MODEL 10LH SPECIFICATION

Similar documents
MODEL 5A SPECIFICATION

MODEL 7ASX-8 SPECIFICATION

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

Series CC Condensate Units

ROGERS MACHINERY COMPANY, INC

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

Duplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, with Steel Cover

Simplex Jobsite Wired Basin Package Non-Sparking Stainless Rail Non-Sparking, Class I, Group D, Division 1, w/fiberglass Cover

SECTION HYDRAULIC FOUR FOLD DOORS MODEL 48 LOUVERS

Sample Specifications 2110_KA.DOC KOBELCO KNW SERIES 1 OF 10 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame 0, 1, HP

radial GATES Waterman Industries of Egypt

Hydropak Booster Systems. Series motralec

Series MSC Sewage Chopper Pumps

BSM ROTARY GEAR PUMPS

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

CLARK SOLUTIONS S Series Rotary Gear Pump Pressure to 200 PSI, Flow to 32 GPM, Drive Speed to 1800 RPM

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Sample Specifications 2111_A00.doc 01/18/06 KOBELCO KNWA00 SERIES 1 of 8 AIR-COOLED, OIL FREE AIR COMPRESSOR Frame HP

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

MODEL MC1500 Installation and Operation Manual Important:

ROLLER GATES. Waterman Industries of Egypt. Roller gates are nominated for heavy duty service where large loads and sizes are going to be encountered.

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

Deep Well Pump Control Valve

Instruction Bulletin. Jockey Pump Controller

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

Use Type C control units. Viscosity range is 100 to 10,000 SSU at operating temperature. See Bijur Engineering Manual for system limitations.

PATTERSON PUMP COMPANY

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

SPECIFICATIONS. General Specifications. Dimensions

E Series Electric Actuators

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

ROGERS MACHINERY COMPANY, INC

Mizer Single Pump and Starter Box

MOHAWK MODEL TR-110 / 30 SPECIFICATIONS HEAVY DUTY FOUR POST DRIVE-ON VEHICLE LIFT

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Regenerative Turbine Pumps

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

Packaged Design Day Tank Systems

Design Standard. Purpose: Design Standard:

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Direct Gas-Fired Heating

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

Regenerative Turbine Pumps

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

LITERS PER MINUTE GALLONS PER MINUTE

Series 774 Automatic Skid Package

VIKING SG SERIES SINGLE PUMPS (WITH SHAFT SEAL)

BSM ROTARY GEAR PUMPS

TIN KNOCKER TK H1652 Hydraulic Shear

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Technical Information for PVX Series Pumps

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

BSM ROTARY GEAR PUMPS

Low Profile J Series Power Unit with Vane Pump

earth safe Fuel Systems for Critical Power

FreezeFree TM Nitro Anti-Icing System GENERAL SPECIFICATIONS

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES

LUBE OIL PUMPS. Critical Lubrication Service for: Bearings Seals Gearboxes. on... Gas & Steam Turbines Compressors Engines Starting Packages

Regenerative Turbine Pumps

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

VIKING SG SERIES SEALLESS MAG DRIVE PUMPS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

University of Houston Master Construction Specifications Insert Project Name

D51 D61 D71 D91 Series

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

To ensure proper installation, digital pictures with contact information to before startup.

Construct Compressed Air Building Near Bldg SECTION OVERHEAD COILING DOORS 07/07

CEILING AIR INLETS CORROSION PROOF ECONOMICAL DURABLE. Ideal for all Agricultural applications.

MODEL SCA Installation and Operation Manual Important:

Regenerative Turbine Pumps

Regenerative Turbine Pumps

StopGate TM Barrier Arm GENERAL SPECIFICATIONS

M50 L50 Series Multistage Regenerative Turbine Pumps

Doorway Foamer. Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, Phone Fax

DAKE / JOHNSON VERTICAL BAND SAW

W4100, W4200 & W4300 Electric Pump

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

SECTION AXIAL HVAC FANS

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

MC2500. Installation and Operation Manual

Climas y Proyectos Leyco, S.A. de C.V.

NECO Pumping Systems

Muffin Monster Grinder Model 30004T Motor Controller Model PC2220

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Transcription:

MODEL 10LH SPECIFICATION 1.0 General Specifications There will be furnished one (1) only Grind Hog TM Model 10LH Comminutor as manufactured by G.E.T. Industries, Inc. Rotation shall be in a clockwise (standard) / counter-clockwise (optional) direction. 1.1 Design Criteria The comminutor shall be designed to handle the flows indicated below, within the head loss noted. (a) hydraulic capacity 1.2 MGD (4500m 3 /day) (b) satisfactory operation shall occur under conditions of zero flow (c) head loss at peak flow shall not exceed 10 inches (254 mm) (d) design shall be such that the flow enters the size reduction and screening device horizontally and exits vertically downward to facilitate the flushing of solids 1.2 Casing and Curb Ring Shall be: (a) of heavy-duty construction and of high quality cast iron (b) machined flat and complete with three (3) holes for anchor bolts (c) of the open type allowing free access for complete cutting bar and shear bar mechanism maintenance and inspection without dismantling the unit 1.3 Rotating Drum Screen (a) heavy-duty Cast Ductile Iron ASTM 536, grade 60-45-18 1.4 Cutting Elements (a) replaceable shear bars constructed of high-quality A2 tool-steel shall be attached to the rotating drum. Each shear bar shall be machined from solid bar stock, surface ground to establish exact tolerances (b) stationary cutting bars (3), shall be of high-quality 01 tool steel hardened to a minimum of 56 Rockwell C, and shall be reversible, allowing for four (4) sets of cutting edges prior to sharpening or replacement (c) all submerged fasteners shall be of stainless steel 1.5 Hydraulic Motor The Grind Hog TM motor shall be a low speed, high torque, rotary power hydraulic motor that utilizes the hydraulic pressure developed by the hydraulic power unit to provide rotational torque for unit operation. Motor shall be water tight and functional when submerged up to 20 feet. Hydraulic motor shall be by Sauer Dan Foss or equal 1 5008

SPECIFICATION cont d 1.6 Hydraulic Power Unit a) General 1. The remotely located hydraulic power unit provides hydraulic oil power to drive the hydraulic motor which, through an SM-Cyclo Reducer, drives the rotating drum. In addition, the hydraulic power unit provides overload protection and quick response to frequent stop-start and severe reversing of the unit 2. The entire hydraulic system shall be designed to motor rated 2500-psi maximum pressure. At idle load conditions, the system operating pressure should be in the 200 to 400-psi range 3. As solids are encountered, oil pressure will automatically increase on a demand basis to provide the required hydraulic motor torque necessary to continue rotation of the drum screen 4. Should the system demand pressure exceed 1250-psi, a pressure switch shall be activated and a 4- way (2-directional) solenoid valve shifted. The rotation of the drum screen shall then reverse for about 5 seconds. At the end of this time, the valve shall again be shifted and the drum screen will return to the forward direction 5. If the obstruction has been cleared, the power pack unit shall continue to operate in the forward direction. If the obstruction has not cleared, the reversing sequence shall repeat until the torque requirement is reduced or until it has had to repeat the reversing cycle 7 times within a period of 45 seconds. If 7 reversals have occurred within 45 seconds the controller shall shut down the hydraulic unit, activate an overload relay, and illuminate the indicating light 6. If 5 occur, contact Q8 for a possible auto-dialer is activated b) Components 1. Hydraulic power unit shall include the following components at a minimum a. MA 18 gallon, 24 1/2 x18 1/2 x14 Die Cast Aluminum Reservoir b. Positive displacement pump driven by a TEFC, C face, vertically mounted 5 Hp motor (460/3/60) c. Combination oil level and oil temperature gauge d. 10-micron, oil return line filter e. Oil temperature limit switch set at 176 o F f. Oil level switch g. Filter breather h. Pressure switch (adjustable) preset at 1250-psi i. 110 volt solenoid valve j. Relief valve preset at 1500-psi k. 2-1/2 inch, 0 to 3000-psi oil filled gauge l. Suction strainer m. Flexible hoses rated for a minimum 2000-psi working pressure with quick disconnect at hydraulic motor end and at power pack end

SPECIFICATION cont d 2. The hydraulic power unit will be mounted in a remote location as specified by the owner 3. Hydraulic connections between the Grind Hog TM motor and the hydraulic power unit shall consist of two lengths of 1/2 inch flexible hose sections with quick disconnect couplers. Quick connections shall contain spring loaded ball check valves to avoid oil loss upon disconnecting 4. On completion of installation, the hydraulic power unit must be filled with a high quality fluid (supplied by others) with a viscosity of approximately 100 to 250-SSU at 100 o F (38 o C) with good chemical stability and anti-foaming properties. The grades of hydraulic fluid must be in accordance with the supplier s recommendations CONTROL SYSTEM a) Functional Description 1. The controller shall be the supplier s standard Model GHC 1850H with four (4) button remote control station (on, off, jog forward, jog reverse) and lights in NEMA 4X enclosure 2. The controller shall be equipped with a HAND-OFF/RESET-AUTO three-position selector switch. In OFF/RESET the unit shall not run. In HAND the grinder shall run. In AUTO the unit start and stop will be controlled by a remotely located dry contact 3. When a jam condition occurs in either the HAND or AUTO mode the controller shall stop the unit and reverse its rotation to clear the obstruction. If the jam is cleared, the controller shall return the unit to normal operation. If the jam condition still exists, the controller shall go through seven additional reversing cycles within 45 seconds before signaling an overload condition. When an overload condition occurs the controller shall shut the unit off and activate a fail relay with contacts 4. If operation is terminated due to a fail condition and a power failure occur, the fail indicator shall reactivate when power is restored 5. Controller reset shall be from local panel controls only 6. The controller shall provide over-current protection for the hydraulic power unit oil pump motor through an overload relay mounted directly on the motor starter 7. The controller shall have indicator lights for POWER ON, RUN, GRIND HOG TM OVERLOAD, MOTOR OVERLOAD, OIL OVERTEMP and LOW OIL LEVEL conditions 8. The controller shall be rated 5 Hp, volts, phase, Hz

SPECIFICATION cont d b) Motor Controller Components 1. Enclosure: a. Enclosure shall be fabricated of fiberglass reinforced polyester resins and shall be suitable for wall mounting. Doors shall have corrosion resistant hinges and latches b. Each enclosure shall be NEMA 4X rated and house the overall disconnect switch, control power transformers, control devices, relays, fuses, terminal blocks and full voltage non-reversing motor starter 2. Control Devices: a. Pilot devices shall be mounted on the enclosure front panel b. Indicators shall be integral transformer type with low voltage long life 24 volt lamps. Lamps and selector switches shall be heavy duty NEMA 4X type c. Two sets of normally open (no) dry contact shall be included, one for a FAIL signal output and one for a RUN signal output. The contacts shall be rated 10 amp, 240 VAC, resistive overload 3. Motor Starter: a. A full voltage non-reversing contactor type motor starter shall be provided for the 5 Hp hydraulic oil pump electric motor b. The overload (OL) relay shall be adjustable so that the range selected includes the FLA (Fill load amps) rating and service factor 1.7 Drive Arrangement a) the hydraulic motor shall be close-coupled to a speed reducer drive, a heavy duty planetary gear of the totally enclosed non-vented type suitable for total submergence during emergencies b) double seals on the output shaft shall ensure flood-proof operation through a reduction ratio of 6:1 c) the cycloidal reducer shall be capable of withstanding shock loads to 500% of its mechanical rating of 7.8 Hp. and be warranted for two (2) years d) the drive shall have a minimum full load efficiency of 90% and be pre-lubricated with grease, requiring routing maintenance every 500 to 1,000 hours A) KWIK-LIFT WET WELL REMOVAL SYSTEM The Comminutor shall be equipped with a slide rail system which will allow the Grind Hog TM to be removed without entering the wet well. The guide rails shall be 304 schedule 40 stainless steel pipe, 1.5 inches in diameter, and shall be of adequate length as shown on the drawings. Guide rail support shall be 304 stainless steel and shall be mounted to the wet well wall. All attaching hardware shall be of stainless steel and shall be supplied by the contractor.

HYDRAULIC DATA SHEET IN-CHANNEL MODEL 10L GENERAL DATA Capacity Drum Diam. 9.4 in 23.9 cm 2 2 Inlet Area 97 in 625.8 cm 2 2 Outlet Area 45 in 290.3 cm Slot Width 0.470 in 12 mm 3 0-1.2 MGD (US) 0-4500 m /day HYDRAULIC PERFORMANCE CURVE Liquid Level Differential Dh = h 1 - h 2 Inches 3 Flow Rate Q - Cubic Meters per Day x 10.4.8 1.6 2.4 3.2 4.0 6 8 12 16 50 40 30 20 15 10 8 6 4 2 h 1= level in intake h 2 = level in outlet Drum submerged. Contnuous operation above this line is not recommended in systems where surface debris present. Dh = head loss across drum (h1-h 2) h 2 = 0 for free discharge h 2=0 1 2 4 6 8 9 MODEL 10L 125 100 75 50 25 20 15 10 5 Liquid Level Differential Dh = h 1 - h 2 Centimeters.1.2.4.6.8 1.0 2 4 5 Flow Rate Q - Million U.S. Gallons Per Day G.E.T. Industries Inc. Toll Free: (877) 213-7418 E-mail: get@grindhog.com 6 Web: www.grindhog.com

IN-CHANNEL MODEL 10L cont d... DESIGN FEATURES G.E.T. Industries Inc. Toll Free: (877) 213-7418 E-mail: get@grindhog.com 6 Web: www.grindhog.com

MECHANICAL DETAIL