A unique density, viscosity sensor. High technology brick. Field oriented. For light & medium petroleum products. Related norms

Similar documents
Technical Offer. ViscoPro Measure Viscosity and Temperature on line for continuous process improvement

Density Solution. TDF Series. Direct Insertion Density Meter. Characteristics

Countum Group. Metering Solutions. Aviation. Metering Solutions.

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

HTM Series Helical Turbine Meters

REAL-TIME ON-LINE DENSITY ANALYSIS OF GAS & LIQUID HYDROCARBONS USING SMART MICROSYSTEMS

7829 Visconic industrial viscosity transmitter on line real time viscosity measurement

Flowmeters. The Satam flowmeter range is used for the custody transfer measurement of liquid hydrocarbons, liquid gas and liquid chemicals.

better analysis counts

FLUXUS HPI Series. Non-Intrusive Ultrasonic Flow Measurement for the Hydrocarbon Processing Industries. External Measurement of Internal Flow FLEXIM

Non-Invasive Hydrocarbon Products Mass Flow Measurement, Media Identification and Leak Detection

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

State-of-the-art viscosity monitoring

Micro Motion 7827 Digital Viscosity Meter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Armstrong In-Line and Insertion Vortex Flow Meters

Sarasota FD900 Sarasota ID900 Sarasota PD900 Gas Density Meters for Gas Metering and Control

DFX Series Liquid Ultrasonic Flow Meters

EQUALIS S. Flow computer for depots. Metering Solutions Metering Solutions. Very open communication skills. Field of application.

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

REVOLUTIONIZE YOUR GAS DENSITY AND PURITY MEASUREMENT TECHNOLOGY

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Jet Fuel Conductivity Analysers & Additive Management systems

Stabinger Viscometer Series. SVM Series

Multivariable Vortex Flow Meter

FasTrak High Capacity Smart Positioner

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Why measure viscosity in-line?

Range of Ultrasonic Flowmeters.

BARTON 7400 Precision Gas Turbine Flow Meters

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

The readings you need, right where you need them. AX Series Vortex Meters

Process Analyzer. Viscosity Index Analyzer Model P-950. Credible Solutions for the Oil and Gas Industry

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

Smart Pressure Transmitter

Pressure transducer DMU 01K Compact version

FLUXUS HPI Series External Measurement of Internal Flow

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Flash Point Process Analyzer

Multivariable Vortex Flow Meter

Densitometers L-Dens 427F Ex Density Sensor Specifications

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

Food & beverage. Oil & gas. Water & waste water

OPTIMASS 2000 Technical Datasheet

Micro Motion F-Series Coriolis Flow and Density Meters

Vortex Flow Meter Model DVH

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Vortex Flowmeter Model DVE

mass flowmeter for compressed air

Micro Motion F-Series Coriolis Flow and Density Meters

CONTOIL VZFA/VZOA , versions for higher requirements / applications

Company name: Created by: Phone:

MagFlux Q 8200 Series

Visual Level Indicators (VLI) Economy Line 6

CFPP Process Analyzer

STEEMCO-MAS Flowmeter for Steam

SATRON VDt Differential Pressure Transmitter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Flow VA 550 / 570. DVGW tested. Flow.

Varian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Options guide. Electromagnetic flowmeters. M9xx

VLM20 In-line Vortex Flowmeter

Industrial OG meter series IOG Inline and flanged oval gear meter

Electromagnetic Flow Meter Owner s Manual HARDWARE

D-2 Incorporated. JF-1A-RC RampCheck Product Brochure. Part Number: JF-1A-RC Revision Date: 09/11/15 Drawing Number: R6

Turbine flowmeters Series TM

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Guaranteed Technical Particulars(GTP) Deviation/Remarks Specify if any. Computerized Motor testing system suitable to test LV 3 phase motors

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Fuel level sensors Strela - Users manual. Fuel level sensors Strela. Users manual

OPTIMASS 3000 Technical Datasheet

INSTRUMENTATION & CONTROL TECHNOLOGIES (I&CT)

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

VIM20 Vortex Insertion Flowmeter

Vertical Tensile Machine

PRECISION METERS. Tel: / Int'l: Fax: / Int'l: Springer Pumps, LLC Telford, PA 18969

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Viscomaster TM series viscosity transmitters for marine and power HFO applications

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Pressure transmitter for marine applications MBS 3100 and MBS 3150

CHAPTER 4 VARIABLE COMPRESSION RATIO ENGINE WITH DATA ACQUISITION SYSTEM

ADU 5. Automatic Distillation Unit

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

OPTIGAS 4010C Technical Datasheet

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Description. Measurement Principle. Key Features. Applications. Malema SUMOFLO. 1 Barb Single-Use Sensor for g/min

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

SITRANS FX300 4/289. System Overview. Overview

Smart Pressure Transmitter

Transcription:

For light & medium petroleum products A unique density, viscosity sensor DEVIL for light fuels is the only density + viscosity + temperature sensor available on the market, dedicated to light refined cuts. Compact, robust and digital, the DEVIL is to be embedded onto installations such as fuel quality control systems, fuel composition analysis modules, fuel dispensers for trucks & cars, and refining process lines. It uniquely simplifies fuel monitoring and leads to more accurate custody transfer metering. High technology brick. Field oriented. Applications Pipelines / refining Quality control Fuel tanks Custody transfert metering Fueling stations Ground fueling avionics Continuous measurements Fluids Light fuels: SP95, SP98 Kerosene: JETA1, AVGAS Naphta Gasoline, mid/heavy fuel oils biodiesel GPL, GNL, Ethanol Analyzers (FTIR...) Related norms ASTM D1657 ASTM D1298 ASTM D2270 ASTM D445 ASTM D4052 ASTM D7777 ISO 2909 ISO3104 ISO3448 ISO897 A closer look at custody transfer metering Density & viscosity changes occurring to fuels during transportation degrade the metering accuracy linked to the fiscal transfer. Adding the DEVIL to conventional flow metering installations ensures that the right quantity of fuel was delivered. Cost effective refining of light fuels Density & viscosity being input measurements for a wide range of fuel analysis, embedding the DEVIL into fuel composition & quality modules allows for direct density + viscosity correction. DEVIL is also the perfect tool for dynamic blending monitoring, contributing to reduced refining cycles thanks to high-tier metrological performances and unrivaled dynamic behavior. Instant access to fuel quality Density & viscosity measurements are an inexpensive way to characterize fuel quality, ensuring its purity prior to delivery. DEVIL can either be used inline the distribution line or drown into the tank for periodic checks.

Small, smart, robust. Cutting-edge sensing elements Easy integration into lubrication lines, equipments, lab setups Reduced dimensions Delivered calibrated, plug & play Corrosion, water resistant Suitable for explosive areas Easy Connection to SCADA, wireless capability (optional)

a4 1 2 92.9 1 2 Mechanical integration Laboratory set-up Use in oven, regulated baths, or bench Featuring the fluid ring for easy/quick tests Lab handler (optional) Small pipes & bypass Used for integration into lab & process equipments, small lubrication lines, bypass out of main pipes B A Screwed in pipe 34 SW30 Used for integration into larger pipings, tanks G1/2 Flanged on pipe Used for integration into wide pipings, versatile measurements in tanks Dimensions in mm B Designat ion Size Scale A 4 DEVIL G1/ 2 - w w w.avenisense.com A A4

Communication protocols Protocol deployment USB RS485 RS232 ModBus (RS) 4-20mA (1 line per measurement) 0-10V (1 line per measurement) ModBus TCP Description!de!l interface! External convertor (installation as shown hereunder) + Safe use in explosive areas might require the use of external conversion electronics + Accessories (optional) Type AveniReader description 7 Touchscreen gathering up to 3 sensors, graph display, parameters adjustment, data storage, connection to network. LCReader Calibration kit Fluid open ring Soft2Sense Low tier reader (coming) Set of calibration fluids for metrological performance checks Metallic ring to be mounted onto the DEVIL for open air fluid pouring & checks Enhanced Windows compatible software for data collection, display, storage, multivariable graphs, compensation (equations )

Specifications GENERAL SPECIFICATIONS Measurements available Sensing technologies Measurement type Calibration Certification Volumic mass (kg.m -3 ), kinematic viscosity (cst), dynamic viscosity (cp), temperature ( C) MesoScale, Selfbalancit Continuous measurements, dynamic or static fluid conditions Factory calibration checked again independent bench test CE, ATEX II 1G Exia IIC T4 (optional) METROLOGICAL PERFORMANCES Calibration ranges Density range: Viscosity range: Equivalent viscosity @ 15 C: Density range: 600 kg.m -3 1500 kg.m -3 0.3cP 400cP // 0.3cSt 500cSt 20 000 cp 650kg.m -3 1150kg.m -3 Accuracy (typical, max) Repeatability INTEGRATION Communication protocols Hardware connection Fluid T C: Environment T C: ATEX Environment T C: Pressure: Viscosity: Density: Temperature: Viscosity: Density: Temperature: Sealing (when necessary) Max flow velocity < 1m.sec -1 Acquisition frequency 1Hz max, averaging available Response time < 2sec Weight (by pass version) 320g Wetted parts SS316L, Inconel, Hastelloy -40 C... 85 C -40 C... 110 C -40 C... 110 C Atm... 10 bar (higher on demand) 0.8% F.S. (typ) 2% F.S. (max) 0.1% F.S. (typ) 0.5% F.S. (max) 0.2 C (typ) 0.5 C (max) 0.5% F.S. 0.1% F.S. 0.1 C USB, RS232, RS485, ModBus, Analog 4-20mA, Analog 0-10V, ModBus TCP Lab use: Handy with open ring for fluid pooring Integration into equipment: NPT/GAS, from 1/8 to 1.5 Integration onto large pipes: Screwed onto the pipe (G1/2 ) Flanged onto the pipe (mini PN40 DN15, other on demand) Integration into tanks: Screwed onto the pipe (G1/2) Bypass: NPT/GAS, from 1/8 to 1.5 (piece of flow line) Viton, Kalrez Indicated performances have been obtained in controlled laboratory conditions using sensor's digital output. In practice, additional inaccuracy might arise due to application's conditions, use of the analog mode, fluid characteristics. Powered by www.avenisense.com T/F +33 (0)4 5708 0225 Skype: deskavenisense contact@avenisense.com sales@avenisense.com return@avenisense.com AVENISENSE S.A.S. Savoie Technolac BP233 17, avenue du Lac Léman 73374 Le Bourget du Lac Cedex FRANCE