Sump / Effluent Pump

Similar documents
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC3000 / Item #40885

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

GARDEN HOSE UTILITY PUMP

PRE-PLUMBED SEWAGE SYSTEM

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

THERE IS NO OTHER EXPRESS WARRANTY.

AUTOMATIC SUBMERSIBLE UTILITY PUMP

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

ESE Series Cast Iron Sewage Pumps

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

Submersible Effluent Pump

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

Matala. VersiFlow Series. Instruction and Maintenance Manual

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

StormPro BA Series Sump Pump

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

General Safety Information

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

Submersible Sewage Ejector Pump

STEP-BY-STEP INSTALLATION GUIDE

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

GeyserMax-Flow Series

SHALLOW WELL JET PUMP

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

STAR STOP SHALLOW WELL JET PUMP

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

StormPro BCV400 Sewage Ejector Pump

HALLMARK INDUSTRIES INC

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

SUPER PUMP OUT SYSTEM

END SUCTION CENTRIFUGAL PUMPS

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Sealless Centrifugal Canned Motor Pumps

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation & Operating Manual

Ion Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

INSTALLATION & OPERATION MANUAL

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

2SHE Series Direct-Drive Shutter Fans

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

LAWN SPRINKLER, IRRIGATION PUMP

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Powerful & Intelligent Submersible Pumps

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Operating Manual Includes Pumps: PG-9000 Part #R809606

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

SHEF30 Submersible Sump/ Effluent Pump

SUBMERSIBLE PUMP HSE RANGE

END SUCTION CENTRIFUGAL PUMPS

SUBMERSIBLE PUMP HSE RANGE

M-3025CB-AV Fuel Pump

FP0S2300X FP0S3000X. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

SUBMERSIBLE MINI-PUMP

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

Owner s Manual Drill and Light Weight Portable Utility Pumps

Installation Operation Parts

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

ARAG Modular Electric Valve Operating Instructions and Parts Manual

XLE100/150 Series Explosion-proof Submersible Sewage Pumps

Ion Technologies SEF100-SEF200 Heavy Duty Sewage Pumps

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Submersible Solids Handling Pumps

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Unilift KP 150, KP 250, KP 350

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

MODEL H INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

SP40 Submersible Sewage Ejector Pump

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Rechargeable Inflator

Pump Installation and Service Manual SHEF50/SHEF100 Submersible Effluent Pump

STOCK No. 53DH04 MODEL 6EC-CIA-SFS STOCK No. 53DH05 MODEL 6EC-CIM STOCK No. 53DH06 MODEL 10EC-CIA-SFS. Installation Guide

Transcription:

Operating Instructions and Parts Manual SEF40V, SEF40V-2, SEF40T, SEF40T-2, SEF40D, SEF40D-2, SEF40M The Professional s Line Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Sump / Effluent Pump Description A sump/effluent system consists of a pump, control switch and a basin. The system may be controlled by a float switch with one of the following kinds of plugs: Models SEF40D, SEF40D-2, SEF40V, SEF40V-2, SEF40T, and SEF40T-2: piggyback-style plug (which accepts the pump plug) or Model SEF40M: standard plug (which uses internal wiring) The system will use one of the following kinds of switches: Models SEF40V and SEF40V-2: Vertical Mechanical Switch; Models SEF40T and SEF40T-2: Mechanical Float Switch; or Models SEF40D and SEF40D-2: Diaphragm Switch Specifications Power supply requirements...........120v, 60 hz Circuit requirements.....15 amps (min) Motor duty............intermittent Motor................120V, 1 Phase, 3000RPM Liquid temperature range.................40 F to 125 F Max. operating position..45 o from vertical Dimensions............9" x 10" Discharge..............1-1/2" Power cord............18 gauge 3 conductor w/plug Construction Pump housing...cast iron Impeller...Glass reinforced ABS Inlet Cover...Stainless Steel Shaft seal...rubber Shaft Seal Performance GALLONS PER MINUTE AT TOTAL HEAD IN FEET Model 10 15 20 25 SEF40 41 29 14 0 2007 Blue Angel Pumps This pump is intended for use in domestic sump or effluent lift stations. It is suitable for pumping effluent, wastewater, ground water and other nonexplosive, noncorrosive liquids with up to 1/2" solids. Sump / effluent pump will not pump raw sewage or any substance exceeding 1/2 size. This pump is not designed to handle salt water, brine, laundry discharge, or any other application which may contain caustic chemicals and/or foreign materials. Pump damage could occur if used in these applications and will void warranty. Unpacking Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death. Performance Curve SEF40V SEF40T SEF40D SEF40M Rating 4/10 HP, 8.3 A 4/10 HP, 8.3 A 4/10 HP, 8.3 A 4/10 HP, 8.3 A Switch Vertical 90 o Wide Angle Diaphragm Manual Mechanical Mechanical Switch Operation Switch Float Switch Cut-in level (factory set) 7.5" 12.5 12" Cut-out level (factory set) 3.5" 4 4.5" REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. For parts, product & service information visit Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Notice indicates important information, that if not followed, MAY cause damage to equipment. 330405-002 12/07

Operating Instructions and Parts Manual General Safety Information CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. GENERAL 1. Know the pump application, limitations, and potential hazards. Do not use unit to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. Use pump only with liquids compatible with pump component materials. Failure to follow this warning can result in personal injury and/or property damage. This pump contains dielectric motor oil for motor heat transfer. Care should be taken when disposing of this oil. Do not use this pump in ponds or fountains because the motor oil can be harmful to aquatic life. 2. Make certain that the power source (electric motor) conforms to the requirements of the equipment. Disconnect power before servicing. If the power disconnect is out of sight, lock in the open position and tag it to prevent unexpected application of power. Failure to do so could result in fatal electrical shock! 3. Release all pressure within the system before servicing any component. 4. Drain all liquids from the system before servicing. 5. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage. 6. Check hoses for weak and worn condition before each use, making certain that all connections are secure. 7. Periodically inspect the pump and system components. Perform routine maintenance as required (See Maintenance Section). 8. Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed. 9. Personal Safety: a. Wear safety glasses at all times when working with pumps. b. Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment. c. Keep visitors a safe distance from the work area. Make workshop child-proof with padlocks, master switches, and by removing starter keys. 10. When wiring an electrically driven pump such as this, follow all electrical and safety codes, as well as the most recent National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). Risk of electric shock! Never connect the green (or green and yellow) wire to a live terminal! 11. This equipment is only for use on 120 volt (single-phase) and is equipped with an approved 3-conductor cord and 3-prong, grounding-type plug as shown in Figure 1. Grounding Blade Figure 1 TEST RESET To reduce the risk of electric shock, the motor must be securely and adequately grounded. This can be accomplished by inserting plug directly into a properly installed and grounded 3-prong, grounding-type receptacle (as shown in Figure 1). Risk of electric shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electric shock. Never cut off the round grounding prong. Cutting the cord or prong will void the warranty and make the pump inoperable. Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with the NEC and local codes and ordinances. 12. All wiring should be performed by a qualified electrician. 13. It is strongly recommended that this unit is plugged into a Ground Fault Circuit Interrupter (GFCI). Consult a local electrician for installation and availability. The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor conditions, or a defective motor or pump. 14. Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately. Use wire of adequate size to minimize voltage drop at the motor. 15. Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water. 16. Do not hang this product by the carry handle. Sump/effluent pumps should be set firmly on their legs and supported by rigid piping. This eliminates twisting and damage during pump operation. 17. Do not use an extension cord. Do not walk on wet area until all power has been turned off. If the shut-off box is in basement, call the electric company to shut-off service to the house, or call the local fire department for instructions. Remove pump and repair or replace. Failure to follow this warning can result in fatal electrical shock. 2

SEF40V, SEF40V-2, SEF40T, SEF40T-2, SEF40D, SEF40D-2, SEF40M Installation In any installation where property damage and/or personal injury might result from an inoperative or leaking pump due to power outages, discharge line blockage or any other reason, use a backup system(s). 1. Thread the discharge pipe or pipe nipple into the discharge connection. 2. If a check valve is used, mount the check valve in a horizontal position or at a 45 angle with the valve pivot on top. In a vertical position, solids will tend to lodge on the valve flapper and can prevent it from opening. 3. Drill a 1/16" hole in the discharge pipe approximately 1" to 2 above the pump discharge when a check valve is used. The hole prevents air locking of the pump at the initial start-up and if it should lose prime. 4. A gate valve should be installed in the system after the check valve. This gate valve should be a full port valve which will pass 1/2" solids or as required by state and local codes. This gate valve permits removal of the pump and/or check valve for servicing. 5. A union should be installed between the check valve and the pump so the pump can be removed with least disturbance of the piping. 6. If the pump has a detachable mechanical float switch with a piggyback-style plug, the length of the tether (distance of cord from float to clamp) should not be set shorter than 3-1/4" and should not be used in a basin smaller than 14" in diameter. If using a differential other than the factory setting, be sure when the pump shuts off at least 4 of fluid is left in the basin so the impeller remains submerged. 7. When a mechanical float switch is used, rigid discharge pipe is required. If the pump is allowed to move, the mechanical float switch could be restricted by the basin wall, preventing the pump from operating. Before removing pump from basin for service, always disconnect electrical power to pump and control switch. For any work on pump or switch, ALWAYS unplug the power cord. Do not just turn off circuit breaker or unscrew fuse. Main waste line to sewer or septic tank Three prong grounded outlet equipped with a ground fault interruptor Sump / effluent pump passes 1/2 inch dia. solids Maintenance Make certain that the pump is unplugged before attempting to service or remove any component. This pump is assembled in the factory using special equipment; therefore only authorized service dealers or qualified electricians should attempt to repair this unit. Improper repair can cause an electrical shock hazard. The pump contains oil that may be under pressure because of heat. Let the pump cool for a minimum of two hours before servicing this unit. 1. Disassembly of the motor prior to expiration of warranty will void the warranty. It might also cause internal leakage and damage to the unit. If repairs are required, return the pump to the dealer from whom it was purchased or call 1-888-636-6628. If motor is ever disassembled the O-rings must be replaced. Care must be taken to ensure that all seals do not leak. 2. After the basin cover is removed and necessary discharge piping disconnected, lift pump from basin. 3 2 inch Discharge pipe 2 inch Gate Valve Figure 2 - Typical Installation 45 o Elbow Union 2 inch Check Valve Upper level drainage Flange Cleanout Vent pipe 3. Pump should be checked on a regular basis for proper operation. If anything has changed since unit was new, the unit should be removed and repaired or replaced. Only qualified electricians or service people should attempt to repair this unit. Improper repair and/or assembly can cause an electrical shock hazard. 4. Place the pump in a suitable area where it can be cleaned thoroughly. Remove all scale and deposits on pump. 5. Submerge the complete pump in a disinfectant solution (10% chlorine bleach solution) for at least one hour before handling the pump. 6. Clean all dirt and deposits from the pump float. Make sure float moves freely after cleaning. 7. Clean all dirt and deposits away from pump inlet and volute.

Operating Instructions and Parts Manual Troubleshooting Chart Pump may start unexpectedly. Disconnect power supply before servicing. Symptom Possible Cause(s) Corrective Action Pump will not start or run Pump starts and stops too often Pump shuts off and turns on independently of switch (trips thermal overload protection) Pump operates noisily or vibrates excessively Pump will not shut off Pump operates but delivers little or no water 1. Blown fuse or tripped circuit breaker 2. Low line voltage 3. Defective motor 4. Defective float switch 5. Impeller (pump filled with debris) 6. Tangled switch 7. Insufficient liquid level 1. Backflow of water from piping 2. Faulty float switch 3. Check valve not installed or leaking 4. Discharge head is less than manufacturer's minimum 1. Excessive water temperature 2. Defective switch or entangled switch is causing pump to run dry 3. Low line voltage 1. Worn bearings 2. Debris in impeller cavity or broken 3. Piping attachments to building structure too rigid or too loose 1. Defective float switch 2. Float switch movement restricted 3. Restricted discharge (obstruction in piping) 4. Excessive inflow or pump not properly sized for application 1. Low line voltage 2. Debris caught in impeller or discharge 3. Worn or defective pump parts or plugged impeller 4. Pump running backwards 5. Pump not properly sized for application 6. Check valve stuck closed or installed backwards 7. Shut off valve closed 1. If blown, replace with proper sized fuse or reset breaker 2. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company. 3. Return for service or replace motor 4. Replace float switch 5. If impeller will not turn, remove housing and remove debris 6. Arrange switch so the switch moves freely. Reposition pump if necessary 7. Make sure liquid level is at least 13" from the basin floor 1. Install check valve 2. Replace float switch 3. Remove and examine check valve for proper installation and free operation 4. Recheck all sizing calculations to determine proper pump size 1. Pump should not be used for water above 120 2. Replace or reposition pump 3. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company 1. Return for service or replace 2. Remove Inlet Cover, clean impeller and/or replace broken impeller 3. Replace portion of discharge pipe with flexible connector 1. Replace float switch 2. Reposition pump or clean basin as required to provide adequate clearance for float 3. Remove pump and clean pump & piping 4. Recheck all sizing calculation to determine proper pump size 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company 2. Remove, clean and check for tightness 3. Replace worn parts or entire pump. Clean parts if required 4. Check rotation. (CCW from bottom) Return if CW 5. Recheck all sizing calculations to determine proper pump size 6. Remove and examine check valve for proper installation and free operation 7. Open valve 4

SEF40V, SEF40V-2, SEF40T, SEF40T-2, SEF40D, SEF40D-2, SEF40M For Replacement Parts, call 1-888-636-6628 Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address parts correspondence to: Blue Angel Pumps 101 Production Drive Harrison, OH 45030 U.S.A. 9 8 MECHANICAL FLOAT SWITCH PARTS 7 10 2 1 3 5 6 VERTICAL MECHANICAL SWITCH PARTS 11 4 DIAPHRAGM ASSEMBLY Replacement Parts List Ref. No. Description Number Qty. 1 Impeller 28456-001 1 2 #8 x 32 Screw 16353 1 3 Inlet Cover 46033-001 1 4 #10 x 24 Screw 67050-001 1 5 Stone Guard 46041-001 1 6 Vertical mechanical switch bracket (SEF40V and SEF40V-2) 46035-001 1 7 Vertical mechanical switch (SEF40V) 30016-001 1 7a Vertical mechanical switch (SEF40V-2) 30022-001 1 8 Mechanical float switch (SEF40T) 30000-001 1 8a Mechanical float switch (SEF40T-2) 30000-003 1 9 Mechanical float switch clip (SEF40T and SEF40T-2) 67013-001 1 10 Lifting ring 47008-001 1 11 Diaphragm assembly (SEF40D) 60098-BLA1 1 11a Diaphragm assembly (SEF40D-2) 60099-BLA1 1 5

Operating Instructions and Parts Manual Notes Notas 6

SEF40V, SEF40V-2, SEF40T, SEF40T-2, SEF40D, SEF40D-2, SEF40M Notes Notas 7

Operating Instructions and Parts Manual SEF40V, SEF40V-2, SEF40T, SEF40T-2, SEF40D, SEF40D-2, SEF40M Limited Warranty For two years from the date of purchase, Blue Angel will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps ( Product ) found upon examination by Blue Angel to be defective in materials or workmanship. Please call Blue Angel (1-888-636-6628) for instructions or see your dealer. Be prepared to provide the model number and the serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Blue Angel s written instructions. THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Blue Angel or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer s customers for such damages. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Blue Angel (1-888-636-6628) for return authorization and instructions. DO NOT MAIL THIS FORM TO BLUE ANGEL. Use this form only to maintain your records. MODEL NO. SERIAL NO. INSTALLATION DATE ATTACH YOUR RECEIPT HERE 8