is active. Ambient temp is viewed. 40

AC Boiling Protection Number of engagements = 0 Op hours Year Month Day Hour Minute Duration (sec) Extreme ( C) Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 41

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Extreme value : The extreme value column displays the most extreme value during the event. Criteria : Logging is performed when, Boiling protection signal is active. Ambient temp is viewed. 42

AC System Cut Out Pressure Total number of occurences = 71 Op hours Year Month Day Hour Minute Duration (sec) Extreme ( C) 3267 2014 7 27 16 36 12 48 3269 2014 7 27 17 52 8 46 3498 2014 9 8 16 57 10 38 3498 2014 9 8 16 42 0 47 3555 2014 9 17 15 36 11 42 3556 2014 9 17 16 13 3 36 3556 2014 9 17 15 48 3 39 5037 2015 7 15 8 39 2 32 5037 2015 7 15 8 33 3 33 5037 2015 7 15 8 35 1 33 5468 2015 9 25 17 27 3 46 5477 2015 9 26 17 48 1 48 5569 2015 10 14 17 6 3 48 5577 2015 10 15 16 3 0 44 5655 2015 10 29 14 12 3 37 5656 2015 10 29 15 27 3 31 5906 2015 12 7 12 32 3 26 5972 2015 12 17 16 21 3 39 6758 2016 7 9 10 25 3 30 6758 2016 7 9 10 6 2 29 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 43

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Extreme value : The extreme value column displays the most extreme value during the event. Criteria : Logging is performed when, AC cut out pressure signal is active. Ambient temp is viewed. 44

Definition: The graph shows the time distribution of the temperature, while engine running. Explanation: Y-axis: Time X-axis: Temperature distribution in classes. Blue bar = Warm-up phase. During the engine warm-up phase, this temperature region is passed. It is normal to have registrations in this region. Green bar = Normal working temperature. The Major part of the registrations shall be in this 45

region. Yellow bar = High working temperature. It is normal to have some registrations in this region. Red bar = Alarm. Registrations in this region is not normal, running in this region may cause severe damage. 46

Definition: The graph shows the time distribution of the temperature, while engine running. Explanation: Y-axis: Time X-axis: Temperature distribution in classes. Blue bar = Warm-up phase. During the engine warm-up phase, this temperature region is passed. It is normal to have registrations in this region. Green bar = Normal working temperature. The Major part of the registrations shall be in this 47

region. Yellow bar = High working temperature. It is normal to have some registrations in this region. Red bar = Alarm. Registrations in this region is not normal, running in this region may cause severe damage. 48

Definition: The graph describes the operating hours (%) for hydraulic hammer/shears on each engine control mode. Recommended to use green column mode of the hammer operation. I2 = Idle 2 I1 = Idle 1 F3= Fine control 3 F2= Fine control 2 F1= Fine control 1 49

G3 = General 3 G2 = General 2 G1 = General 1 H = Heavy Duty P = Power max 50

Definition: T he diagram describes Power boosted operating time distribution, when main relief pressure increases on working operation modes. In this diagram, the sum of time (%) of each working operation mode can exceed 100%. It means that customer has been operated several working operations at the same time. Total operating time with power boosted (hours) in above means sum of the time for Hydraulic Power boosted operation. The base for the percentage calculation is Total operating time with power boost. Time(%) on each working operation mode except travel and F mode above is the time, after the operator press power boost button on the joystick and until main relief pressure is recovered to default pressure. 51

Definition: This graph shows operating hour distributions on each travel speed for total travel time. Blue sector: Travel switch in low position Green sector: Travel switch in high position Explanation: Distribution of each travel time is shown on right of its sector in percentage The sum of travel time in percentage is 100 Total travel time is listed below the diagram 52

High hydraulic oil temperature Total number of occurences = 23 Op hours Year Month Day Hour Minute Duration (sec) Extreme ( C) 3346 2014 8 8 19 31 426 104 3346 2014 8 8 19 43 33 103 3346 2014 8 8 19 51 211 104 3346 2014 8 8 20 1 6 103 3347 2014 8 8 20 35 17 103 3347 2014 8 8 20 26 293 104 3347 2014 8 8 20 33 16 103 3352 2014 8 9 14 32 60 103 3353 2014 8 9 15 22 236 104 3353 2014 8 9 15 19 80 104 3353 2014 8 9 14 41 14 103 3353 2014 8 9 14 50 88 103 3353 2014 8 9 14 53 899 107 3353 2014 8 9 15 14 52 103 6719 2016 6 30 16 48 15 103 6728 2016 7 1 17 3 1436 105 6728 2016 7 1 16 33 205 103 6739 2016 7 2 17 7 620 104 6739 2016 7 2 17 4 12 103 6745 2016 7 3 15 57 146 103 Definition : This type of table shows the latest occasions when a specific event has occurred. When a specified criteria is fulfilled a registration is made. Each table row corresponds to one occasion. Operating 53

hours is displayed in the first column, followed by year, month, day, hour and minute to show when an event has occurred. The rows are not ordered chronological (The latest event may be in the middle). Only one event per minute is registered. Over the table the total number of events is displayed Duration : The duration of each event is shown after the timestamp of the event. The duration is counted as long as the criteria is fulfilled. Extreme value : The extreme value column displays the most extreme value during the event. Criteria : Logging is performed when, Alarm high hydraulic oil temperature, is active. 54

Definition: The diagram describes the distribution of pump power control current operation on each engine mode. 55

Definition: The diagram describes the distribution of Rotator operating hours on mode. 56

Definition: The diagram describes X1 hydraulic oil flow control distribution of the machine while machine operates. 57