ISEO IMF Product Brochure

Similar documents
MULTIFLOW SEL Product Brochure

REVOLUTION SLCX Product Brochure

BIFLOW SB CON Product Brochure

QUBE SQU-HT(S) Product Brochure

TWINFLOW STDR Product Brochure

CLASSIC SAX Window / Wall Mounted Axial Fan. Select models available for next day delivery

BOX BLB Centrifugal Box Fan

ZOO FAN SDF Destratification Ceiling Mounted Fan

SKYFLOW SSR Product Brochure

TURBOFLOW TF Contra Rotating Axial Flow Fan

Elta Select Product Guide 2016

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH)

Square Mixed Flow Fans (MFQ)

Sentinel D-Box Single Fan

Sentinel D-Box Twin Fan

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Sabre Plate Mounted Sickle Fans (VSP)

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

NEW Acoustic In-Line Fans (ACQ)

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Vent-Axia Sabre Sickle Roof Fans (VSR)

NEW Slimpak EC Box Fan (SLPT EC)

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

LC/SC. Long & Short Cased Axial Fans

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

HIGH-POWERED VENTILATORS

Performance. Sound Levels. Impellers. Motors. Accessories

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

IDENTIFICATION ACCESSORIES DESCRIPTION

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

HIGH TEMPERATURE TWIN SQUIF FANS

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Acoustic Twin Fans (ATQ)

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

Bifurcated Case Axial Fans (BIFA)

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

NCF fans 50 Hz. Protection class IP 55

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Highline 260i EC Waterside Fan Coil Unit

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

Axial fans. What s more, non-stock models are normally available within two weeks.

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

COMFORT AIR CURTAIN. SensAir

Uniclass L7534. Manufacture controlled to ISO9001

VORTICENT C E RANGE Centrifugal fans

Unobox units with backward curved centrifugal impellers

CENTRIFUGAL IN-LINE FANS VENT Series

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

SILENT MV Ultra Quiet In-line Fans

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

AXIAL FANS Catalogue CN0050C01 May 2008

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Multi-Port Centrifugal Fans for Round Duct

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

COMFORT AIR CURTAIN. SensAir

Single-inlet centrifugal fans

WINDER. Impellers with higher efficiency and less sound level

AC axial fan. sickled blades (S series) Wall ring with guard grille

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

TD-ECOWATT AND DECOR-ECOWATT Series

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

BSB SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

MegaBox Product-specific information

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

QBX ACOUSTIC CENTRIFUGAL BOX ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

Airscrew 200+ Vmax Vaneaxial Fans

ROOFMASTER STEF-HT ROOF FAN

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

MAJAX-2 GENERAL SPECIFICATION

Small centrifugal fans made of plastic

Plate mounted axial flow fans HXBR / HXTR Series

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

Compact Design BB101 & 93

AC axial fan. sickled blades (S series) with guard grille for full nozzle

Transcription:

ISEO IMF Product Brochure Available for next day delivery with ELTA SELECT

In-Line Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit homevent.co.uk. QUICK FACTS ü Moulded mounting bracket for quick installation ü Double Insulated, no earth connections required ü Totally recyclable plastic components, environmentally friendly ü Reliability Sealed for life ball bearings ü Motors Two speed AC permanent capacitor induction type ü Impeller Mixed flow impeller for high performance & silent operation CASING The all plastic fan casing provides a long lasting shockproof and robust construction. The units are finished in white RAL 9010 and are UV resistant. IMPELLER Mixed flow impellers are provided with blades made from high quality plastic. MOTORS Two speed permanent capacitor totally enclosed induction type with integral thermal overload protection, mounted on sealed for life ball bearings. All fans are double insulated. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. TYPICAL APPLICATIONS Variety of industrial, light commercial & domestic applications, including: Toilets Café Entrance Halls Duct Ventilation Boost Bathrooms Equipment Cooling Air Curtain Supply Restaurants For full accessories & controls information please contact Elta Fans Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 2

Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code ISEO IMF 100 ISEO IMF 100T ISEO IMF 125 ISEO IMF 125T ISEO IMF 150 ISEO IMF 150T ISEO IMF 200 ISEO IMF 200T Speed r/min 2490 2340 2490 2340 2434 2226 2434 2226 Airflow SFP Airflow m³/s @ Static Pressure Pa. 0 25 50 75 100 150 200 250 m³/s 0.065 0.057 0.047 0.036 0.026 0.008 Overall Efficiency % FMEG Motor Electrical Data Peak Amps Input kw 12.4 <125W 0.15 0.027 dba @ 3m Inlet 47 Outlet 45 W/(L/s) 0.49 0.53 0.59 0.72 0.95 2.64 Break Out 41 m³/s 0.057 0.050 0.040 0.029 0.018 0.003 9.8 <125W 0.15 - Outlet 41 W/(L/s) 0.56 0.60 0.68 0.88 1.32 6.85 Break Out 36 m³/s 0.065 0.057 0.047 0.036 0.026 0.008 12.4 <125W 0.15 0.027 Inlet 47 Outlet 45 W/(L/s) 0.49 0.53 0.59 0.72 0.95 2.64 Break Out 41 m³/s 0.057 0.050 0.040 0.029 0.018 0.003 9.8 <125W 0.15 - Outlet 41 W/(L/s) 0.56 0.60 0.68 0.88 1.32 6.85 Break Out 36 m³/s 0.095 0.087 0.075 0.056 0.031 0.002 17.2 <125W 0.15 0.031 Inlet 44 W/(L/s) 0.36 0.39 0.43 0.53 0.83 8.73 Break Out 41 m³/s 0.082 0.071 0.056 0.038 0.020 11.6 <125W 0.15 - Inlet 41 Outlet 38 W/(L/s) 0.41 0.46 0.55 0.72 1.17 Break Out 36 m³/s 0.095 0.087 0.075 0.056 0.031 0.002 17.2 <125W 0.15 0.031 Inlet 44 W/(L/s) 0.36 0.39 0.43 0.53 0.83 8.73 Break Out 41 m³/s 0.082 0.071 0.056 0.038 0.020 11.6 <125W 0.15 - Inlet 41 Outlet 38 W/(L/s) 0.41 0.46 0.55 0.72 1.17 Break Out 36 m³/s 0.163 0.157 0.151 0.144 0.136 0.118 32.6 <125W 0.31 0.064 Inlet 49 Outlet 48 W/(L/s) 0.43 0.44 0.46 0.48 0.50 0.55 Break Out 45 m³/s 0.123 0.118 0.113 0.106 0.097 0.068 0.025 22.9 <125W 0.25 - W/(L/s) 0.48 0.49 0.52 0.54 0.57 0.70 1.52 Break Out 38 m³/s 0.163 0.157 0.151 0.144 0.136 0.118 32.6 <125W 0.31 0.064 Inlet 49 Outlet 48 W/(L/s) 0.43 0.44 0.46 0.48 0.50 0.55 Break Out 45 m³/s 0.123 0.118 0.113 0.106 0.097 0.068 0.025 22.9 <125W 0.25 - W/(L/s) 0.48 0.49 0.52 0.54 0.57 0.70 1.52 Break Out 38 m³/s 0.258 0.250 0.244 0.236 0.227 0.205 0.174 33.6 <125W 0.55 0.113 Inlet 53 Outlet 57 W/(L/s) 0.46 0.48 0.49 0.51 0.52 0.57 0.65 Break Out 50 m³/s 0.222 0.214 0.205 0.195 0.183 0.153 0.097 26.3 <125W 0.51 - Inlet 51 Outlet 53 W/(L/s) 0.47 0.49 0.51 0.54 0.57 0.64 0.85 Break Out 45 m³/s 0.258 0.250 0.244 0.236 0.227 0.205 0.174 33.6 <125W 0.55 0.113 Inlet 53 Outlet 57 W/(L/s) 0.46 0.48 0.49 0.51 0.52 0.57 0.65 Break Out 50 m³/s 0.222 0.214 0.205 0.195 0.183 0.153 0.097 26.3 <125W 0.51 - Inlet 51 Outlet 53 W/(L/s) 0.47 0.49 0.51 0.54 0.57 0.64 0.85 Break Out 45 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 3

Dimensional Data G H B øf øa D E C Product Code A B C D E F G H ISEO IMF 100 97 296 179 104 113 174 154 139.6 ISEO IMF 125 124 256 179 102 113 174 154 139.6 ISEO IMF 150 147 300 195 112 127 194 182 170 ISEO IMF 200 198 314 254 126 145 220 236 120 Dimensions are in mm. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 4

Notes Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 5

Applied Technology Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: at@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom Building Services Tel: +44 (0) 1384 275800 Fax: +44 (0) 1384 275810 Email: bs@eltafans.co.uk 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US United Kingdom Export Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: export@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom www.eltafans.com BS EN ISO 9001:2008 FM 556465 A member of HEVAC ASSOCIATION