SIL Inline Single Stage Centrifugal Pumps

Similar documents
SNS End Suction Single Stage Centrifugal Pumps

AHLSTAR End Suction Single Stage Close Coupled Centrifugal Pump

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

CPE end-suction single-stage centrifugal pumps ASME B73.1

Slurry pump type Ensival Moret PLR and CR

AGISTAR TM SSA Side-Mounted Agitators

Axial Flow Pump Type Ensival Moret CAHR

Heavy Duty Slurry Pumps Type Ensival Moret EMW

MBN Multistage Ring Section Pumps

MBN Medium Pressure Stage Casing Pump

SMD axially split casing, double suction pump

PC Transfer Perform Pump

Municipal Water Treatment, Supply and Distribution

AHLSTAR end suction single stage centrifugal pumps

Submersible Grinder Pumps Type ABS Piranha

Submersible Sewage Pumps Type ABS XFP

SJT/SJM CWP Vertical Pump

Submersible Sewage Pumps Type ABS XFP

OCV and OCVL API 610 Type VS4 Sump Pumps

SJP Vertical Propeller Pumps

API 610 Vertical Multistage Pumps

MBN Multistage Ring Section Pumps

ZE/ZF Process Pump API 610

ISO 2858 Back Pullout End Suction Centrifugal Pumps

Flow Boosters Type ABS SB

MSD Axially Split Multistage Pump

TP /4-A-F-A-BUBE 400Y 50HZ

Contents. Identification

TP /2-A-F-A-BAQE 400D 50HZ

Sulzer Pumps for Nickel Applications

OHV and OHVL Vertical Inline Pumps ISO (API 610)

TP /4-A-F-A-BQQE 400Y 50HZ

Sulzer Pumps for Copper Refining Applications

MSD Axially Split Multistage Pump

NB /193 A-F2-A-BAQE

Company name: BKB Building Solutions Created by: Michael Chlopek Phone: Date: 13/03/2017

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

Hydro MPC-E 2CRIE L GNL

THE LEADING FORCE behind liquids since 1857

Blockpumps. Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858

CM5-5 A-R-A-E-AVBE F-A-A-N

The e-nsc End Suction Pump Series

MD High Pressure Stage Casing Pump

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

Sulzer Pumps for Zinc Refining Applications

TP /2-A-F-A-BQQE 400D 50HZ

High-Temperature and Pressure Paper Stock / Process Pump

4WN. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE MULTISTAGE PUMPS. Pag

TP 32-90/2-A-O-A-BQQE 400Y 50HZ

franklinwater.com 50 Hz 6" STS SERIES Submersible Turbine Pumps

DESMI 48 Fast Track. Pump Replacement Within 48 hours PROVEN TECHNOLOGY

PS/PSL Centrifugal pumps

TP /2-A-F-A-BUBE 1X230 50HZ

CM10-3 A-R-A-E-AVBE F-A-A-N

TP /2-A-F-A-BQQE 400D 50HZ

BULLETIN January Goulds Model 3700 API th Edition/ISO Process Pumps

CM10-1 A-R-A-E-AQQE F-A-A-N

High Temperature Chemical Process Inline Pumps

Peerless Pump FULL PRODUCT LINE. Brochure B Sterling Fluid Systems (USA), Inc.

CPT ANSI Process Pumps

Axial and Mixed Flow Pumps for Large Volume Pumping

CM1-2 A-R-A-E-AQQE F-A-A-N

GSG Diffuser Style Barrel Pump ISO (API 610) Type BB5

ST, XT & SU SELF PRIMING PUMPS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

Goulds High-Pressure Multi-Stage Pumps

CombiNorm. Centrifugal pump according to EN 733 (DIN 24255)

CRK 2-60/6 AWA-BUBV 075KW 3X400V 50HZ

General Catalog. A New Vision for Quality Pumps. General Catalog

TPED /4-A-F-A-BQQE 3X400 50HZ

CM1-6 A-R-I-E-AQQE F-A-A-N

PWA-IL B73.2 IN-LINE

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

ANSI Centrifugal Process Pumps. 911 Series

Company name: Created by: Phone:

T100 Series Medium Pressure Models T100K & T100M

Goulds LF 3196 i-frame. Low Flow ANSI Process Pump with i-alert Patented Intelligent Monitoring

ANDRITZ High-Pressure Pump MP Series

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Volute Casing Pumps LSN. according to iso 2828 / ISO 5199

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

MC High Pressure Stage Casing Pump

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

Company name: Created by: Phone:

NB /438 A-F1-A-GQQE

TP 25-80/2-A-O-A-BQQE 400Y 50HZ

FE Frame-Mounted End Suction Pumps. Leading The Flow. TACO.

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

KS / SKS Vertical Split Coupled Inline Pumps

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

G&L Series MPVN. High Pressure Multi-Stage Pumps. Goulds Pumps. ITT Industries

PWA-LF LOW FLOW ANSI PROCESS PUMP

BBT/BBT-D Two Stage Radially Split Between Bearings Process Pump API 610, 9th Edition (ISO 13709)

INDUSTRY APPLICATION. S -pumps are used in: Industry Waste treatment Environment protection Construction industry Civil engineering

CRN5-8 A-P-G-V-HQQV 3x230/400 50HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

Transcription:

SIL Inline Single Stage Centrifugal Pumps

SIL Inline Pump Range True Reliability Sulzer s new inline pump range (SIL) has been designed to fulfill efficiency regulations across all industries and also the design requirements of the ISO 5199 international standard. Inline design with integrated motor construction makes the pump compact and easy to install reducing the total cost of ownership. Main Applications The SIL pump range has been designed to meet the process requirements in versatile general and industrial applications to pump clean and slightly contaminated liquids viscous liquids up to 250 cst fibrous slurries up to 1% consistency Key Customer Benefits The SIL pump range has been designed using our long experience and in-depth knowledge of how to maximize value for our customers. Key benefits include: Premium efficiency The inline pump exceeds the EU s (European Union) requirements for energy-related products (ErP) The whole pump range exceeds MEI 0.4 (Minimum Efficiency Index) First class reliability The pump construction is optimized for clean liquid applications to maximize the lifetime of the pump Monoblock construction means compact, rigid and reliable design eliminating the need for a bearing unit. This minimizes the wearing parts and need for maintenance. Optimized shaft seal chamber and balancing holes guarantee improved conditions for the shaft seal maximizing its life time ErP 2015 MEI 0.4 Minimized total cost of ownership (TCO) Low energy consumption due to high efficiency Low operational costs, low spare parts costs and minimized service due to trouble-free monoblock construction Low installation and maintenance costs due to easy installation and simple design 2

SIL Inline Single Stage Centrifugal Pumps Oil and gas Hydrocarbon processing Power generation Pulp and paper General industry Chemical process industry Water and wastewater Operating data 50 Hz 60 Hz up to 720 m 3 /h Capacities up to 3,200 USgpm up to 100 m Heads up to 328 ft up to 16 bar Pressures up to 230 psi up to 180 C Temperatures up to 356 F up to 3,600 rpm Maximum speed of rotation up to 3,600 rpm Performance ranges Q (m 3 /h) H (m) 2 5 10 20 40 100 200 400 1000 120 100 40 20 10 5 2 1 0.2 0.5 1 2 With integrated motor 5 10 20 40 100 200 Q (l/s) Q (m 3 /h) H (m) 20 30 40 50 100 200 400 1000 100 40 20 10 5 2 1 0.5 5 10 20 30 4050 100 200 300 Q (l/s) With IEC motor 3

Premium Efficiency and Monoblock Construction Improve Reliability and Minimize Total Cost of Ownership 1 Simple, compact and heavy duty monoblock construction No bearing unit no maintenance of bearings needed minimizing maintenance costs Rigid construction with short shaft minimizes vibrations maximizing pump and seal lifetime Reduces maintenance and spare parts costs 2 Rigid, high efficiency, low NPSHr (Net Positive Suction Head required) impeller Reduced total cost of ownership, especially energy consumption and operational downtime costs 3 Classic keyway impeller mounting Long support between the shaft and impeller minimizes vibration Enables easy and quick dismantling and reassembly Minimizes maintenance costs 6 4 Large variety of mechanical shaft seals Single and double mechanical seals Reliable and trouble-free operation Easy and quick assembly and dismantling Reduces total cost of ownership by minimizing maintenance and downtime costs 5 Optimized sealing lubrication Large bore seal chamber and impeller balancing holes guarantee the right flow and pressure in the shaft sealing area Improves seal life time, reduces unexpected shutdowns and minimizes maintenance costs 6 High efficiency integrated low voltage motors Large power range available IE3 efficiency class available Suitable for frequency converter use Impeller mounting directly onto motor shaft Reduces total cost of ownership by minimizing energy consumption 1 7 Quick and easy installation Can be installed without a base plate between the piping depending on the motor size SIL pumps with integrated motor can be installed both vertically and horizontally on the basis of the piping arrangement No need for base plate grouting No need for motor/pump alignment Needs small space due to compact design Reduces total cost of ownership by minimizing installation costs 2 8 Highly standardized pump design Minimizes spare parts inventory and saves maintenance costs 4

9 SIL with high efficiency IEC standard motor The motor is installed to the pump with an adapter The motors are flange mounted IEC standard motors Large power range available IE2, IE3 and IE4 efficiency classes available Suitable for frequency converter use Impeller mounting onto a flange shaft which is connected to the motor shaft with a coupling Reduces total cost of ownership by minimizing energy consumption SIL with IEC standard motor 4 3 5 8 SIL with integrated motor 7 5

High Efficiency across the Whole Pump Range, Exceeding MEI 0.4 Energy efficiency is a hot topic in industry. So important that the European Union (EU) has created ErP (Energy-related Products) regulations specifying minimum efficiency values for water pumps, with the target of reducing energy consumption. From now on, only pumps and motors which satisfy the energy efficiency requirements of the EU s ErP Directive may be sold. MEI 0.7 0.6 0.5 0.4 0.3 0.2 Minimum MEI limit SIL 0.4 MEI, the minimum efficiency index for standardized water pumps, was set up to be 0.4 since the beginning of 2015. This means that at present 40% of the pumps on the market do not comply. Sulzer s SIL pump range fulfills the requirements of ErP and the requirements of all other industrial efficiency regulations. 0.1 0.1 January 1, 2013 January 1, 2015 Materials Standard material options Material Cast Iron ASTM A48 CL30 ENGJL200 Ductile Iron ASTM A536 ENGJS400 Austenitic ASTM A743 Grade CF-8M Austenitic ASTM S31254 SS2378 254 SMO Duplex SS ASTM A890 Grade 3A Bronze ASTM B505 CuSn10Zn2 6

Impeller The efficiency, stability and reliability of the pump are based on the design. The impeller is designed in tandem with the casing and seal chamber. The result is efficient hydraulics with reliable shaft sealing ensuring higher reliability. The closed impeller is designed to suit versatile liquids maximizing standardization and minimizing the need for spare parts. Design Closed impeller for clean and slightly contaminated liquids High efficiency Low net positive suction head required (NPSHr) Sturdy and strong design Optimized balancing holes Impeller balancing holes guarantee optimized flow and pressure in the shaft sealing area Dry running of the single mechanical seal is eliminated across a wide operating area Increased reliability and lower downtime and maintenance costs Keyway impeller mounting Easy and quick dismantling and assembly Allows reverse rotation Minimizes downtime and maintenance costs 7

Shaft Seals Large variety of mechanical shaft seals for maximizing operational reliability and minimizing downtime costs. The shaft seal is selected according to the application to ensure reliable shaft sealing. A large bore seal chamber guarantees optimal conditions and good lubrication for the seal faces. There is a large variety of shaft seals to fulfill the needs of various pumping conditions. Mechanical seals are installed directly on the shaft and are easy and fast to install. Single mechanical seal Positive inlet pressure is required The seal faces are lubricated by the pumped liquid flowing through the impeller balancing holes into the seal chamber Suitable for clean and slightly contaminated liquids Temperature 10 C / 20 F below the boiling point of the pumped liquid at atmospheric pressure, max. 120 C / 250 F Single mechanical seal with recirculation flushing The seal faces are lubricated by the pumped liquid circulated through a pipe from the discharge pipe into the seal chamber Suitable for clean liquids, water and condensates Temperatures up to 150 C / 300 F Single mechanical seal with external clean flushing The seal faces are lubricated by external clean flushing liquid fed through a pipe from an external source into the seal chamber Suitable for clean and slightly contaminated liquids as well as viscous liquids External flushing is mixed into the pumped liquid Temperatures up to 180 C / 356 F Double mechanical seal with external sealing liquid The seal faces are lubricated by non-pressurized (quench) or pressurized (barrier) external clean sealing liquid fed through a pipe from an external source into the seal between the seal face pairs Designed for clean and slightly contaminated liquids as well as viscous liquids Temperatures up to 180 C / 356 F 8

Sealing Water Equipment Sealing water equipment regulates the volume and pressure of external sealing water for optimum shaft seal performance. The equipment is attached directly to the supply connection using a hose. Sealing water equipment for external flushing Single mechanical seals The pressure of incoming water supply must be at least 0.5 bar / 7 psi higher than the pressure in the seal chamber The volume of sealing water can be regulated by the control valve on the sealing water equipment, typical value is 3 l/min / 0.8 USgpm Sealing water equipment for non-pressurized (quench) sealing water Double mechanical seals The pressure of incoming water supply must be positive The volume of sealing water can be regulated by the control valve on the sealing water equipment, typical value is 3 l/min / 0.8 USgpm Sealing water equipment for pressurized sealing water Double mechanical seals The pressure of incoming water supply must be at least 0.5 bar / 7 psi higher than the pressure in the seal chamber The volume and pressure of sealing water can be regulated by the control valve on the sealing water equipment, typical value is 3 l/min / 0.8 USgpm 9

Drive motor SIL pumps are of a monoblock construction. They are equipped either with an integrated AC motor or with an IEC standard motor. Integrated motor construction The motor is integrated into the pump The impeller is installed directly onto the motor shaft without any coupling Available efficiency grades IE3 Available power range 0.05-160 kw Available in 2-pole and 4-pole models The motor is VFD compatible The pump and motor combination is very compact and quick to install Pumps equipped with a max. 15 kw motor can be installed between the pipes without additional support or base plate IEC standard motor construction The motor is an IEC standard low voltage flange mounted AC-motor The motor is installed to the pump with an adapter The impeller is installed to a flange shaft which is connected to the motor shaft with a coupling Available efficiency grades IE2, IE3, IE4 Available power range 4-110 kw Available in 2-pole and 4-pole models The motor is VFD compatible The pump and motor combination is compact and quick to install 10

Key Design Features - Installation, Operation and Maintenance 1 SIL pumps with integrated motor <15 kw can be installed between the pipes without additional support or base plate Easy and fast to install minimizing installation costs Vertical and horizontal installation is allowed 2 Steel base plate installed onto a free moving concrete plinth For pumps equipped with integrated motor > 15 kw and all IEC motor versions Easy and fast to install minimizing installation costs 3 Monoblock construction No need for additional bearing unit No need for coupling alignment Needs minimized installation space for the pump and motor Minimizes installation and maintenance costs and also ensures safe and reliable operation 4 Coupling guards for the rotating parts are designed according to stringent safety regulations Ensures safe and reliable operation 5 Back pull-out design facilitates quick access for servicing without detaching the pump from the piping 5 3 4 1 2 11

www.sulzer.com E10385 en 10.2016 (2,000), Copyright Sulzer Ltd 2016 This brochure is a general presentation. It does not provide any warranty or guarantee of any kind. Please, contact us for a description of the warranties and guarantees offered with our products. Directions for use and safety will be given separately. All information herein is subject to change without notice.