Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Similar documents
Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

Resistance thermometer For sanitary applications Model TR22-B, for orbital welding

Thermowell For sanitary applications Model TW22

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Resistance thermometer Without thermowell Model TR10-H

Thermowell For sanitary applications Model TW61, for orbital welding

Thermowell For sanitary applications Model TW61, for orbital welding

Thermocouple For additional thermowell Model TC10-B

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Thermocouple Without thermowell Model TC10-H

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Thermowell For sanitary applications Model TW61, for orbital welding

Measuring insert for process resistance thermometer

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Thermowell For sanitary applications Model TW61, for orbital welding

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple with spring-loaded tip Model TC55

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Cable resistance thermometer Model TR40

Measuring insert for resistance thermometer Model TR10-A

Surface thermocouple Model TC50

Resistance thermometer Model TR10-B, for additional thermowell

Thermocouple Model TC10-H without thermowell

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Resistance thermometer Model TR10-E, for additional thermowell

Cable thermocouple Model TC40

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-W

Thermocouples Model TC10-B, for Additional Thermowell

Cable resistance thermometer Model TR40

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Tubeskin thermocouple assembly Model TC59-V

Resistance thermometer with digital display Model TR75, battery operation

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

NEUMO BioControl Model

Cable resistance thermometer Model TR40

Reed sensor For bypass level indicators Model BLR

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

SITRANS T measuring instruments for temperature

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

High-pressure thermocouple Model TC90

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Diaphragm seal with sterile connection For homogeniser machines Model

Cable thermocouple Model TC40

Duct thermometer Model TF40

Pressure Transmitters for Sanitary Applications Model SA-11

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Resistance thermometer with digital indicator Model TR75, battery operation

Thermocouple Model TC10-E, for additional thermowell

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Thermocouples Model TC10-E, for Additional Thermowell

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

SITRANS P measuring instruments for pressure

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Mini pressure switch Stainless steel switch enclosure Model PXS

Temperature multi-function calibrator Model CTM

Compact temperature switch Model TCS

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Mini temperature switch Stainless steel switch enclosure Model TXS

Insertion thermometer With connection lead Model TF45

Compact pressure switch Model PCS

Accessories for diaphragm seals Block flange and saddle flange Models , ,

Bimetal thermometer Model 52, industrial series

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Mechatronic pressure measurement. Applications. Special features. Description

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Differential pressure gauge with electrical output signal Model A2G-15

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Gas-actuated thermometer Highly vibration resistant Model 75, stainless steel version

Bimetal thermometer Model 52, industrial series

Compact differential pressure switch Models DC, DCC

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Pressure transmitter COMPACT ECOnomic

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Hot runner thermocouple Model TC46

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Pressure transmitter UNIVERSAL CA

Diaphragm seal with threaded connection Plastic version Model

Transcription:

Temperature Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A WIKA data sheet TE 60.22 for further approvals see page 15 Applications Sanitary applications Food and beverage industry Bio and pharmaceutical industry, production of active ingients Special features Simplified calibration through removable measuring inserts Materials and surface finish quality in accordance with the standards of hygienic design Stainless steel head in optimised hygienic design, easily cleanable in all mounting positions (patent, industrial property right registe under no. GM 000984349) Pt100, 4 20 ma or HART protocol, FOUNDATION Fieldbus and PROFIBUS PA output possible Model TR22-A with VARIVENT connection Options: Sealing combination at neck tube, cable gland in hygienic design Description The model TR22-A resistance thermometer is used for temperature measurement in sanitary applications. The process connections meet the stringent requirements, in terms of materials and design, of hygienic measuring points. With increased hygienic requirements for the ambient areas around the measuring point, a stainless steel head is available in an optimised hygienic design. This enables easy cleaning of the measuring instrument, particularly for splash zones in food production. Due to the rotatable screw connection to the connection head, it is possible to loosen the connection head and to adjust it in the desi position. The connection head can be removed together with the measuring insert. This allows the resistance thermometer to be calibrated along with the whole measuring chain, i.e. without disconnecting the electrical connections. In addition, this avoids having to open the process, and thus the risk of contamination is minimised. The spring-loaded measuring insert guarantees the contact between the sensor tip and the bottom of the thermowell and thus ensures a fast response time and high accuracy. The welded junction between the thermowell and the flange makes the use of a sealing as additional material in those areas undant which are in contact with the product. Page 1 of 17 Data sheets showing similar products: Miniature resistance thermometer, with flange connection; model TR21-A; see data sheet TE 60.26 Miniature resistance thermometer, for orbital welding; model TR21-B; see data sheet TE 60.27 Miniature resistance thermometer, with welded flange connection; model TR21-C; see data sheet TE 60.28 Resistance thermometer, for orbital welding; model TR22-B; see data sheet TE 60.23

Specifications Output signal Pt100 Temperature range Sensor Measuring range -50... +250 C (-58... +482 F) Measuring element (measuring current: 0.1... 1.0 ma) Pt100 (thin-film) Face-sensitive Pt100 (thin-film) 1) Connection method 1 x 3-wire 1 x 4-wire 2 x 3-wire Tolerance value/range of use of the measuring element 2) per IEC 60751 (class accuracy) Response time (measurement per IEC 60751) Measuring insert diameter Class AA 0... 150 C Class A -30... +250 C Class B -50... +250 C t 50 < 4.7 s t 90 < 12.15 s 3 mm For detailed specifications for Pt100 sensors, see Technical information IN 00.17 at www.wika.com. Output signal 4... 20 ma, HART protocol, FOUNDATION Fieldbus and PROFIBUS PA Transmitter (selectable versions) Model T15 Model T32 Model T53 Output 4... 20 ma x x HART protocol x FOUNDATION Fieldbus and PROFIBUS PA x Connection method 1 x 3-wire or 1 x 4-wire x x x Measuring current < 0.2 ma < 0.3 ma < 0.2 ma Temperature range Response time (measurement per IEC 60751) Configuration Measuring range -50... +250 C (-58... +482 F) 3), other measuring ranges are adjustable t 50 < 4.7 s or t 90 < 12.15 s + response time of the respective transmitter (see the data sheet for the respective transmitter) Basic configuration: Pt100, 3-wire, 0... 150 C (32... 302 F) customer-specific configuration available on request 1) Through their small design, face-sensitive measuring resistors serve to uce the heat dissipation with short insertion lengths. Available for temperature ranges up to 150 C (302 F). For thermowell insertion lengths of less than 50 mm, face-sensitive measuring resistors are recommended. For thermowell insertion lengths of less than 11 mm, face-sensitive measuring resistors are generally used. 2) Specification is only valid for the measuring element. Depending on the process connection, the deviation can be greater. 3) The connection head should therefore be protected from temperatures over 80 C (176 F). Page 2 of 17

Thermowell model TW22 Process connections Tri-clamp and clamp per DIN 32676, ISO 2852 VARIVENT BioControl Union nut DIN 11851 Aseptic connections per DIN 11864 Union nut SMS Process connection, straight Welding ball Ball-/Collar-type compression fitting other process connections on request Thermowell diameter 6 mm Option: thermowell tip stepped down to 4.5 mm (from U 1 > 25 mm) 0.25 inch Option: thermowell tip stepped down to 0.2 inch (from U 1 > 1 inch) Materials (wetted) Stainless steel 1.4435 (316L, UNS S31603) Surface roughness Insertion length U 1 4) Neck tube diameter Neck tube length M Connection to thermometer M24 x 1.5 Standard: R a 0.76 µm (SF3 per ASME BPE) Option: R a 0.38 μm (SF4 per ASME BPE) R a 0.38 µm electropolished (SF4 per ASME BPE) Standard: 25, 50, 75, 100, 150, 200 mm or 1, 2, 3, 4, 6, 8 inch other insertion lengths are available as options up to DN 20: 9 mm (0.35 inch); except per DIN 11851, milk thread fitting: 12 mm from DN 25: 12 mm (0.5 inch) 85 mm (3.35 inch), others on request 4) For the TR22-A design without thermowell, the insertion length is defined by the dimension l 1 from the lower edge of the connection head to the tip of the measuring insert (see Dimensions of the connection heads in mm ). The thickness of bottom of the thermowell can be neglected for dimensioning. It is offset by the spring travel of the measuring insert. Sealing combination (option) The transition from the connection head to the thermowell is effected via an optional sealing combination (polyurethane) of flat gasket and wiper. This combination permanently prevents the penetration and depositing of humidity and impurities in this area (IP68). Additionally, the sealing combination simplifies the cleaning process significantly. In combination with the patented BVS head and the cable gland in hygienic design, it delivers an easy-to-clean and hygienic measuring point, even in those areas not in contact with the product. The BVS head is designed in such a way that cleaning agents can run off easily and that no residues can accumulate on the case. Page 3 of 17

Connection head BVC BVS BS BSZ BSZ-K BSZ-H BSZ-HK KN4-P KN4-A Model Material Cable entry thread size Ingress protection Cap Surface BVC Stainless steel (1.4571) M16 x 1.5 1) IP68 Flat screw-on lid Natural finish BVS Stainless steel (1.4308) M20 x 1.5 1) IP65 Screw-on lid, hygienic design Precision casting, electropolished BS Aluminium M20 x 1.5 1) IP65 (IP68) Cap with 2 screws Blue, lacque 2) BSZ Aluminium M20 x 1.5 1) IP65 (IP68) Hinged cover with cylinder head screw Blue, lacque 2) BSZ-K PAV antistatic PA12 M20 x 1.5 1) IP65 Hinged cover with cylinder head screw Black BSZ-H Aluminium M20 x 1.5 1) IP65 (IP68) Hinged cover with cylinder head screw Blue, lacque 2) BSZ-HK PAV antistatic PA12 M20 x 1.5 1) IP65 Hinged cover with cylinder head screw Black KN4-P Polypropylene M20 x 1.5 IP65 Screw-on lid White KN4-A Aluminium M20 x 1.5 IP65 Screw-on lid Blue, lacque 2) 1) Standard 2) RAL 5022 Cable entry with M12 x 1 coupler connector / 4-pin (option) Instead of a standard cable gland, the cable entry of a connection head can optionally be designed with a M12 x 1 (4-pin) coupler connector. The maximum resulting ingress protection is IP65. Connecting with single strands for operation is not needed as pre-assembled cables can be used. Connection head with digital indicator (option) As an alternative to the standard connection head, the thermometer can be fitted with an optional DIH10 digital indicator. The connection head used for this is similar to the model BSZ-H head. For operation, a 4... 20 ma transmitter is needed, which is mounted to the measuring insert. The indication range is configu identically to the measuring range of the transmitter. Connection head with M12 x 1 coupler connector (4-pin) Connection head with digital indicator, model DIH10 Page 4 of 17

Transmitter (option) Depending on the connection head used, a transmitter can be mounted within the thermometer. Mounted instead of terminal block Mounted within the cap of the connection head Mounting not possible Mounting of 2 transmitters on request. Connection head Transmitter model T15 T32 T53 BVC BVS BS - - BSZ / BSZ-K BSZ-H / BSZ-HK KN4-P / KN4-A Model Description Explosion protection Data sheet T15 Digital transmitter, PC configurable Optional TE 15.01 T32 Digital transmitter, HART protocol Optional TE 32.04 T53 Digital transmitter, FOUNDATION Fieldbus und PROFIBUS PA Standard TE 53.01 Page 5 of 17

Overview of combinations Clamp VARIVENT BioControl DIN 11851/DIN 11864 1) Union nut SMS Process connection, straight Welding ball Ball-/Collar-type compression fitting 1) Process connections per DIN 11864-2 and DIN 11864-3, see Dimensions of the process connections in mm VARIVENT is a registe trademark of the company GEA Tuchenhagen. BioControl is a registe trademark of the company NEUMO. Page 6 of 17

Dimensions in mm 1) 1) 14006093.04 1) In the event of replacement, select a resistance thermometer measuring insert model TR11-A. (see data sheet TE 60.13) The corresponding sensor length, l 5, is calculated as follows: Insertion length U 1 + neck tube length M (85 mm) + 10 mm Dimensions of the connection heads in mm Model BVC Model BVS Model BS 1606042.02 Models BSZ, BSZ-K Models BSZ-H, BSZ-HK Models KN4-P, KN4-A 1606727.02 3185720.02 14117032.01 14117029.01 14025833.02 Page 7 of 17

Dimensions of the process connections in mm (thermowells model TW22) Clamp process connection VARIVENT process connection 1) 11428644.04 11428601.04 U 1 = variable insertion length U 1 = variable insertion length 1) In combination with T-ring seals from Combifit International B. V., Netherlands Dimensions for clamp process connection Process connection Nominal width in mm/inch PN in bar Dimensions in mm Weight in kg DIN 32676 for pipes per DIN 11866 row A DN 10... 20 25 34.0 0.2 Ø D DN 25... 40 25 50.5 0.3 DN 50 16 64.0 0.4 DIN 32676 for pipes per DIN 11866 row B 13.5... 17.2 25 25.0 0.2 21.3... 33.7 25 50.5 0.3 42.4... 48.3 16 64.0 0.3 DIN 32676 for pipes per DIN 11866 row C ½"... ¾" 25 25.0 0.2 1"... 1 ½" 25 50.5 0.3 2" 16 64.0 0.4 Tri-clamp per ASME BPE ½" 13.8 25.0 0.2 ¾" 13.8 25.0 0.2 1" 13.8 50.5 0.3 1 ½" 13.8 50.5 0.3 2" 13.8 64.0 0.4 2 ½" 13.8 77.5 0.4 3" 13.8 91.0 0.5 4" 13.8 119.0 0.5 ISO 2852 DN 12... 21.3 16 34.0 0.2 DN 25... 38 16 50.5 0.3 DN 40... 51 16 64.0 0.4 Dimensions for VARIVENT process connection Process connection Nominal width in mm PN in bar Dimensions in mm Weight in kg Ø D Ø d H h Form B DN 10, DN 15 25 31 52.7 20 13.65 0.3 Form F DN 25, DN 32 25 50 66.0 18 12.30 0.4 Form N DN 40, DN 50 25 68 84.0 18 12.30 0.6 Page 8 of 17

NEUMO BioControl process connection Union nut process connection DIN 11851 with conical coupling (milk thread fitting) 11433485.04 2) 11428784.04 U 1 = variable insertion length For fitting into a flow-through housing, the insertion length U 1 and the thermowell diameter must be matched. For angular housings, the insertion length U 1 must be specified by the customer. The cases are not part of the scope of delivery of the resistance thermometers and can be orde as a separate item. For a detailed description of the BioControl cases, see data sheet AC 09.14. U 1 = variable insertion length 2) In combination with - ASEPTO-STAR k-flex upgrade gaskets from Kieselmann GmbH, Germany or - SKS gasket set DIN 11851 EHEDG from Siersema Komponenten Dimensions for NEUMO BioControl process connection Case size Nominal width of pipe PN in bar Dimensions in mm Weight in kg U 1 3) Ø d 4 Ø D f b Ø k Ø d 2 Size 25 DN 8 16 5 30.5 64 11 20 50 4 x Ø 7 0.4 DN 10 16 6 30.5 64 11 20 50 4 x Ø 7 0.4 DN 15 16 9 30.5 64 11 20 50 4 x Ø 7 0.4 DN 20 16 11 30.5 64 11 20 50 4 x Ø 7 0.4 Size 50 DN 25 16 15 50.0 90 17 27 70 4 x Ø 9 0.8 DN 40 16 20 50.0 90 17 27 70 4 x Ø 9 0.8 DN 50 16 25 50.0 90 17 27 70 4 x Ø 9 0.8 DN 65 16 35 50.0 90 17 27 70 4 x Ø 9 0.8 DN 80 16 45 50.0 90 17 27 70 4 x Ø 9 0.8 DN 100 16 55 50.0 90 17 27 70 4 x Ø 9 0.8 Size 65 DN 40 16 20 68.0 120 17 27 95 4 x Ø 11 1.4 Nominal width in mm DN 50 16 25 68.0 120 17 27 95 4 x Ø 11 1.4 DN 65 16 35 68.0 120 17 27 95 4 x Ø 11 1.4 DN 80 16 45 68.0 120 17 27 95 4 x Ø 11 1.4 DN 100 16 55 68.0 120 17 27 95 4 x Ø 11 1.4 Dimensions for union nut process connection DIN 11851 with conical coupling (milk thread fitting) PN in bar Dimensions in mm Weight in kg Ø d 6 G Ø D g DN 20 40 36.5 RD 44 x 1/6 54 8 0.4 DN 25 40 44.0 RD 52 x 1/6 63 10 0.5 DN 32 40 50.0 RD 58 x 1/6 70 10 0.6 DN 40 40 56.0 RD 65 x 1/6 78 10 0.8 DN 50 25 68.5 RD 78 x 1/6 92 11 0.9 3) Recommended insertion length for installation in BioControl flow-through housing; other insertion lengths are possible Page 9 of 17

Process connection, aseptic threaded pipe connection DIN 11864-1 with form A liner, for pipes in accordance with DIN 11866 row A, B and C 11428814.06 U 1 = variable insertion length Nominal width of pipe Nominal pressure in bar Outer diameter of pipe Pipe schedule Inner diameter of pipe Process connection DN / OD PN s Ø D G h k DIN 11866 row A or metric Aseptic O-ring 10 40 13 1.5 10 38 RD 28 x 1/8 9 18 12 x 3.5 0.2 15 40 19 1.5 16 44 RD 34 x 1/8 9 18 18 x 3.5 0.2 20 40 23 1.5 20 54 RD 44 x 1/6 10 20 22 x 3.5 0.25 25 40 29 1.5 26 63 RD 52 x 1/6 12 21 28 x 3.5 0.4 32 40 35 1.5 32 70 RD 58 x 1/6 13 21 34 x 5 0.45 40 40 41 1.5 38 78 RD 65 x 1/6 13 21 40 x 5 0.55 50 25 53 1.5 50 92 RD 78 x 1/6 14 22 52 x 5 0.7 DIN 11866 row B or ISO 8 (13.5) 40 13.5 1.6 10.3 38 RD 28 x 1/8 9 18 12 x 3.5 0.2 10 (17.2) 40 17.2 1.6 14 44 RD 34 x 1/8 9 18 16 x 3.5 0.2 15 (21.3) 40 21.3 1.6 18.1 54 RD 44 x 1/6 10 20 20 x 3.5 0.3 20 (26.9) 40 26.9 1.6 23.7 63 RD 52 x 1/6 12 21 26 x 3.5 0.4 25 (33.7) 40 33.7 2 29.7 70 RD 58 x 1/6 13 21 32 x 5 0.5 32 (42.4) 25 42.4 2 38.4 78 RD 65 x 1/6 13 21 40.5 x 5 0.6 40 (48.3) 25 48.3 2 44.3 92 RD 78 x 1/6 14 22 46.6 x 5 0.7 DIN 11866 row C or ASME BPE 1/2" 40 12.7 1.65 9.4 38 RD 28 x 1/8 9 18 12 x 3.5 0.2 3/4" 40 19.05 1.65 15.75 44 RD 34 x 1/8 9 18 18 x 3.5 0.2 1" 40 25.4 1.65 22.1 63 RD 52 x 1/6 12 21 24 x 3.5 0.4 1 1/2" 40 38.1 1.65 34.8 78 RD 65 x 1/6 13 21 37 x 5 0.6 2" 25 50.8 1.65 47.5 92 RD 78 x 1/6 14 22 50 x 5 0.7 Weight in kg Page 10 of 17

Aseptic flange process connection DIN 11864-2, form A for pipes in accordance with DIN 11866 row A Flange with notch Aseptic flange with notch, DIN 11864-2 form A Flange with groove Aseptic flange with groove DIN 11864-2 form A 11429683.05 U 1 = variable insertion length Process connection Flange with notch Flange with groove Nominal width in mm PN in bar Dimensions in mm b 1 b 2 Ø d 5 Ø d 6 Ø d 10 Ø d 11 Ø d 13 Aseptic O-ring DN 10 25-10 37-54 22.4 4 x Ø 9 12 x 3.5 0.2 DN 15 25-10 42-59 28.4 4 x Ø 9 18 x 3.5 0.25 DN 20 25-10 47-64 32.4 4 x Ø 9 22 x 3.5 0.3 DN 25 25-10 53-70 38.4 4 x Ø 9 28 x 3.5 0.1 DN 32 25-10 59-76 47.7 4 x Ø 9 34 x 5 0.4 DN 40 25-10 65-82 53.7 4 x Ø 9 40 x 5 0.5 DN 50 16-10 77-94 65.7 4 x Ø 9 52 x 5 0.6 DN 10 25 11.5-37 22.3 54-4 x Ø 9 12 x 3.5 0.25 DN 15 25 11.5-42 28.3 59-4 x Ø 9 18 x 3.5 0.3 DN 20 25 11.5-47 32.3 64-4 x Ø 9 22 x 3.5 0.3 DN 25 25 11.5-53 38.3 70-4 x Ø 9 28 x 3.5 0.4 DN 32 25 11.5-59 47.6 76-4 x Ø 9 34 x 5 0.45 DN 40 25 11.5-65 56.6 82-4 x Ø 9 40 x 5 0.6 DN 50 16 11.5-77 65.6 94-4 x Ø 9 52 x 5 0.7 Weight in kg Connections for pipes in accordance with DIN 11866 row B (ISO pipes) and row C (ASME pipes) available on request. Page 11 of 17

Aseptic clamp process connection, DIN 11864-3, form A for pipes in accordance with DIN 11866 row A Clamp with notch Aseptic clamp with notch DIN 11864-2 form A Clamp with groove Aseptic clamp with groove DIN 11864-2 form A 11431318.05 U1 = variable insertion length Process connection Clamp with notch Clamp with groove Nominal width in mm PN in bar Dimensions in mm Weight in kg Ø d 6 Ø d 10 Ø d 11 h Aseptic O-ring DN 10 40-34 22.4 10 12 x 3.5 0.2 DN 15 40-34 28.4 10 18 x 3.5 0.2 DN 20 40-50.5 32.4 10 22 x 3.5 0.3 DN 25 40-50.5 38.4 10 28 x 3.5 0.3 DN 32 40-50.5 47.7 10 34 x 5 0.3 DN 40 40-64 53.7 10 40 x 5 0.4 DN 50 25-77.5 65.7 10 52 x 5 0.5 DN 10 40 22.3 34-11.5 12 x 3.5 0.2 DN 15 40 28.3 34-11.5 18 x 3.5 0.2 DN 20 40 32.3 50.5-11.5 22 x 3.5 0.3 DN 25 40 38.3 50.5-11.5 28 x 3.5 0.3 DN 32 40 47.6 50.5-11.5 34 x 5 0.3 DN 40 40 53.6 64-11.5 40 x 5 0.4 DN 50 25 65.6 77.5-11.5 52 x 5 0.5 Connections for pipes in accordance with DIN 11866 row B (ISO pipes) and row C (ASME pipes) available on request. Page 12 of 17

Union nut process connection SMS U 1 = variable insertion length Nominal width in inch PN in bar Dimensions in mm Weight in kg Ø D Ø d 2 B l 2 G 1" 40 51 35.5 25 3.5 RD 40 x 1/6 0.4 1 ½" 40 74 55 25 4 RD 60 x 1/6 0.8 2" 40 84 65 26 4 RD 70 x 1/6 1.0 Process connection, straight, Ø 6 mm, basic shape for compression fitting Welding ball process connection 4) Weld-in area 11431067.02 11429224.02 11430303.05 Weight: approx. 0.3 kg Weight: approx. 0.3 kg 4) In order to meet the 3-A standard, the weld seam must be finished with a minimum radius of 3.2 mm on the product side. In this way, no weld defects, such as recesses or gaps, remain. Page 13 of 17

Compression fitting process connection Ball-type compression fitting Collar-type compression fitting Weld-in area 11428954.06 11429208.05 Weight: approx. 0.3 kg Weight: approx. 0.3 kg Other process connections and nominal widths available on request. Electrical connection 1 x Pt100, 3-wire 1 x Pt100, 4-wire 2 x Pt100, 3-wire white white 3160629.06 white white yellow black white white white white black black yellow For the electrical connections of built-in temperature transmitters see the corresponding data sheets or operating instructions. Page 14 of 17

Explosion protection (option) Resistance thermometers of the TR22-A series are available with an EC-type examination certificate for intrinsically safe, Ex i, ignition protection. These instruments comply with the requirements of the ATEX directive for gas and dust. The permissible power, P max, as well as the permissible ambient temperature, for the respective category can be seen on the EC-type examination certificate and the certificate for hazardours areas or the operating instructions. Built-in transmitters have their own EC-type examination certificate. The permissible ambient temperature ranges of the built-in transmitters can be taken from the corresponding transmitter approval. The system operator is responsible for using suitable thermowells. Approvals Logo Description Country EU declaration of conformity EMC directive 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application) RoHS directive ATEX directive (option) Hazardous areas Zone 0 gas Zone 1 mounting to zone 0 gas Zone 1 gas Zone 20 dust Zone 21 mounting to zone 20 dust Zone 21 dust [II 1G Ex ia IIC T1... T6 Ga] [II 1/2G Ex ia IIC T1... T6 Ga/Gb] [II 2G Ex ia IIC T1... T6 Gb] [II 1D Ex ia IIIC T125... T65 C Da] [II 1/2D Ex ia IIIC T125... T65 C Da/Db] [II 2D Ex ia IIIC T125... T65 C Db] IECEx (option) - in conjunction with ATEX Hazardous areas Zone 0 gas [Ex ia IIC T1... T6 Ga] Zone 1 mounting to zone 0 gas [Ex ia IIC T1... T6 Ga/Gb] Zone 1 gas [Ex ia IIC T1... T6 Gb] Zone 20 dust [Ex ia IIIC T125... T65 C Da] Zone 21 mounting to zone 20 dust [Ex ia IIIC T125... T65 C Da/Db] Zone 21 dust [Ex ia IIIC T125... T65 C Db] EAC (option) EMC directive 1) Hazardous areas Zone 0 gas Zone 1 gas Zone 20 dust Zone 21 dust [0 Ex ia IIC T3/T4/T5/T6] [1 Ex ib IIC T3/T4/T5/T6] [DIP A20 Ta 65 C/Ta 95 C/Ta 125 C] [DIP A21 Ta 65 C/Ta 95 C/Ta 125 C] INMETRO (option) Metrology, measurement technology Hazardous areas Zone 0 gas [Ex ia IIC T3... T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3... T6 Ga/Gb] Zone 1 gas [Ex ib IIC T3... T6 Gb] Zone 20 dust [Ex ia IIIC T125... T65 C Da] Zone 21 mounting to zone 20 dust [Ex ib IIIC T125... T65 C Da/Db] Zone 21 dust [Ex ib IIIC T125... T65 C Db] European Union International Eurasian Economic Community Brazil Page 15 of 17

Logo Description Country KCs - KOSHA (option) Hazardous areas Zone 0 Gas [Ex ia IIC T4... T6] Zone 1 Gas [Ex ib IIC T4... T6] - PESO (option) Hazardous areas Zone 0 gas Zone 1 mounting to zone 0 gas Zone 1 gas GOST (option) Metrology, measurement technology KazInMetr (option) Metrology, measurement technology - MTSCHS (option) Permission for commissioning Uzstandard (option) Metrology, measurement technology 3-A (option) 2) Sanitary Standard EHEDG (option) 2) Hygienic Equipment Design [Ex ia IIC T1... T6 Ga] [Ex ib IIC T3... T6 Ga/Gb] [Ex ib IIC T3... T6 Gb] South Korea India Russia Kazakhstan Kazakhstan Uzbekistan USA European Community 1) Only for built-in transmitter 2) Confirmation of 3-A or EHEDG conformity only valid with separately selectable 2.2 test report Instruments marked with ia may also be used in areas only requiring instruments marked with ib or ic. If an instrument with ia marking has been used in an area with requirements in accordance with ib or ic, it can no longer be operated in areas with requirements in accordance with ia afterwards. Certificates (option) 2.2 test report 3.1 inspection certificate DKD/DAkkS calibration certificate Manufacturer's declaration regarding Regulation (EC) 1935/2004 Certificate of the surface roughness of wetted parts Hygienic design conformity Process connection 3-A EHEDG Clamp yes yes 4) VARIVENT yes yes BioControl yes no DIN 11851 yes 3) yes 4) DIN 11864 yes yes Welding ball yes no Compression fitting no no SMS no no 3) In combination with - ASEPTO-STAR k-flex upgrade gaskets from Kieselmann GmbH, Germany or - SKS gasket set DIN 11851 EHEDG from Siersema Komponenten 4) In combination with T-ring seals from Combifit International B. V., Netherlands Approvals and certificates, see website Page 16 of 17

Patents, property rights Case with easily cleanable twist crown, integrated into the case cap (GM 000984349) Ordering information Model / Explosion protection / Sensor / Accuracy class / Connection head / Cable gland / Transmitter / Thermowell / Process connection / Thermowell diameter / Wetted-parts materials / Insertion length U 1 / Neck tube length / Certificates / Optional further sealing combinations 02/2011 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 08/2018 EN Page 17 of 17 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de