Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Similar documents
Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

EM DC Multi-Function DC Energy Meter

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Surface mounting, flush mounting, and DIN track mounting

premier product range

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

SD Series Non-Fused Load Switches

RVS-DN Digital Reduced Voltage Motor Starter

MCD 200 Series Soft Starters

Industrial Power Supplies

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Electronic timers CT-E range Selection and ordering details

DGC-2020 DIGITAL GENSET CONTROLLER

Technical Data Sheets

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

SonoMeter 30 Energy Meters

DIN Panel Meters Long Scale

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Technical Data Sheet Sigma Series DS Meter

SonoMeter 30 Energy Meters

Safety technique. Emergency Stop Module BH 5928, BI 5928

Technical Data Sheets

Technical Data Sheets

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

Technical Data Sheets

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Transfer switch OTEC open or delayed transition

EG1299. Variable Speed Engine Controller for Telecom Backup Gensets SEDEMAC EG1299 HIGHLIGHTS

AC/DC Converter MBP250-2A13D13M

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Electronic timers CT-S range Function diagrams

1 potential-free change-over contact (max. 24 V DC/1 A) for SIL collective failure signal SIL functions - safety functions Standard: Safe ESD

Technical Data Sheets

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

Micro Controller based Motor Protection Relay & Motor Management System

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Digital Time Switches

USERS MANUAL MCD REMOTE OPERATOR

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CP Automatic capacitor bank

Scheda prodotto Relè Series E

Low voltage AC drives

AuCom - Soft Starters

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

CTi Automation - Phone: Fax: Web:

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Cat N 3. OVERALL DIMENSIONS

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

RVS-DX Digital Reduced Voltage Motor Starter

D509E. Manual Motor - Starters

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

MIT515, MIT525, MIT1025, MIT1525

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

3 Uninterruptible Power Systems

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Acuvim-L Series. Multifunction Power Meter. Max & Min

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Technical Data Sheet Sigma Series DG Meter

VSD Series II Variable Speed Micro Drives

3 Uninterruptible Power Systems

Safety design conforming to the following provisions

DPX Electronic + earth leakage

OPERATING INSTRUCTIONS ECON-M

Safety Control HR1S-AC. Safety Relay HR1S-AC

Sorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes

Product discontinuation. Notices. Measuring / Motor Protective Relays. Discontinuation Notice of Single-phase Voltage Relay K8AB-VW[].

MagFlux Q 8200 Series

Magnetic Overcurrent Circuit Breaker

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

IMMOBILISER SYSTEM INTRODUCTION

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

EPS/ELA-Series User Manual EPS/ELA 250W

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Emergency lighting units PC COMBO

Transcription:

Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target system Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis Page 1 of 6

Block Diagram: Timekeeper for time stamping of values Display 4 line 8 digits LED display Applications: Solar Photovoltaic Systems Battery chargers and systems Wind Power Generation Measurement Inputs 1 channel Voltage Relay Outputs 4 RO Electroplating Industries Power Distribution for Telecommunication Industrial DC control Systems Modbus-RTU Measurement Inputs 4 channel Current Standard Optional Power Supply 60-300 V AC/DC USB-based Serial Port Possible applications of Relay Outputs: Alarming via lamp or horn Load shedding Remote controlling Product Features: Multi-Channel Support: Single meter measures energy consumption of four independent loads connected to one Voltage source Bi-Directional Voltage & Current measurement: The meter has a unique feature of measuring both charging and discharging current Event Logging: Previous 5 Events of factory-default parameters can be logged with Date and Time stamp Data Logging: User Selectable parameters (1 to 30) can be logged at regular intervals (1 to 60 min) with Date & Time stamp in internal memory and can be accessed via Modbus Max Records can vary from 8532 to 91010 depending upon number of selected parameters Load Pro le Analysis: Logging of Energy consumed and Peak Demand (Power & Current) in a day and in a month for ef cient tracking of load behaviour Daily Data is available for last 1 year and Monthly Data is available for last 14 years Direct Remote Access (optional): Remote con guration of the Instrument and access of measured parameters via MODBUS Programmable baud rates up to 57.6kbps Parameter Screen recall: In case of power failure, the instrument memorizes the last displayed screen 4 - line 8 digit Ultra-bright LED Display: 4 - line LED display provides easily readable data on meter front with a display range of 99999999 Reverse Locking: Energy and Ampere Hour accumulation can be blocked for Reverse Power and Current resp. Reverse condition can be set as Import or Export Onsite Con guration: Con guration can be done via Front Keys, USB-based Serial Interface or RS485 (MODBUS) Relay Functions: Limit Switch - For protection against over-shoot or under-shoot of any selected parameter Pulse Output - To drive an external counter for energy measurement Timer - Cyclic ON-OFF operation of relay for user-de ned cycles with programmable ON-OFF Delays Remote Operation - Relays can be activated remotely via Modbus Reverse Locking Alarm RTC Relay - Relay can be activated & deactivated at prede ned ON & OFF Time on any or all Days of Week Enclosure Protection for dust and water: Conforms to IP 54 (front face) as per IEC60529 Compliance to International Safety standards: Compliance to International Safety standard IEC 61010-1 - 2010 EMC Compatibility: Compliance to International standard IEC 61326-2012 Page 2 of 6

96mm 92mm+0.8 RISH EM DC Dimensions Details: 96 mm Display Area Front View 3.15 80mm Side View 92mm+0.8 Panel Cutout Technical Speci cations: Input Voltage: Nominal Input Voltage Range Max continuous input voltage Input Current: No of Channels 4 Current Sensor Shunt Setting Range Full Scale Setting Range Max continuous input current Operating Measuring Range: Voltage Current Auxiliary Supply: Higher Aux Nominal Value VA Burden: Nominal input voltage burden Nominal input current burden Auxiliary Supply burden Accuracy: Relay Output: Max Load Voltage Max Load Current 10 ~ 60 VDC 61 ~ 200 VDC 201 ~ 1000 VDC 125% of nominal value External Shunt 1 A to 20 ka 125% of nominal value 60 V 300 V AC-DC, 45 to 65 Hz range < 0.4 W approx. < 0.1 W approx. per channel < 6 VA approx Reference Conditions 23 C +/- 2 C Voltage ±0.5% of Nominal value (±5 to ±120%) Current ±0.5% of Nominal value (±5 to ±120%) Power ±0.5% of Nominal value (±5 to ±120%) Energy Class 1 Temperature Drift Display: Type Display Height Overload Indication Display Range: 50 ~ 150 mv 0.05%/ C 4 line 8-digit LED Display 9 mm Voltage 0 to ±9999 Current 0 to ±9999 Power 0 to ±9999 Energy (Import & Export) 0 to 99999999 Real Time Clock (RTC): Uncertainty ±2 to ±125% of nominal value ±0.2 to ±125% of nominal value 230 V AC-DC, 50/60 Hz for AC Aux -ol- (Above 126% of nominal value) 250 VAC / 30 VDC 5 A ±2 minutes / month (23 C +/- 2 C) NOTE: Variation due to influence Quantity is 100% of class index Page 3 of 6

Installation: Meter PANEL LOAD 1 LOAD 2 LOAD 3 LOAD 4 SLIDE IN THIS DIRECTION AND LOCK Electrical Connection: Vdc- Shunt Vdc+ 2 5 8 11 1 3 4 6 7 9 V+ V- I1+ I1- I2+ I2- I3+ I3- I4+ I4- Aux Supply 13 14 L N Technical Speci cations: Optional RS485 Communication: Protocol Baud rate Distance Overload Withstand: Voltage Current Applicable Standards: Modbus-RTU 4800, 9600, 19200, 38400, 57600 bps 1200 m EMC IEC 61326-2012 Immunity Safety IP for water & dust IEC 60529 (IP 54) Pollution degree 2 Installation category Protective Class 2 High Voltage Test (AC 50Hz, 1 minute) Environmental: Operating temperature Storage temperature Relative humidity Warm up time Shock Vibration Number of Sweep Cycles Dimensions & Weights : 2 x rated value for 1 second, repeated 10 times at 10 second intervals 20x rated value for 1 second, repeated 5 times at 5 min intervals IEC 61000-4-3. 10V/m min Level 3 industrial Low level IEC 61010-1-2010, Permanently connected use 1000V CATII, 600V CATIII (Measuring Inputs) 4.4 kv AC, Enclosure versus all electrical circuits -10 to +55 C -20 to +70 C 0... 90% non condensing Minimum 3 minute 15g in 3 planes 10... 55...10 Hz, 0.15mm amplitude Bezel Size 96 mm x 96 mm DIN 43 718 Panel Cut-out Overall Depth Weight 300V CATIII (Power Supply) 3.7 kv AC, Auxiliary Supply versus all other electrical circuits 2.2 kv AC, Measuring Terminals versus all other electrical circuits 2.2 kv AC, Relay versus Relay 2.2 kv AC, USB & RS485 versus all other electrical circuits 10 per axis 92 + 0.8 mm x 92 + 0.8 mm 80 mm 620 gm. approx. It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5mm. Permissible cross section of the connections wires: <= 4.0 mm sqr. single wire or 2x2.5mm sqr. ne wire Page 4 of 6

Measured Parameters: Sr No Parameters Sr No Parameters 1 Voltage 2 Current channel 1 3 Current channel 2 4 Current channel 3 5 Current channel 4 6 Total Import & Export Power 7 Power channel 1 8 Power channel 2 9 Power channel 3 10 Power channel 4 11 Total Import & Export Energy 12 Import and Export Energy channel 1 13 Import and Export Energy channel 2 14 Import and Export Energy channel 3 15 Import and Export Energy channel 4 16 Total Import & Export Ampere Hour 17 Import and Export Ampere Hour channel 1 18 Import and Export Ampere Hour channel 2 19 Import and Export Ampere Hour channel 3 20 Import and Export Ampere Hour channel 4 21 Total Import & Export Power Demand 22 Import and Export Power Demand channel 1 23 Import and Export Power Demand channel 2 24 Import and Export Power Demand channel 3 25 Import and Export Power Demand channel 4 26 27 28 29 30 Total Import & Export Current Demand Import and Export CurrentDemand channel 1 Import and Export CurrentDemand channel 2 Import and Export CurrentDemand channel 3 Import and Export CurrentDemand channel 4 31 On Hour 32 Run Hour channel 1 33 Run Hour channel 2 34 35 Run Hour channel 3 Run Hour channel 4 36 Max and Min Voltage 37 Max and Min Current channel 1 38 Max and Min Current channel 2 39 Max and Min Current channel 3 40 Max and Min Current channel 4 41 Max Import and Export Power Demand channel 1 42 Max Import and Export Power Demand channel 2 43 Max Import and Export Power Demand channel 3 44 Max Import and Export Power Demand channel 4 45 Max Import and Export Current Demand channel 1 46 Max Import and Export Current Demand channel 2 47 Max Import and Export Current Demand channel 3 48 Max Import and Export Current Demand channel 4 49 Number of Interrruptions 50 Old Import and Export Energy channel 1 51 Old Import and Export Energy channel 2 52 Old Import and Export Energy channel 3 53 Old Import and Export Energy channel 4 54 Old Import and Export Ampere Hour channel 1 55 56 57 58 Old Import and Export Ampere Hour channel 2 Old Import and Export Ampere Hour channel 3 Old Import and Export Ampere Hour channel 4 Old Max Import and Export Power Demand channel 1 59 Old Max Import and Export Power Demand channel 2 60 Old Max Import and Export Power Demand channel 3 61 62 Old Max Import and Export Power Demand channel 4 Old Max Import and Export Current Demand channel 1 63 Old Max Import and Export Current Demand channel 2 64 Old Max Import and Export Current Demand channel 3 65 Old Max Import and Export Current Demand channel 4 66 Old On Hour 67 Old Run Hour channel 1 68 Old Run Hour channel 2 69 Old Run Hour channel 3 70 Old Run Hour channel 4 71 Old Number of Interruptions Page 5 of 6

Ordering Information: Ordering information Model Basic Model (without USB, RTC & Datalogging) Higher Model (with USB, RTC & Datalogging) Ordering Code RISH EM DC 6001 6002 Nominal Input Voltage 10-60 V 61-200 V 201-1000 V 60 200 1000 Auxiliary Supply Voltage 60-300 V AC DC HA Communication MODBUS (RS485) MODBUS Option not used C NC Output Options No Relay Output 2 Relay Outputs 4 Relay Outputs NR 2R 4R Order Code Example: RISH EM DC - 6002-60 - HA - C - 2R RISH EM DC Higher Model, Voltage Range 10-60 V, Higher external aux 60V 300V AC/DC, with MODBUS (RS485) communication, 2 relay outputs. Page 6 of 6