C2 Wiring 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE. Serial # Box. Installation Date. Wiring Type. See page 7 for other wiring configurations

Similar documents
HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

OWNER'S MANUAL. MGJ (S-Series) MODEL INDUSTRIAL DUTY DOOR OPERATOR FOR USE WITH SS90 FIRE DOOR CONTROLLER 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE

COOKSON OWNER'S MANUAL

OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR 2 YEAR WARRANTY. Serial # (located on electrical box cover) Installation Date.

OWNER S MANUAL MODEL NO. MEDIUM DUTY JACK SHAFT OPERATOR MDJ, MDJH, MDJB, MDJBH READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

MODELS LGO50113R and LGO50113L

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

OWNER'S MANUAL. C2 Wiring SOLID STATE INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

LMPLC EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

EXTREME R MOTOR OWNER'S MANUAL

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

FDO AU & BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

COOKSON OWNER S MANUAL

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

COOKSON OWNER'S MANUAL

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

FDO AU AND BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MEDIUM DUTY DOOR OPERATOR MODELS MT5011U & BMT5011U

Model JG Industrial Gearhead Jackshaft Door Operator Safety, Installation, and Service Manual

INSTALLATION AND OWNER'S MANUAL Model GJ & MGJ Gear Reduced Jackshaft

MODEL MG Gearhead Operator

MODELS BG770 & BG790 VEHICULAR BARRIER GATE OPERATOR

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

LMPLC OWNER S MANUAL MODEL FDCL. B2 Wiring ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE

OWNER S MANUAL VEHICULAR BARRIER GATE OPERATOR

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Operator

GH INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

INSTALLATION AND OWNER S MANUAL M50JF & M50JH M-SERIES JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS

OWNER'S MANUAL MODEL GH

HIGH SPEED SLIDING GATE OPENER

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

MJ & MH M-S SERIES JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS with SOLID STATE CONTROLS

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Door Operator

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

PREMIUM Series 1/2 hp Chain Drive Garage Door Opener

Installation and Maintenance Manual

GARAGE DOOR OPENER Model 3800

INSTALLATION M ANUAL

LMPLC OWNER S MANUAL MODEL FDCL ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE

MODEL D-SBG Single Arm Barrier Gate Operator

Roller Door Operator

SKC400U SLIDING GATE OPENER OWNER S MANUAL

MODEL SCA Installation and Operation Manual Important:

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

OWNER'S MANUAL J H HJ. C2 Wiring MODELS: LOGIC CONTROL (VER. 2.0) INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

ControlHoist Standard

PowerMaster Model SG

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual

Chain Drive Garage Door Opener Model 8360 FOR RESIDENTIAL USE ONLY

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Best Diversified Products, Inc. Product Manual. BestReach Rigid Belt. Models BRB 230 OS BRB 230 SS BRB 460 OS BRB 460 SS

GARAGE DOOR OPENER Model 3595LM 3/4 HP

UltraSlim Mechanical Install & Owner s Manual

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR

MODEL MSW Medium Duty Swing Gate Operator

PN: 6410T0022 Rev. 8/18/2014 Revision D Albany RR300 Stainless Mechanical Install & Owner s Manual

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

Installation, Operation and Maintenance Manual

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Owner's/Installation Manual

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

MODEL WBG WISHBONE BARRIER GATE OPERATOR

CONTENTS. 3/4 hp Belt Drive Garage Door Opener. Model HD630EVP FOR RESIDENTIAL USE ONLY

APOLLO Gate Operators, Inc.

MODELS BG770 & BG790 VEHICULAR BARRIER GATE OPERATOR

GARAGE DOOR OPENER Model /2 HP

Installation Manual. Models

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS

3/4 hp Belt Drive Garage Door Opener. Model HD620EV

MODEL D-WBG Wishbone Arm Barrier Gate Operator

GARAGE DOOR OPENER. Owner s Manual. Series CG40 1/2 HP. For Residential Use Only

AUTOMATIC CONTROL ROLLING DOOR OPENER

Models. ELITE Series Garage Door Opener CONTENTS DC Belt Drive with Battery Backup /4 hp Belt Drive FOR RESIDENTIAL USE ONLY

GARAGE DOOR OPENER. Model M375-1/2HP. Owner s Manual. For Residential Use Only

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

Installation Manual. Model 8155

Installation Instructions For Motor Control Center (MCC) Units

Instruction Manual for the. E-SL 450 Series

Operational & Manual. Maintenance. Products:

Transcription:

PLACE RATING LABEL HERE B6 O W N E R S M A N U A L FACTORY SET C Wiring See page 7 for other wiring configurations E G J EUREAN STYLE GEARHEAD DAMP ENVIRONMENT JACKSHAFT THE CHAMBERLAIN GROUP, INC. ELMHURST, ILLINOIS 606 LISTED DOOR ERATOR YEAR WARRANTY NOT FOR RESIDENTIAL USE Serial # Box Installation Date Wiring Type

TABLE OF CONTENTS SPECIFICATIONS Operator Specifications................................ Operator Dimensions.................................. PREPARATION.................................... INSTALLATION Typical Hollow Shaft................................... Optional Through-Shaft................................ Entrapment Protection Accessories (Optional)............... ADJUSTMENT Limit Adjustment..................................... Coarse Adjustment.................................... Fine Adjustment...................................... Slipping Clutch Adjustment.............................6 POWER WIRING CONNECTIONS Power Wiring........................................7 Conduit & Fittings....................................7 Conduit & Fitting Preparation............................7 Attachment to Enclosure...............................7 CONTROL WIRING Wiring Types........................................ Special Control Wiring................................. Locating the Control Station............................. Radio Controls.......................................9 Additional Access Control Equipment.....................9 External Interlock Switch...............................9 TEST THE SYSTEM.................................9 DIAGRAMS Phase Schematic Diagram...........................0 Phase Field Connection Diagram....................... Phase Schematic Diagram........................... Phase Field Connection Diagram....................... ERATION AND MAINTENANCE Manual Disconnect................................... MAINTENANCE SCHEDULE........................ REPAIR PARTS Repair Parts Kits - Wall Mounted Starter..................6 Illustrated Parts -Wall Mounted Starter...................7 Repair Parts Kits - Typical Hollow Shaft................... Illustrated Parts -Optional Through Shaft..................9 Mechanical Electrical CAUTION IMPORTANT NOTES: BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your door and/or the door operator if you do not comply with the cautionary statements that accompany it. Read them carefully.

ERATOR SPECIFICATIONS To reduce the risk of SEVERE INJURY or DEATH, ALWAYS install reversing sensors when the -Button control station is out of sight of door or any other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. MOTOR TYPE:..............................Gearhead Jackshaft HORSEPOWER:................................/ HP SPEED:...................................7 RPM VOLTAGE:.........................../0V Phase 0/60V Phase CURRENT:........................See Motor Nameplate ELECTRICAL TRANSFORMER:................................Vac CONTROL STATION:.............NEMA -Button Station. EN/OSE/ST WIRING TYPE:...........................C (Standard) Momentary contact to EN & ST, constant pressure to OSE, plus wiring for sensing device to reverse and auxiliary devices to open and close with open override. See page 9 for optional wiring types and operating modes. LIMIT ADJUST:..............Linear driven, fully adjustable screw type cams. Adjustable to 0'. BRAKE:........Dynamic brake, provides electrical braking in the form of DC current to stop the motor. MECHANICAL DRIVE REDUCTION:.......: Reduction Hollow Shaft Gear OUTPUT SHAFT SPEED:........................9 RPM DOOR SPEED:............Variable, depending on door type. UTCH:..............................Slipping Clutch SAFETY DISCONNECT:.....Floor level clutch disconnect with electrical interlock for emergency manual door operation UTCH:......................Adjustable Slipping Clutch REVERSING EDGE (Optional):.. Electric or pneumatic sensing device attached to the bottom edge of door. ERATOR DIMENSIONS HP / / PHASE DIMENSION " -/".0".".6".6".6".6" Dia. Hole ( Places).9" 9." See Chart 9.9".".7".7" Mounting Dimensions.76"

PREPARATION It is imperative that the wall or mounting surface provide adequate support for the operator. This surface must: a. Be rigid to prevent play between operator and door shaft. b. Provide a level base. c. Permit the operator to be fastened securely and with the drive shaft parallel to the door shaft. The safety and wear of the operator will be adversely affected if any of the above requirements are not met. To prevent possible SERIOUS INJURY or DEATH: DO NOT connect electric power until instructed to do so. If the door lock needs to remain functional, install an interlock switch. ALWAYS call a trained professional door serviceman if door binds, sticks or is out of balance. An unbalanced door may not reverse when required. NEVER try to loosen, move or adjust doors, door springs, cables, pulleys, brackets or their hardware, ALL of which are under EXTREME tension and can cause SERIOUS PERSONAL INJURY. Disable ALL locks and remove ALL ropes connected to door BEFORE installing and operating door operator to avoid entanglement. INSTALLATION TYPICAL HOLLOW SHAFT. Slide the shaft collar provided over the door shaft to desired position and secure in place.. Slide the operator on the door shaft until it is laying against the shaft collar. Insert the -/" key provided into the operator and the door shaft.. Slide the second shaft collar on the door shaft until it is laying against the operator and secure in place, this will hold the -/" key in place.. Secure mounting bracket to wall (pad out as necessary). TIONAL THROUGH-SHAFT. Slide the through shaft provided into the operator to desired position. Insert the -/" key provided into the operator and the door shaft.. Install a shaft collar onto each end of the through shaft until they are laying against the operator and secure in place, this will hold the -/" key in place.. Install the tooth sprocket onto the though shaft with the -/" key provided.. Install the door sprocket provided to the door shaft. Connect the operator to the door with chain provided.. Secure mounting bracket to wall (pad out as necessary). Shaft Collar Door Shaft -/" Key Tooth Sprocket Shaft Collar Shaft Collar Through Shaft Shaft Collar -/" Key -/" Key

ENTRAPMENT PROTECTION ACCESSORIES (TIONAL) PHOTO EYES & SENSING EDGES Sensing devices provided for door industry type operators with an isolated normally open (N.O.) dry contact output are compatible with your operator. This includes pneumatic and electric edges, and through beam and retro reflective photo eyes. If you would like to order or receive more information on safety devices, please contact your local Authorized Dealer. If not pre-installed by the door manufacturer, mount the sensing edge on the door according to the instructions provided with the edge. The sensing edge may be electrically connected by either coiled cord or take-up reel. Important Notes: a. Proceed with Limit Switch Adjustments described below before making any sensing edge wiring connections to operator. b. Electrician must hardwire the junction box to the operator electrical box in accordance with local codes. WIRING For wiring of your sensing device to the operator, refer to the wiring diagram provided with your operator. See field connection terminals identified as Sensing Device or Safety Edge. TAKE-UP REEL: Take-up reel should be installed " (0. cm) above the top of the door. COIL CORD: Connect operator end of coil cord to junction box (not provided) fastened to the wall approximately halfway up the door opening. ADJUSTMENT LIMIT ADJUSTMENT CAUTION Disconnect power to operator before any adjustments. The limit switches will stop the door at each end of travel. Additional limit switches can be used for control of other automatic functions. To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect electric power BEFORE manually moving limit nuts. LIMIT SWITCH ADJUSTMENT NOTE: Before stating adjustment of the limit switches, loosen or tighten (if necessary) the lock nut in order to obtain a convenient adjustment tightness of the cam wheels. After finishing the adjustments, make sure that the lock nut is sufficiently tight to retain the cam wheels securely during operation. When door is in the fully open position, the green cam wheel (Open) will be turned into contact with its corresponding switch. In the same way, just before the door is in the closed position, the black cam wheel (Closed) will activate its switch. COARSE ADJUSTMENT The coarse adjustment of the limit switches can be done by inserting a rod or a screw driver into one of the adjustment holes in the cam wheels and by turning each cam wheel with the rod or screw driver. FINE ADJUSTMENT Fine adjustment can be done by screwing the adjustment screw (provided) against the cam shaft thread inside each cam wheel. The screw must be changed from one adjustment hole into the other for turning the cam wheel in the opposite direction. Lock Nut Auxilliary Limit Switches Adjustment Screw Close Limit (Black) Open Limit (Green) LIMIT BOX ON POWERHEAD Fine Adjustment Coarse Adjustment CCW CW

SLIPPING UTCH ADJUSTMENT The torque transmitted by the drive unit must always be adjusted in due consideration of the safety requirements of the door operation. The limitation of the torque is done by adjusting the slipping clutch situated between the electric motor and the gear box. When delivered from the factory the slipping clutch is left loose so that no torque can be transmitted from the electric motor. To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the -button control station is out of sight of the door or any other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. IMPORTANT: Before starting to adjust the slipping clutch, check and make sure that the door can easily be moved manually in every part of its travel.. Loosen the lock nut at the end of the worm shaft.. Hold the worm shaft with a spanner.. Start turning the adjustment screws inward (= clockwise) until the required torque has been obtained. The torque should be adjusted so that it is just high enough to move the door over its complete travel and low enough to permit the clutch to slip as soon as the door is obstructed in its movement. A direct safety risk is produced if the torque is set to a considerably higher level than required for the door operation. Clutch Lining Worm Shaft Lock Nut Adjustment Screw 6

INC. POWER WIRING CONNECTIONS To reduce the risk of SEVERE INJURY or DEATH: ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. The operator should be on a separate fused line of adequate capacity. ALL electrical connections MUST be made by a qualified individual. DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an optional reversing edge BEFORE proceeding with the control station installation. ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled. ALL power and control wiring MUST be run in separate conduit. ALL electrical connections MUST be made using liquid tight fittings. POWER WIRING. Do not turn power on until you have finished making all power and control wiring connections and have completed the limit switch adjustment procedure.. Remove the cover from the wall mounted starter. Inside this enclosure you will find the wiring diagram(s) for your unit. Refer to the wiring diagrams for all connections described below. If this diagram is missing, call the number on the back of this manual.. Be sure that the power supply is of the correct voltage, phase, frequency, and amperage to supply the operator. Refer to the operator nameplate on the cover. IMPORTANT NOTE: For best protection against the environment follow directions below for required specifications for power and control wiring connections. CONDUIT & FITTING PREPARATION The most efficient assembly of a liquid tight conduit and fitting system can be achieved, and optimum performance ensured, by adherence to simple conduit preparation and assembly techniques:. Square off ends of conduit by cutting the end of the conduit squarely using a hacksaw or similar tool, conduit manufacturers sometimes offer cutting jigs for this purpose.. Insert conduit flush with the fitting end stop.. Secure conduit to fitting. A compression gland nut, when provided as part of a fitting, will typically achieve maximum securement.. Ensure conduit jacket is not cut or ripped in any location along its surface. NOTE: For conduit preparation, always follow the conduit manufacturer s instructions. CONDUIT & FITTINGS Liquid tight Flexible Non-metalics Conduit (LFNC) is required for use in both exposed and concealed areas and for electrical systems that require flexibility and protection from vapors, liquids or solids. LFNC conduit should be used for liquid tight environment as stated by NEMA guidelines. All conduit and conduit fittings should be marked as Liquid Tight conduit and fittings marked Rain Tight or Wet Locations are not to be automatically considered liquid tight. NOTE: Select all conduit and conduit connectors based on local code and application of job. ATTACHMENT TO ENOSURE. Select proper fitting entry hole to be placed in enclosure and punch through using drill or tool.. Slide threaded body into fitting hole in enclosure,. Insert gasket around threaded area and secure in place with nut provided. (Refer to manufacturer specifications for proper torque requirements.). Remove all resulting debris created by entry hole(s) otherwise electrical components and operation may be affected. THE CHAMBERLAIN GROUP, ELMHURST, ILLINOIS 606 Do Not Run Power & Control Wiring in the Same Conduit PLACE RATING LABEL HERE B6 LISTED DOOR ERATOR 7

INC. CONTROL WIRING DETERMINE WIRING TYPE Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring. WIRING TYPES Standard C or B Wiring Standard operators are shipped from the factory with jumper set for C wiring, which requires constant pressure on button to close the door. If momentary contact on close direction is desired (B wiring) you must include an entrapment protection device. See close control jumper setting below. Constant pressure on close (C wiring) Red jumper wire was placed on terminal # in electrical enclosure. The operator will require constant pressure on close control in order to keep door moving in the close direction. SPECIAL CONTROL WIRING If your operator was shipped from the factory with non-standard control wiring or with optional accessories that require addition instructions, refer to the wiring diagram(s) indicated in the special control wiring data box. When a replacement wiring diagram is present, wiring diagrams in this manual will not apply. Refer only to the replacement wiring diagram for all connections. IMPORTANT NOTE: If your wiring diagram is missing, or you are unsure of the wiring type for your operator, contact technical support @ -00--06 or www.liftmaster.com. Momentary contact on close (B wiring) Move red jumper wire from terminal # to terminal #. The operator will require only momentary contact to close the door. LOCATING THE CONTROL STATION All operators are provided with a -Button Station (EN/OSE/ST) incorporated into the wall mounted starter.. Mount the wall mounted starter where the door is visible, but away from the door and its hardware.. Mount NOTICE beside or below the wall mounted starter.. Mount control station(s) within line on sight of door(s). To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the -button control station is out of sight of the door or ANY other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. THE CHAMBERLAIN GROUP, ELMHURST, ILLINOIS 606 PLACE RATING LABEL HERE B6 LISTED DOOR ERATOR N TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS EAR Notice

CONTROL WIRING RADIO CONTROLS On all models with type B control wiring, a terminal block marked R R R is located on the inside of the wall connected starter. Standard radio control receivers (single channel residential type) may be connected to this terminal block. The operator will then open a fully closed door, close a fully open door, and reverse a closing door from the remote control. However, for complete door control from a remote control, a commercial three-channel radio set (with connections for EN/OSE/ST) is recommended. DO NOT use radio controls with your operator unless you have installed some type of entrapment protection device. The use of radio controls presents potential hazards due to the user s ability to open or close the door when out of sight of the door. In addition, if a single channel control is used, the user will not be able to stop the door from the transmitter. ADDITIONAL ACCESS CONTROL EQUIPMENT Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the field wiring connections diagram. Any control with a normally (N.O.) isolated output contact may be connected in parallel with the EN button. More than one device may be connected in this manner. Use 6 gauge wire or larger for all controls. Do not use the control circuit transformer (Vac) in the operator to power any access control equipment other than a standard residential type radio receiver. EXTERNAL INTERLOCK SWITCH The operator has a terminal connection for an external interlock switch. This switch must be a normally closed (N.C.) two-wire device with a contact rating of at least amps @ VAC. When such a switch is connected as shown on the field wiring connections diagram, the control circuit will be disabled when the switch is actuated, thereby preventing electrical operation of the door from the control devices. TEST THE SYSTEM. Turn on power.. Test all controls and safety devices to make sure they are working properly. It will be necessary to refer back to page for fine adjustment of the limit switches. IMPORTANT NOTES: Do not leave operator power on unless all safety and entrapment protection devices have been tested and are working properly. Be sure you have read and understand all Safety Instructions included in this manual. Be sure the owner or person(s) responsible for operation of the door have read and understand the Safety Instructions, know how to electrically operate the door in a safe manner, and know how to use the manual disconnect operation of the door operating system. To prevent possible SERIOUS INJURY or DEATH, install reversing sensors when the -Button Control Station is out of sight of the door or any other control (automatic or manual) is used. Reversing devices are recommended for ALL installations. 9

PHASE SCHEMATIC DIAGRAM 0- T T T T GY BL YE PU T T T T GY BL YE PU POWER IN PHASE L L (BK) VOLT - PHASE MOTOR CONNECTION (BK) (WH) IR OVERLOAD (BK) (BK) 6 0 VOLT - PHASE MOTOR CONNECTION (GY) (BL) T T T TO MOTOR (SEE NOTE #) 0V MODELS V MODELS (GY) T (WH) (BK) 6 7 7 (GY) 7 7 (GY) - (BR) (BL) EXTERNAL (BL) ST INTERLOCK (BL) EN SAFETY EDGE R R EN & OSE RADIO TO EN & OSE OSE R 7 0 C PRI. NOTE. IR RELAY COIL VOLTAGE IS THE SAME AS POWER IN (WIRED N.O. HELD OSED WHEN MOTOR IS NOT RUNNING). * (BL) AUXILIARY OSE LIMIT SWITCH 7 C NC (YELLOW) OSE CONTROL WIRING TIONS C WIRING - Constant Presssure to Close RED WIRE ON TERMINAL # (Shipped from Factory) B WIRING - Momentary Contact to Close MOVE RED WIRE FROM TERMINAL # TO TERMINAL # * - Shipped from Factory TERMINAL IN WALL STARTERS TERMINAL IN ERATOR POWER HEAD INTERNAL INTERLOCK 6 NC NO (BK) AUX. EN LIMIT SWITCH (RED) IR IR H TD R 6 6 VAC SEC. EN LIMIT SWITCH C NC (GREEN) VAC DPDT 6 6 0V PRIMARY V PRIMARY H H H H H H H (WH) (BK) TD X X X 9 A A OSE LIMIT SWITCH C R NC A A (BLACK) VDC PDT WITH -/ SEC. DELAY TD TD V DC DPDT WITH. SEC DELAY A (WH) (WH) 6 + (WH) (BL) X TD- TD- R 0

PHASE FIELD CONNECTION DIAGRAM IMPORTANT NOTES:. If a ST button is not used, a jumper must be placed between terminals and.. Auxiliary control equipment may be any normally open two wire device such as pullswitch, single button, loop detector, card key or such device.. Attention Electrician: Use 6 gauge or heavier wire for all control circuit wiring. WALL MOUNTED STARTER POWERHEAD LIMIT BOX SEPERATE BUTTON STATION OTHER THAN ONE SUPPLIED ON WALL MOUNTED STARTER EN ST ON WALL MOUNTED STARTER OSE (RED) AUXILIARY EN LIMIT SWITCH RED WIRE ORIGINALLY WENT TO TERMINAL IN STARTER ST REMOVE JUMPER IF EXTERNAL SWITCH IS USED EXTERNAL INTERLOCK 6 EN & OSE 6 7 (GREEN) EN LIMIT SWITCH SAFETY EDGE 9 0 7 (YELLOW) (BLACK) AUXILIARY OSE LIMIT SWITCH OSE LIMIT SWITCH INTERNAL INTERLOCK SWITCH RADIO RECEIVER R R R PHASE POWER IN T T T T L L L MOTOR (SEE SCHEMATIC) GROUND

T T T PHASE SCHEMATIC DIAGRAM BRN GY PUR YEL BRN 7 0 VOLT - PHASE MOTOR CONNECTION 9 6 OVERLOAD (WHEN SUPPLIED) T T T BRN GY PUR YEL BRN 7 60 VOLT - PHASE MOTOR CONNECTION 9 6 OVERLOAD (WHEN SUPPLIED) 0- L (BK) (GY) T POWER IN PHASE L (BK) 6 T TO MOTOR L PRI. (BK) (BR) (BR) 6 T 7 7 (GY) 7 7 (GY) - (BR) H 6 6 6 6 + 60V PRIMARY 0V PRIMARY H H H H H H H (BR) (BR) (BR) (BL) (BR) (BL) EXTERNAL INTERNAL (BL) ST INTERLOCK INTERLOCK 6 (BL) (BL) EN SAFETY EDGE EN & OSE 0 RADIO TO EN & OSE R R R OSE 7 AUXILIARY OSE LIMIT SWITCH 7 C NC (YELLOW) NC AUX. EN C LIMIT SWITCH (RED) NO TD OSE CONTROL WIRING TIONS * C WIRING - Constant Presssure to Close RED WIRE ON TERMINAL # (Shipped from Factory) B WIRING - Momentary Contact to Close MOVE RED WIRE FROM TERMINAL # TO TERMINAL # MOTOR OVERLOAD OR OVERLOAD PILOT (BR) (BR) (BR) TD R VAC SEC. EN LIMIT SWITCH C NC (GREEN) VAC DPDT OSE LIMIT SWITCH C NC (BLACK) 9 A A A X (WH) X TD- TD- R R A A 6 * - Shipped from Factory VDC PDT WITH -/ SEC. DELAY TD (WH) TERMINAL IN WALL STARTERS TERMINAL IN ERATOR POWER HEAD TD V DC DPDT WITH. SEC DELAY

PHASE FIELD CONNECTION DIAGRAM IMPORTANT NOTES:. If a ST button is not used, a jumper must be placed between terminals and.. Auxiliary control equipment may be any normally open two wire device such as pullswitch, single button, loop detector, card key or such device.. Attention Electrician: Use 6 gauge or heavier wire for all control circuit wiring. WALL MOUNTED STARTER POWERHEAD LIMIT BOX SEPERATE BUTTON STATION OTHER THAN ONE SUPPLIED ON WALL MOUNTED STARTER EN ST ON WALL MOUNTED STARTER OSE (RED) AUXILIARY EN LIMIT SWITCH RED WIRE ORIGINALLY WENT TO TERMINAL IN STARTER ST REMOVE JUMPER IF EXTERNAL SWITCH IS USED EXTERNAL INTERLOCK 6 EN & OSE 6 7 (GREEN) EN LIMIT SWITCH SAFETY EDGE 9 0 7 (YELLOW) (BLACK) AUXILIARY OSE LIMIT SWITCH OSE LIMIT SWITCH INTERNAL INTERLOCK SWITCH RADIO RECEIVER R R R PHASE POWER IN T T T T L L L MOTOR (SEE SCHEMATIC) GROUND

G ERATION AND MAINTENANCE ENT To reduce the risk of SEVERE INJURY or DEATH: ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. The operator should be on a separate fused line of adequate capacity. MANUAL DISCONNECT By turning the disengagement lever the gear unit can be disconnected from electric operation in order to permit manual operation of the door. For operating the lever from above floor level, attack a rope or a chain in the holes at the ends of the lever. The movement of the lever acts upon a safety micro switch, which will keep the control current disconnected until the lever has been turned absolutely perfectly into its position for normal electric operation of the door. ALL electrical connections MUST be made by a qualified individual. DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that you install an optional reversing edge BEFORE proceeding with the control station installation. ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled. ALL power and control wiring MUST be run in separate conduit. AVERTISSEMENT AVERTISSEMENT Disengagement Lever To Engage Pull Handle CIA N ADVERTENCIA ADVERTENCIA To Disengage Pull Handle

Check at the intervals listed in the following chart. MAINTENANCE SCHEDULE To avoid SERIOUS PERSONAL INJURY or DEATH from electrocution, disconnect ALL electric power BEFORE performing ANY maintenance. EVERY EVERY EVERY ITEM PROCEDURE MONTHS 6 MONTHS MONTHS Drive Chain Check for excessive slack. Check & adjust as required. Lubricate.* Sprockets Check set screw tightness Fasteners Check & tighten as required Manual Disconnect Check & Operate Bearings & Shafts Check for wear & lubricate Use SAE 0 Oil (Never use grease or silicone spray). Do not lubricate motor. Motor bearings are rated for continuous operation. Do not lubricate clutch or V-belt. Repeat ALL procedures. Inspect and service whenever a malfunction is observed or suspected. HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA Installation and service information are available. Call our TOLL FREE number: -00--06 WHEN ORDERING REPAIR PARTS PLEASE SUPPLY THE FOLLOWING INFORMATION: PART NUMBER DESCRIPTION MODEL NUMBER ADDRESS ORDER TO: THE CHAMBERLAIN GROUP, INC. Technical Support Center 600 S. Country Club Tucson, AZ 706

REPAIR PARTS KITS WALL MOUNTED STARTER Below are replacement kits available for your operator. For replacement of wall mounted starter and or motor kit be sure to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or accessories included with your operator may add or remove certain components from these lists. Please consult a parts and service representative regarding availability of individual components of kits specified below. Refer to page for all repair part ordering information. Complete Electrical Box Replacement Kits To order a complete electrical box replacement kit, add a K- prefix to the model number of your operator. For example: EGJ0M (Operator) = K-EGJ0M (Elec. Box Kit) Motor Kits 0-00CT 0-00C-T 0-00CT Models EGJ0M & EGJ0M Model EGJ0M Models EGJ0M & EGJ0M * COMPLETE ELECTRICAL BOX KITS ITEM PART # DESCRIPTION 0-0K Contactor 0-9 Panel, EGJ Transformer -7 /0V Phase -760 0/60V Phase -- Relay, R --0 Relay, TD 6-6- Relay, TD 7 Relay, I. R. -- V -0-0V Single Phase Overload -006 6 Amp/0V -00 0 Amp/V 9 7-00-K Contact Block 0 9- Bridge Rectifier 0-00-E Black Button 0-0-E Black Boot 0-00-E Red Button 0-0-E Red Boot -0 0 Pole Terminal Block 6 - Pole Terminal Block 7-0-XH Enclosure 7-0-0 Fuse Holder 9 9-ABC- A Fuse NOT SHOWN K7-606 (TD). Second Time Delay Resistor K7-7 (TD) 0. Second Time Delay Resistor 6

ILLUSTRATED PARTS WALL MOUNTED STARTER 9 9 0 7 6 6 7 7

REPAIR PARTS KITS MODEL EGJ (TYPICAL HOLLOW SHAFT) Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or remove from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page for all repair part ordering information. 6 7 INDIVIDUAL PARTS ITEM PART # DESCRIPTION 0-9097 Mounting Bracket -06 Shaft Collar 9-0 Pull Cord 0-07 Pull Switch Handle 0-7 Key, /"x-/" 6 TVR-- Limit Gear Reducer 7 Motor - 0-00C-T Models EGJ0M & EGJ0M 0-00C-T Models EGJ0M & EGJ0M 0-00C-T Model EGJ0M, Wall Mounted Starter NOT SHOWN K7-7 Clutch Kit EGJ K7-7 Housing Service Kit EGJ K7-77 Cam EGJ Service Kit K7-76 Limit/Terminal Block EGJ 9-679 Clutch Pad

ILLUSTRATED PARTS MODEL EGJ (TIONAL THROUGH SHAFT) Refer to the parts lists below for replacement kits available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or remove from these lists. Individual components of each kit may not be available. Please consult a parts and service representative regarding availability of individual components. Refer to page for all repair part ordering information. T 6 T T 7 INDIVIDUAL PARTS ITEM PART # DESCRIPTION 0-9097 Mounting Bracket -06 Shaft Collar 9-0 Pull Cord 0-07 Pull Switch Handle 0-7 Key, /"x-/" 6 TVR-- Limit Gear Reducer 7 Motor - 0-00C-T Models EGJ0M, EGJ0M 0-00C-T Models EGJ0M, EGJ0M 0-00C-T Model EGJ0M Wall Mounted Starter THROUGH SHAFT KIT, 7-76 ITEM PART # DESCRIPTION T -77 Through Shaft T -0BLGH Sprocket, 0B " Bore T 0-07-9 Key, /"x-/" NOT SHOWN 9-006MN Chain #0 Nickel Plated NOT SHOWN K7-7 Clutch Kit EGJ K7-7 Housing Service Kit EGJ K7-77 Cam EGJ Service Kit K7-76 Limit/Terminal Block EGJ 9-679 Clutch Pad 9

007, The Chamberlain Group, Inc. 0-0E All Rights Reserved