Improvement the Possibilities of Capacitive Energy Storage in Metro Railcar by Simulation

Similar documents
Energy Management and Hybrid Energy Storage in Metro Railcar

ESS SIZING CONSIDERATIONS ACCORDING TO CONTROL STARTEGY

A study of the power capacity of regenerative inverters in a DC electric railway system

Sizing of Ultracapacitors and Batteries for a High Performance Electric Vehicle

Development of Motor-Assisted Hybrid Traction System

Wayside Energy Storage System Modeling

Energy Management for Regenerative Brakes on a DC Feeding System

Battery-Ultracapacitor based Hybrid Energy System for Standalone power supply and Hybrid Electric Vehicles - Part I: Simulation and Economic Analysis

Hybrid Architectures for Automated Transmission Systems

The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

Train Group Control for Energy-Saving DC-Electric Railway Operation

Examining the braking energy recovery in a vehicle with a hybrid drive system

Regenerative Braking for an Electric Vehicle Using Ultracapacitors and a Buck-Boost Converter

Power Flow Simulation of Flywheel Energy Storage Systems for Tramways

Applications for energy storage flywheels in vehicles of Deutsche Bahn AG

II. ANALYSIS OF DIFFERENT TOPOLOGIES

Dynamic Modeling and Simulation of a Series Motor Driven Battery Electric Vehicle Integrated With an Ultra Capacitor

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11)

Supercapacitor Based Power Conditioning System for Power Quality Improvement in Industries

Dr. Philippe Barrade LEI, Ecole Polytechnique Fédérale de Lausanne, Suisse ** L2EP, University Lille1, France

Circumstances affecting the protection against electrode potential rise (EPR)

Design of High Performance and High Efficiency DC-DC Converter for Hybrid Electric Vehicles

«Modelling and EMR of a Hybrid Elevator»

Technology Development of Dual Power Supply System for Mild Hybrid System and Micro Hybrid System

Application Case. Issued by Solution Center Date May, 2013 Pages 5

THE USE OF DIGITAL HYDRAULIC TO THE POSITION CONTROL OF HYDRAULIC CYLINDER

PERFORMANCE ANALYSIS OF VARIOUS ULTRACAPACITOR AND ITS HYBRID WITH BATTERIES

Special edition paper Development of an NE train

Energy Management Strategy Based on Frequency- Varying Filter for the Battery Supercapacitor Hybrid System of Electric Vehicles

INTELLIGENT URBAN MOBILITY SOLUTIONS MARTIN ERTL CHIEF INNOVATION OFFICER BOMBARDIER TRANSPORTATION BERLIN,

A strategy for utilization of regenerative energy in urban railway system by application of smart train scheduling and wayside energy storage system

Specifications and schedule of a fuel cell test railway vehicle. T. Yoneyama, K. Ogawa, T. Furuya, K. Kondo, T. Yamamoto

Special edition paper

Development of an energy efficient train traffic control system for saving electricity

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

Abstract. Keywords. Pankaj Govind Hiray 1, B. E. Kushare 2

Analysis and Design of the Super Capacitor Monitoring System of Hybrid Electric Vehicles

DSP Based Ultracapacitor System for Hybrid-Electric Vehicles

A DIGITAL CONTROLLING SCHEME OF A THREE PHASE BLDM DRIVE FOR FOUR QUADRANT OPERATION. Sindhu BM* 1

Development of a High Efficiency Induction Motor and the Estimation of Energy Conservation Effect

REGENERATIVE BRAKING FOR AN ELECTRIC VEHICLE USING HYBRID ENERGY STORAGE SYSTEM

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

ZEBRA plus ultracapacitors: A good match for energy efficient EVs

Construction of a Hybrid Electrical Racing Kart as a Student Project

Flywheel energy storage retrofit system

Components for Powertrain Electrification

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Simulation research on rail transit traction grid voltage stabilization and its energy saving effects based on BESS

Performance optimization of a battery capacitor hybrid system

Supercapacitors For Load-Levelling In Hybrid Vehicles

Hybrid Three-Port DC DC Converter for PV-FC Systems

Analysis of a Hybrid Energy Storage System Composed from Battery and Ultra-capacitor

AABC Europe 2017 Mainz, Germany Dr. Jörn Albers, Dr. Christian Rosenkranz Johnson Controls Power Solutions EMEA. Johnson Controls Power Solutions EMEA

Innovative Power Supply System for Regenerative Trains

ENERGY STORAGE SOLUTIONS FOR IMPROVING THE ENERGY EFFICIENCY OF PUBLIC TRANSPORT VEHICLES

Hybrid Drives for Mobile Equipment

Electromagnetic Fully Flexible Valve Actuator

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

Model-Based Investigation of Vehicle Electrical Energy Storage Systems

Modelling and Control of Ultracapacitor based Bidirectional DC-DC converter systems PhD Scholar : Saichand K

Implementation of FC-TCR for Reactive Power Control

Copyright 2016 Surya Powerfarad Energies Limited. P a g e 1

Design & Development of Regenerative Braking System at Rear Axle

The Experimental Study of the Plateau Performance of the F6L913 Diesel Engine

NUMERICAL ANALYSIS OF IMPACT BETWEEN SHUNTING LOCOMOTIVE AND SELECTED ROAD VEHICLE

Study of the Performance of a Driver-vehicle System for Changing the Steering Characteristics of a Vehicle

Application of DSS to Evaluate Performance of Work Equipment of Wheel Loader with Parallel Linkage

K. Shiokawa & R. Takagi Department of Electrical Engineering, Kogakuin University, Japan. Abstract

Future Power Technologies

ENERGY RECOVERY SYSTEM FOR EXCAVATORS WITH MOVABLE COUNTERWEIGHT

Jornada Técnica de la PTFE: GESTIÓN ENERGÉTICA SOSTENIBLE E INTELIGENTE EN EL ÁMBITO FERROVIARIO Madrid, 12 de marzo de Marcos Lafoz Pastor

EMS of Electric Vehicles using LQG Optimal Control

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION

3 - Month Progress Report

Development of ESS for Regenerative Energy of Electric Vehicle

Energy Saving Technologies for Elevators

Study on Braking Energy Recovery of Four Wheel Drive Electric Vehicle Based on Driving Intention Recognition

Effect of plus sizing on driving comfort and safety of users

Low Carbon Technology Project Workstream 8 Vehicle Dynamics and Traction control for Maximum Energy Recovery

Supercapacitors for trolleybuses: an effective technology

Supercapacitor for Hybrid Energy Storage in a Rural Microgrid

Field Tests of DC 1500 V Stationary Energy Storage System

E-Highway2050 WP3 workshop April 15 th, 2014 Brussels. Battery Storage Technology Assessment Lukas Sigrist, Comillas, Eric Peirano, TECHNOFI

Modeling Reversible Self-Discharge in Series- Connected Li-ion Battery Cells

Investigating the impact of track gradients on traction energy efficiency in freight transportation by railway

Integration of Ultra Capacitor with Battery using DC-DC Bidirectional Buck Boost Converter in an Electric Vehicle.

ANALYSIS OF CONTROL SYSTEMS FOR VEHICLE HYBRID POWERTRAINS

IDENTIFICATION OF FUEL INJECTION CONTROL SYSTEM IN A GDI ENGINE

COMPUTER AIDED MODELLING OF HYBRID MINI VAN

STEAM the hydraulic hybrid system for excavators

Methods of reducing power losses in distribution systems

Test Based Optimization and Evaluation of Energy Efficient Driving Behavior for Electric Vehicles

Alternative Energy Storage System for Hybrid Electric Vehicles

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

MULTI-PARAMETER OPTIMIZATION OF BRAKE OF PISTON

The analysis of the PEMS measurements of the exhaust emissions from city buses using different research procedures

Featured Articles Utilization of AI in the Railway Sector Case Study of Energy Efficiency in Railway Operations

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

Efficient Source and Demand Leveling Power System

Transcription:

Improvement the Possibilities of Capacitive Energy Storage in Metro Railcar by Simulation Istvan Szenasy Szechenyi University, Dept. of Automation, Gyor, Hungary mailing address: Istvan Szenasy Dr Gyor, 9023 Almos 18. Hungary fax: 36-96-503461 e-mail: szenasy@sze.hu preferred topic aerias: Energy efficiency in transportation, Renewable energy sources Transportation applications Abstract This paper focuses on the use of modeling and simulation for one of the renewable energy. The supercapacitors contribute to the rapid energy recovery associated with regenerative braking in electric vehicles. This power system allows the acceleration and deceleration of the vehicle with a lower loss of energy. Short-distance passenger traffic on electrified lines is a domain where brake energy recuperation might reduce the total energy consumption significantly. In this paper are presented the results of simulation models by Matlab-Simulink for an urban-metro railcar and some methods for reduce the need value of capacitance. The aim of the management of the energy storage system for improving performance is presented. Keywords : electric vehicle, regenerative braking, energy storage, supercapacitor, Matlab simulation.

I. INTRODUCTION Reducing energy consumption is a priority to rail system operators. Regenerative braking was introduced in most countries to reduce energy consumption. This is only effective if other trains are available to use the regenerated energy. Regeneration also causes further voltage regulation issues, introducing voltage surges. Recent developments in energy storage devices, particularly supercapacitors and flywheels have made energy storage as viable technology to apply to railway systems. Energy storage devices can be used to tackle the issue of poor voltage regulation and help improve energy efficiency by storing regenerated energy from braking. This paper investigates the use of energy storage in mass transit systems, using Budapest Metro Railway as a theoretical case study. For improving the better use of the built energy storage devices some ideas and conceptions were investigated trough different way by a supposed energy management. II. REGENERATIVE BRAKING Regenerative braking generates electrical energy onto the overhead line. This energy can be used by other trains. By regenerating onto the overhead line, overall system efficiency gains can be made. For operational purposes, the overhead line voltage is limited; regenerated currents have to be control so that this limited is not exceeded. The effectiveness of regenerative braking is dependant on the receptivity of the system. If no other trains are motoring within the section, the regenerated energy cannot be used, and the energy has to be dissipated through resistor banks. The issues associated with regenerative braking; particularly on DC systems can be avoided by using energy storage devices. The energy storage devices can store regenerated energy on board trains or at the track side, hence reducing the magnitude of voltage swells too. On board stored energy provides an additional power source for acceleration, hence reducing the acceleration currents drawn from the overhead line and therefore reducing the magnitude of voltage sags. III. POSSIBILITIES FOR ENERGY STORAGE Supercapacitors are new components that can be used for short-duration energy storage. Its power density (W/kg) is similar for classical capacitor, but the stored energy density (Wh/kg) is much higher for supercapacitor. In comparison to standard batteries, the energy density of supercapacitor is lower by an average factor of 10, but their energy density is compatible with a large range of power applications that need high instantaneous power during short periods of time. These characteristics are typically found in transportation systems. Figure 1. Railcar model IV. ABOUT THE INVESTIGATIONS The aim of this paper is to present how supercapacitive storage can be used for increasing the energy efficiency in a metro railway system. More train of railcars have DC drive via 4/4 operated converters. In this railcars yet can be imaginable a capacitive energy-storage device. Main railcar characteristics are: weight w/o load 34 t, weight fully loaded 44 t, the DC motors power 4x50= 200 kw, the maximum speed 85 km/h and maximum acceleration more then 1 m/s 2, and the average distance is approximately 1000 m between stations. The aim of the investigation is to determine the least needed capacitance value of the supercapacitor (C) for different conditions. The base initial conditions were this: the distance between stations is 1200m, the mass one of the railcar is 40t, the speed maximum is 80km/h, the grade is 0 %o. In the Fig. 1 is shown the railcar model. The Fig. 2 shows the direction of the simulation. The first attained object was the value of the initial value of supercapacitor (C) voltage 840V, which we can calculate from the value of the capacitance C and the beforehand filled energy Ec o into C for attain to this voltage. The maximum voltage of the grid is 900V. The least voltage through the discharge is select for 20 to 40 V what we set by tuning the variation of this beforehand filled energy E co and the constant filling power P ct through of the executives of the program Matlab- Simulink. Without the constant filling power P ct it is need a significantly higher value of the C. Input Electric Drive Model and Railcar Model Energetic Calculations Figure 2. Aim and direction of simulation and calculations

This nature of this system was yet manifested at the beginning of the investigations through the executives. The adequate degree of the constant filling-power P ct is determined by the energy consumption of the motors, namely from the conditions of the transport and the parameters of the railcar. Accordingly the important aim of the investigation was to determine the adequate value of the constant filling-power P ct and the least capacitance value for C. The executives of the program were through two distances of the stations. The model calculated the energy consumption of the railcar and the diverse losses too. The values of the motors energy consumption E mot are plotted too on the figures where these values took into consideration the regenerated energy. Practically the energy consumption is divided by the running time given the approximate value of the constant filling-power P ct that it was needed to tuning. The benefits of the applications of the constant fillingpower are: -significantly lower need of capacitance, -more equable load of the grid, -the losses of the grid are lower on the motoring operation mode also. The disadvantages are: -its need to determine the estimated value of the constant filling-power in advance and to integrate the power of the motors and to compare these and if it is needed to correct those. All theses are been stored in the railcar controller and recallable. -it must be controlled the DC-DC converter of the supercapacitor such the adequate value of the constant filling power must be realized together with the motoring operation. During the simulations we calculated the value of the filling power P ct what was constant during an actual executive. In this work the investigation is mainly theoretical so the value of the d Figure 4. Motors energy consumption E mot, constant filling power as filled energy E t (if t=0 then E t =Ec o ), energy of supercapacitor E c, supercapacitor voltage U c v. time d=( Uc min /Uc max )100 (1) is tolerated about 2-5%. In a real application this value of the d would be impermissible low. V. ANALYSES OF COURSES The speed, the covered distance, the motor currants and the energy losses are shown on Fig. 3. The mass is 40t, grade are -20, 0, 30%o, distance on between station is 1200m, but on this two times 1200m done during in 200s. The effects of the grade differences for these curves are hardly visible. In Fig. 4 shown is the same case as in figure 3. Here are the energy level and voltage of supercapacitor (C). It is visible well that the end of the middle curve the grade 0 %o among three is as high as the curve of the Figure 3. Speed, covered distance, motor currants, motor powers, energy losses v. time during two distance of between stations Figure 5. Without the constant filling-power P ct the minimum value of the C is short

constant filling power in the end. This constant filling power here is yet insufficient for the case of 30%o grade. The voltage of C here is lower then 0 what is not possible in an electrolytic supercapacitor and is not allowable. In Fig. 5 the curves are shown here for two distances between stations too. Without the constant filling-power P ct the calculated and tried minimum value of the C is short. The energy deficit at t=200 s to benchmark against the value of the beforehand filled energy Ec 0 are1.6 kwh and 1.9 kwh at this two cases of the grades, -30 és -50- +50%o. In the second case the grade is -50%o at first distance between stations and 50%o at one of the second. If it would be permissible the change of the polarization of the supercapacitor C, in this case would run the curve of U c as shown here and the values of the voltage C would be negative. Sufficient value for the constant filling-power P ct allows operating at minor value of the C. The energy management is manipulated by the controller, but its require for this the sizing of the C minimum in consideration of the prospective maximum values of the mass, speed, distance between stations and grades. There is an important aspect by the setting of the P ct providing for sufficient reserve capacitance in the supercapacitor-storage. The actual values of the P ct are set by the controller by stored samples and the trends of the value energy level E c and U c respectively. The samples may be recorded e.g. on some trial runs, or simulated fitting for an actual track in real-time way by the controller. In Fig. 6 the values of the speed maximum are varied from 50 to 100km/h. Because of this at lower speeds the later points of the curves are slide on the time axis. In Fig. 7 shown the minimum needed values in (F) of the supercapacitor capacitance C as two-variable function v. Figure 7. The minimum value of capacitance C=f(speed, distance). the speed (km/h) and distance between stations, (m): C=f(speed, distance) (2) This function is three-degree for the speed and twodegree for the distance. This two-variable function is fitted very good and controlled with least square method by Matlab: C=Z = (5.5e-6*X 3 + 0.0011*X 2-0.0091*X+1.2251-2e- 05*Y 2 +0.0355*Y-10.7719)*0.5 (F) (2) In Fig. 8 is shown the two-variable function of the constant filling power where P ct =f(speed, mass) (4) In Fig. 9 and Fig. 10 are shown the two-variables functions of the constant filling power P ct and the need initial values of Ec 0. The need initial values of Ec 0 in this function are Figure 6. The speed is varied. Speed v, motors energy consumption E mot, constant filling power as filled energy E t (if t=0 then E t =E co ), supercapacitor energy E c, voltage U c v. time Figure 8. The constant filling power P ct =f(speed, mass)

Figure 11. The energy saving v. speed function (m=40 t, distance = 1200 m, grade=0) Figure 9. The need constant filling power P ct =f(distance, mass) Ec 0 =f ( mass, speed) = 0.0119*X+0.0599+0.0003*Y 1.6881, (5) and Ec 0 =f (distance, speed) = -2e-06*X 2 +0.0026*X- 0.4182+0.0119*Y+0.0599 (6) The effects of the distances to the functions are negligible if the distance is over 700m. The size of the built-in C is given by the functions C=f(distance, mass) and C=f(distance, speed) from the transport task. With apply the value Ec 0 from the functions Ec 0 =f( mass, speed) and Ec 0 =f(distance, speed) (7,8) we can give an initial voltage U c =840V for the supercapacitor. In Fig. 11 shown the energy saving in (%) v. speed, calculated from the energy consumption of motors, the electrical energy loss and regenerative energy. Figure 10. The need initial values of Ec 0 =f(distance, speed) VI. RESULTS In this paper we presented to determine the minimum need values in (F) of the supercapacitor capacitance C, the functions of the constant filling power P ct and the need initial values of the beforehand filled energy in the supercapacitor Ec 0, and its polynomials which can facilitate to select the value of the capacitance C in case of the given conditions. We presented the reason and the advantages of the beforehand filled energy (Ec o ) and the constant filling power (P ct ) applied in this simulation. REFERENCES [1]P. Barrade: Energy storage and application with supercapacitors. leiwww.epfl.ch/publications/barrade_anae_03.pdf [2]P.Barrade, a. Rufer: High power fast energy exchange between storage system: supercapacitors as energy buffer in transportation systems. leiwww.epfl.ch/publications/ destraz_barrade_rufer_pesc_04.pdf [3]J.W. Dixon, M. Ortúzar, J. Moreno: Monitoring system for testing the performance of an electric vehicle using ultracapacitors. www2.ing.puc.cl/power/publications/electronics.htm - 38k [4]M. Chimera, A. Renfrew, M. Barnes: Energy storage devices in railway system. www.iee.org/oncomms/ pn/railway/06innovation_chymera.pdf [5]A. Rufer, P. Barrade: A supercapacitor based energy storage system for elevators with soft commutated interface. ieeexplore.ieee.org/iel5/7586/20673/00955719.pdf [6] I. Szenasy: Modeling and simulation for the energy storage by ultracapacitor in urban rail car. ECT 2008 Conf. Kaunas, Lithuania. [7] I. Szenasy: Dynamic energy storages applications for metro railcars with computed simulation. Dissertation for Budapest Technical University, 1994 (in Hungarian).