MCset kv Medium voltage equipment

Similar documents
Medium Voltage Distribution Maintenance Guide I 2013 Premset. 15 kv compact modular vacuum switchgear with Shielded Solid Insulation System

24 kv. A brief summary of the. range

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

SM6. instructions for use. DMVL cubicle. MV distribution factory built assemblies at your service. Anglais

SM6. instructions for use. IMB cubicle without earthing switch. MV distribution factory built assemblies at your service. Anglais

SM6. instructions for use. SM cubicle. MV distribution factory built assemblies at your service. Anglais

SM6. instructions for use. GAM cubicle (1250A) MV distribution factory built assemblies at your service. Anglais

UniSec Maintenance solutions

MCset 4-24 kv Withdrawable SF6 circuit breaker

NEX - 24 kv Withdrawable Circuit Breaker

I B D Q I B D Q O I B D Q O

CBGS-0. Medium voltage distribution

MCset 17.5 kv. Civil engineering guide April Medium Voltage Distribution

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Information for the modified document

Medium Voltage Distribution FBX. Assembling a 1250A busbar Instructions.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

0MV vacuum circuit breaker. 0Evolis 24 kv. 0User 0Manual. Creation Printed on 2008/07/17

SM6. instructions for use. QMB cubicles. MV distribution factory built assemblies at your service. Anglais

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

PIX-H Metal-clad switchgear up to 17.5kV

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Vacuum Circuit-Breakers, Type HVX kv, of cassette design, cassette with motor drive

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Compact NR630. NR100F to NR630F

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Masterpact MTZ Circuit Breakers and Switch-Disconnectors Maintenance Guide

Evolis offer Merlin Gerin

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

NXPLUS C Single busbar. Maintenance-free for lifetime

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

1. Inspection and Maintenance

circuit breaker instructions for use SF draw --- out circuit---breakers in F400 MV distribution circuit breaker Anglais at your service

Power Break Circuit Breakers

Fuse contactor drawer CVX for PIX Switchgear (12kV)

3946 en / a. This manual is to be given to. the end user. HPM x44. A.C. motor. Installation and maintenance

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Switchgear Delta H2000 Medium voltage switchgear for primary distribution

Air-insulated switchgear UniGear type ZS1

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SM6. instructions for use. DMV S cubicle. MV distribution factory built assemblies at your service. Anglais

Protection and control VIP30, VIP35. Relays technical manual

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

8DJ. Maintenance-free for lifetime

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

SM6. instructions for use. DM1 S cubicle. MV distribution factory built assemblies at your service. Anglais

Secondary Distribution Switchgear FBX. SF6 Gas-insulated switchboards CB function. Instructions Installation - Commissioning Operating - Maintenance

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker

SM6. instructions for use. DMV A---DMV D cubicle (1250A range) MV distribution factory built assemblies at your service. Anglais

SM6. instructions for use. IMCandQMCcubicles. MV distribution factory built assemblies at your service. Anglais

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

STANDARDIZED LOW VOLTAGE SWITCHBOARDS UP TO 690V-6300A-100KA

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Fuse switch disconnectors

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

UniGear. Technical Guide

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

Instruction manual. EK6 Earthing switch 36/40.5 kv

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

Energy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1.

TeSys Enclosed Starters. Let TeSys watch over your machinery

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

Metal Clad Switchgears

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

VD4 Installation and service instructions kv A ka

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

DX³ RCCBs - ID 4P up to 100 A

UniSec Operation and maintenance manual

Secondary Distribution Switchgear FBX. SF6 Gas-insulated switchboards. Instructions Operation - Maintenance

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

Power systems Protection course

1. Safety practices General Introduction Standards...3

Current sensor. Instructions for installation, use and maintenance. Type KECR 17,5 AC1 ABB

McCANNA Actuation Systems B

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Galaxy VM. Battery Breaker Box Installation 09/

Appendix: Safety and application notes for... 15

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Motor management system TeSys T Give your motor starters a sixth sense!

EISHO TEK. Vacuum Circuit Breaker

Gas Insulated Metal-clad Switchgear, HMGS!

Transcription:

Maintenance Guide PE90014 PE90006 MCset 1-2 - 3 17.5 kv Medium voltage equipment Air-insulated switchboards Metal-enclosed switchgear with moving parts PE90007 PE90008 PE90009

PE90007

Maintenance Guide PE90014 PE90006 Contents General Operations to be performed Control mechanisms Vents and insulating materials Power circuits Auxiliary circuits Recommended frequency Normal operating conditions Operating conditions in a corrosive atmosphere Operating conditions for naval use 2 3 4 5 6 7 8 10 12 1

General Warning Preventive maintenance operations must be carried out regularly on medium-voltage equipment. PE90008 Technicians trained to work on this type of equipment are required. Two skills are essential: - electrical qualifications - knowledge of the equipment to be maintained. This document does not apply to moving parts and protection relays (1). Please refer to the maintenance documents specific to each type of switchgear used. If necessary, you can also contact your Product, Country, Services agent. (1) moving parts (circuit breaker, contactor) and protection relays (SEPAM) Electrical qualifications Only employees with appropriate electrical qualifications will be allowed to carry out these maintenance operations. 2

PE90006 Intervention level Different skill levels have been established to define the persons who are capable of working on medium-voltage equipment: Level 1 Regular maintenance. The maintenance operations to be carried out on the equipment are generally described in the instruction handbook. Minor preventive maintenance operations not requiring disassembly and standard repairs that require one part to be replaced with another provided for this purpose, performed by an operator s accredited technician according to the manufacturer s maintenance instructions. Level 2 Operations requiring simple procedures and/or support equipment (integrated into devices or external) that is easy to use and implement. Level 3 Preventive maintenance operations, such as general adjustment, identification and troubleshooting, repairs requiring the replacement of one component or functional unit with another or minor mechanical repairs, carried out by a specialised technician using the tools, adjusting and measuring instruments specified in the manufacturer s maintenance instructions. Level 4 Operations whose procedures involve knowledge of a particular technique or technology and/or how to use specialised support equipment. All important corrective or preventive maintenance operations carried out by the manufacturer s after-sales services. Operations that may affect switchgear performance. Level 5 Operations whose procedures involve know-how, requiring the use of particular techniques or technologies, industrial processes or support equipment. Equipment will generally have to be returned to the factory; this applies only to moving parts. Training Schneider Electric offers a wide choice of training courses on operating or maintaining its equipment. Level 3-4-5 operations require training on the equipment. Training programme This training is delivered in our training centres by Schneider Electric s accredited skilled staff. 3

Operations to be performed DE90035 (the equipment must be switched off) DE90036 (do not walk on the parts, assemblies and areas identified by this pictogram) P1010015 Control mechanisms Dust, impacts, aggressive atmosphere, insufficient or excessive lubrication may adversely affect the mechanical operation of a device. Safe operation will be maintained by removing dust / general cleaning, appropriate lubrication and regular use of the device. The operations described below apply to flap control mechanisms, earthing switch and rack-out voltage transformer control rods, moving part guide rails and pins of connecting rods operating auxiliary position contacts. PE90012 P1010015 1 2 3 1 - Medium voltage compartment flap control 2 - Voltage transformer extraction truck 3 - Rack-out circuit-breaker guide rails P1010003 Dust removal An extractor must be used for this operation. Do not use compressed air for this cleaning operation. Cleaning - Degreasing A completely clean dry cloth or brush free from any kind of solvent must be used for this operation. High-pressure spraying of products containing solvents (trichloroethane, trichloroethylene) is strictly prohibited. The main disadvantages of such spraying may be: - impossibility of reapplying grease to inaccessible lubrication points (greased for life), - corrosion or clamping of non-regreased areas, - deterioration due to the pressure of the jet, regreased areas, - deterioration due to the pressure of the jet, - risk of overheating due to the presence of insulating solvent on the contact areas, - removal of special protection, - deterioration of plastics. Lubrication This operation is carried out after certain mechanical joints, such as those described in the maintenance procedures, have been cleaned. Greases recommended by Schneider Electric must be used. Never apply too much grease, because excessive greasing combined with dust can cause the mechanism to malfunction. Grease must never be applied to insulating parts. Operation The necessity for an installation to run continuously generally means that the power devices are seldom operated. Although the ageing process of a device may be accelerated if it is used too frequently, mechanical malfunctions may occur if it is not operated for a long period of time. Regular operation is necessary to maintain the original performance of each operating unit. Interlocking with keys or padlocks must be fully tested to check that they are working correctly. 4

P1010010 PE90011 PE90011 1 2 Vents and insulating materials Dust deposited in various parts of the cubicle may adversely affect the electrical operation of a medium voltage device. Too much dust on insulating materials may generate partial discharges that may ultimately cause dielectric flashover or internal arcing. The air vents must also be cleaned to help the air to circulate in the cubicle and avoid overheating. In all cases, the cubicle must be thoroughly cleaned, especially the bottom of the cubicle. Dust removal Insulating materials An extractor must be used for this operation, as for the control mechanisms. For parts that are difficult to access, use a dry cloth, taking care not to accumulate any dust on the insulating material. During this operation, check that there is no foreign matter, corona or partial discharge, indicated by a change of colour or degradation of the insulating material. Air vents An extractor must be used for this operation. Natural ventilation is required for the cubicles. This cleaning is mandatory for versions with forced ventilation (fans mounted on the top of the cubicle). The frequency of these operations depends on the environmental and operating conditions. 1 - Insulator supports 2 - Air vents 5

Operations to be performed PE90013 Power circuits The connections between the various switchboard distribution systems (busbars, cables) and the switchgear are an important source of heat dissipation. Any tightening that does not conform to the recommendations can cause a thermal runaway resulting in a degradation of the device, insulating materials and cables, which may degenerate into a short circuit and/or fire. This type of malfunction is often due to the nonobservation of the installation specifications when the switchboards are installed. Sliding connections (rack in) They consist of two parts: clip and rack-in connector. This type of connection requires appropriate regular cleaning in accordance with the procedures described. The grease makes it easier to connect the clips and rack-in connectors and prevents damage to the silvered surface by reducing the rack-in force. In the case of a sulphiding corrosive atmosphere (H2S / SO2), the indications specific to each range must be complied with. Special greases can be used to protect silver- and copper-plated contacts from sulphidation. Silver or copper sulphides reduce contact quality. They cause the contact resistance to increase, which leads to increased overheating. As grease deteriorates over time, it must be replaced regularly. PE90013 1 - Power connections 2 - Cable connection P1010026 1 2 Fixed connections (connection by lugs or busbars) This type of connection does not require special maintenance if it is carried out according to Schneider Electric s recommendations (torque, 8.8 screws and bolts and contact washer). Otherwise, regularly check the heating points (copper colour change / galvanisation) and remove the connection, polish the contact parts and reassemble them with new screws and bolts. Standard tightening torques (non-greased screws and bolts) The table below indicates the tightening torques for class 8.8 screws and bolts with contact washer and nut. Screw Torque in Nm ø 6 13 ø 8 28 ø 10 50 ø 12 75 ø 14 120 6

P1010020 P1010020 Low voltage compartment Low voltage auxiliary circuits Auxiliary wiring It is used to transmit orders to the various control units of the device and retrieve its states. A degraded connection or insulating material may prevent the device from operating or cause unwanted tripping. Auxiliary wiring must be checked and replaced at regular intervals, if necessary, especially in the event of vibrations, a high ambient temperature or corrosive atmospheres. Signalling contacts The contacts indicating the position of the circuit breaker, earthing switch, voltage transformer truck and ready-to-operate circuit breaker allow the operator to view the states and to act accordingly. Any incorrect signalling can lead to device control errors that may endanger the operators. Contact failure (worn contacts, loose terminals) may be the result of vibrations, corrosion or abnormal overheating; preventive maintenance must ensure good continuity (or non-continuity) of the contact in the different states. Protection relay An electrical fault on the installation is detected by the relay which orders the circuit breaker to open in order to ensure that the equipment and operators are protected. Electronic components and cards are sensitive to the environment (ambient temperature, humid and corrosive atmosphere) and to harsh operating conditions (magnetic fields, vibrations, etc.). To ensure safe operation, the following must be checked at regular intervals: - the tripping chain, - the intervention times according to fault current levels. Refer to the documents specific to the protection relay used. 7

Recommended frequency Normal operating conditions PE90010 The maintenance programme must be carried out on the cubicles as soon as they are commissioned and then every five years at most; the maintenance operator must have the required skill level (see the description in the table below). These operations are applicable for the environmental and operating conditions that meet the normal service conditions, in accordance with IEC 60694 for indoor switchgear. Ambient air temperature - less than or equal to 40 C, - less than or equal to 35 C, on average over 24 hours, - greater than or equal to 5 C. Altitude - less than or equal to 1000 m, - above 1000 m, a derating coefficient will be applied (please consult us). Ambience - no dust, smoke, salt, corrosive or flammable gas and vapour (clean industrial air). Humidity - average relative humidity over 24 hours < 95%, - average relative humidity over 1 month < 90%, - average vapour pressure over 24 hours < 2.2 kpa, - average vapour pressure over 1 month < 1.8 kpa. 8

PE90006 Check Frequency Tools - Products Intervention Power down Approximate Reference (year) level intervention document time Switchgear COM* 5 Cubicle Switchboard Visually check the general condition of the cubicle (front panel, control unit, box, frame) Check the voltage transformer fuses (if necessary, replace the three fuses at the same time) Check the fuses in the feeder cubicles fitted with fused switches (if necessary, replace the three fuses at the same time) Check the fuses in the feeder cubicles fitted with fused contactors (if necessary, replace the three fuses at the same time) - - 1 - - 15 min - Multimeter (2) 2-3 - - 1h 30 min - Multimeter (2) 2-3 - 1h 30 min 07897334 - Multimeter (2) 2-3 - 1h 30 min 07897409 Removable devices Remove and replace the circuit breaker or contactor Remove and replace the voltage transformer frame Check the operation of the position contacts - Removable racked-in or racked-out part - Earthing switch - Racked-out voltage transformer Replace the grease on the rack-in connectors - - 1 - - 15 min - - 1 - (1) 45 min - - 1 - - 30 min - - 1-30 min - - 1-30 min - Grease 1-1 h for electrical use Control mechanisms (p.4) Open / close the moving parts manually and electrically (refer to the switchgear-specific documents) Open / close the earthing switch manually Remove the dust and grease the earthing switch control Remove the dust and grease the flap control Remove the dust from the moving part guide rails Operate the key-operated interlocks Operate the rack-in inhibition mechanism Vents and insulating materials (p.5) Remove the dust from the air vents - Outside - Inside Remove the dust from the fans (on cubicles according to performance) Remove the dust from the insulating materials Power circuit (p.6) Check and retighten the connections, if necessary (busbars, CTs, earthing switch, cables) Control and signalling auxiliaries (p.7) - - 1-30 min - - 1 - (1) 1 h - Mobilith SCH100 3-4 - 1 h grease to be applied - to the moving parts 3-4 - 1 h - - 3-4 - 30 min - - 1-1 h - - 1-15 min - - 1 - - 30 min - - 3-4 - 30 min - - 3-4 - 1 h - - 3-4 - 3 h Calibrated 2-3 - 3 h torque wrench s 07897324 (3) (3) Check that the auxiliary wiring is uninterrupted and the appearance of the insulating material Check the tripping chain Ask for the thermal diagnosis system to be checked (refer to specific documents) - - 1-1h 30 min - - 1-1 h - Schneider Electric 4 - - 1 h checking tools * Commissioning - (1) ) Power down the cubicle according to its configuration in the switchboard (for example, the feeder cubicle) (2) To be selected according to the fuse ratings - (3) Removal procedure 9

Recommended frequency Operating conditions in a corrosive atmosphere PE90009 The maintenance programme must be carried out on the cubicles as soon as they are commissioned and then every three years at most; the maintenance operator must have the required skill level (see the description in the table below). These operations apply to the H2S specific MCset switchboard for the environmental and operating conditions specific to the conditions as defined. The operating conditions in certain fields of activity require the maintenance programme to be carried out under normal conditions to be complemented for the impact of atmospheric pollutants to be taken into account. Pollution: SO2 = sulphur dioxide, H2S = hydrogen sulphide. These types of atmospheric pollutants are mainly found in heavy industry, such as refineries, the iron and steel industry, paper mills, the petrochemical industry, etc. When these pollutants are combined with humidity, they are highly corrosive for the parts used in our equipment: - bare copper, silvering for electrical contacts, - control mechanisms. 10

PE90006 Check Frequency Tools - Products Intervention Power down Approximate Reference (year) level intervention document time Switchgear COM* 3 Cubicle Switchboard Visually check the general condition of the cubicle (front panel, control unit, box, frame) Check the voltage transformer fuses (if necessary, replace the three fuses at the same time) Check the fuses in the feeder cubicles fitted with fused switches (if necessary, replace the three fuses at the same time) Check the fuses in the feeder cubicles fitted with fused contactors (if necessary, replace the three fuses at the same time) Removable devices Remove and replace the circuit breaker or contactor Remove and replace the voltage transformer frame Check the operation of the position contacts - Removable racked-in or racked-out part - Earthing switch - Racked-out voltage transformer Replace the grease on the rack-in connectors - - 1 - - 15 min - Multimeter (2) 2-3 - - 1h 30 min - Multimeter (2) 2-3 - 1h 30 min 07897334 - Multimeter (2) 2-3 - 1h 30 min 07897409 - - 1 - - 15 min - - 1 - (1) 45 min - - 1 - - 30 min - - 1-30 min - - 1-30 min - Grease 1-1 h for electrical use Control mechanisms (p.4) Open / close the moving parts manually and electrically (refer to the switchgear-specific documents) Open / close the earthing switch manually Remove the dust and grease the earthing switch control Remove the dust and grease the flap control Remove the dust from the moving part guide rails Operate the key-operated interlocks Operate the rack-in inhibition mechanism Vents and insulating materials (p.5) Remove the dust from the air vents - Outside - Inside Remove the dust from the fans (on cubicles according to performance) Remove the dust from the insulating materials Power circuit (p.6) Check and retighten the connections, if necessary (busbars, CTs, earthing switch, cables) Control and signalling auxiliaries (p.7) - - 1-30 min - - 1 - (1) 1 h - Mobilith SCH100 grease to be applied 3-4 - 1 h - to the moving parts 3-4 - 1 h - - 3-4 - 30 min - - 1-1 h - - 1-15 min - - 1 - - 30 min - - 3-4 - 30 min - - 3-4 - 1 h - - 3-4 - 3 h Calibrated 2-3 - 3 h torque wrench s 07897324 (3) (3) Check that the auxiliary wiring is uninterrupted and the appearance of the insulating material Check the tripping chain Ask for the thermal diagnosis system to be checked (refer to specific documents) - - 1-1h 30 min - - 1-1 h - Schneider Electric 4 - - 1 h checking tools * Commissioning - (1) ) Power down the cubicle according to its configuration in the switchboard (for example, the feeder cubicle) (2) To be selected according to the fuse ratings - (3) Removal procedure 11 GUIDE DE MAINTENANCE

Recommended frequency Operating conditions for naval use PE90007 The maintenance programme must be carried out on the cubicles as soon as they are commissioned and then every two years at most; the maintenance operator must have the required skill level (see the description in the table below). These operations are applicable for the environmental and operating conditions specific to the military or merchant navy, as defined. PE90015 Ambient air temperature - less than or equal to 45 C, and greater than or equal to - 5 C. Vibrations (IEC 60068-2-6) - frequencies between 2 Hz and 13.2 Hz: 1 min, - frequencies between 13.2 Hz and 100 Hz: 0.7 g Humidity - average relative humidity over 24 hours: 96%, - average relative humidity over 1 month: 90%. 12

PE90006 Check Frequency Tools - Products Intervention Power down Approximate Reference (year) level intervention document time Switchgear COM* 2 Cubicle Switchboard Visually check the general condition of the cubicle (front panel, control unit, box, frame) Check the voltage transformer fuses (if necessary, replace the three fuses at the same time) Check the fuses in the feeder cubicles fitted with fused switches (if necessary, replace the three fuses at the same time) Check the fuses in the feeder cubicles fitted with fused contactors (if necessary, replace the three fuses at the same time) Removable devices Remove and replace the circuit breaker or contactor Remove and replace the voltage transformer frame Check the operation of the position contacts - Removable racked-in or racked-out part - Earthing switch - Racked-out voltage transformer Replace the grease on the rack-in connectors - - 1 - - 15 mn - Multimeter (2) 2-3 - - 1h 30 min - Multimeter (2) 2-3 - 1h 30 min 07897334 - Multimeter (2) 2-3 - 1h 30 min 07897409 - - 1 - - 15 min - - 1 - (1) 45 min - - 1 - - 30 min - - 1-30 min - - 1-30 min - Grease 1-1 h for electrical use Control mechanisms (p.4) Open / close the moving parts manually and electrically (refer to the switchgear-specific documents) Open / close the earthing switch manually Remove the dust and grease the earthing switch control Remove the dust and grease the flap control Remove the dust from the moving part guide rails Operate the key-operated interlocks Operate the rack-in inhibition mechanism Vents and insulating materials (p.5) Remove the dust from the air vents - Outside - Inside Remove the dust from the fans (on cubicles according to performance) Remove the dust from the insulating materials Power circuit (p.6) Check and retighten the connections, if necessary (busbars, CTs, earthing switch, cables) Control and signalling auxiliaries (p.7) - - 1-30 min - - 1 - (1) 1 h - 3-4 - 1 h Mobilith SCH100 - grease to be applied 3-4 - 1 h to the moving parts - 3-4 - 30 min - - 1-1 h - - 1-15 min - - 1 - - 30 min - - 3-4 - 30 min - - 3-4 - 1 h - - 3-4 - 3 h Calibrated 2-3 - 3 h torque wrench s 07897324 (3) (4) Check that the auxiliary wiring is uninterrupted and the appearance of the insulating material Check the tripping chain Ask for the thermal diagnosis system to be checked (refer to specific documents) - - 1-1h 30 min - - 1-1 h - Schneider Electric 4 - - 1 h checking tools * Commissioning - (1) ) Power down the cubicle according to its configuration in the switchboard (for example, the feeder cubicle) (2) To be selected according to the fuse ratings - (3) Removal procedure 13 GUIDE DE MAINTENANCE

PE90006 Maintenance Guide i s s u e 2OO7 PE90008 PE90009 PE90007 ART833121 Schneider Electric Industries SAS - All rights reserved Schneider Electric Industries SAS 89, boulevard Franklin Roosevelt F-92500 Rueil-Malmaison Cedex Tél : +33 (0)1 41 29 85 00 www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. This document has been printed on ecological paper. Publishing: SYNTHESE ECA, Schneider Electric. Printing: Imprimerie du Pont de Claix DEAI03EN 11/2007