ISEO IMF Product Brochure Available for next day delivery with ELTA SELECT
In-Line Mixed Flow Fan For full detailed information on the following: Sound Data, Accessories & Wiring Data and Optimum Energy Efficiency Point please visit homevent.co.uk. QUICK FACTS ü Moulded mounting bracket for quick installation ü Double Insulated, no earth connections required ü Totally recyclable plastic components, environmentally friendly ü Reliability Sealed for life ball bearings ü Motors Two speed AC permanent capacitor induction type ü Impeller Mixed flow impeller for high performance & silent operation CASING The all plastic fan casing provides a long lasting shockproof and robust construction. The units are finished in white RAL 9010 and are UV resistant. IMPELLER Mixed flow impellers are provided with blades made from high quality plastic. MOTORS Two speed permanent capacitor totally enclosed induction type with integral thermal overload protection, mounted on sealed for life ball bearings. All fans are double insulated. QUALITY MANAGEMENT All units in the Elta range are designed and manufactured to procedures as defined in BS EN ISO 9001:2008. TYPICAL APPLICATIONS Variety of industrial, light commercial & domestic applications, including: Toilets Café Entrance Halls Duct Ventilation Boost Bathrooms Equipment Cooling Air Curtain Supply Restaurants For full accessories & controls information please contact Elta Fans Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 2
Performance, SFP & Electrical Data SINGLE Phase - 220V to 240V / 50Hz Product Code ISEO IMF 100 ISEO IMF 100T ISEO IMF 125 ISEO IMF 125T ISEO IMF 150 ISEO IMF 150T ISEO IMF 200 ISEO IMF 200T Speed r/min 2490 2340 2490 2340 2434 2226 2434 2226 Airflow SFP Airflow m³/s @ Static Pressure Pa. 0 25 50 75 100 150 200 250 m³/s 0.065 0.057 0.047 0.036 0.026 0.008 Overall Efficiency % FMEG Motor Electrical Data Peak Amps Input kw 12.4 <125W 0.15 0.027 dba @ 3m Inlet 47 Outlet 45 W/(L/s) 0.49 0.53 0.59 0.72 0.95 2.64 Break Out 41 m³/s 0.057 0.050 0.040 0.029 0.018 0.003 9.8 <125W 0.15 - Outlet 41 W/(L/s) 0.56 0.60 0.68 0.88 1.32 6.85 Break Out 36 m³/s 0.065 0.057 0.047 0.036 0.026 0.008 12.4 <125W 0.15 0.027 Inlet 47 Outlet 45 W/(L/s) 0.49 0.53 0.59 0.72 0.95 2.64 Break Out 41 m³/s 0.057 0.050 0.040 0.029 0.018 0.003 9.8 <125W 0.15 - Outlet 41 W/(L/s) 0.56 0.60 0.68 0.88 1.32 6.85 Break Out 36 m³/s 0.095 0.087 0.075 0.056 0.031 0.002 17.2 <125W 0.15 0.031 Inlet 44 W/(L/s) 0.36 0.39 0.43 0.53 0.83 8.73 Break Out 41 m³/s 0.082 0.071 0.056 0.038 0.020 11.6 <125W 0.15 - Inlet 41 Outlet 38 W/(L/s) 0.41 0.46 0.55 0.72 1.17 Break Out 36 m³/s 0.095 0.087 0.075 0.056 0.031 0.002 17.2 <125W 0.15 0.031 Inlet 44 W/(L/s) 0.36 0.39 0.43 0.53 0.83 8.73 Break Out 41 m³/s 0.082 0.071 0.056 0.038 0.020 11.6 <125W 0.15 - Inlet 41 Outlet 38 W/(L/s) 0.41 0.46 0.55 0.72 1.17 Break Out 36 m³/s 0.163 0.157 0.151 0.144 0.136 0.118 32.6 <125W 0.31 0.064 Inlet 49 Outlet 48 W/(L/s) 0.43 0.44 0.46 0.48 0.50 0.55 Break Out 45 m³/s 0.123 0.118 0.113 0.106 0.097 0.068 0.025 22.9 <125W 0.25 - W/(L/s) 0.48 0.49 0.52 0.54 0.57 0.70 1.52 Break Out 38 m³/s 0.163 0.157 0.151 0.144 0.136 0.118 32.6 <125W 0.31 0.064 Inlet 49 Outlet 48 W/(L/s) 0.43 0.44 0.46 0.48 0.50 0.55 Break Out 45 m³/s 0.123 0.118 0.113 0.106 0.097 0.068 0.025 22.9 <125W 0.25 - W/(L/s) 0.48 0.49 0.52 0.54 0.57 0.70 1.52 Break Out 38 m³/s 0.258 0.250 0.244 0.236 0.227 0.205 0.174 33.6 <125W 0.55 0.113 Inlet 53 Outlet 57 W/(L/s) 0.46 0.48 0.49 0.51 0.52 0.57 0.65 Break Out 50 m³/s 0.222 0.214 0.205 0.195 0.183 0.153 0.097 26.3 <125W 0.51 - Inlet 51 Outlet 53 W/(L/s) 0.47 0.49 0.51 0.54 0.57 0.64 0.85 Break Out 45 m³/s 0.258 0.250 0.244 0.236 0.227 0.205 0.174 33.6 <125W 0.55 0.113 Inlet 53 Outlet 57 W/(L/s) 0.46 0.48 0.49 0.51 0.52 0.57 0.65 Break Out 50 m³/s 0.222 0.214 0.205 0.195 0.183 0.153 0.097 26.3 <125W 0.51 - Inlet 51 Outlet 53 W/(L/s) 0.47 0.49 0.51 0.54 0.57 0.64 0.85 Break Out 45 Data in accordance with ErP 327/2011 of the European Parliament. Measurement category used to determine energy efficiency: D. Data provided at standard air density of 1.2 kg/m³. The overall A-weighted sound pressure level is at a distance of 3m with spherical free-field propagation. It is expressed in db re-20µpa and is presented for comparative purposes only. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 3
Dimensional Data G H B øf øa D E C Product Code A B C D E F G H ISEO IMF 100 97 296 179 104 113 174 154 139.6 ISEO IMF 125 124 256 179 102 113 174 154 139.6 ISEO IMF 150 147 300 195 112 127 194 182 170 ISEO IMF 200 198 314 254 126 145 220 236 120 Dimensions are in mm. Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 4
Notes Tel: 01384 275800 Fax: 01384 275810 Email: bs@eltafans.co.uk Visit: eltaselect.com Twitter: @eltafans 5
Applied Technology Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: at@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom Building Services Tel: +44 (0) 1384 275800 Fax: +44 (0) 1384 275810 Email: bs@eltafans.co.uk 46 Third Avenue, Pensnett Trading Estate, Kingswinford, West Midlands, DY6 7US United Kingdom Export Tel: +44 (0) 1489 566500 Fax: +44 (0) 1489 566555 Email: export@eltafans.co.uk 17 Barnes Wallis Road, Segensworth East Industrial Estate, Fareham, Hampshire, PO15 5ST United Kingdom www.eltafans.com BS EN ISO 9001:2008 FM 556465 A member of HEVAC ASSOCIATION