EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

Similar documents
22C, 22CX, 22CX5, 26LC Series

HERZ Motorised Actuator

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

I ntroduction. VA-7450 Electronic Terminal Unit Valve Actuator. Features and Benefits

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

VA-7450 Series. Electric Valve Actuators

MVD, MV, MKV, MKL, 2161C, MXV Series

2-Way & 3-Way Non Spring Return Characterized Ball Valves

NV Direct Coupled Globe Valve Actuator

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Fan-coil valves Series

VA-715x Electric Valve Actuator

SAX Electronic Valve Actuator

Overview of types. Technical data

Actuator for mixing valves 0262EN March 2016

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

VA-4233-GGx Series Electric Valve Actuators

VE-S_15-32 Pressure Independent Balancing & Control Valves

AV-8020 Series Floating Control Actuated Valve

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

VG8000N Series PN16, DN15 - DN150

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

Actuator type ABNM with Theft Protection, 0-10 V Proportional

VG9000 Flanged Valves

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Harmony Installation, Operation and Maintenance

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

VA-715x Electric Valve Actuator

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Paddle-wheel flow controller for On/Off control

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

CV 206/216/306/316 GG. Standard control valves 2- or 3-way, DN , cast iron

Paddle-wheel flow controller with optical principle for On/Off control

Electromotoric actuators

Differential Pressure Sensors

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

Paddle-wheel flow controller for On/Off control

Pressure Independent Control Valve

TA-6-way valve. Standard control valves 6-way valve for change-over systems

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Smile 11 RA/-B Smile 12 RF/-G Reset button

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Electronic Globe Valves

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

MVF461H Series Modulating Control Valves with Magnetic Actuators, Positioning Control and Position Feedback for Hot Water and Steam

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Globe Valve Model Description Globe Valve, Hot Water or Steam Applications

8000 Series Liquid Flow Meters

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

VPA Series and VAP Actuator

Type A - PICV Actuator Series

Connections (*) Actuator Power MVX V ON/OFF MVX41 MVR24V MVR24MV (3) 24 V. Rev. h 07/10 1 DBL199E

G3PE-Single-phase. Solid State Relays for Heaters

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

VA-707x. Thermal Valve Actuators. Product Bulletin. Low and line voltage models available

MVE2XX. Globe Valves Actuators. Power. Model Force (N)

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

Digital display Pressure range ON/OFF output Linear output Model

VE-x Plug & Seat Valve Assemblies

RUS-L24-MOD Electric 24 Volt Modulating Control Damper & Louver Actuator

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Differential Pressure Sensors

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

Emergency lighting units EM series

RUS-L24-MOD Electric 24 Volt Modulating Control Damper Actuator

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

VA-7000 SERIES ACTUATOR

EMO TM. Actuators High performance proportional actuator For modulating control

Actuators for modulating control AME 110 NL, AME 120 NL

M9220-xxx-3 Electric Spring Return Actuators

Control solutions Biofloor

M9216 Series Electric Spring Return Actuators

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

VA-720x Electric Valve Actuator

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option)

AEL5 Series Electric Linear Actuators for ½" to 4" Control Valves

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Selection Guide. Vx-2x13-5xx-9-xx Series Vx-2x13-8xx-9-xx Series VB-2x xx Series. Schneider Electric Ball Valve Assemblies

Suitable to Johnson Controls and almost all of terminal unit valve on the market

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

Actuators for small valves

Preassembled manifolds with flow meter, series CPRFL

ECONOMISER SERIES E2T USER MANUAL

FSP Fan Speed Power Module Technical Data

M9109 Series Electric Non-spring Return Actuators

Valve Body Material:Ductile iron QT Caliber:DN50...DN250 Standard of flange connection in accordance with ISO7005-2

Tina 11A Connection block

2-Color Display High-Precision Digital Pressure Switch

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Transcription:

EMUJC Series Electronic actuator Technical Data Sheet WattsIndustries.com

Description Watts Water Technologies, Inc. The actuator EMUJC Series is an electronic device with 3-point or proportional control signal (see technical features). It is distinguished by its compact footprint, which makes installation in small spaces possible; the actuator can be easily coupled with compatible valve bodies (2131-3131-4131, DYN Series) without any hydraulic operations (system drainage). The actuator s operating status (On, Off, End stroke) is clearly indicated by a LED. EMUJC Compact electronic actuator for terminal units. Three-point or proportional control signal. Coupling with 2131-3131-4131, DYN Series valves by means of brass threaded ring nut (M30x1.5). Diagnostics of actuator operating status by means of LED: On-Off, End stroke reached, in-progress stroke positioning. Cable length: 2m. Nominal thrust: 120N. Degree of protection: IP43. Ambient temperature: 0 50 C. Compliant with LVD 2014/35/EU, EMC 2014/30/EU. Type Part no. Control signal Power Consumption Weight (Kg) EMUJC EMUJC-230 3-point 230V 6,5VA 0,2 EMUJC EMUJC-24 3-point 24V 2,5VA 0,2 EMUJC EMUJC-010 Proporzional 0-10V (2-10V) 24V 2,5VA 0,2 Technical features Model EMUJC-010 EMUJC-24 EMUJC-230 Action/Control proportional 3-point 3-point Power supply 50/60Hz-24 Vac ±15% 50/60Hz-24 Vac ±15% 50/60Hz - 230 Vac ±15% Control signal Impedance (power signal) Power consumption 0 10 Vdc (1), 2 10 Vdc 0 5 Vdc, 5 10 Vdc 0 20 ma, 4 20 ma power: >100 kω current: 500 kω 24 Vac 230 Vac - - 2,5 VA (2) 2,5 VA (2) 6,5 VA (2) 1,5 W (3) 1,5 W (3) 2,2 W (3) Electrical protection IP43 IP43 IP43 Stem stroke 3,2 (1) - 4,3-5,5 mm Max 6,3 mm Max 6,3 mm Nominal thrust 120 N +30% - 20% 120 N +30% - 20% 120 N +30% - 20% Stroke time 8 seconds 13 seconds 13 seconds Operating status Bi-coloured LED green/red green LED green LED Coupling ring nut M30x1,5 M30x1,5 M30x1,5 Electric cable 3x0,35 mm 2 2 meters 3x0,35 mm 2 2 meters 3x0,75 mm 2 2 meters Ambient temperature 0 50 C 0 50 C 0 50 C Storage temperature Operating humidity and storage Temperature of fluid -20 65 C -20 65 C -20 65 C Non-condensing Non-condensing Non-condensing Min 0 C Max 95 C Min 0 C Max 95 C Min 0 C Max 95 C Noise level < 30 db(a) < 30 db(a) < 30 db(a) Material: housing stem ring nut ABS + PC PA66, 30% glass filled Nickel-plated brass Note: (1) Factory setting, (2) Apparent, (3) Active ABS + PC PA66, 30% glass filled Nickel-plated brass ABS + PC PA66, 30% glass filled Nickel-plated brass 2

Application Watts Water Technologies, Inc. The electronic actuators EMUJC Series, coupled with the valves 2131-3131-4131, DYN Series, are used in heating and/or air-conditioning systems to control the heat emission of the single terminal units. Operation The operation of the EMUJC Series actuator is based on the rotation of a shaft driven in either direction by a set of gears. The latter are, in turn, driven by a bidirectional synchronous motor through a magnetic coupling which limits the torque transmitted and therefore also the linear output force. The actuator and valve body (Fig.1) are coupled by means of a threaded ring nut. The movement of the actuator is transmitted to the stem of the valve by axial contact and is kept constant by means of a spring situated inside the valve body. In this way, the valve opening and closing forces are obtained, in one direction, through the thrust exerted by the actuator (Fs opens way B-AB, Fig.2) and, in the other direction, through the force of the spring (Fm opens way A-B, Fig.2) situated inside the valve itself. The valve remains open if the actuator is removed from the valve body. Actuator - valve coupling by means of threaded ring nut Fs Fm A AB B B Fig.1 Fig.2 Models with three-point control (EMUJC-230 and EMUJC-24) Action When the actuator is powered between terminals 1 and 2, the stem extends. When power is removed, the actuator remains in position. When the actuator is powered between terminals 1 and 3, the stem retracts and when the signal is removed, the actuator remains in position. On the other hand, if the actuator remains powered, it stops automatically about 90 seconds after reaching the end stroke position. Action EMUJC-230 cable colour EMUJC-24 cable colour Stem movement terminal 1 terminal 2 Blue Brown Black Red The stem extends terminal 1 terminal 3 Blue Orange Black Orange The stem retracts End stroke If the signal is continuously applied in the same direction, every 2 hours the actuator starts up for about 90 seconds (in keeping with the signal direction applied), to confirm the end stroke position. Check of operating status Models with three-point control are fitted with green LEDs to indicate the operating status: LED Signal Meaning Off Flashing green Steady green Actuator not powered Stem moving or Confirmation of end stroke position End stroke position reached 3

Watts Water Technologies, Inc. Model with proportional control (EMUJC-010) Action When the control signal increases (from 0 to 10 V) in Direct Action (DA) configuration the stem extends, and in Reverse Action (RA) configuration, the stem retracts. When the control signal decreases (from 10 to 0V) in Direct Action (DA) configuration the stem retracts, and in Reverse Action (RA) configuration, the stem extends Action Control signal Stem movement Direct Action (DA) 0 10 Vdc The stem extends 10 0 Vdc The stem retracts Reverse Action (RA) 0 10 Vdc The stem retracts 10 0 Vdc The stem extends End stroke If the signal is continuously applied in the same direction, every 2 hours the actuator starts up for about 60 seconds (in keeping with the signal direction applied), to confirm the end stroke position. Self-calibration When it is powered, the actuator self-calibrates its end stroke position. The actuator drives the stem out for the whole available stroke of the valve until it no longer detects movement of the plug and it memorises its position. At the end of the self-calibration cycle, the actuator positions the stem according to the control signal. Control segnals The actuator is set up to receive the following user-selected input control signals: 0 10 Vdc 2 10 Vdc 0 5 Vdc 5 0 Vdc 0 20 ma 4 20 ma Check of operating status The model with proportional control is fitted with a bi-coloured LED (green/red) to indicate the operating status: LED Signal Meaning Off Flashing green Steady green Flashing red Steady red Actuator not powered Stem moving or Confirmation of end stroke position Position reached Self-calibration cycle No input signal (when set at 2 10V o 4 20 ma) 4

Installation Watts Water Technologies, Inc. Take the precautions below to install the EMUJC Series electronic actuators: 1. Position the actuator above the valve and manually screw on the ring nut (Fig.3). Do not use tools that could damage the actuator. 2. Make sure there is enough room for assembly and disassembly (Fig.4). 3. Install vertically or horizontally, making sure the actuator is at an angle of less than 90 (Fig.5), because any leakage from the valve could cause irreparable damage to the actuator. 4. Do not cover the actuator with insulating material to avoid overheating. 5. Never use the actuator as leverage to assemble the valve. >15 cm Max 90 C Max 90 C NO Fig.3 Fig.4 Fig.5 Max 90 C Max 90 C Electrical wiring BLACK RED ORANGE BLACK RED ORANGE BLUE BROWN ORANGE BLU BROWN ORANGE When wiring the EMUJC Series electronic actuators,take the following precautions: 1. Electrical wiring must be done by authorised personnel, in compliance with the laws of the country of installation. 2. Mains voltage and low voltage must be powered separately. 3. Make sure the power supply conforms with the actuator voltage. N L1 230VAC N L1 230VAC 4. Before switching on, check all the wiring connections. 5. Short-circuited or improperly connected wires could cause permanent damage to the appliance. 6. The colours of the wires may change so always refer to the wiring diagrams shown on the cover of each actuator. BLUE RED GREY BLACK REDBLACK ORANGE RED ORANGE BLACK REDBLACK ORANGE RED ORANGE BLUE BROWN BLUE ORANGE BROWN ORANGE BLU BROWNBLU ORANGE BROWN ORANGE AC (-) (+) N L1 N230VACL1 230VAC N L1 230VAC N L1 230VAC BLUE RED BLUE GREY RED GREY AC AC (+) (+) (-) (-) 5

Watts Water Technologies, Inc. Configuration The actuators with three-point control (EMUJC-24 and EMUJC-230) do not need any initial set-up. The proportional actuator (EMUJC-010) can be configured on the basis of the input signal, the desired action and the required stem stroke. The main configurations are shown below. For more information refer to the instruction sheet. DIP SWITCH ON OFF 0..10VDC 0..20mA DA LIN VDC 0..5VDC 5..10VDC RA Eq% ma 2..10VDC 4..20mA 1 2 3 4 5 6 ON OFF 1: 2: 3: RANGE COMMAND SIGNAL 4: ACTION 5: CURVE 6: SIGNAL TYPE Dip switch Switches 1-2-3 Switches for setting the control signal. Switch 6 must be selected as a consequence. Switches 4 Switch for setting the actuator action: DA = Direct Action, RA = Reverse Action. Switch OFF - DA Switch ON - RA Switches 5 Switch for setting the control characteristics. Switch OFF = linear output to use with linear or equal percentage valves. Switch ON = pseudo equal percentage output to use with quick-opening or on/off valves. Switches 6 Switch for setting the type of control signal. Switch OFF = signal voltage Switch ON = signal current This switch must be set on the basis of switches 1, 2 and 3 NOTE: all switches are factory set in the OFF position. 6

Jumper Watts Water Technologies, Inc. The correlation between the positions of the jumper and the stroke of the actuator stem is shown below. 6 6 6 3.2 mm 4.3 mm 6 mm NOTE: the stroke is factory set at 3.2mm Overall dimensions (mm) EMUJC 80 73.6 M 30 x 1.5 49 60 20 Specification text EMUJC Series Compact electronic actuator for terminals EMUJC Series WATTS brand. Three-point or proportional control signal. Coupling to the valves by brass threaded nut M30x1.5. Diagnostics of actuator status by LED: On-Off indication, limit switch reached, positioning in progress. Power cable length: 2m. Nominal thrust: 120N. Degree of protection: IP43. Ambient temperature: 0 50 C. Compliant with LVD 2014/35/EU, EMC 2014/30/EU. 7

The descriptions and photographs contained in this product specification sheet are supplied by way of information only and are not binding. Watts Industries reserves the right to carry out any technical and design improvements to its products without prior notice. Warranty: All sales and contracts for sale are expressly conditioned on the buyer s assent to Watts terms and conditions found on its website at www.wattsindustries.com. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any form, unless agreed to in a writing signed by an officer of Watts. Watts Industries Italia S.r.l. Via Brenno, 21 20853 Biassono (MB) Italy Tel. +39 039 4986.1 Fax +39 039 4986.222 infowattsitalia@wattswater.com www.wattsindustries.com EMUJC-TS-IT-W-UK-09-17-Rev1 2017 Watts