ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Similar documents
ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Thermal overload relay TF65 and TF96

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Mini contactors B6, BC6 with 3 pole

Manual motor starter magnetic only MO325

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Manual motor starter MS132

Manual motor starter MS132

Manual motor starter MS132

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Manual motor starter MS116

Manual motor starter MS116

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starters Overview and benefits

Selective main circuit breakers S 750 series Technical Data

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Motor Starter Reverse MSR22-FBP

Mini Contactors Applications and Segments

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Moving Coil Indicators with direct temperature sensor input

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Technical Description. Wireless Automation Accessories

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

EAS822 (Contrac) Power Electronic Unit

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Thermal Overload Relays

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

Electronic Circuit Breaker ESS20-0..

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZP2.5-PE Spring Terminal Block Ground

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4 Screw Clamp Terminal Blocks Feed-through

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ABB central inverters PVS to 2091 kva

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

ZS50-PE Screw Clamp Terminal Blocks Ground

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Emergency stops Award winning design

ZS4-PE Screw Clamp Terminal Blocks Ground

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

ZS35 Screw Clamp Terminal Blocks Feed-through

Product information. ECOSS Electronic compact starter for wound rotor drives

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

Voltage limiting device HVL

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

TriLine PowerModules Overview with Planing Examples

ZK6 PI-Spring Terminal Blocks Feed-through

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Low Voltage Systems MNS and MNS is PowerCenter

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

DBL distribution blocks 3x1 pole

ZP2.5-4P Spring Terminal Block Feed-through

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Voltage limiting device HVL

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

ZK4-PE PI-Spring Terminal Blocks Ground

Valve Drive EnOcean SE/K Product Manual

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Short form catalogue Motor protection and control Manual motor starters

PQstorI One stop solution for energy storage and power quality

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

Transcription:

ABB i-bus KNX HIL/S 20.1.1, Hotel IP Link, Bundle Description of product HIL/S 20.1.1 Hotel IP Link, Bundle The Hotel IP Link is used to connect zones of up to 20 KNX TP devices with central systems (such as Visualizations or Hotel Management Systems). The bundle consists of 2 components: SV/S 30.200.3.1 Power Supply Zone The KNX power supply generates and monitors the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. IPS/S2.1 IP Interface The IP Interface is a modular installation device (MDRC) and forms the interface between KNX installations and IP networks. KNX devices can be programmed via the LAN using ETS 3.0f or higher. The device uses the KNXnet/ IP protocol from the KNX Association (Tunnelling). The IP address can be fixed or can be received from a DHCP server. The power supply range is from 10 to 30 V DC. The additional 30 V DC short-circuit and overload protected voltage output is used to power the IPS/S 2.1.

Technical data SV/S 30.200.3.1 Supply Supply voltage U s 100 240 V AC, (+10 %/ 15 %), 50/60 Hz (85 265 V AC) Power consumption Normal operation 12.5 W Maximum 30 W Outputs Power loss KNX voltage output U n1 Normal operation 2.5 W Maximum 6 W 1 line with integrated choke for 20 devices without choke - Rated voltage U n1 30 V DC +1/-2 V, SELV Voltage output U n2 - Rated voltage U n2 30 V DC +1/-1 V, SELV The voltage output without choke may only be used to power the IPS/S 2.1. Current Rated current I n1 200 ma Current Overload current I ÜL 0.4 A Current Short-circuit current I K 0.7 A Power failure buffering time 100 ms Connections KNX Bus connection terminal Mains voltage input and Auxiliary Output U n2 Tightening torque Screw terminal 0.2 2.5 mm 2 fine-strand 0.2 4 mm 2 solid Maximum 0.6 Nm Operating and display elements LED status (two-colored green/red) Green: U n1 = Ok, I < I ÜL Red: overload Red, flashing: short-circuit Degree of protection IP 20 to DIN EN 60 529 Protection class II to DIN EN 61 140 Isolation category Overvoltage category III to DIN EN 60 664-1 Pollution degree 2 to DIN EN 60 664-1 Temperature range Operation - 5 C +45 C Storage -25 C +55 C Transport -25 C +70 C Ambient conditions Maximum air humidity 95 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, Pro M Main dimensions 90 x 72 x 64.5 mm (H x W x D) Mounting width 4 x 18 mm modules Mounting depth 64.5 mm Mounting On 35 mm mounting rail to DIN EN 60 715 Mounting position As required Weight Approx. 0.26 kg Housing, color Plastic housing, gray Approvals KNX under EN 50 090-1, -2 CE mark In accordance with the EMC guideline and low voltage guideline 2 2CDC502097D0202 HIL/S 20.1.1

Technical data IPS/S 2.1 IP Interface Supply Supply voltage U s 10 30 V DC via plug-in terminal Ripple: < 5 % Power consumption Maximum 1.9 W at 10 V Current consumption Maximum 190 ma at 10 V Leakage loss Maximum 1.9 W at 10 V Rated voltage U n 12 V DC Rated current I n 145 ma at 12 V Current consumption KNX From KNX < 10 ma Connections KNX Bus connection terminal Plug-in terminal for operating voltage Plug-in terminal LAN RJ45 socket for 10/100BaseT, IEEE 802.3 networks, AutoSensing Operating and display elements LED red and button For assignment of the physical address LED green Operating mode display LED yellow Network connection indicator KNX telegram traffic indicator Enclosure IP 20 to DIN EN 60 529 Safety class II to DIN EN 61 140 Isolation category Overvoltage category III to DIN EN 60 664-1 Pollution degree 2 to DIN EN 60 664-1 KNX safety extra low voltage SELV 24 V DC Temperature range Operation 0 C +45 C Storage -25 C +55 C Transport -25 C +70 C Ambient conditions Maximum air humidity 95 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, Pro M Dimensions 90 x 36 x 64 mm (H x W x D) Mounting width 2 modules at 18 mm Mounting depth 68 mm Installation On 35 mm mounting rail to DIN EN 60 715 Mounting position As required Weight 0.100 kg Housing, colour Plastic housing, grey Approvals KNX to EN 50 090-1, -2 CE mark In accordance with the EMC guideline and low voltage guideline HIL/S 20.1.1 2CDC502097D0202 3

Software Device type Application Max. number of group objects Max. number of group addresses Max. number of associations IP/S 2.1 IP Interface 0 0 0 Ordering details Device type Product Name Order No. bbn 40 16779 EAN Weight 1 pcs. [kg] HIL/S 20.1.1 Hotel IP Link, Bundle, MDRC 2CDG110237R0011 01581 3 0,36 1 Packaging [pcs.] NOTE The programming requires EIB Software Tool ETS3 V3.0e or higher. If ETS3 is used a *.VD3 or higher type file must be imported. The application program is available in the ETS3 at ABB/System devices/interfaces. The device does not support the closing function of a project or the KNX device in the ETS. If you inhibit access to all devices of the project with a BCU code (ETS3), it has no effect on this device. Data can still be read and programmed. 4 2CDC502097D0202 HIL/S 20.1.1

IMPORTANT If the device overheats due to extended overload (> 100 C in housing) it switches off automatically. The LED is off. The device can be switched on again only after it has been disconnected from the mains for 60 seconds and has cooled to operational temperature internally. Eliminate the cause of the overload before switching back on. When commissioning the device, ensure that the rated current is not continuously exceeded. The voltage output without choke (U n2 ) is not electrically isolated from the KNX voltage output (U n1 ). It may only be used to power the IPS/S 2.1. Devices are designed for continuous operation. They are not approved for frequent switching on and off. HIL/S 20.1.1 2CDC502097D0202 5

Connection 10 1 Us 2 3 L N 0.6 Nm Us = 100-240 V AC 50 / 60 Hz t a = 45 C Un1 Un2 11 green: Un OK red: Overload 13 12 0.6 Nm IPS/S 2.1 U n2 = 30 V DC U n1 = 30 V DC I n2 = ISupply IPS/S I n1 = 200 ma 2CDC072032F0017 LEGENDE 1ON LED 2LAN/LINK LED 3Telegram LED 4Supply voltage connection 5Bus connection terminal 6Programming LED 7Programming button 8Label carrier 9LAN connection 10 Power supply connection U s 11 Status LED 12 IPS/S 2.1 connection 13 without function 6 2CDC502097D0202 HIL/S 20.1.1

Dimension drawing 108 1 Us 2 3 L N 0.6 Nm Us = 100-240 V AC 50 / 60 Hz t a = 45 C Un1 Un2 0.6 Nm IPS/S green: Un OK red: Overload U n2 = 30 V DC U n1 = 30 V DC I n2 = ISupply IPS/S I n1 = 200 ma 2CDC072030F0017 HIL/S 20.1.1 2CDC502097D0202 7

ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further Information and Local Contacts: www.abb.com/knx Copyright 2018 ABB. We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of this contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Order Number 2CDC502097D0202 (03.2018)