Technical Information

Similar documents
Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

FMotor Circuit Controllers

Ideal for use as a manual starter

Technical data for manual motor starters Type MS325

KT4 Manual Motor Starter

Bulletin 190-M Compact Starters. Selection Guide

D509E. Manual Motor - Starters

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

MS General Information Extended Product Type: MS

Short form catalogue. Motor protection & control

Bulletin 140M Motor Protectors

Series KTU7 UL489 Molded Case Circuit Breakers

Thermal Overload Relays - WEG RW Series, 2 Pole

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Series KTU7 UL489 Molded Case Circuit Breakers

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

KT4 Manual Motor Starters

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Application Mini Contactors for Motors and Resistive Loads

Manual Motor Starters. Meta-MEC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Protection Equipment

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Protection Equipment. 5/2 Introduction

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

3 - Protection components Motor circuit-breakers

Essential equipment for all your requirements

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Manual Motor Starters

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

FMotor Circuit Controllers & Circuit Breakers

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Bulletin 193-T1 Bimetallic Overload Relays

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Softstarter Intelligent Controllers

CI-TI Contactors and motor starters Types CI 61 - CI 98

1489-M Circuit Breakers

Bulletin 825 SMM Smart Motor Manager

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

SIRIUS 3RU2 Thermal Overload Relays

Technical Information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Technical Information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Control Circuit Protection

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Series L9 UL489 Miniature Circuit Breakers

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relay TF65 and TF96

Application Mini Contactors for Motors and Resistive Loads

Controls. CONTACTORS CWB Line (up to 40A)

Technical Information

ASL09..S 3-pole Contactors - Spring Terminals

Technical Information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Thermal overload relay TF140DU and TF140DU-V1000

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Manual motor starter MS116

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Cylindrical fuse-link

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter magnetic only MO325

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Mini contactors B6, BC6 with 3 pole

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Description. Positive safety relays

Phone: Fax: Web: -

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

CI-TI Contactors and Motor Starters Type CI 6-50

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

MINIATURE CIRCUIT BREAKER

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Motor Controllers + Circuit Breakers

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Transcription:

-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42 35 600V [ka] 42 42 18 10 Motor Load, Single-Phase 115V [HP] 2 3 5 7-1/2 200V [HP] 3 5 10 15 230V [HP] 3 7-1/2 10 20 Motor Load, Three-Phase 200V [HP] ~ ~ ~ ~ 230V [HP] 7-1/2 10 20 30 460V [HP] 15 30 40 60 575V [HP] 20 30 60 75 Maximum Rated Current of the Protective Device [A] 2000 IEC Performance Data Catalog No. -100... 25A 40A 63A 90A Switching of Three-Phase Motors AC-2, AC-3 230/240V [kw] 5.5/7.5 10/11 13/20 22/25 400/415V [kw] 7.5/12.5 15/22 25/32 37/45 500V [kw] 11/15 18.5/25 30/40 45/55 690V [kw] 15/22 25/30 37/55 63/75 Motor Load, Single-Phase gg, am, only if I cc >I cu 230/240V [A] ~ ~ ~ ~ 400/415V [A] 160 160 160 160 500V [A] 160 160 160 160 690V [A] 160 160 160 160 Ultimate Short-Circuit Breaking Capacity I cu 230/240V [ka] 100 100 100 100 400/415V [ka] 65 65 65 50 500V [ka] 50 30 30 25 690V [ka] 15 8 8 6 Rated Short-Circuit Breaking Capacity I cs 230/240V [ka] 100 100 100 100 400/415V [ka] 65 50 50 25 500V [ka] 50 25 25 13 690V [ka] 15 8 6 6 37

Series -100 Controller General Data Catalog Number -100 Rated Isolation Voltage IEC, SEV, VDE 0660 690V UL, CSA 600V Rated requency 40...60 Hz Lifespan Mechanical 30,000 operations Electrical 10,000 operations at 63 A 5,000 operations at 90 A Switching requency maximum 20 ops/hr Ambient Temperature Storage -25...+80ºC (-13...176º) Operation -25...+60ºC (-13...140º) Corrosion Resistance C IV (per IEC 68) Resistance to heat and humidity 40ºC, 92%, 56 days Resistance to cyclic heat and humidity 23ºC, 83%/40ºC, 93%, 50 cycles Type of Protection IP20 enclosed state Resistance to Shock [G] 30, 11 ms Resistance to Vibration requency range 10...150 Hz In all directions in testing Rated Thermal Current I th IEC, SEV, VDE 0660 ~ At 40ºC ambient temperature 16...90 A At 60ºC ambient temperature 4 adjustment ranges Rated current I e 16...90 A Rated Impulse Voltage/Pollution Main circuits 6 kv/3 Auxiliary circuits 6 kv/3 Overload Protection Characteristics motor protection per IEC 947 Temperature compensation -25...+60ºC (-4...140º) Phase failure protection differential release Magnetic Release Operating current fixed setting 14 x I e maximum I e maximum = maximum value of adjustment range Power Loss P v At maximum rated current and with switch at rated operating temperature 33 W IEC 947-1/2/4/5; Standards EN 60947; UL 508; CSA 22.2 Approvals CE, CSA, UL Lloyd s Register of Shipping Terminals Terminal Type lexible [mm 2 ] Stranded [mm 2 ] 2.5...35 Breakaway Torque [Nm] Stranded [mm 2 ] 4...50/12...2 Breakaway Torque [lb-in.] 6...10/55...90 Weight 3-pole circuit breaker [g] 1845 (4.10) 38

Series -100 Controller General Data Integrated Short-Circuit Indicator in Catalog Number -100-UA...and -100-AA... Rated Thermal Current I th At 40ºC ambient temperature [A] 2 At 60ºC ambient temperature [A] 2 NEMA Contact Class (UL/CSA-Approval) AC DC Make/Break max. voltage 432 VA72 VA480 A 28 VA28 VA250 V Back-Up use gl, gl [A] 16 24V 110V 230V 400V 500V AC-14 1.5A 1.5A 1.0A 1.0A 0.75A Rated Current 24V 48V 60V 110V ~ DC-13 1.5A 0.5A 0.4A 0.2A ~ Terminals Terminal Type lexible [mm 2 ]/[AWG] 0.75...2.5/No. 18...14 Stranded [mm 2 ]/[AWG] 0.75...2.5/No. 18...14 lexible [mm 2 ]/[AWG] 0.75...2.5/No. 18...14 Stranded [mm 2 ]/[AWG] 0.75...2.5/No. 18...14 Tightening Torque [N m]/[lb in] 1...1.5/8.8...10.3 Weight [g (lb)] 91 (0.21) Operating Voltage Pick-up Drop-out Duty cycle Undervoltage Trip Unit for ront Mounting on Catalog Number -100 0.85...1.1 x Us 0.7...0.35 x Us continuous Control Voltage min. 21V 50 Hz / 24V 60 Hz max. 600V 50 Hz Coil Performance Terminals Terminal Type pick-up drop-out upon inquiry lexible [mm 2 ] / [AWG] 2 x 0.50...2.5 (18...14) Stranded [mm 2 ] / [AWG] 2 x 0.75...2.5 (18...14) Tightening Torque [Nm] / [lb-in] 1.2...1.5 (10.6...13.3) Weight [g (lb)] 94 (0.21) 39

-100 Controller Cut-Off Current -100 Controller Maximum Cut-Off Current Rated Operating Voltage 415V Maximum orward Energy Rated Operating Voltage 415V Protection of PVC Insulated Leads Against Overload and During Short-Circuit Protected Minimum Copper Cross-Section at 400V 50 Hz Catalog Number 10 mm 2 6 mm 2 4 mm 2 2.5 mm 2 1.5 mm 2 1 mm 2 0.75 mm 2-100-25A ~ ~ ~ -100-40A ~ ~ ~ ~ -100-63A ~ ~ ~ ~ ~ -100-90A ~ ~ ~ ~ ~ ~ As per IEC 364 and CENELEC coordination documents 384-3 and 384-3. In the Bulletin -100 Motor Protector, overload protection is achieved by means of the adjustable thermal releases. The maximum possible tripping current is substantially lower than in fused overload protection. Short-circuit protection is provided by the non-adjustable magnetic release which is capable of opening the main contacts very quickly. The short total breaking time limits temperature rise in the lead to a minimum in the event of a short-circuit. 40

-100 Controller Time-Current Characteristic -100 Manual Motor Starter/Protector 1. Thermal Release Operating Current The adjustable current-dependent delayed bimetal release protects motors against overload. The characteristic shows the mean at 20 C ambient temperature starting from the cold state. In equipment at operating temperature, release time is less than or equal to release time from the cold state. The precise routine test guarantees motor protection even when a phase is interrupted. Motor protection in protection type EExe: Pursuant to VDE 0165/83, the release time of the cold overload release must be less than the allowed locked-rotor time t E of the motor. The specific tripping characteristics must be available at the operating site. If necessary, they can be ordered from the appropriate Sprecher + Schuh Sales Office. or new systems, protection equipment must be provided for motors in accordance with VDE 0165/83, section 6.1.4.3.3. Such protection equipment must ensure motor protection even in the event of a phase failure. 2. Operating Current for Magnetic Releases Electromagnetic instantaneous releases react at a set tripping current. At the upper thermal release setting, this tripping current is 11 times or 14 times the set current at a lower setting. Current To Be Set Thermal releases meet the requirements for a thermal release for a starter in accordance with IEC 947. If a different value is specified (such as reduced I e in motors with a coolant temperature higher than 40 C or a site altitude >2000 m above M.S.L.), the rated operating current I e must be adjusted. Note: In certain applications such as in multi-speed motors or star delta starters for heavy duty start and/or reduced motor lead cross-sections, the 100 devices are used only as short-circuit protection, while overload protection is accomplished by thermal overload relays. The 100 motor protector must be set for a 20% higher current so that only the downstream thermal overload relays trip in the event of an overload. 41

Dimensions -100 Controller -100 Controller Dimensions are in millimeters (inches). Dimensions not intended for manufacturing purposes. 42

Notes 43