For light & medium petroleum products A unique density, viscosity sensor DEVIL for light fuels is the only density + viscosity + temperature sensor available on the market, dedicated to light refined cuts. Compact, robust and digital, the DEVIL is to be embedded onto installations such as fuel quality control systems, fuel composition analysis modules, fuel dispensers for trucks & cars, and refining process lines. It uniquely simplifies fuel monitoring and leads to more accurate custody transfer metering. High technology brick. Field oriented. Applications Pipelines / refining Quality control Fuel tanks Custody transfert metering Fueling stations Ground fueling avionics Continuous measurements Fluids Light fuels: SP95, SP98 Kerosene: JETA1, AVGAS Naphta Gasoline, mid/heavy fuel oils biodiesel GPL, GNL, Ethanol Analyzers (FTIR...) Related norms ASTM D1657 ASTM D1298 ASTM D2270 ASTM D445 ASTM D4052 ASTM D7777 ISO 2909 ISO3104 ISO3448 ISO897 A closer look at custody transfer metering Density & viscosity changes occurring to fuels during transportation degrade the metering accuracy linked to the fiscal transfer. Adding the DEVIL to conventional flow metering installations ensures that the right quantity of fuel was delivered. Cost effective refining of light fuels Density & viscosity being input measurements for a wide range of fuel analysis, embedding the DEVIL into fuel composition & quality modules allows for direct density + viscosity correction. DEVIL is also the perfect tool for dynamic blending monitoring, contributing to reduced refining cycles thanks to high-tier metrological performances and unrivaled dynamic behavior. Instant access to fuel quality Density & viscosity measurements are an inexpensive way to characterize fuel quality, ensuring its purity prior to delivery. DEVIL can either be used inline the distribution line or drown into the tank for periodic checks.
Small, smart, robust. Cutting-edge sensing elements Easy integration into lubrication lines, equipments, lab setups Reduced dimensions Delivered calibrated, plug & play Corrosion, water resistant Suitable for explosive areas Easy Connection to SCADA, wireless capability (optional)
a4 1 2 92.9 1 2 Mechanical integration Laboratory set-up Use in oven, regulated baths, or bench Featuring the fluid ring for easy/quick tests Lab handler (optional) Small pipes & bypass Used for integration into lab & process equipments, small lubrication lines, bypass out of main pipes B A Screwed in pipe 34 SW30 Used for integration into larger pipings, tanks G1/2 Flanged on pipe Used for integration into wide pipings, versatile measurements in tanks Dimensions in mm B Designat ion Size Scale A 4 DEVIL G1/ 2 - w w w.avenisense.com A A4
Communication protocols Protocol deployment USB RS485 RS232 ModBus (RS) 4-20mA (1 line per measurement) 0-10V (1 line per measurement) ModBus TCP Description!de!l interface! External convertor (installation as shown hereunder) + Safe use in explosive areas might require the use of external conversion electronics + Accessories (optional) Type AveniReader description 7 Touchscreen gathering up to 3 sensors, graph display, parameters adjustment, data storage, connection to network. LCReader Calibration kit Fluid open ring Soft2Sense Low tier reader (coming) Set of calibration fluids for metrological performance checks Metallic ring to be mounted onto the DEVIL for open air fluid pouring & checks Enhanced Windows compatible software for data collection, display, storage, multivariable graphs, compensation (equations )
Specifications GENERAL SPECIFICATIONS Measurements available Sensing technologies Measurement type Calibration Certification Volumic mass (kg.m -3 ), kinematic viscosity (cst), dynamic viscosity (cp), temperature ( C) MesoScale, Selfbalancit Continuous measurements, dynamic or static fluid conditions Factory calibration checked again independent bench test CE, ATEX II 1G Exia IIC T4 (optional) METROLOGICAL PERFORMANCES Calibration ranges Density range: Viscosity range: Equivalent viscosity @ 15 C: Density range: 600 kg.m -3 1500 kg.m -3 0.3cP 400cP // 0.3cSt 500cSt 20 000 cp 650kg.m -3 1150kg.m -3 Accuracy (typical, max) Repeatability INTEGRATION Communication protocols Hardware connection Fluid T C: Environment T C: ATEX Environment T C: Pressure: Viscosity: Density: Temperature: Viscosity: Density: Temperature: Sealing (when necessary) Max flow velocity < 1m.sec -1 Acquisition frequency 1Hz max, averaging available Response time < 2sec Weight (by pass version) 320g Wetted parts SS316L, Inconel, Hastelloy -40 C... 85 C -40 C... 110 C -40 C... 110 C Atm... 10 bar (higher on demand) 0.8% F.S. (typ) 2% F.S. (max) 0.1% F.S. (typ) 0.5% F.S. (max) 0.2 C (typ) 0.5 C (max) 0.5% F.S. 0.1% F.S. 0.1 C USB, RS232, RS485, ModBus, Analog 4-20mA, Analog 0-10V, ModBus TCP Lab use: Handy with open ring for fluid pooring Integration into equipment: NPT/GAS, from 1/8 to 1.5 Integration onto large pipes: Screwed onto the pipe (G1/2 ) Flanged onto the pipe (mini PN40 DN15, other on demand) Integration into tanks: Screwed onto the pipe (G1/2) Bypass: NPT/GAS, from 1/8 to 1.5 (piece of flow line) Viton, Kalrez Indicated performances have been obtained in controlled laboratory conditions using sensor's digital output. In practice, additional inaccuracy might arise due to application's conditions, use of the analog mode, fluid characteristics. Powered by www.avenisense.com T/F +33 (0)4 5708 0225 Skype: deskavenisense contact@avenisense.com sales@avenisense.com return@avenisense.com AVENISENSE S.A.S. Savoie Technolac BP233 17, avenue du Lac Léman 73374 Le Bourget du Lac Cedex FRANCE