CLOGGING INDICATORS SUMMING-UP DESCRIPTION

Similar documents
RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

SSR SSR SSR SSR

Willys Overland Production Figures

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

Vacuum Automation 2.1. The future depends on good product choices

S: With magnet. Bore x stroke (basic type) Cushion P: pneumatic adjustable

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

Orifice flowmeter F O N4

Vehicle Technical Specifications

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD.

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

About Tapflo. Tapflo - your reliable pumpchoice. Tapflo quality. The history of Tapflo

INSTRUMENT PANEL CLUSTERS

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

part of the EVOX RIFA GROUP

Combined pump and gripper Medium

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

~... se_rv_ic_e M_A_NU_AL_2_44_4._z1,~

HONDA NO ENGINE DESCRIPTION FULL SET HEAD SET CYL. HEAD CHK-9827SK 061A1-PH A1-PH2-010 CHK-9845SA PR PR3-000

CTR* /117 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41 lt HYDRAULIC SYMBOL

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

Pressure Switch. visit our website

Indicators Series. FMU p-indicators and Pressure Indicators Max 420 bar. Measuring critical system parameters is essential.

Chapter 10: Valves for Pipe Mounting

ELITE 2-BURNER PROPANE BARBECUE Assembly Manual

ALC40 Series 105 C. RoHS. Compliant

Order No. of the options EMC filter Class A

Summary of Specifications

ALC10 Series 85 C. RoHS. Compliant

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

U36D SERIES Engineering Bulletin Mar 07

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

22PD/32PD Series. High Pressure Duplex Filters. A duplex design with a wide application capability. Product Features: Contact Information:

APPENDIX A Instruction Set. Op Code. T states Flags Main Effects. Instructions

SELECT 3-BURNER PROPANE BARBECUE Assembly Manual

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Control Circuit Components Push Button Units and Indicator Lights

Collision Avoidance System CAS-M light. Manual

Milroyal C. PD 3661 Effective 6/2009. MilRoyal C

Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices S T C. Tel:

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

THD. Series. Heavy Duty Actuators. Pneumatic Actuators for Quarter-Turn Valves and Dampers CONTROLS. Torques to 1,600,000 In-lbs

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

Compact cylinders series NYD Double acting with magnetic piston, ISO M5 to G1/8 Piston Ø 20 to 100 mm

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

Pressure Switch. visit our website

P1X Series. Compact Rodless Air Cylinders Contents

Pressure Switch. visit our website

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

VACUUM PUMP P5010. Profit from new vacuum technology

Housing: black plastic Measuring element: copper spring. Protection rate: IP31 Threaded: axial type. Setting: 0 10 bar (0 150 psi)

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

Linear Guides Pneumatic linear drive Series OSP - P Adaptive modular system The Ortman System Plus OSP provides a comprehensive range of linear guides

LYCOMING CYLINDER PRICING

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

CSci 127: Introduction to Computer Science

Audit Attestation for. MICROSEC Micro Software Engineering & Consulting Private Limited Company by Shares

PNEUMATIC VALVE MANIFOLDS 11 mm - Series 501 M7 or with push-in fittings Ø6 mm

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

Solenoid coil for control in potentially explosive areas Type BZ

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

BRAZED PHE. Performance - Economy - Reliability - Compact

SIRIUS 3RU2 Thermal Overload Relays

Technical Datasheet. Differential Pressure Gauge Diaphragm DG Range. Performance characteristics. Product applications. How can we help you?

Sectional Directional Control Valve RSQ 240

SELECT 4-BURNER PROPANE BARBECUE Assembly Manual

PART LIST P T O P T O S E R I E S S E R I E S

Type 520C 85 C Long Life, Inverter Grade, Aluminum High Ripple, Long Life Screw Terminal Type

Pneumatic cylinders, piston-ø mm Double acting with magnetic piston DIN ISO 15552

Pneumatically operated 2/2 way diaphragm valve with stainless steel actuator

Spare parts list Inline filter FLND switchable

KH Hypoid Series Precision Range Steel

Field Variable Area Flowmeters BFP Global Purgemaster

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Type 550C 105 C High Ripple, Inverter Grade, Aluminum Ultra-Ripple, Long Life Screw Terminal Type

AXIAL PISTON PUMPS VARIABLE DISPLACEMENT

GH General Horizontal, Close Coupled and Frame Mounted Pumps

SATRON VT Pressure Transmitter

LMP series

Interactive Catalog Replaces Catalog Pages

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

CTR* /108 ED HYDRAULIC POWER UNITS. TANK CAPACITY from 8 lt to 150 lt. PUMP FLOW RATE from 1,6 lt to 41lt

SUCCESS INDICATORS FOR THE PLAN MMBTU ANALYSIS

Product Cross Reference

Transcription:

SUMMINGUP CLOGGING PRESSURE FILTERS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. Vandal proof Differential, el. ATEX OFFLINE FILTERS Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. ATEX RETURN FILTERS Pressure gauges Pressure switches Differential, visual Differential, electrical Differential, el. + LED Differential, el. + thermostat Differential, el. + visual Differential, el. ATEX SUCTION FILTERS Vacuum gauges Vacuum switches DESCRIPTION During the system operation, the pressure drop through the filter increases as the element clogs, due to the contaminant retained. The filter element must be replaced when clogged and anyway before the pressure drop reaches the bypass valve set value. For this reason it is recommended a clogging indicator on the filter. It gives a visual or electrical indication and must have a set value lower than the bypass valve set value, to get an exact indication of the right time for fi lter element replacement. On return and low pressure filters the clogging indicator can be a pressure gauge or a pressure switch, measuring the pressure upstream the filter. On some return filters and on high pressure filters, the clogging indicator can be of differential type: measuring the pressure upstream and downstream the fi lter and activating a signal when the differential pressure reaches the set value. On suction filters the clogging indicator is a vacuum gauge or a vacuum switch, measuring the depressure downstream the filter. All the UFI filters have the port for the indicator as a standard feature; if the fi lter is ordered without indicator the port is plugged with a removeable plug allowing the indicator to be added easily at any time.

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION FOR PRESSURE FILTERS INDICATOR SERIES DESCRIPTION FOR PRESSURE FILTERS SERIES Pressure gauge Scale 0 bar (0 1,2 MPa) PE Pressure gauge stainless steel, glycerine filled 039.0184.1 Scale 0 bar (0 1,2 MPa) PE Pressure switch P1 Setting 1,5 bar (150 kpa) PE 77 9 SPDT, Max voltage 250V 50 Hz Max current 6 A resistive, 1 A inductive Protection IP65 connector DIN 43650 N0 S0 Differential VISUAL ELECTRICAL indicator for FPE A+, B+ 63,5 M14 Differential VISUAL indicator U0 W0 for FPE A+, B+ 20 M14 5B 5D 5E 5F AB AD AE AF Differential VISUAL indicators (PA PB PD PL PM),5 ø

SUMMING UP CLOGGING INDICATOR SERIES DESCRIPTION FOR PRESSURE FILTERS SERIES 6B 6D 6E 6F 7B 7D 7E 7F T0 T2 T3 T6 DB DE DF DD Differential ELECTRICAL indicators with THERMOSTAT C Differential VISUAL ELECTRICAL indicators E0 76 E6 72 E2 73 E3 M2 M3 M6 008.0239.2 008.00.2 CB CD CE CF EB ED EE EF Differential ELECTRICAL indicators ATEX 008.02.2 008.02.2 Differential ELECTRICAL indicators Differential ELECTRICAL indicators with LED ( V) for visual indication Differential ELECTRICAL indicators VANDAL PROOF 56 59 (PA PB PD PL PM) 50 76 (PA PB PD PL PM) (PA PB PD PL PM) (PA PB PD PL PM) (PA PB PD PL PM) PA PB PD PL PM (PA PB PD PL PM) 98 ø,5 106 REED SWITCH NO G R 2 3 C 1+ 4

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION FOR RETURN FILTERS INDICATOR SERIES DESCRIPTION FOR RETURN FILTERS SERIES Pressure gauge Scale 0 6 bar (0 600 kpa) RA RB RC RH Pressure gauge Scale 0 6 bar (0 600 kpa) RA RB RC RH Pressure gauge stainless steel, glycerine filled 039.0178.1 Scale 0 6 bar (0 600 kpa) RA RB RC RH Pressure gauge stainless steel, glycerine filled 039.0183.1 Scale 0 6 bar (0 600 kpa) RA RB RC RH P1 Pressure switch Setting 1,5 bar (150 kpa) SPDT RA RB RC RH P2 Setting 3 bar (0 kpa) SPDT W execution 77 P4 SPDT 9 P6 SPDT RB SPDT, Max voltage 250V 50 Hz Max current 6 A resistive, 1 A inductive Protection IP65 connector DIN 43650

SUMMING UP CLOGGING INDICATOR SERIES DESCRIPTION FOR RETURN FILTERS SERIES 5B 5C AB AC Differential VISUAL indicators,5 ø 6B 6C CB CC Differential ELECTRICAL indicators 7B 7C EB EC Differential ELECTRICAL indicators with LED ( V) for visual indication G 4 R 2 3 C 1+ T0 T1 DB DC Differential ELECTRICAL indicators with THERMOSTAT C 59 Differential VISUAL ELECTRICAL indicators E0 71 E1 008.0239.2 008.0234.2 Differential ELECTRICAL indicators ATEX 56 ø,5

PRESSURE INDICATION DIFFERENTIAL PRESSURE INDICATION FOR OFFLINE FILTERS INDICATOR SERIES DESCRIPTION FOR RETURN OFFLINE SERIES 5B AB Differential VISUAL indicators OF UOW,5 ø Differential ELECTRICAL indicators 6B CB OF UOW Differential ELECTRICAL indicators with LED ( V) for visual indication 7B EB OF UOW G 4 R 2 3 C 1+ T0 DB Differential ELECTRICAL indicators with THERMOSTAT C OF UOW 59 Differential VISUAL ELECTRICAL indicators E0 OF UOW Differential ELECTRICAL indicators ATEX 008.0239.2 OF UOW 56 ø,5

SUMMING UP CLOGGING FOR SUCTION FILTERS INDICATOR SERIES DESCRIPTION FOR SUCTION FILTERS SERIES 10 Vacuum gauge SC SD SE 11 Vacuum gauge SC SD Vacuum gauge 008.0111.2 SC SD SE Glycerine fi lled 2 Scales Vacuum switch 91 Setting 0,2 bar (20 kpa) SC SD SE SPDT 77 9 SPDT, Max voltage 250V 50 Hz Max current 6 A resistive, 1 A inductive Protection IP65 connector DIN 43650 Is this datasheet the latest release? Please check on our website. Technical data subject to variations without prior notice. EN 03a/2011