LED GEL MOUNTED FRAME

Similar documents
INSTRUCTION MANUAL. All PrimeTime Studio Lights are equipped with advanced reflector technology.

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

SOFT LED 8 DATASHEET

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

QUICKSTART GUIDE CHECKED BY

WAVELIGHT -2 USER INSTRUCTIONS. Description:

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

shadow focus floodlight SFS-300 INSTRUCTIONS

Measurements are expressed in millimeters.

LED Pinspot 2. Snapshot. User Manual

LED Pinspot 2. Snapshot. User Manual

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

LHS-001 QUICKSTART GUIDE. 650 Watt Tungsten Open Face Light (Lightstar)

Operation Manual Image

USER MANUAL LUX-LD30W LED MOVING HEAD

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

USER MANUAL PAR56 LED PAR CANS

REMBRANDT 2,5/4 kw Dual Power Daylight. Mod. 2532

P/N Wheeler. user manual

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

The Miniature LED Fresnel 20W - CRI>96

HLS Watt Halogen Illuminator Service Manual

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

CH-158 Color Bank 8 USER MANUAL

Lighting BRINGING IMAGINATION TO LIGHT PHX 250 LED ZOOM PROFILE SPOT SUMMARY FEATURES Degree Zoom Lens Degree Zoom Lens

Installation Instruction ALG Series LED Area Light Version: 3.1

Snapshot. User Manual BOB LED

Project. Type. Notes. (1) D dimming (0-10V) 5% standard

The 4-Lamp Mega Fixture Built-in Barndoors Removable Reflector, Louver and Lamp Harness Twist-on Locking Center Mount True Match daylight, tungsten

Instructions for Mounting and Operation of the ARC Model XS Wall Xenon Light Source System

Fluorescent Ring Light with Dimmer INSTRUCTIONS

1.2.5 kw POSITION POSITION

AFL10-LED-KIT Architectural FloodLight HID to LED Upgrade Kit kl_afl10_ledkit_spec.pdf

I1 7.5 Pre-Lit Clear Christmas Tree

// SoftLED Series 2017 Catalog

Wireless Dimmer Installation and User Guide

LAD6 6 LED Architectural Downlight

Notes: Indirect. 5 1/2" 140mm. 5 1/32 128mm

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Ichip Mystére LED FOLLOWSPOT USER MANUAL

HW, WA, WRSN and WRSM Series

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

CFL-LED-KIT Compact FloodLight, LED 2.0 Upgrade Kit kl_cfl_ledkit_spec.pdf

800 TO 2800 LUMEN 4 LED CYLINDER HYPERBOLIC/PARABOLIC/WALLWASH OPEN APERTURE

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

Compact LED profile with zoom

HSN, HSM, HIS, IC, TN, CC and IW Series

Lighting BRINGING IMAGINATION TO LIGHT PHX LED ZOOM PROFILE SPOT SUMMARY FEATURES Degree Zoom Lens Degree Zoom Lens

LAD8 8 LED Architectural Downlight

enlighten your world make your world brighter make your world easier light up your world

HD 7700 Setup & Operator Manual

Motion and Light Sensor Kit LHBAS51

SAVE THESE INSTRUCTIONS

LAD4 4 LED Architectural Downlight

LCD4 4 LED Commercial Downlight

LCD8 8 LED Commercial Downlight

LCD6 6 LED Commercial Downlight

LumeLEX 2084 SERIES INSTALLATION INSTRUCTIONS THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

DIMLUX.NL LET THERE BE LIGHT DIMLUX EXPERT SERIES. User Manual. DimLux is a registered trademark of. airsupplies

PENDANT MOUNT - DIRECT

ASSEMBLY INSTRUCTIONS

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Seem 6. Narrow 6 aperture slot fluorescent luminaire that integrates with the ceiling for a clean unobtrusive aesthetic.

Welcome to PTI--Photon Technology International--Optical Building Blocks!

OCTA FLUORESCENT 7 SOCKET FIXTURE

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Operations Manual Eagle 1000 Series Stretch Wrapper

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

PRODUCT SPECIFICATIONS

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

Installation Manual. CS9300 Professional Series Landscape Lighting System

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

LED IMPORTANT SAFETY INSTRUCTIONS

Magnetic Mount 60 Watt Low Profile LED Flood Light - Glare Shield - 10' Cord V AC

avenue led features dimensional data performance Narrow 3" slot LED with frosted satin lens.

ft. ft Signature Balsam Fir Tree ITEM Item 68607

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

PENDANT ASYMMETRIC MOUNT - DIRECT. Project. Type. Notes

BLACK BODY DIMMING 800/1300 LUMEN 8 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC8 SERIES

USER S MANUAL TUBE SEALER. Model SE250. No. CAT.SE25010Ce

Self-Testing Industrial Series

LyteLaunch Dry - Wet and DMX Models. Operation Manual

solana semi-indirect indirect Low profile pendant with adjustable optics

ALU-29CF Portable Light NSN:

ECO Spot 2500 User Manual

Product Innovation Award winner Architectural/Flood lighting. Exterior 400 Range. Exterior 400 Range

ECO Spot 2500 User Manual

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

Bionic Perimeter Standard C o v e & P e r i m e t e r

300 Watt Portable Work Area Light Tower - Extendible Tower W/ Wheels - (2) 150 Watt LED Lights

PENDANT MOUNT. Project. Type. Notes

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

PENDANT MOUNT - DIRECT. Project. Type. Notes

Notes: (1) not recommended with staggered lamping (2) Not available with T8 lamping.

DIMLUX.NL LET THERE BE LIGHT DIMLUX EXPERT SERIES. User Manual. DimLux is a registered trademark of. airsupplies

Mania EF1 user manual

Series Mounting Accessory Distribution Source Color Temperature Voltage 10DEG 20DEG 40DEG 60DEG 60X20DEG

Transcription:

LED31-11onmp1.pdf INSTRUCTION MANUAL Model: LED-31-11-3200(5600) Lamps: 15 4 W LEDs driven at 2 W Driver: Electronic, high frequency Beam angle: 11 degrees Voltage: 120, 230, 277 50-60 Hz Manufacturer: PL Systems, Inc. Address: 10529 Olympic Drive, # 102 Dallas, TX 75220 (214)-393-5998 (voice) (214)-393-5999 (fax) e-mail: info@kw2.com Web page: primetimelighting.com LED-31-11-120 GEL MOUNTED FRAME NEAR APERTUR INCLUDED HONEYCOMB fig. 1 GEL FRAME FAR APERTURE GENERAL INFORMATION Thank you for your selection of one of the most effective studio luminaires, the LED-31-11. This high performance luminaire should provide many years of low cost operation. The LED-31-11 is designed to maximize "throw" or "punch" by collimating the light into a narrow beam (+/- 5.5 dgr.) for throw, then the desired light pattern is achieved by use of gels or holographic filters to produce the desired spot size. Asymmetric beams are a reality with horizontal to vertical ratios of 6-1 being the norm. The 10x60 horizontal film can spread the light to several news anchors from one fixture. Unwanted spill onto monitors or illuminating a standing talent is effective with the 5x30 vertical filter. Side glare is controlled with optional honeycomb. The luminaire provides a mounting slot for holding gel frames and/ or honeycombs. The LED-31-11 performs like a fresnel for a fraction of the energy. The LED-31-11 draws a mere 35 Watts. The LED-31-11 is offered in tungsten (3200 K) or daylight (5600 K). The LED-31-11 is available in full power, voltage dimming, analog/on board dimming and DMX dimming. The LED-31-11 housing is made of aluminum and powder coated in non-reflective black. Accessories are made of steel and alloy aluminum. Standard luminaires are equipped with detachable 10' long power cords. Each 120 volt cord is equipped with Edison 3-prong connectors. Other voltage models are shipped without plug unless specified. Fused power receptacles are supplied for the 120 volt models. Adjacent fixtures may be powered with this connector so long as the load does not exceed 4 amps. (fig. 2) The switch controls the power to the one fixture. Power to the luminaire is indicated when the switch is lit. Ordinary grip devices allow stand mounting as well. CAUTION Do not stare at the light source. The LED-31-11 must be mounted in vertical orientation, as shown in fig1. This is to insure cooling of the LEDs through the ventilated case. Over heating will cause premature failure. p1

5 analog 0-10 V signal connection 4 luminaire switch 2 power out 1 power in 6 Manual / remote dimming selector and manual controller 3 fuse 6A Rear view of DAN fixture fig 2 7 5 4 9 8 1 & 2 6 fig 3 1. Power in 120 VAC removable power cable. 2. Power out to additional luminaires. 3. 6 amp fuse with spare. 4. Luminaire switch. Lighted switch indicates power to luminaire. 5. In and out remote 0-10 volt dimming signal ( BNC). 6. Local (manual) dimming control and local / remote switch. 7. Suspension adjustable yoke provides 70 dgr. altitude and 360 dgr. azimuth pointing. 8. Lens/reflector assembly which concentrates 4 watt high brightness LED's output. 9. Palm bolts allow tilt adjustment. table 1 p2 LED31-11onmp2.pdf

LED31-11onmp3.pdf LED31 shown with the standard "Near" gel frame and honeycomb holder. Mounted to it is the optional "Extender Kit" which will retain a honeycomb and a gel frame in the "Far" position. The extender kit is furnished complete with fasteners and an Allen wrench. It is factory assembled when ordered with fixtures. "near" gel-honeycomb slot (incl.) Extender kit gel-honeycomb "far" aperture fig. 4 extender posts Stand or suspension mount ACCESSORIES The proper use of accessories will allow this luminaire to operate as a highly specular key light and as a directional soft light source and every point in between. (fig 5&6) The LED-31-11 provides a slot at the aperture which will hold a gel frame and a honeycomb. With it's 11 degree beam angle the LED- 31-11 is suitable for distant front and back light applications as well as key light and multiple back light applications through the use of shaping gels. (fig 8) Shaping gels also allow for minimum flair onto monitors or provide for standing talent illumination. (fig. 7) Honeycombs and gels with laminated frames are available for the basic LED-31-11 and fit into the furnished aperture slot. Laminated gels as well as bare gel frames are available to allow use of non-standard gels. The most effective use of the LED-31-11 for front light, key light and soft fill light is with the extender honeycomb-gel accessory kit. (fig 4) The placement of gels in the "far" position provides for beam overlapping and gives the appearance of a single source of light while eliminating multiple shadow effects. Honey combs eliminate side glare and make for easier tele-promptor perception. Laminated gel assemblies are available for the larger far aperture position as well as bare frames. fig. 5 fig. 6 fig. 7 fig. 8 p3

INSTALLATION: Remove the luminaire from the shipping carton and inspect for any damage during shipping. If attenuators are ordered they may be installed in the aperture. If so, loosen the accessory slot cover retaining screws and slide the cover back to expose the slot. It is advisable to bench test the fixtures before installation but a few precautions are in order. Make certain that the fixture cooling slots are not blocked when lit. Adjust the yoke so that the body of the fixture is tilted when on the table. This is important because the LEDs are cooled by convection of air through the body of the fixture. Do not block the vent slots. Do not place the fixture horizontal or mount with the yoke horizontal as overheating can occur which will shorten fixture life. When testing the fixture up close make certain not to look directly at the light sources from close proximity. It is good practice to install the filters to be used before turning on the luminaires. Install the power cord and plug into 120 volt service. Place the fixture so as not to block the cooling vents and turn on the switch.the fixture has a 2 second delay on starting. If the fixure has power the switch will be lit. The LED-31-11-DAN version may be dimmed with 0-10 volt signal via the BNC connectors and one signal source may dim a number of fixtures by connecting fixtures together with BNC cables. DMX signals may be decoded to produce 8 or more individual channels per shoebox decoder equipped with BNC outlets. Each channel is considered a separate signal source. Local dimming control is provided by a dimmer controller with a local / remote selector switch. Next, the hanging means should be mounted on the yoke with a 1/2" bolt supplied with the "C" clamp and or stem. With the stems and clamps attached, hang each assembly in the desired location on the 2" pipe grid or other qualified hanging system. Immediately add a safety cable as per fig. ( 9 ) The light sources cannot be changed in the field. Contact the factory for assistance. (214)-393-5998, fax 393-5999 OPEN BOLT TO CLEAR PIPE TIGHTEN BOLT AGAINST PIPE fig 9 SECURE CLAMP TO BALE SECURE SAFETY CABLE PrimeTime L i g h t i n g S y s t e m s R led31-11omp4.pdf Manufactured in the USA by: PL Systems, Inc. 10529 Olympic Drive Suite 102 Dallas, TX 75220 (214)-393-5998 p4

LD3.-11ONMp5.PDF FUSE REPLACEMENT FOR FIXTURES WITH DETACHABLE POWER CORDS. A B spare active fuse fig. 10 DIRECTIONS Fixtures equipped with detachable power cords contain fuses which are rated at 6 Amps @ 125 Vac. To replace fuse remove power cord exposing the receptacle as shown in fig. 10. Make certain there are no other cords attached to the fixture. Using a small flat screw driver, pry up the fuse holder shown in figure 10. Replace the fuse in the active slot and snap the fuse holder back into place. Use only fast acting type 217, 5 x 20 mm, 6 amp fuses. LINE POWER SCHEMATIC LED-31 black 6 A fuse switch white LED POWER SUPPLY switch indicator light POWER OUTLET fig. 11 CAUTION Fused power out receptacle to be used for studio lights only. Maximum string wattage is 400. Fast acting fuse type 217, 5 x 20 mm, 6 Amps, 125 V. p5 PL Systems, Inc.10529 Olympic Drive Dallas, TX 75220 (214)-393-5998.