GENERAL NOTES "---" indicates that the feature is not an option for this case model and/or that the data is not yet available. LED lights only. Maximum of 5 rows of Standard Output LED lighted shelves. SHIPPING WEIGHT Case Weight ---
ELECTRICAL DATA Case Fans Per Case High Efficiency Fans 120 Volts Amps Watts 4' 1 0.23 0.18 6' 2 0.47 35.00 8' 3 0.70 53.00 12' 4 0.93 71.00 LIGHTING DATA Case Lights Per Row Light Clearvoyant v4 LED Lighting (Per Light Row) Standard Power High Power (Cornice or Shelf) (Cornice Only) 120 Volts 120 Volts Amps Watts Amps Watts 4' 1 4' 0.05 5.9 0.12 14.9 6' 2 3' 0.08 9.4 0.20 23.8 8' 2 4' 0.10 11.8 0.25 29.9 12' 3 4' 0.15 17.6 0.37 44.8 GUIDELINES AND CONTROL SETTINGS BTUH/ft Superheat Discharge Discharge Application Conventional Parallel Set Point @ Bulb Evaporator Air Air Velocity Cut Produce 950 910 6-8 F 32 F 36 F 150 FPM Bulk Produce 767 735 6-8 F 34 F 38 F 150 FPM DEFROST CONTROLS Defrosts Per Day Timed-Off Defrost Termination Temp Fail-Safe (min). 6 40 42 F "---" indicates that the feature is not an option for this case model and/or that the data is not yet available. Listed BTUH/ft data represent unlighted shelves. For LED lighting, add 9 BTUH/ft per row of lighted shelving. BTUH load increases by 132 BTUH/ft when aftermarket merchandising accessories are utilized. Listed evaporator temperature represents unlighted shelves. For lighted shelves and/or aftermarket merchandising accessories, reduce the listed evaporator temperature by 2 F. Conventional Discharge Air Control Recommended Settings: Cut-In Temp = Discharge Air + 2 F; Cut- Out Temp = Discharge Air - 2 F. Listed discharge air velocity represents the average velocity at the peak of defrost. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4 F below the listed evaporator temperature.
SECOND NATURE DATA BTUH/ft (DR) Supply Fluid Temp Discharge Air Temp Case Model Coils Application Front Sill Type Conventional Parallel GPM/ft (DR) 1 Cut Produce Standards 950 910 0.25 20 36 1 Bulk Produce Standards 767 735 0.09 20 38 1 Bulk Produce Standards 767 735 0.17 25 38 1 Cut Produce Standards 950 910 0.45 25 30 SECOND NATURE DATA Coils Application Front Sill Type Defrost Fail Safe (Min) Timed Off Defrost Termination Temp Fail Safe (Min) Warm Fluid Defrost Termination Temp Case Model 1 Cut Produce Standards 6 60 47 26 49 1 Bulk Produce Standards 6 60 47 26 49 1 Bulk Produce Standards 6 45 47 26 49 1 Cut Produce Standards 6 45 47 26 49
CORNICE OPTIONS CURVED CORNICE CURVED CORNICE FACETED CORNICE FACETED CORNICE WITH NIGHT COVER WITH NIGHT COVER FLAT CORNICE 34 7/8" 40 1/4" 34 3/4" 38" 34" 36 5/8" FLAT CORNICE WITH WITH STANDARD NIGHT COVER FLAT FRONT 2 28 3/16" [71.5 cm] 22 5/16" [56.7 cm] 33 1/16" [84.0 cm] 27" [68.6 cm] 33 7/16" [84.9 cm] 27 3/8" [69.5 cm] FRONT OPTIONS FLAT FRONT CLASSIC 2 METAL 21 3/16" [53.8 cm] 30" [76.2 cm] 30" [76.2 cm] 33 1/8" [84.1 cm] 27 1/4" [69.1 cm] CLASSIC 2 POLYMER ORIGIN 2 21 3/16" [53.8 cm] 30" [76.2 cm] 30" [76.2 cm] Front sill height and overall case height varies with base frame height.
OPTIONAL WIRING TO THE TOP 12 in X 10 in X 4 in 34 7/8" [88.6 cm] 9" MIRROR OPTIONAL 9" MIRROR OPTIONAL 80 15/16" [205.6 cm] SHIPPING HEIGHT 78 11/16" [199.9 cm] OVERALL CASE HEIGHT 75 3/8" [191.5 cm] CASE HEIGHT 49" [124.5 cm] INTERIOR HEIGHT REAR PIPE BOX 41 1/2" [105.4 cm] VISUAL DISPLAY LOAD LIMIT 1 1 16 in 16 in 18 in 32 1/4" [81.9 cm] COIL PLENUM 75 1/8" [190.7 cm] SHIPPING HEIGHT 72 7/8" [185.0 cm] OVERALL CASE HEIGHT 69 1/2" [176.6 cm] CASE HEIGHT REAR PIPE BOX 18 in COIL PLENUM LOAD LIMIT 11" [27.9 cm] 28 1/8" [71.4 cm] 31 3/4" [80.6 cm] 22 3/4" [57.8 cm] 27" [68.6 cm] 39 1/4" [99.7 cm] 32 5/8" [82.9 cm] 43 1/4" [109.9 cm] WIRING TO THE TOP (OPTIONAL) 2" MINIMUM AIR GAP PIPING TO THE TOP (OPTIONAL) 12" [30.5 cm] REAR REFRIGERATION LOCATED 11 1/4" ABOVE FINISH FLOOR 43 1/4" [109.8 cm] 39 1/4" [99.7 cm] 32 5/8" [82.9 cm] 28 1/2" [72.4 cm]* 15 13/16" [40.2 cm]** 35 1/2" [90.2 cm]** 3" [7.6 cm] 28 5/8" [72.7 cm] 5 1/8" [13.1 cm] 6 5/8" [16.8 cm] 17" [43.2 cm] ELECTRICAL JUNCTION BOX 1 1/2" PVC DRAIN CONNECTION DEFAULT REFRIGERATION 1 1/2" [3.8 cm] {END} 48" [121.9 cm] 72" [182.9 cm] 96" [243.8 cm] 144" [365.8 cm] 8 3/4" [22.2 cm] * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND DRAINS 1 :AVAILABLE SHELF SIZES: 10", 12", 14", 16", 18" & 20" Ends add approximately 1" to case height, 1/2" to the back & 1" to the front. Back panels add approximately 1" to case height.