ARQUA STATION DF4 + DF7

Similar documents
2-DOOR LAUNDRY CABINET KIT

VIVID SLIMLINE FLOOR MOUNTED BATH MIXER PRODUCT CODE: FINISH: VS745 CHR CHROME STYLISH PREMIUM FINISH CONTEMPORARY DESIGN PHOENIX WARRANTY

Rainwater Harvesting Solutions WATER STORAGE AND RAINWATER HARVESTING USER MANUAL ABOVE GROUND WATER TANKS

SERIES II WALVIT + CUBE. 1.28/0.8 Gal (4.8/3 Litre)

INSTALLATION INSTRUCTIONS TOP MOUNT SINK CH366

2-DOOR LAUNDRY CABINET KIT

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

Contents. Introduction

Installation must be in Accordance with AS/NZS

ASSEMBLY INSTRUCTIONS. Toll-free: MODEL N

HANDS FREE FOOT & KNEE OPERATED TAPWARE

EMERGENCY EYE/FACE WASH

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

FASHION SKIRTED TOILET FOR P & S TRAPS DUAL FLUSH OWNER S MANUAL ITM. / ART # QTA023

Installation and Maintenance Guide SF1593 SF1594 B/E ELECTRONIC LAVATORY FAUCET

INFRA RED MONOBLOC SF2601CP (BATTERY OPERATED) INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

SINK SPECIFICATIONS. ELONGATED DOUBLE BOWL Undermount Model VGR3218BL NOMINAL DIMENSIONS FEATURED MODELVGR3218BL 9" BOWL DEPTH

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

G SERIES - E TOUCH MIXER / TAP

INSTALLATION AND MAINTENANCE GUIDE TUBULAR SERIES WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

65 Series. Valve Operation Manual

Roof access hatch installation instructions

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

Glazed Screens. Handling and care manual (Construction Phase) January Performance Door, Window & Panel Manufacturers

START HERE BEFORE YOU BEGIN STEP 2

Installation Instructions

Series Base mounted pump. Installation and operating instructions

INSTALLATION INSTRUCTIONS TOP MOUNT SINKS

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Installation Instructions Model: AB Single-lever Pull-down Spray Faucet

1/4 ANGLE DIE GRINDER

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH

FAUCET SPECIFICATIONS. Wall Mount Bathroom Faucet Model VG " 10 3/8" MODEL VG05002

INSTALLATION INSTRUCTIONS

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Outdoor Bottle Fillers

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

INSTALLATION and OPERATION BALL WASHER MODEL NO: BW-001N

GENERAL INSTALLATION MANUAL

Installation Instructions for Bike Fixtation. Bottle Fill and Bike Wash Stations Manual Rev. B

CONV-B2000 Conversion Frame Installation / Inspection Manual Approved Under Dispenser SCCS (Spill Containment & Control System)

MODEL EGA220 OWNERS MANUAL

AIM LED LIGHT (wall mount)

INSTALLATION INSTRUCTIONS

PACIFICA Shower Cabin Installation Instructions

RUSH WALL TOP ASSEMBLIES EXT D 15MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES

ASSEMBLY INSTRUCTIONS. Toll-free : MODEL NO

Bianco RainsaverMK4E Installation and Operating Instructions

Product Maintenance Guide

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

TIX402 EOS Installation and Operating Guide

START HERE BEFORE YOU BEGIN. START HERE: Turn off engine, chalk tires with stop block, open the hood and disconnect the battery.

Maintenance. Part A, Section 5. This section covers the following unit configurations.

INSTALLATION AND MAINTENANCE GUIDE EXTREME WM WALL MOUNTED ELECTRONIC FAUCET FOR COLD OR PREMIXED WATER

SHADES TECHNICS HYDROFLUSH BOWL KIT MANUAL

Single shot MODEL EGA700 OWNERS MANUAL

Breezair TBA 550 Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS

Sportworks Northwest, Inc. General Guidelines Inspection: Cleaning: Graffiti Removal: Sticker Removal:

MODEL EGA130 OWNERS MANUAL

LINDGREN-PITMAN General Maintenance of Lindgren-Pitman Hydraulic Systems & Equipment

RTS518 - Rhino Heavy Duty 2 & 3 Crossbar System Hyundai iload, imax, i800, H-1.

PRESSURIZED DIATOMACEOUS EARTH FILTER SYSTEM

Prism Floor Standing Bath Shower Mixer

Always refer to the manufacturers recommendations located within the literature contained within the unit packet.

Q15P. Mitsubishi MQ Triton Dual Cab

Industrial Turbo Meters, Sizes 2" through 6"

MODEL EGA200 OWNERS MANUAL

4" 4" 4 1/4" 11" TOP VIE 3 1/8" Ø1/2" 2" 10 3/8" SIDE VIE VG05002 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1/8"

Requests for Daily Care and Maintenance

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Aqua-Link INSTALLATION GUIDE BEFORE YOU START TOOLS AND COMPONENTS. Choosing a Location. Preparing to Install Your Tank

Manual for 12 Sand Filter/ Pump Combo Unit.

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

New Options Bath Shower Mixer

Installation Manual, Usage Tips, & Warranty Information

sink and tap collection

Features and Benefits

SUBMERSIBLE WATER PUMP

MODEL NO. LG Volt Lawn & Garden Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

RAIN SHOWER SYSTEM WITH HANDSHOWER 8.5 XIAMEN KEEKOE SANITARY WARE CO.,LTD WM ITM. / ART # QBA043 OWNER S MANUAL

Heavy Duty Sprayer Owners Manual Model MS-O

Installation Instructions Model: AB Single-Lever Pull-out Kitchen Faucet

3 PIECE HARD TONNEAU COVER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS UNDERMOUNT SINKS

Owner s Manual WARNING

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

RTS510 Rhino Heavy Duty Track Mount System - MITSUBISHI TRITON MK

Transcription:

The Arqua Station DF4 + DF7 is a complete system to provide fresh tap or filtered water to public spaces. This technical pack includes: Assembly and Installation guide Care and Maintenance For more information, visit streetfurniture.com Note: Failure to install the Arqua Fountain as described in these instructions may void the manufacturer s warranty.

Thank you for purchasing the Arqua Station (Arqua Fountain DF4 and Arqua Pole DF7). Handling Handle the Arqua Fountain and Arqua Pole and their parts in a manner to prevent scratching, warping, bending and twisting. Do not slide parts on concrete or other hard or abrasive surfaces. The sump pits are made from polycrete and should be handled with care. Damage to the pit caused by mishandling is not covered by warranty. Delivery Please check you have received the below items. Missing or damaged parts need to be reported to a Street Furniture sales representative. Arqua Fountain DF4 3 4 2 5 6 1 2. Sump Pit 3. Sump Cover A 4. Sump Cover B 5. 4x M12 threaded rods, 12x hex nuts and 8x washers 6. Allen key 7 9 8 1. Fountain Body (with plumbing attached) 7. Flow controller 8. Y strainer (tap model only) 9. Ball valve (all are connected and attached to fountain hose) 02

Arqua Pole DF7 TAP MODEL 7a 8a 1 9a 10a 7a. Flow controller 8a. Y strainer 9a. Ball valve 10a. Flexible hose (all are connected and attached to the Arqua Pole) 1. Arqua Pole body FILTERED MODEL 7b 3 4 10b 8b 2 11b 9b 5 6 2. Pit 3. Sump Cover A 4. Sump Cover B 5. 4x M12 threaded rods, nuts and washers 6. Allen key 7b. Flow controller 8b. Filter Mount 9b. Filter 10b. Ball valve 11b. Flexible hose (all are connected and attached to the Arqua Pole) 03

INSTALLATION DIAGRAM TAP MODEL sump push button water supply line (1/2 ) button arqua station plan view inside sump plumbing (with push button and fountain shown for orientation) nozzle water supply line (1/2") signage (as required) nozzle button nozzle button flow controller ball valve (1/4") BSP (F) y strainer water supply (at the back of pit) water supply sump The Arqua drinking fountain and refill post have a maximum working pressure of 6 bar (87psi/0.6MPa). Customer or installer to check pressure and install pressure relief valve on supply side as required. 12x washers M12 and hex nuts M12, 4x threaded rods M12 265mm L (supplied by Street Furniture) water supply line (1/2") arqua station overview water supply line (1/2") ball valve (1/4") BSP (F) y strainer 12x washers M12 and hex nuts M12, 4x threaded rods M12 265mm L (supplied by Street Furniture) 25mm leveling screed, nominal 40mm 25mm 125mm concrete footing 125mm side elevation (arqua pole DF7) inside sump detail waste pipe nominal 50mm dia ID front elevation (arqua fountain DF4) inside sump detail 04

INSTALLATION DIAGRAM FILTERED MODEL sump push button water supply line (1/2 ) button arqua station plan view inside sump plumbing (with push button and fountain shown for orientation) nozzle water supply line (1/2") signage (as required) nozzle button nozzle button flow controller ball valve (1/4") BSP (F) filter water supply (at the back of pit) Recommended separation 580mm sump The Arqua drinking fountain and refill post have a maximum working pressure of 6 bar (87psi/0.6MPa). Customer or installer to check pressure and install pressure relief valve on supply side as required. connected water supply line (1/2") 12x washers M12 and hex nuts M12, 4x threaded rods M12 265mm L (supplied by Street Furniture) water supply line (1/2") arqua station overview ball valve (1/4") BSP (F) 12x washers M12 and hex nuts M12, 4x threaded rods M12 265mm L (supplied by Street Furniture) connected water supply line (1/2") 50mm 25mm leveling screed, nominal 40mm 25mm 50mm 125mm concrete footing 125mm side elevation (arqua pole DF7) inside sump detail waste pipe nominal 50mm dia ID front elevation (arqua fountain DF4) inside sump detail 05

RECOMMENDED INSTALLATION PROCEDURE Important: All plumbing and drainage work should be done in accordance with local authority s regulations and installed by a licensed contractor. Part 1 Sump Pit Installation Note: Ensure water supply has been turned off at the main source. 1. Pour concrete footing to 185mm below final ground level with waste pipes in place. The waste pipes need to be located in the centre of the respective sumps with the waste pipes protruding to at least final ground level. Allow to cure. 2. Slide pit for the fountain down over the waste pipe and orient the pit to receive the fountain in the desired final position. Please note the arrow on the sump indicates the direction the fountain will face. Do the same for the pit for the Refill Pole. 3. Carefully mark the 4 holes in the pit bases, onto the concrete footing, ready for drilling. Remove the pits. 4. Drill 4 x 14dia holes to a depth of 125mm in each pit. 5. Using the supplied nuts, secure the 4 x M12 Threaded Rods to the sump pits. 6. Slide the pits down over the waste pipes and the threaded rods into the drilled holes. Ensure the 4 x M12 Threaded Rods are embedded 125mm into the concrete footing. 7. Once alignment is confirmed, use a suitable epoxy adhesive (as supplied by installer) and follow the manufacturer s instructions to secure the rods with pits in place. Allow it to set. (Note: Correct preparation and installation of the concrete footing is paramount) 06

8. Once set, undo the nuts from the threaded rods and remove the pits. 9. Cover the footing with a screeded bed of sand-cement to a nominal thickness of 40mm. 10. Slide both pits down over their respective waste pipes and threaded rods onto the leveling screed. Install pit horizontally and level with pavement. Adjust screeded sand-cement bed as needed to ensure that the top of the pits sit at pavement line and that the pit rims are level. 11. Mark the waste pipes at 25mm above the floor. Remove the pits and cut the waste pipes at the marked level. Slide pits back on and seal around the waste pipes. 12. Using the supplied fixing nuts and washers, fasten the 4x M12 threaded rods to the bottom of each pit. For Arqua Station Tap 13a. Choose one of the 3 water feed starter points on the sides of the pits and drill/knock through. Install the separate water supply lines (1/2 ) through the holes and seal around the pipes. For Arqua Station Filtered 13b. (i) Choose one of the 3 water feed starter points on the side of the Refill Pole DF7 pit and drill/knock through. Install the water supply lines (1/2 ) through the holes and seal around the pipes. (ii) Locate the water feed starter point on the Refill Pole s pit that s closest to the Fountain s pit and drill/knock through. Then, locate the water feed starter point on the Fountain s pit that s closest to the Refill Pole s pit and drill/ knock through. Install the connected water supply line (1/2 ) through the holes of the Refill Pole and Fountain and seal around the pipes. 14. Flush the supply line(s) by turning on the water at the main source to remove any possible traces of particles or sediments from the water supply. Once completed, turn off the water supply at the main source. 15. Back fill around pits and finish pavement against pit rim edges. 16. Fasten cover plates until ready to receive the Arqua Fountain and Refill Pole. Installer on site to make openings in sump lids safe until fountain/refill pole are installed. 07

RECOMMENDED INSTALLATION PROCEDURE Part 2 Arqua Pole Installation 1. Flush the supply line(s) by turning on the water at the main source to remove any possible traces of particles or sediments from the water supply. Once completed, turn off the water supply at the main source. Align small hole with pit rim to ensure correct fountain height. 2. Lower the Arqua Pole onto the threaded rods. Ensure that the bottom of the small hole that s located between the hatch and the baseplate sits in line with the pit rim. Adjust for level and height by raising and lowering the adjusting nuts supplied. Check the perpendicularity of the pole. Note: Ensure the distance between the bottom of the pit and the Arqua Pole baseplate is approximately 50mm. 3. Once the refill pole is levelled, tighten the fixing nuts above the plate. Check the perpendicularity above the plate before completely tightening the fixing nuts. 4. Use the supplied allen key to remove the hatch plate of the Arqua Pole. Feed the end of the flexible hose through the appropriate hole at the bottom of the Arqua Pole. 5. Connect the Arqua pole s flexible hose to the water supply line. Arqua Fountain Body Installation 6. Lower the fountain body onto the threaded rods. Ensure that the bottom of the small hole that s located just above the fountain s base plate sits in line with the pit rim. Adjust for level and height by raising and lowering the nuts supplied. Align small hole with pit rim to ensure correct fountain height. Note: Ensure the distance between the bottom of the pit and the Arqua Pole baseplate is approximately 50mm. 7. Once the fountain is levelled, tighten the fixing nuts above the plate. Check the perpendicularity of the fountain body above the plate before completely tightening the fixing nuts. 08

8. Connect the fountain s flexible hose and plumbing to the main water supply/connected water supply line. Turn on the water at the main source. 9. Test the water supply by turning on ball valves for both the Arqua Fountain and Refill Pole and pressing the respective push buttons. Allow time for water to flush out air pockets. Allow for water through pipework and filters to flush out new taste. 10. After testing, lay the sump covers for both the Arqua Fountain and the Arqua Refill Pole in place and fix them using the supplied screws. Clean both fountain and refill pole bodies and sumps (including inside of sumps), surroundings and leave the area neat and tidy. 09

care and maintenance General Maintenance Street Furniture recommends a periodic maintenance program for cleaning, touch up and repair if needed. Its frequency is dependent on the usage or proximity to industrial or marine environments. In general, we recommend cleaning once every quarter. Aluminum This is a low maintenance material. However, all surfaces should be cleared of dust or dirt using clean water or a mild detergent. Do not use any abrasive detergents, scrub the surface or use a high pressured hose. Powder Coated Materials External surfaces should be regularly washed down, especially in corrosive conditions (eg. salt, or chemical deposits). Any exposed metal resulting from damage to the coating should be repaired quickly to avoid corrosion stains as well as to protect the metal. Please check the powder coating code to make sure it matches the colour of your product. Touch up of blemishes or deep scratches can be made with Professional Touch-Up Paint, applied using an artist s brush or fine spray. It is available to purchase from: CR Laurence Ph: 1800 424 275 www.crlaurence.com.au Available in pressure pack cans. Most Interpon powdercoat colours have been matched. Cleaning the Y-Strainer (for Tap models only) Important: Ensure the plumbing is installed as per the installation diagrams on page 03 / page 04 to allow for easy maintenance and proper functioning of the Arqua Station DF4 + DF7. Maintenance on the Arqua Station DF4 + DF7 should only be performed by licensed plumbers or Street Furniture agents. The removal or substitution of any components from the feed line during or after installation will void the manufacturer s warranty. With normal use and regular maintenance, this product will perform reliably. Cleaning and back-flushing the mesh strainer found in the sump of the Arqua Fountain and in the Arqua Pole should be performed at regular intervals. Street Furniture recommends not longer than quarterly intervals. Arqua Fountain DF4 1. Remove the sump cover of the Arqua Fountain DF4. 2. Locate the isolating valve and strainer in the sump. 3. Turn the water off at the isolating valve. 4. Unscrew the hexagon head on top of the Y strainer. 5. Remove and flush the mesh. Note: Take care to not damage the mesh as this strainer is required to be fully operational to maintain the warranty on the upper push valve. 6. Reassemble the strainer, and apply teflon tape to the threads where necessary. 7. Turn the water back on and check for leaks. 8. Replace the sump plates. The pit has been designed to capture sediment over time and thereby protect the drainage line, so periodically remove the pit covers and clean the interior. 10

care and maintenance flexible hose flow controller y-strainer water supply line (1/2") ball valve (1/4 ) BSP (F) fountain DF4 plan view (showing plumbing) flow controller y strainer ball valve (1/4") BSP (F) Arqua Refill Pole DF7 1. Remove the hatch of the Arqua Pole DF7. 2. Locate the ball valve and strainer. 3. Turn the water off at the ball valve. 4. Unscrew the hexagon head on the short leg of the Y-strainer. 5. Remove and flush the mesh. Note: Take care to not damage the mesh as this strainer is required to be fully operational to maintain the warranty on the upper push valve. 6. Reassemble the strainer, and apply teflon tape to the threads where necessary. 7. Turn the water back on and check for leaks. 8. Replace the hatch. The pit has been designed to capture sediment over time and thereby protect the drainage line, so periodically remove the pit covers and clean the interior. refill pole DF7 back view (with hatch open) 11

care and maintenance Replacing the Filter (for Filtered models only) If you have the filtered Arqua Station DF4 + DF7, the filter in the Refill Pole DF7 (which is a single use unit) needs to be replaced periodically. The interval depends on the quality of the water supply and the quantity of the water filtered. Normal replacement should be every 56,000 litres (refer also to the filter supplier s literature). Replace more frequently if the water contains a higher than normal particle count. 1. Remove the hatch plate of the Arqua Pole DF7. 2. Turn off the water at the isolating ball valve. The filter is bayonet fitted into the mounting bracket. 3. Rotate the filter approximately 90 degrees and withdraw it. 4. Wipe out the inside of the mounting with a clean cloth to remove any accumulated silt. 5. Position the new filter and rotate into place. Hand-tightening only is required. 6. Turn the water back on and check for leaks. Allow for water through pipework and filters to flush out new taste. 7. Replace the hatch plate. The pit has been designed to capture sediment over time and thereby protect the drainage line, so periodically remove the pit covers and clean the interior. flow controller ball valve (1/4") BSP (F) filter mount filter back view (with hatch open) 12

care and maintenance Warranty Street Furniture warrants all products for a period of twelve months from the date of delivery against faults which are the result of poor workmanship or faulty materials. In severe cases of abuse the valve can be damaged. This intentional damage falls outside of Street Furniture warranty guidelines of normal operation. Replacement parts and valve kits are available from Street Furniture. In the case of a warranty claim being made, the damaged component must ultimately be returned to Street Furniture for evaluation and analysis. Please call 1800 027 799 (Toll-free Australia wide) for further assistance. 13