SWCC Summary Report Manufacturer: Wind Turbine Model: Certification Number: Lely Aircon This report summarizes the results of testing and certification of the Lely Aircon LA10 in accordance with AWEA 9.1-2009. The LA10 is a 3-blade, upwind, stall regulated, horizontal axis wind turbine with a rotor diameter of 7.6 m and swept area of 44.8 m 2. All testing was performed on a turbine system utilizing Control Techniques Unidrive grid-tie inverter and a 30 m (98 ) lattice tower at a test site near Witzwort, Germany. Power Performance testing was performed from 01 February 2011 through 19 February 2011 by Ingenieurbüro Dr. Ing. Dieter Frey. Duration testing was performed from 20 August 2010 through 12 March 2011 by Ingenieurbüro Dr. Ing. Dieter Frey. Safety and Function testing was performed on 19 September 2011 by GL Garrad Hassan Deutschland GmbH. Acoustic testing was performed on 11 March 2011 by GL Garrad Hassan Deutschland GmbH. 1. Turbine Ratings The LA10 performance testing was conducted in accordance with Section 2 of AWEA 9.1-2009. The resulting turbine ratings, tabulated graphical Annual Energy Production (AEP), and graphical and tabulated power curve are given below. AWEA Rated Annual Energy @ 5 m/s AWEA Rated Sound Level AWEA Rated Power @ 11 m/s Peak Power @ 21.5 m/s LA10 (480 VAC, 3-phase, 60 Hz) SWCC-16-01 The above-identified Small Wind Turbine is certified by the Solar Rating & Certification Corporation - Small Wind Certification Program to be in conformance with the AWEA Small Wind Turbine Performance and Safety (AWEA 9.1 2009). For the SWCC Certificate visit: www.smallwindcertification.org 17,500 kwh 41.1 db(a) 9.6 kw 11.3 kw
2. Tabulated Annual Energy Production (AEP) Corrected to a sea level air density of 1.225 kg/m 3 Hub Height Annual Average Wind Speed (m/s) AEP Measured (kwh) Uncertainty in AEP (kwh) Uncertainty in AEP (%) AEP Extrapolated (kwh) 4 9,065 880 10% 9,065 5 17,488 1238 7% 17,488 6 26,711 1466 6% 26,714 7 35,561 1571 4% 35,599 8 43,335 1593 4% 43,549 9 49,631 1567 3% 50,307 10 54,261 1514 3% 55,731 11 57,243 1446 3% 59,788 3. Annual Energy Production Curve Estimated Annual Energy Production (AEP-measured) with Uncertainty Aircon LA10 Reference air density: 1.225 kg/m 3
4. Power Curve Power Curve with Combined Uncertainty Aircon LA10 Reference air density: 1.225 kg/m 3
5. Tabulated Power Curve Bin No. Corrected to a sea level air density of 1.225 kg/m 3 Category A Category B Combined Hub Height Wind Speed Power Output Cp 1-minute samples Uncertainty, Si Uncertainty, Ui Uncertainty, Ci m/s Watts Watts Watts Watts 1 1.50 0 0 0 0 0 2 2.00 0 0 0 0 0 3 2.60-132 7 36 17 39 4 3.03-79 36 12 19 22 5 3.54 9 0.01 58 13 41 43 6 4.02 312 0.17 34 24 72 76 7 4.57 680 0.26 32 32 99 104 8 5.00 1,120 0.33 75 25 131 134 9 5.52 1,650 0.36 125 20 151 153 10 6.00 2,203 0.37 248 18 186 187 11 6.49 2,855 0.38 286 19 225 226 12 6.99 3,600 0.38 260 22 258 259 13 7.48 4,344 0.38 177 30 285 286 14 7.99 5,159 0.37 130 42 322 324 15 8.48 6,022 0.36 150 41 347 350 16 9.01 6,892 0.34 143 45 382 385 17 9.50 7,826 0.33 163 39 367 369 18 10.00 8,500 0.31 199 39 326 329 19 10.51 9,186 0.29 191 42 285 288 20 10.99 9,608 0.26 142 46 250 254 21 11.46 10,080 0.24 177 39 202 206 22 11.99 10,310 0.22 103 61 118 133 23 12.47 10,400 0.20 81 68 108 127 24 12.98 10,570 0.18 59 91 80 121 25 13.52 10,480 0.15 71 72 77 105 26 14.02 10,600 0.14 78 63 82 104 27 14.53 10,570 0.13 110 38 77 86 28 14.98 10,600 0.11 140 34 77 84 29 15.52 10,560 0.10 139 34 77 84 30 15.98 10,600 0.09 137 44 78 90 31 16.47 10,600 0.09 88 57 95 111 32 17.00 10,740 0.08 56 109 167 199 33 17.53 10,990 0.07 46 109 113 157 34 17.98 10,940 0.07 34 145 80 165 35 18.50 10,980 0.06 50 104 83 133 36 18.97 10,990 0.06 45 102 87 134 37 19.48 11,050 0.05 41 99 80 128 38 19.99 10,990 0.05 54 80 99 127 39 20.51 10,920 0.05 31 72 115 136 40 20.95 11,160 0.04 21 121 220 252 41 21.41 11,310 0.04 17 146 82 168
6. Tabulated Acoustic Data The LA10 was tested in accordance with Section 3 of AWEA 9.1-2009. The tabulated Sound Power Level is provided for specific wind speed bins. Wind Speed at 10m Height m/s 6 7 8 9 10 Measured Turbine Sound Level Measured Background Sound Level Background Corrected Sound Level db(a) db(a) db(a) 43.3 40.5-45.1 41.6 43.8 47.1 43.1 45.8 49.2 45.1 47.9 51.1 47.4 49.8 Apparent Sound Power Level db(a) Combined Uncertainty db(a) - - 82.1 2.2 84.1 1.8 86.1 1.8 88.1 2.0 7. Graphical Acoustic Data (from GLGH report GLGH-4286 11 07736 258-A-0001-A)
8. Duration Testing The LA10 successfully completed a Duration Test for an IEC Class II Small Wind Turbine with an Operational Time Fraction of 97.5%. The highest instantaneous wind speed recorded during the test was 31.0 m/s (69.3 mph). The average turbulence intensity at 15 m/s was 10.4 %. 9. Mechanical Strength Analysis The mechanical strength analysis was found to be in conformance with IEC 61400-2 as modified by section 4 of AWEA 9.1 2009 for an IEC Class II Small Wind Turbine. 10. Safety and Function testing Safety and Function testing was found to be in conformance with sections 4.3 and 4.4 of AWEA 9.1 2009.
11. Manufacturer Tower Design Requirements (SRCC is not responsible for any errors in the document below, which is provided by the manufacturer). Basic tower design requirements Turbine Model Aircon LA10 Power rating 9.8 kw Tower top mass 722 kg Rotor diameter 7.56 m Number of blades 3 Rotor swept area 44.88 m² Extreme wind speed Ve1 (one-year occurrence) 47.6 m/s Extreme wind speed Ve50 (fifty-year occurrence) 59.5 m/s Lateral thrust at Ve50 (parked rotor) 14 kn Distance mounting flange face to rotor axis 0.500 m Distance tower center to center of gravity nacelle 0.354 m Distance from tower center to rotor center 0.624 m Thrust offset from tower centre axis 0 m Turbine mass offset from tower centre 0 m Maximum shaft braking torque 3.10 knm Rotor speed at rated power 108 rpm Rotor speed maximum 130 rpm Maximum tower top deflection at Ve50 as a percentage of height 0.65 % Natural frequency range 1.8 Hz (1P)/ 5.4 Hz (2P) Rotor tilt angle 3.0 deg Minimum blade/tower clearance (at blade tip) 0.47 m Rotorblade 1. flap wise natural frequency, dynamic 6.23 6.24 Hz 2. flap wise natural frequency, dynamic 24.01-24.05 Hz 1. edge wise natural frequency, dynamic 18.27 18.30 Hz 2. edge wise natural frequency, dynamic 122.45 122.64 Hz Tower 1. mode longitudinal/transverse, dynamic 2.073 Hz 2. mode longitudinal/transverse, dynamic 7.800 Hz Torsion, dynamic 2.146 Hz Nacelle, yaw, dynamic 5.47 Hz Mechanical and electrical Connection Please refer to the installation manual chapter 4 for the mechanical and electrical installation of the Lely Aircon LA10 (Document No. 7.1001.8509.0) which is available from Lely Aircon.
Mechanical Connection, Nacelle to Tower Minimum Blade/Tower Clearance
Please note: The above Tower Design Requirements information is provided for reference only. Please obtain the Tower Design Specifications document from Lely Aircon. Lely Aircon has a policy of allowing the LA10 turbine to be installed only on towers approved by Lely Airco