GENERAC GUARDIAN SERIES STANDBY GENERATORS

Similar documents
GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

70 kw GENERAC STANDBY GENERATORS. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES: Standby Power Rating Model QT070 (Bisque) - 70 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

GENERAC GUARDIAN SERIES STANDBY GENERATORS

22 kva GENERAC STANDBY GENERATORS ISO. Liquid-Cooled Engine Generator Sets FEATURES INCLUDES:

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

GENERAC QUIETSOURCE SERIES STANDBY GENERATORS

STANDBY GENERATOR 25 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 130 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 100 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

STANDBY GENERATOR 80 kw LIQUID-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model HT kw 60Hz

Siemens Liquid Cooled Standby Generators

Standby Generators. 70kW - Liquid Cooled Gas Engine. Meets 2010 EPA emissions regulations.

Guardian Series. GUARDIAN SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Guardian Series INCLUDES:

Siemens Liquid Cooled Standby Generators

Centurion Series. CENTURION SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Centurion Series INCLUDES:

Quietsource Series ISO. QUIETSOURCE SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES. Quietsource Series INCLUDES:

Standby Generators ISO FEATURES. Standby Generators Liquid-Cooled Gaseous Engine. Standby Generators INCLUDES:

Protector Series ISO FEATURES. Standby Generators Liquid-Cooled Gas Engine INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES:

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector Series

Protector Series ISO. PROTECTOR SERIES Standby Generators Liquid-Cooled Gas Engine FEATURES INCLUDES:

Protector QS Series ISO. PROTECTOR QS SERIES Standby Generators Liquid-Cooled Gaseous Engine FEATURES INCLUDES: Protector QS Series

1P 120/240V, 3600 RPM,

GENERAC GUARDIAN SERIES STANDBY GENERATORS

22 / 27 / 32 / 38 / 48 kw

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

GENERAC GUARDIAN SERIES STANDBY GENERATORS

17 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. INCLUDES: True Power Electrical Technology

Protector Series ISO FEATURES. Diesel Generator Set INCLUDES:

16 kw CENTURION STANDBY GENERATOR. Air-Cooled Gas Engine Generator Sets FEATURES. Standby Power Rating Model (Steel - Gray) - 16 kw 60Hz

SPECIFICATIONS. Stationary Emergency Generator Specifications STATIONARY EMERGENCY GENERATOR COOLING SYSTEM FUEL SYSTEM ENGINE ELECTRICAL SYSTEM

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Standby Rated Generators. Standby SG kva / 184 kw. Prime PG kva / 147 kw

Power Ratings. Standby SG kva / 160 kw. Prime and standby ratings based on 3-Phase voltages. Model number based on kw rating.

Power Ratings. Standby SG kva / 240 kw. Prime PG kva / 192 kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 70 kw 88 kva 60 Hz

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 130 kw 163 kva 60 Hz

STANDBY GENERATORS 17 kw AIR-COOLED GENERATOR SETS

Power Ratings. Standby SG kva / 320 kw. Prime PG kva / 288 kw

Protector Series ISO FEATURES. Diesel Generator Set. Protector Series INCLUDES:

8/10/14kW. 8/10/14kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES INCLUDES:

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 150 kw 188 kva 60 Hz

SG L 35 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

MG L. MG Series Paralleling Unit. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. MG kw

SG L 50 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

17/20kW. 17/20kW. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

SG L 300 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

SG L 250 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency POWERING AHEAD CODES AND STANDARDS

INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency CODES AND STANDARDS POWERING AHEAD

Optimus Residential Standby Generators

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 20 kw 25 kva 60 Hz

G130LG2 6.8L. Industrial Spark-Ignited Generator Set. Codes and Standards. G130LG2 130 kw. Standby Power Rating 130 kw 163 kva 60 Hz

STANDBY GENERATOR 20 kw AIR-COOLED GENERATOR SET INCLUDES FEATURES. Standby Power Rating Model (Steel - Dark Gray) - 20 kw 60 Hz - US

*Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes.

SB500/MB500. Industrial Bi-Fuel Diesel Generator Set. 500 kw Bi-Fuel. features. primary codes and standards. Standby Power Rating 500 kw 625 kva 60 Hz

SB600/MB600. Industrial Bi-Fuel Diesel Generator Set. features. primary codes and standards. 600 kw Bi-Fuel. Standby Power Rating 600 kw 750 kva 60 Hz

G150LG4 12.9L. Industrial Spark-Ignited Generator Set. Codes and Standards. G150LG4 150 kw. Standby Power Rating 150 kw 188 kva 60 Hz

Spark-ignited generator set

MG L 150 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 130 kw 163 kva 60 Hz

SG070. Industrial Gaseous Generator Set. SG070 70kW. primary codes and standards. Standby Power Rating 88kVA 70kW 60 Hz

PROTOTYPE & TORSIONALLY TESTED UL2200 TESTED RHINOCOAT PAINT SYSTEM WIDE RANGE OF ENCLOSURES EPA COMPLIANT INDUSTRIAL TESTED, GENERAC DESIGNED

16/20/22 kw CENTURION SERIES

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 60 kw 75 kva 60 Hz

20 KW / 25 KVA LIQUID COOLED POWERED by

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

Spark-ignited generator set

MD L 400 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

SG L 350 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

SD L 130 kw INDUSTRIAL DIESEL GENER ATOR SE T EPA Certified Stationary Emergency

MDG75DF4 4.5L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

SD L 40 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

9/11 kw. 9/11 kw. GUARDIAN SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES

Diesel generator set QSX15 series engine

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

MDG75DF4 4.5 L 75 kva MOBILE DIESEL GENERATOR SET. Power When and Where You Need It

MDG100DF4CAN 4.5 L 100 kva MOBILE DIESEL GENERATOR SET. Codes and Standards Generac Mobile products are designed to the following standards:

G130LG. Industrial Gaseous Generator Set. G130LG 130kW. primary codes and standards. Standby Power Rating 163kVA 130kW 60 Hz

Rental Power 800 kw. Specification sheet. Description. Features. Options

SD L. Industrial Diesel Generator Set. Powering Ahead. Codes and Standards. SD kw

8/11/13kW. 8/11/13kW. CENTURION SERIES Residential Standby Generators Air-Cooled Gas Engine FEATURES. Includes: Standby Power Rating

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

SG150. Industrial Gaseous Generator Set. SG kW. primary codes and standards. Standby Power Rating 188kVA 150kW 60 Hz

Diesel generator set QSK23 series engine

SD L 1000 kw INDUSTRIAL DIESEL GENER ATOR SET EPA Certified Stationary Emergency

DATA CENTER SOLUTIONS

Transcription:

Includes: Generac Naturally Aspirated GENERAC GUARDIAN SERIES STANDBY GENERATORS 3 kw Gaseous Fueled 1.6L Engine Two Line LCD Tri-lingual Digital Nexus Controller Isochronous Electronic Governor Closed Coolant Recovery System Smart Battery Charger UV/Ozone Resistant Hoses ±1% Voltage Regulation Natural Gas or LP Operation UL 22 Listed Liquid-Cooled Engine Generator Sets Standby Power Rating Model QT3 (Bisque) - 3 kw 6Hz Meets EPA Emission Regulations FEATURES INNOVATIVE DESIGN & PROTO TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN. But it doesn t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERIA: PROTO TESTED SYSTEM TORSIONAL TESTED NEMA MG1-22 EVALUATION MOTOR STARTING ABILITY SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. An unequalled ±1% voltage regulation. SINGLE SOURCE SERVICE RESPONSE from Generac s extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.

Application & Engineering Data QT3 GENERATOR SPECIFICATIONS ROTOR INSULATION STATOR INSULATION Synchronous Class F Class F TELEPHONE INTERFERENCE FACTOR (TIF) <5 ALTERNATOR OUTPUT LEADS 3 PHASE BEARINGS COUPLING LOAD CAPACITY (STANDBY RATING) EXCITATION SYSTEM VOLTAGE REGULATION SENSING 4 wire Sealed Ball Flexible Disc 3 kw Direct Electronic Single Phase REGULATION ± 1% GENERATOR FEATURES Revolving field heavy duty generator Directly connected to the engine Operating temperature rise 12 C above a 4 C ambient Insulation is Class F rated at 13 C rise All models are fully prototyped tested ENCLOSURE FEATURES Galvanized steel weather protective enclosure Enclosed critical grade muffler Small, compact, attractive Ensures protection against mother nature. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation. ENGINE SPECIFICATIONS MAKE Generac MODEL In line CYLINDERS 4 DISPLACEMENT 1.6 Liter BORE 3.15 STROKE 3.13 COMPRESSION RATIO 9.75:1 INTAKE AIR SYSTEM Naturally Aspirated VALVE SEATS Replaceable LIFTER Hydraulic GOVERNOR SPECIFICATIONS Electronic FREQUENCY REGULATION Isochronous STEADY STATE REGULATION ±.25% ENGINE LUBRICATION SYSTEM OIL PUMP Gear OIL FILTER Full flow spin-on cartridge CRANKCASE CAPACITY 4 Quarts ENGINE COOLING SYSTEM Closed WATER PUMP Belt driven FAN SPEED 255 FAN DIAMETER 15 inches FAN MODE Pusher FUEL SYSTEM FUEL Natural gas, propane vapor CARBURETOR Down Draft SECONDARY FUEL REGULATOR FUEL SHUT OFF SOLENOID OPERATING FUEL PRESSURE 5-14 H 2 O ELECTRICAL SYSTEM BATTERY CHARGE ALTERNATOR STATIC BATTERY CHARGER RECOMMENDED BATTERY SYSTEM VOLTAGE 12V 3 Amp 2 Amp Group 26, 525CCA 12 Volts Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO346 and DIN6271). (All ratings in accordance with BS5514, ISO346, ISO8528, SAE J1349 and DIN6271).

Generac Guardian Series Standby Generator - 3 kw OPERATING DATA KW RATING (LP/NG) 3/27 ENGINE SIZE 1.6 Liter 4 cyl. inline GENERATOR OUTPUT VOLTAGE/KW - 6Hz KW AMP CB Size 12/24V, 1-phase, 1. pf 12/28V, 3-phase,.8 pf 12/24V, 3-phase,.8 pf 3 3 3 125 14 9 15 125 1 ENGINE FUEL CONSUMPTION (Natural Gas) (Propane) Exercise cycle 25% of rated load 5% of rated load 75% of rated load 1% of rated load* ENGINE COOLING Natural Gas (ft 3 /hr.) 6 145 26 37 47 Propane (gal/hr.) cu ft/hr.7 24 1.6 58 2.8 13 4. 147 5.1 187 Air flow (inlet air including alternator and combustion air) System coolant capacity Heat rejection to coolant Max. operating air temp. on radiator Max. ambient temperature COMBUSTION AIR REQUIREMENTS ft 3 /min. US gal. BTU/hr. C ( F) C ( F) 1,8 2. 131, 6 (15) 5 (14) Flow at rated power 6 Hz cfm 95 SOUND EMISSIONS IN DBA Exercising at 7 meters Normal operation at 7 meters EXHAUST Exhaust flow at rated output 6 Hz cfm Exhaust temp. at muffler outlet F ENGINE PARAMETERS 62 72 26 125 Rated synchronous RPM 6 Hz 36 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration Altitude Deration 3% for every 1 C above - C 1.65% for every 1 F above - F 1% for every 1 m above - m 3% for every 1 ft. above - ft. 25 77 183 6 * Refer to "Emissions Data Sheets" for maximum fuel flow for EPA and SCAQMD permitting purposes. RATING: All three phases units are rated at.8 power factor. All single phase units are rated at 1. power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-346-1. Design and specifications are subject to change without notice. KW rating is based on LPG Fuel and may derate with natural gas.

NOTE WIRE ORIENTATION C4449A-T INTERCONNECTIONS QT3 UTILITY SUPPLY FROM SERVICE DISCONNECT TRANSFER SWITCH QT SERIES ENGINE GENERATOR CONNECTION PANEL ON UTILITY (C1 & VR1) GROUND 4885-T 194/15B E1 E2 35A LUG 57329-F NEUTRAL BLOCK 194/15B CUSTOMER CONNECTIONS DC COMMON 194 +12VDC TRANSFER WARNING STANDBY (C2 & VR2) E1 E2 T1 T2 T1 E1 E2 T2 NOTE: MATCH WIRE NUMBERS TO TERMINAL NUMBERS GROUND NEUTRAL BLOCK NOTE: POWER LEADS AND TRANSFER SWITCH LEADS TO BE RUN IN TWO DIFFERENT CONDUITS. EXCEPTIONS: IF THE INSULATION RATING ON ALL WIRING IS RATED FOR 6V AND THE LENGTH OF THE CONDUIT IS 3ft OR LESS IT IS ACCEPTABLE TO INCLUDE GENERATOR CONTROL & POWER WIRING IN ONE CONDUIT LIQUID COOLED INSTALLATION CUSTOMER LOAD (DISTRIBUTION PANEL) NEXUS CONTROL FEATURES 2-Line Plain Text LCD Display Simple user interface for ease of operation Mode Switch Automatic Start on Utility failure. 7 day exerciser -Auto -Off Stops unit. Power is removed. Control and charger still operate. -Manual/Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place. Programmable start delay between 1-3 seconds Engine Start Sequence Cyclic cranking: 16 sec. on, 7 rest (9 sec. maximum duration) Engine Warm-up 5 seconds Engine Cool-Down 1 minute Starter Lock-out Starter cannot re-engage until 5 sec. after engine has stopped. Smart Battery Charger Automatic Voltage Regulation with Over and Under Voltage Protection Automatic Low Oil Pressure Shutdown Overspeed Shutdown, 72Hz High Temperature Shutdown Overcrank Protection Safety Fused Failure to Transfer Protection Low Battery Protection 5 Event Run Log Future Set Capable Exerciser Incorrect Wiring Protection Internal Fault Protection Common External Fault Capability Governor Failure Protection *Single and three phase connections may vary, refer to the owner s manual for specific connection information.

INSTALLATION LAYOUT QT3 Generac Power Systems, Inc. S45 W2929 HWY. 59, Waukesha, WI 53189 generac.com 21 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 18768SBY-B / Printed in U.S.A. 6/22/1