Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

Similar documents
A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010

NETWORK CONNECTION STANDARD (Distribution Code)

Submission on the Wellington Town Belt Bill. Local Government and Environment Select Committee Parliament Buildings Wellington

Technical requirements for connections to Orion s electricity distribution network

Electricity Safety (Electrical Installations) Regulation 2005

Net +Plus Connection Code

Technical requirements for connections to Orion s electricity distribution network

NP 007 Service Rules

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Aurora Energy Limited. Network Connection Requirements (NS5.1)

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

Basic Connection Services Application and Price Guide

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

NZQA registered unit standard version 1 Page 1 of 6

is attached to and becomes a part of a agreement dated, 20,

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

Street Address. City-Village-Township

Guidelines when working near TasNetworks electrical assets

Electricity (Safety) Regulations 2010

SERVICE AND INSTALLATION RULES

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Street Address. City-Village-Township

Wilkins Safety Group

is attached to and becomes a part of a agreement dated, 20

Renewable Generation Electrical Infrastructure and Grid Connection Services Provided by Power Systems Project and Consultancy Services (PCS) Ltd

INTRODUCTION... 1 A GAS MEASUREMENT SYSTEM ( GMS ) PRICES... 2

Connecting your business diesel generation

Service & Installation Rules 2014

Engineering Recommendation P26

Connection Application

Construction and Connection of Street Light Assets

Research Brief. Impact of higher 25kV fault currents. T873 - October Background. Aims

De-Energisation - Frequently Asked Questions

ELECTRIC DIVISION RULES AND PROCEDURES FOR ELECTRIC SERVICE

Umatilla Electric Cooperative Net Metering Rules

Technical Standard - TS 129. Small Inverter Energy Systems (IES) - Capacity not exceeding 30kW. SA Power Networks. Published: November 2017

The cost estimation methodology used to update the charges and credits is the same methodology the Company utilized in the prior year s filing.

Louisville Gas and Electric Company

EARTHING YOUR QUESTIONS ANSWERED

UWA Electrical Safety Procedure

DISTRIBUTION BUSINESS DISTRIBUTION STANDARD: SERVICE AND INSTALLATION RULES DS-I-CA-01

Queensland Electricity Connection and Metering Manual

Service & Installation Rules

City of Westerville Electric Division

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

Electricity Safety (Installations) Regulations 2009

Commercial Plan Submittal Form Utility Service Requirements

ELECTRICIANS REGULATIONS EXAMINATION 29 June 2013 QUESTION AND ANSWER BOOKLET

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Low Voltage Power Supplies in Electrified Areas

EDS ELECTRIC VEHICLE CONNECTIONS

Operating procedures relating to the use of electrical equipment and installations

This page is purposely left blank

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

ELECTRIC POLICY INTRODUCTION CHAPTER I GENERAL

Company Directive STANDARD TECHNIQUE: SD4O/1. Standard HV Connection Arrangements

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

HEARING STATEMENT - PALMERSTON NORTH CITY COUNCIL PLAN CHANGE 15A - RURAL ZONE (GENERAL ISSUES)

NZQA registered unit standard version 1 Page 1 of 5. Apply and remove portable earths in an electricity supply system

M.P.S.C. No. 2 Electric Third Revised Sheet No. 65 (Rate Case) Cancels Second Revised Sheet No. 65

SERVICE & INSTALLATION RULES Manual No. 32

Code of Practice. For works on, near or adjacent to the Luas Tramway

List of exemptions from compliance with the Technical Rules granted by Western Power after 1 July 2007

Procedure PR D Electrical Permits. Engineering Procedure Electrical Distribution Unit. Version 1.0. Date in Force: 4 November 2015

Guidance for Low Voltage Electrical Installations

1. General Requirements

GENERAL INFORMATION 1.01 PURPOSE

Net Metering Interconnection Requirements

FAQ s. Designing metering switchboards as per Victorian service installation rules

PROCEDURE Commissioning and Decommissioning of Fleet Vehicles and Parts. Number: G 2104 Date Published: 8 August 2013

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 Lihue, Kauai, Hawaii Original Sheet 5 RULE NO. 2 CHARACTER OF SERVICE

City of Palo Alto (ID # 6416) City Council Staff Report

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

ENGINEERING SPECIFICATION

ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions

Wholesale Developer Services Charges

Level 3 Award in the Requirements for Electrical Installations BS 7671:2018 ( )

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.

Australian/New Zealand Standard

Model Standing Offer for Micro Embedded Generator Basic Connection Services

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Please Refer to Attached Sample Form

Safe Working on or near low voltage electrical installations & equipment

COMMERCIAL QUICK REFERENCE

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Transcription:

DISTRIBUTION CODE

Contents 1 Introduction 2. Advisory and Information Systems 3. Supply 3.1 Quality of Electric Supply 3.2 Interference with other Customers 3.3 Application for the Supply of Electricity 3.4 Re-Located Buildings 3.5 Connection of Supply 4 Electrical Service Lines 4.1 General Requirements 4.2 Underground Service Lines 4.3 Overhead Service Lines Constructed by Customer 4.4 Increase in Load 4.5 Upgrading Service Lines 5 Temporary Supplies 5.1 Responsibility for Builders Supply 5.2 Connection to Supply 5.3 Charges for Temporary Supplies 5.4 Builders Supply: Support for Overhead Wires Page - 2

5.6 Underground Service Lines to Temporary Supplies 5.7 Single Phase Temporary Switchboards and Enclosures 5.8 Earthing 6 Power Factor (PF) Correction 6.1 General Requirements 6.2 Automatic Control of Capacitors 6.3 Effects of Capacitors on Ripple System 7 Motor Starting 8 Tariffs Page - 3

1 Introduction This code has been compiled and issued for the guidance of electricians, consulting engineers and architects who are involved with the design and installation of electrical systems connected to Westpower Limited s network. The code contains policies and procedures that must be undertaken as a condition to obtaining a supply of electricity. The code should be read in conjunction with: Westpower tariff charges. Westpower Electricity Pricing Schedule. The Electricity Regulations 1997 and subsequent amendments. The Electricity Act 1992 and subsequent amendments. Electrical Codes of Practice and subsequent amendments. Appropriate Standards and subsequent amendments. Health and Safety in Employment Act and subsequent amendments. Copies of this Distribution Code can be obtained from the Reception Desk at 146 Tainui St, Greymouth, or the Asset Manager, P.O. Box 388, Greymouth. Page - 4

2 Advisory and Information Services Westpower s staff are available to provide a wide variety of free advice to customers and prospective customers. Please contact ElectroNet for advice on: Tariffs Methods of Supply Load Monitoring Electrical Safety The following ElectroNet staff are also available for consultation: Asset Manager Operations Manager Electrical Supervisor Senior Electrical Engineer Page - 5

3 Supply The supply of electricity and/or network services is conditional on: Relevant Acts and Regulations, including the Electricity Act 1992, the Electricity Regulations 1997 and associated Electrical Codes of Practice. Westpower s use of System Agreement with individual retailers. Westpower s current Electricity Pricing Schedule 3.1 Quality of Electric Supply Technical details are as follows: Single phase two wire or three phase four wire systems of alternating current at a nominal voltage of 230 volts between phase and neutral which except for momentary fluctuations is intended to be maintained within 6% above or below that standard voltage, at your point of connection. NOTE: Westpower is not responsible for the voltage drop caused by customer s service lines. Except for momentary fluctuations the frequency of your supply will be at 50 hertz or within 0.75% above or below this. While we will use our best endeavours to maintain a continuous supply within the above paramaters we cannot guarantee always to do so. 3.2 Interference with other Customers No customer by the operation of any equipment, appliance or installation shall unduly interfere with a satisfactory supply to any other customer. In such cases Westpower will investigate the circumstances of the interference and require the offending customer, where necessary, to take remedial action within a reasonable period. Where the required action has not been taken Westpower may disconnect the equipment causing the interference or, if such disconnection is not possible, Westpower may disconnect the customer s installation. The customer who causes the interference shall meet the cost of investigation and remedial action. Page - 6

Attention is drawn to the effects of harmonic currents and voltages that are generated by electrical and electronic equipment including variable speed AC and DC drives. Although the equipment is required to meet the limitations of ECP 36, interference can still be caused to other customers. Provision of appropriate filtering to eliminate interference is the responsibility of the offending customer. 3.3 Application for the Supply of Electricity Owners of lines are required to give at least 15 working days written notice to the Territorial Authority and other affected utility operators where an electrical reticulation is to be constructed along, over or under any legal road. Furthermore resource consents are required for certain works in some areas, and these can take several weeks to obtain. For this reason it is important that ElectroNet s Asset Management Group is consulted in the early stages of planning, to negotiate supply and metering arrangements. It is also important to ensure adequate written notice can be given in order to meet the customers planned connection dates. 3.4 Re-Located Buildings All re-located buildings are considered as new installations. 3.5 Connection of Supply Supply will only be connected to new installations when the approved contractor responsible for connecting the supply has sighted the completed certificate of compliance. If prescribed work has been carried out while an installation has been disconnected from the supply, a certificate of compliance is required as for a new installation. 4 Electrical Service Lines The following general requirements apply to new and reconstructed service mains in Westpower s area of supply. Only one service main shall be provided for each installation. Where a customer s service line passes through or over a third parties Page - 7

property, the customer must obtain an easement for that section of service line. This requirement applies also to shared distribution lines, in which case the easement must be provided by the customers in the name of Westpower Limited. We require an agreement to grant an easement before supply is connected. This enables work to commence and allows time for the easement process to continue separately. 4.2 Underground Service Lines Customers may choose to install an underground service within their own premises. However, access to Westpower s equipment including service fuse boxes and distribution boxes is restricted to Westpower s approved contractors only. Reparation of any ground that is disturbed in the connection of a consumers underground service to Westpower s network will be paid for by the consumer. 4.3 Overhead Service Lines Constructed by Customer The customer may choose to build his own line providing that the Electricity Regulations 1997 are met and the construction is up to approved standards. The customer owns the line and is responsible for the maintenance on that section of the line. 4.1 General Requirements Service lines are the customer s responsibility. The point of connection of a service main to Westpower s distribution system is defined in the Meters and Lines section of our terms and conditions for Domestic Customers. If it is agreed with the customer, the transformer and pole it is erected on will remain a part of Westpower s system, it must be constructed to Westpower standards and use new equipment. Tensioning of conductors may only be carried out by persons meeting the competency requirements stated in the Electricity Regulations 1997. The customer must supply a Certificate of Compliance covering both the electrical and structural aspects of the line installation before connection to the Westpower network. Page - 8

4.4 Increase in Load Adequate notice prior to any significant load increase should be given to Westpower before connection of supply to prevent problems of future capacity constraints on Westpower s network. 4.5 Upgrading Service Lines Adequate written notification is required before any service lines are upgraded or their position changed. 5 Temporary Supplies and Caravan Sites 5.1 Responsibility for Builder s Supply All persons who are responsible for temporary supplies, such as builder s temporary supplies (i.e. the builder or the owner) must submit a System Connection Form. 5.2 Connection to Supply Requests to connect to the supply should be made through ElectroNet Services Ltd. 5.3 Charges for Temporary Supplies The charges for temporary supplies will be at non-domestic rates as set out in Westpower s Electricity Pricing Schedule. A charge is made for installing the supply and for dismantling the supply at the conclusion of use. 5.5 Builder s Supply: Underground Areas Westpower will install a service box on the boundary of the customer s premises in accordance with its policy for services. If a permanent electricity supply is to be taken from the service box, then it is essential that Westpower is informed of the approximate intended permanent electrical load. This is essential to allow an adequate sized cable to be installed between the service box and the lines or cables supplying the box. 5.6 Underground Service Lines to Temporary Supplies All service lines shall be installed in accordance with NZS 3000. Page - 9

If the intended use of the same cable for the builder s supply is eventually to supply a permanent installation any surplus cable must be coiled up and buried at the foot of the builder s pole with suitable protection against damage. At the supply end of the cable, the cable is to be introduced into the service fuse box and terminated by a qualified contractor who holds an appropriate EAC to do this work. 5.7 Single Phase Temporary Switchboards and Enclosures Switchboards and enclosures must comply with the Electricity Regulations 1997 and NZS 3000. 5.8 Earthing An earth electrode compliant with the Electricity regulations shall be provided as close as practicable to the base of the builder s pole. The earthing conductor shall be insulated and mechanically protected and fixed to the pole over the conductors length. 6 Power Factor (PF) Correction 6.1 General Requirements The power factor of a customer s installation shall be maintained at not less that 0.95 lagging at any time. The power factor shall be determined by Westpower s instruments and shall be assessed on the average value over a 30-minute period. Westpower reserves the right to charge a penalty in addition to the normal electricity charges when it is found that an installation is maintained at less than 0.95 lagging power factor. 6.2 Automatic Control of Capacitors Permanent automatic controlled capacitor installations are acceptable. 6.3 Effects of Capacitors on Ripple System Westpower operate a ripple voltage load control system at a frequency of 425 Hz. Westpower may request that ripple blocking chokes be installed by the Page - 10

customer where power factor correction capacitors are fitted, to avoid ripple signal absorption. If any installation of capacitors on a customer s premises is capable of affecting the Company s control signals adversely, then the customer will be required to supply and install adequate blocking facilities to Westpower s requirements. 7 Motor Starting Motor starting limitations will be determined by the methods detailed in the Electrical Supply Authority Engineers Institute Committee Report on Motor Starting Currents for AC motors. The relative voltage change (r.v.c.) at the point of common coupling and at the main 11 kv supply substation shall not exceed the amount shown in the table below. Frequency SCHEDULE OF RELATIVE VOLTAGE CHANGE (From ESAEI committee report) of Starting At PCC At Main Sub (11kV Bus) I n excess of 10 starts per hour 1.0%.05% In excess of 3 starts pe day but no more than 10 starts per hour Not more than 3 starts per day including not more than 1 start between the hours of 5pm & 11pm on any day Emergancy equipment started infrequently (e.g. fire pumps) 3.0% 1.0% 6.0% 1.5% 12.0% 2.0% Details of fault levels for calculating the r.v.c. are available on request. 8 Tariffs Westpower offers reduced rates for electrical energy where the hours of use are restricted. Please refer to our Tariff Schedule for the various rates. Considerable savings can be made by selecting appropriate controlled tariffs, for both domestic and non-domestic customers. Page - 11

For advice, please contact the appropriate ElectroNet staff below Rodger Griffiths Westpower Asset Manager Ph. 768 2704 Terry Hughes Asset Administrator Ph. 768 2711 Frank Arthur Senior Electrical Engineer Ph. 768 2718 Thomas O Callaghan Senior System Controller Ph. 768 2751 Kent Martin Operations Manager Ph. 768 2753 Cyril Shirley Electrical Supervisor Ph. 768 2702 Westpower Limited P O Box 388 Greymouth Ph. 0800 768 242