Z22C-** Preconfigured Network Zone System

Similar documents
Network Zone System. Part Numbers: Z22N-****** Z22R-****

Network Zone System Part Numbers: Z23N-***** Z23R-****

Universal Network Zone System Part Numbers: Z23U-****

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Opticom Rack Mount Fiber Enclosures

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Instructions for Wire Mesh Pulling Grips on Outside Plant and Indoor/Outdoor Fiber Optic Cable Best Practices

PanView iq (PViQ) Fiber Tray

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Cellwatch Electrical Installation

accqpulse Velocity Profiler Sensor Installation Guide

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

EPIC CIRCON M23 Series

Space Saving Cable Management Rack Systems

PVM 220 Installation Guide

Mini USB and USB 2.0-IP67 Connector System

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Chapter 3. Installing Equipment

PVM 220 Installation Guide

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

EPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS

Pneumatic Isolation Module

8400 Series Fiber Distribution System

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

General Specifications for Lighthouse Power Pedestal

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

INLET DUCT FOR CISCO 6880 Part Number(s) DIRLC25S23W

19 1HU Splicing and Front Patching Shelf

Fiber Splice Panel Rack Mount User Manual

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

INSTRUCTION SHEET. Installation Instructions for Mercmaster LED Luminaire. Applications. Agency Ratings. Product Safety

Operating Instructions

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

Installation Instructions for Lifeline MC Cable Splice Using Ceramic Standoffs

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

Fiber Optic Splice Module

Baying systems TS 8. Height: 1200 mm/1400 mm, depth: 500 mm

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

Company Switch Installation Instructions and User Manual

SynergEX Panelboards for Hazardous Locations

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Product Manual MNX10043 REV 0 MODEL DSB. Dual Sensor Modular Switch box

Instructions for Use - Opt-X 1000i Enclosure

Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402

INSTALLATION INSTRUCTIONS

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

Kaedra Weatherproof DIN Type Enclosures

Galaxy VM. Battery Breaker Box Installation 09/

AE012 Enclosure for E5x Series Energy Meters With Swing Panel Kit Product Overview

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

Installation Instructions: ACCENT SYSTEM

MIGHTY MO CABLE MANAGEMENT SYSTEM

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

MULTI-P URPOSE S HELTER


19 floor rack with steel door

Product Data For FARNELL

Lighting Control Unit Installation Instructions

Mid-Power Remote Unit (MRU) SISO Outdoor Enclosure Assembly Quick Installation Sheet

Mid-Power Remote Unit (MRU) Outdoor Enclosure MIMO Assembly Quick Installation Sheet

ELECTRICAL SOLUTIONS. Pan-Way Type LD2P10 Multi-Channel Surface Raceway System. Multi-Channel Fittings for LD2P10 C2.75

Space Saving Cable Management Rack Systems

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

Fiber Connector Shelf (CCS)

INSTRUCTIONS. Power Panel. Installation Instructions

EPIC CIRCON M23 Series

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FUEL SURGE TANK KIT

FIBER CONNECTOR SAFETY WARNINGS

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION INSTRUCTIONS

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

INSTALLATION INSTRUCTIONS

Desktop 5.5 Z Axis Retrofit

Lucent Technologies Whippany Physical Design

PRELIMINARY INSTALLATION INSTRUCTIONS. PARTS LIST Security System Kit (sold separately) P/N 08E51-EP4-101

The range is fully compatible with the PS system accessories.

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

INSTALLATION & OWNER S MANUAL

ANZI Transfer Switch and Generator Wiring Installation Addendum

CM52 Network Protector with Arc Flash Reduction Module

Rittal console systems...

INSTALLATION INSTRUCTIONS

Turbo-House Air Inlet Installation & Operator s Instruction Manual

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

COYOTE STP (Service Termination Point)

INSTALLATION INSTRUCTIONS

Ford 7.3L SuperDuty Cold Air Intake

Installation and Maintenance Instructions for 101B DIN-Rail Mounting Kit

INSTALLATION INSTRUCTIONS

Transcription:

Z22C-** Preconfigured Network Zone System Page 1 of 12

TABLE OF CONTENTS Overview of Products Specs / Tools Needed Safety Information / Warnings Wall Mounting Bracket Installation Wall Mounting Removable Gland Plate Reversible Door Integrated Layout Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Recommended Installation Instructions for: Cage Removal Power Entry Uplink Entry Downlink Entry Patch Cord Routing Page 11 Page 11 Page 11 Page 11 Page 12 Page 2 of 12

A B C D L K J I H G F E Integrated Network Zone System Z22C-**configurations include the following: Pictured Above A). 24" x 24" Enclosure B). Preconfigured Back Panel C). Strain Relief Bar D). Management Slack L-rings E). Gland Plate F). Ground Bar G). 21.0" Din Rail H). Accessory Side Panels I). Fiber Spool J). 17.75" Din Rail K). LC Fiber Optic Modules (6) L). Fiber Surface Mount Box Not Pictured M). Hook and Loop Ties N). Cable Tie Push Mounts O). Cable ties P). High Voltage Barrier Q). LC Fiber Patch Cords (2) R). CAT6 Copper Patch Cords (8) S). CAT6 Mini-Com Modules (8) Page 3 of 12

Enclosure Rating Installation Dimensions Weight Preconfigured Network Zone Z22C-** Specifications UL Type 4/12 and IP66 (IEC 60529), NEMA 4X available Wall mount with optional outside-mount flange Height Width Depth 24 24 11.7 (610 mm) (610 mm) (297 mm) 75 lbs. (34.0 kg) Tools and supplies needed to complete install of Preconfigured Zone System: (not included) Fiber-optic trunk cable: FSPD504 or similar LC Fiber-optic connectors: FLCDMCXAQY or similar Fiber-optic termination tools: OptiCam termination kit or similar Category 6 copper cable for downlinks: PUR6504BU-UY or similar Copper cable termination tools: wire cutters, EGJT tool Tools to cut enclosure sidewalls: Greenlee punch or similar 5/16 bolts for wall mounting of steel enclosure #6 AWG Infrastructure ground cable: RGEJ660PF or similar 3/8" bolts for wall mounting of stainless steel enclosure 3/8" socket or box wrench ground bar Rigid conduit for power and copper downlink cables Page 4 of 12

SAFETY INFORMATION DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES The practices contained herein are designed as a guide for use by persons having technical skill at their discretion and risk. Panduit does not guarantee any favorable results or assume any liability in connection with these instructions. Local, State, Federal, and Industry Codes and Regulations, as well as manufacturers requirements, must be consulted before proceeding with any project. Panduit Corp. makes no representations of nor assumes any responsibility for the accuracy or completeness set forth herein. Panduit disclaims any liability arising from any information contained herein or for the absence of same. Page 5 of 12

Wall Mounting Bracket Installation Note: The enclosure may be mounted to the wall without the mounting brackets Step 1: Turn enclosure on its side with the locks orientated Latch Tool towards the top. Using Latch Tool, turn both locks towards each other to open door. Step 2: Install Wall Mounting Brackets into back of the enclosure aligning threaded studs on brackets to holes located in back of the enclosure. Be sure obround mounting holes on the wall mounting bracket align outward. Step 3: Secure Wall Mounting brackets using sealing washers and (1) per threaded stud. Torque spec: Steel Enclosure: 5/16" washers = 30 in-lbs Stainless Steel Enclosure: 3/8" washers = 40 in-lbs Step 4: Close Door. Using Latch Tool, turn both locks to secure the door. If Mounting Flanges are not used: Step 1 For Steel Enclosure: Use 5/16" Sealing Washer (supplied) and a 5/16" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. For Stainless Steel Enclosure: Use 3/8" Sealing Washer (supplied) and a 3/8" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. Wall Mounting Brackets Step 2 Sealing Washer Hex Nut Detail View Step 3 Washer (provided) Screw (not provided) Page 6 of 12

Wall Mounting Enclosure may be mounted on any wall utilizing Unistrut or by drilling directly into any concrete wall. There are two mounting hole locations on the top flange and two locations at the bottom flange. Step 1: Drill holes 19.25"-22" apart horizontally and 26" apart vertically. Step 2: Mount the enlosure with the locks to the right and secure. If mounting flanges are not used: The holes in the wall will be 22.5" apart horizontally and 34.5" apart vertically. Hole Locations for Wall Mounting Backview for wall mounting Page 7 of 12

Panduit Corp. 2014 INSTALLATION INSTRUCTIONS Removable Gland Plate The Gland Plate, located on the bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression fittings. Remove (12) screws and (12) flat washers on the bottom of the enclosure to remove plate from the enclosure. Accommodations for incoming conduit have been supplied on the enclosure. A 1/2 conduit plug is installed in the recommended incoming power location. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. When reinstalling the gland plate, ensure the screws are tightened until the gland plate flanges make contact with the enclosure surface. Plug Gland plate Page 8 of 12

Reversible Door The enclosure comes with the door opening to the left. The door may be reversed to open to the right. Step 1: Remove pins from the door hinges. Step 2: Remove screws and door hinges Step 3: New Hole locations will have to be drilled or punched out. Reinstall hinges and screws on opposite side. Step 4: Turn door 180 degrees and mount to the opposite side of the enclosure. Insert the same pins to secure the door. STEP 1 STEP 2 STEP 3 Torque 33 in-lbs. Add silicone to bolts (6x) (not supplied) STEP 4 Page 9 of 12

Proposed Layout Stratix Din Rail Mounted Switch (Not Provided) Din Rail Mount Copper Module (One Provided) for up to 8 CAT6 Mini-Com Modules Din Rail Mount Copper Patch Box (Not Provided) Push Mounts (Provided) Electrical Circuit Breakers and Terminals (Not Provided) Industrial Switch Power Supplies (Not Provided) Panduit Uninterrupted Power Supply (Not Provided) Page 10 of 12

Remove(3) #10-32 screws Cage Removal Recommended Installation Instructions for Power Entry Remove plug in gland plate and replace with conduit fitting. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. Connect infrastructural ground to ground Power Conduit Entry Recommended Installation Instructions for Uplink Entry Recommended Installation Instructions for Downlink Entry Uplink Cable (fiber shown) spooled in the surface mount box Slack loop formed around the L-ring cable managers Uplink Cable Conduit Entry Downlink Cable Conduit Entry Page 11 of 12

Patch Cord Routing Slack tied to towel bar with hook and loop ties. (Provided) Patch cords supported by the strain relief bar and L-ring managers, routed from the switch to the patch module Fiber patch cord slack on the side mounted spool For Instructions in Local Languages and Technical Support: http://www.panduit.com/wcs/satellite?pagename=pg_wrapper&friendlyurl=/en/support/contact-us www.panduit.com Page 12 of 12 E-mail: tp-csdebt@panduit.com Fax: (800)777-3300