Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

Similar documents
Diesel Generating Set. Generator Ratings

Technical Data 1600KW / 2000KVA 1450KW / 1813KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz)

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Diesel Generating Set

FE - C KW / 650KVA 600KVA

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

Diesel Generating Set

CGT Stamford UCI 274 E1

Diesel Generating Set

Diesel Generating Set

POWERED BY DOOSAN DIESEL GENERATOR SET

Dual Frequency Diesel Genset

Prime Ratings (KW/KVA) 400/ / / /910

Weifang Ricardo Generator

DW Series Generator. Specification BV-DW145

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

SIVASA Doosan Series. SD250 Technical Data

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Diesel generator set QSK23 series engine

TPD2250H6.3 TECHNICAL DATA

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

Diesel generator set QSX15 series engine

Voltage kva kw kva kw Amp 400/ ,00 160,00 180,00 144,00 259,00

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Diesel generator set 6BT5.9 series engine

Spark-ignited generator set

Diesel generator set QSK23 series engine

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Diesel generator set QSK78 series engine

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Diesel generator set QSB7 series engine

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Spark-ignited generator set

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMS350C/S EC Series. Features:

Diesel generator set QSK50 series engine

WPS60/S EP Series. Features:

Diesel generator set QSK78 series engine

Standby kw Prime kw

Diesel generator set 4BT3.3 series engine

GE.VO.360/325.SS+0_all

Rental Power QSB7 series engine

Diesel generator set QSL9-G7 series engine

WPS150/S EP Series. Features:

WPS100/S EP Series. Features:

60 Hz FEATURES. Exclusively from your Caterpillar dealer

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Model MP150 W W

WPS20/S EP Series. Features:

Model NA 2 L

WPS350/S EP Series. Features:

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

DIESEL GENERATOR SET. 60 Hz FEATURES

Diesel generator set QST30 series engine

USP&E Cummins Series Diesel Generator Set

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

KK44 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

KM44. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel POWER

Powered by Cummins Model:YN-95C

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

K26M POWER 240 MONO 230 MONO 220 MONO

K28H GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J80UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

J200UC3 GENERAL CHARACTERISTICS POWER DIMENSIONS COMPACT VERSION DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION TERMS OF USE.

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

KM33. Frequency (Hz) Voltage (V) Standard control Panel Optional control panel Optional control Panel POWER

Transcription:

BA.A-CN60 280KW / KVA 256KW / 20KVA Standby Power(Hz) Prime Power(Hz) General Features: Engine (Cummins NTA855-G1B) Radiator 40C max, fans are driven by belt, with safety guard 24V charge alternator Alternator: single bearing alternator IP2, insulation class H/H Absorber Dry type air filter, double fuel filter, oil filter, coolant filter Main line circuit breaker Permanent Magnet Generator(PMG) Standard control panel Two12V batteries, rack and cable Ripple flex exhaust pipe, exhaust siphon, flange, muffler User manual Prime Ratings (KW/KVA) 256/20 256/20 256/20 256/20 Standby Ratings (KW/KVA) 280/ 280/ 280/ 280/ Generator Ratings Standby P.F Amps (COS ) 459 487 5 52 Phase HZ Voltage 440/254 415/240 400/20 80/220 Prime Power (PRP): Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97(eqv ISO8528); A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation. Standby Power Rating (ESP): The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating. Sales Promises Bargh afshan alborz provides a full line of brand new and high quality products. Each and every unit is strictly factory tested. Warranty is according to our standard conditions: a, 15 months, counted on the day Bargh afshan alborz sold to the first buyer; b, One year after installation; c, 1000 running hours (accumulated); subject to the earlier one. Service and parts are available from Bargh afshan alborz or distributors in your location. 1/5Specifications may change without notice

BA.A-CN60 Manufacturer / Model: Air Intake System: Fuel System: Cylinder Arrangement: Displacement: Bore and Stroke: Compression Ratio: Rated RPM: Max. Standby Power at Rated RPM: Governor Type: Exhaust Gas Flow: Exhaust Temperature: Max Back Pressure: Max Intake Restriction: Consumption: Air Flow: 100%( Prime Power) Load: Total Oil Capacity: Oil Consumption: Engine Oil Tank Capacity: Oil Pressure at Rated RPM: Total Coolant Capacity: Thermostat: Max Water Temperature: ENGINE DATA Cummins NTA855-G1B, 4-cycle Turbo,Air/air cooling PT-stc type fuel pump 6 in line 14L 140*1(mm) 14.0 10rpm 280KW/80HP Electronic Exhaust System 980L/s 458 10kPa Air Intake System 6.25kPa 755L/s 11800L/s Fuel System 69 L/h Oil System 8.6L 0.24L/h 6L 241-45kPa Cooling System 85L 82-9 104 2/5Specifications may change without notice

BA.A-CN60 ALTERNATOR SPECIFICATION GENERAL DATA Compliance with GB755, BS00, VDE0, NEMAMG1-22, IED4-1, CSA22.2 and AS159 standards. Alternator Data Number of Phase: Connecting Type: Phase and 4 Wires, Y type connecting Number of Bearing: 1 Power Factor: Protection Grade: IP2 Altitude: 1000m Exciter Type: Brushless, self-exciting Insulation Class, Temperature Rise: H/H Telephone Influence Factor (TIF): < THF: <2% Voltage Regulation, Steady State: ±1% Alternator Capacity: 60KVA Alternator Efficiencies: 9.5% Air Cooling Flow: 0.54m/s GENERATING SET DATA Voltage Regulation: ±5% Voltage Regulation, Stead State: ±1% Sudden Voltage Warp (100% Sudden Reduce): +25% Sudden Voltage Warp (Sudden Increase): -20% Voltage Stable Time (100% Sudden Reduce): 6S Voltage Stable Time (Sudden Increase) 6S Frequency Regulation, Stead State: 5% Frequency Waving: 0.5% Sudden Frequency Warp (100% Sudden Reduce): +12% Sudden Frequency Warp (Sudden Increase): -10% Frequency Recovery Time (100% Sudden Reduce): 5S Frequency Recovery Time (Sudden Increase): 5S /5Specifications may change without notice

BA.A-CN60 Options Engine Fuel System Control System Heater 2KW & 4KW Daily Fuel Tank Auto Control Panel Battery Charger.5A & 7A Base Fuel Tank Remote Control Panel Water Separator Auto Transfer Switch (ATS) Fuel Level Sensor Paralleling System Alternator Others Data Anti Condensation Heater Rainproof Type Engine Parts Drawing List Drop CT(For Paralleling) Soundproof Type Spare Parts Container Type Dimension & Weight Standard Configuration With Base Fuel Tank Soundproof Type (Open Type) Overall Size: 020(mm *1100(mm)*18(mm) Weight: 29kg Overall Size: 020(mm)*1100 (mm)*1900(mm) Weight: 1kg Overall Size: 420(mm) 1440 (mm) 2200(mm) Weight: 4000kg 4/5Specifications may change without notice

BA.A-CN60 Standard Control Panel Auto Module Control Panel Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: MRS10-can receive remote output signal from ATS and realize auto start and stop of generators. MRS16-can realize all functions of MRS10, add RS22 interface which can communicate with PC to realize remote operation. AMF25-Auto Mains Failure controller, can realize all functions of MRS16, furthermore can detect ATS and control directly. Auto Parallel Control Panel Automatic Parallel Control Panel This new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future. 5/5Specifications may change without notice