INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Similar documents
INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

The insulation tester must only be used by a skilled and competent measuring equipment connected directly to utilization points

operating manual DL7 101 DIGITAL THERMOMETER

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

i400s Calibration Information Introduction

Infrared Thermocouple Probe


4-20mA DC PROCESS CLAMP METER

Calibration Manual. Detachable Jaw True-rms Clamp Meter

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

PY-11 Voltage & Continuity Tester

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Temperature Calibrator

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Tachometer. English. Users Manual

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

SOIL RESISTIVITY TESTER

Users Manual. MegOhmMeter

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

362 Clamp Meter. Users Manual

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

323/324/325 Clamp Meter

DT304. Digital Temperature Logger INSTRUCTION MANUAL

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Go to to register your product and find more information.

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

i3000s/i2000 Flex AC Current Probe

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

302+/303 Clamp Meter. Users Manual

TMD90A Dual Input Digital Thermometer

233 True-rms Remote Display Digital Multimeter Safety Information

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Visit us at

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

80PK-2A Type K Immersion Probe

373 Clamp Meter. Users Manual

KMP Insulation-Continuity Tester. Users Manual

THWD-3 and TH-3 Relative Humidity and Temperature Meters

365 Detachable Jaw True-rms Clamp Meter

Thermocouple Thermometer Models

HIGH VOLTAGE PROVING UNIT

ANALOG INSULATION RESISTANCE TESTER

P5510. Users Manual. Pneumatic Comparison Test Pump

362 Clamp Meter. Users Manual

KMP7010. Ground Resistance Tester. Users Manual

TIME-10 Process Control Stopwatch

DIGITAL EARTH RESISTANCE Model KM 2030

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Users Manual. Phase Rotation Indicator

Operator s Manual TC-253A. Temperature Converter

Barnant Company (Type J) (Type K) (Type T)

TACH-10 Contact / Non-Contact Tachometer

Users Manual. Airflow Meter

IAQ-CALC TM Indoor Air Quality Meter

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

TMA5 Mini Vane Anemometer

712 RTD Calibrator. Instruction Sheet. Introduction

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

Table of Contents. 1. The Statement Overview Instrument Familiarization Method of use General Specifications...

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Safety design conforming to the following provisions

Megohmmeter Test Probe

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

716 Pressure Calibrator

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

Thermistor Thermometer MODEL NO

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

(Type J) (Type K) (Type T)

HIGH VOLTAGE PROXIMITY DETECTOR

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

OPERATING INSTRUCTIONS

INSP-3 Wiring Inspection Tester

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

Single-Input Thermocouple. Thermometers Type J, K, T

Indoor Air Quality Meter

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

IAQ-CALC TM Indoor Air Quality Meter

Instruction Manual. Single-Input Thermistor Thermometer (Model )

Transcription:

DIGITAL THERMOMETERS INSTRUCTION MANUAL ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING Thank you for buying one of our products. For safety and a full understanding of its benefits please read this manual before use. Technical support is available from 01923 441717 and support@martindale-electric.co.uk. CONTENTS 1 Safety Information 1 1.1 Meaning of Symbols and Markings 1 1.2 Precautions 2 2 Introduction 3 2.1 Inspection 3 2.2 Description 3 2.3 Accessories 3 2.4 Battery Installation 3 3 Operation 4 3.1 General 4 3.2 Low Battery Indication 4 3.3 Description of Press Buttons 5 3.4 Description of LCD Symbols 5 3.5 Backlight 6 3.6 Auto Power Off 6 3.7 Temperature Scale Selection 6 3.8 Relative Mode 7 3.9 Data Hold 7 3.10 Record Function 7 3.11 Temperature Measurement 8 3.12 Differential Temperature Measurement (DT175 only) 8 3.13 Thermocouple Offset Adjustment 9 4 Maintenance 10 4.1 Battery Replacement 10 4.2 Calibration 10 4.3 Cleaning 10 4.4 Repair & Service 11 4.5 Storage Conditions 11 5 Warranty 12 Specifications 1. SAFETY INFORMATION REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings that are necessary for the safe operation and maintenance of this product. It is recommended that you read the instructions carefully and ensure that the contents are fully understood. Failure to understand and to comply with the warnings and instructions can result in serious injury, damage or even death. Particular attention should be paid to the Warnings, Precautions and Technical Specifications. Please keep these instructions for future reference. Updated instructions and product information are available at: www.martindale-electric.co.uk 1.1 Meaning of Symbols and Markings Caution - risk of danger and refer to instructions Caution - risk of electric shock Direct and alternating current (AC & DC) Equipment complies with relevant EU Directives End of life disposal of this equipment should be in accordance with relevant EU Directives 1

1.2 Precautions This product has been designed with your safety in mind, but please pay attention to the following warnings and cautions before use. Warnings This unit must NOT be connected to CAT II, CAT III or CAT IV circuits. Before use check the unit for cracks or any other damage. Make sure the unit is free from dust, grease and moisture. Also check any associated leads and accessories for damage. Do not use if damaged. Do not use if the battery cover is not fitted. To avoid electrical shock, and damage to the instrument, do not use this instrument and the associated temperature probe when voltages at the measurement surface exceed 24V DC or AC rms. Cautions To avoid burns or damage to equipment, do not take temperature measurements inside microwave ovens. Repeated sharp flexing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads especially near the connector. Avoid severe mechanical shock or vibration and extreme temperature. 2. INTRODUCTION 2.1 Inspection Examine the shipping carton for any sign of damage. Inspect the unit and any accessories for damage. If there is any damage then consult your distributor immediately. 2.2 Description The DT173 and DT175 are portable, 3½ digit, compact thermometers for use with Type K thermocouples. The DT175 is dual input and may be used in differential mode when thermocouples are connected to both inputs. The DT173 and DT175 have the following functions and features: Temperature range -50 C to 1372 C (-58 F to 1999 F) Thermocouple compensation adjustment Max/Min function Relative function Data hold function Backlight Auto power off Rubberised outer jacket 2.3 Accessories The DT173 and DT175 come with the following accessories: Type K bead thermocouple (x2 for DT175) 4 x 1.5V AAA alkaline batteries Instructions To avoid possible corrosion from leaking batteries, remove the batteries if discharged, or when the unit is not in use for an extended period. 2 2.4 Battery Installation Refer to Section 4.1 (Battery Replacement) for the battery installation instructions. 3 3. OPERATION 3.3 Description of Press Buttons 3.1 General If the thermometer displays OL then the measurement limits of the range have been exceeded. C/ F Power on/off button Selects the temperature scale The maximum temperature measurement of the DT173/ DT175 is 1372 C (1999 F), but the thermocouple probe being used may only be specified to 260 C (500 F). Be sure that the thermocouple probe is adequate for the measurement being made. 3.2 Low Battery Indication If the symbol is displayed the battery needs replacing (See section 4.1 Battery Replacement). ADJ REL HOLD APO Turns on/off the backlight Selects the thermocouple compensation adjustment function Increments thermocouple compensation adjustment value Selects /deselects the relative mode Decrements thermocouple compensation adjustment value Selects/deselects the data hold function Selects/deselects auto power off function (DT173 only) T1-T2 Selects individual thermocouple inputs or the differential mode (DT175 only) MAX/MIN Selects the record function ENTER >2S APO ENTER Saves the thermocouple compensation adjustment value (DT173 only) Hold for >2s to selects/deselect auto power off function (DT175 only) Saves the thermocouple compensation adjustment value 3.4 Description of LCD Symbols RECORD Record function is active MAX Maximum recorded reading is displayed MIN Minimum recorded reading is displayed MAX-MIN Maximum minimum recorded reading is displayed DT173 DT175 4 5 AVG Average recorded reading is displayed

REL Relative mode is selected HOLD Hold function is selected C Celsius temperature scale is selected F Fahrenheit temperature scale is selected T1 Thermocouple T1 input is selected (DT175 only) T2 Thermocouple T2 input is selected (DT175 only) T1-T2 Differential input mode is selected (DT175 only) Indicates battery is low APO Indicates auto power off is activated On power up, the instrument defaults to the scale last selected before power down. 3.8 Relative Mode The relative function is used to remove an offset or residual value from a measurement. Pressing REL will set the display to 0.00. The REL symbol will be To exit the relative function, press REL for >2s. 3.5 Backlight Press to turn ON/OFF the backlight. 3.9 Data Hold To hold a displayed reading, press HOLD. The HOLD symbol will be 3.6 Auto Power Off If the thermometer is inactive for a period of 30 minutes it will automatically power off (except in the record mode). On the DT173, press off function. On the DT175, press power off function. APO to deactivate/activate the auto power >2S APO ENTER for >2s to deactivate/activate the auto The APO symbol will no longer be displayed when deactivated. 3.7 Temperature Scale Selection Readings are displayed in either degrees Celsius ( C) or degrees Fahrenheit ( F). Press C/ F to change the scale. The C or F symbol will be 6 7 To exit data hold press HOLD again. 3.10 Record Function to select the record function. The RECORD symbol will be as required to display the following: Maximum recorded reading. The MAX symbol is Minimum recorded reading. The MIN symbol is Difference between maximum and minimum recorded readings. The MAX-MIN symbol is Average of the recorded readings. The AVG symbol is When in the record function, pressing HOLD will pause the recording. Press again to resume recording. for >2s to exit the record function. Note: When in the record function to avoid the loss of recorded data all buttons are disabled except for HOLD and the backlight. The APO function is also disabled. 3.11 Temperature Measurement Connect a Type K thermocouple probe, suitable for the type of temperature measurement and temperature range being made, to the thermocouple input socket (T1 or T2 or both on the DT175). For the DT175, press T1-T2 to select the thermocouple input to be used. The T1 or T2 symbol will be displayed according to the input selection. Taking all necessary safety precautions position the thermocouple at the surface or in the medium to be measured and read the measured temperature from the display. Note: Repeated flexing can break the thermocouple leads. To prolong lead life, avoid sharp bends in the leads, especially near the connector. 3.12 Differential Temperature Measurement (DT175 Only) Connect Type K thermocouple probes, suitable for the type of temperature measurement and temperature range being made, to the thermocouple input sockets T1 and T2. Taking all necessary safety precautions position the thermocouples at the surfaces or in the mediums to be measured. Press T1-T2 as required, to select the T1-T2 differential mode. The T1-T2 symbol will be The difference between the measured temperatures of thermocouples T1 and T2 will be 8 9 3.13 Thermocouple Offset Adjustment The offset adjustment allows an individual Type K thermocouple to be optimised for the best measurement accuracy at a chosen reference temperature. The adjustment span is ±6.0 C (±10.8 F). On the DT175 set the required input, T1 or T2. Connect the thermocouple to the input socket. Place the thermocouple in a known, stable temperature environment at the reference temperature. E.g. Triple point of ice, calibrated temperature bath, etc. Allow the readings to stabilize. ADJ Press, the SET symbol will be displayed and the temperature reading will flash. REL or Use reference temperature. HOLD to set the indicated temperature to the known Leave sufficient time between adjustments to allow for measurement lag. Press ENTER to exit the adjustment mode and save the offset value. The SET symbol will no longer be displayed and the temperature reading will cease flashing. The thermometer-thermocouple combination is now optimized for measurements at the reference temperature.

4. MAINTENANCE 4.1 Battery Replacement To avoid shock or injury, disconnect the thermocouple/s from any external surface and remove before proceeding. Remove the screw from the battery compartment cover, and lift it off. Fit 4 new 1.5V, AAA alkaline batteries (IEC LR03, NEDA 24A) observing correct polarity. Replace the battery compartment cover and screw. Note: Do not mix old and new batteries. unit. If a mild detergent is used, the unit should subsequently be thoroughly cleaned with a water dampened soft cloth. After cleaning, dry and allow to remain in a dry environment for 2 hours before use. 4.4 Repair & Service There are no user serviceable parts in this unit other than those that may be described in section 4. Return to Martindale Electric if faulty. Our service department will quote promptly to repair any fault that occurs outside the guarantee period. Before the unit is returned, please ensure that you have checked the unit, batteries and thermocouple/s. 4.5 Storage Conditions The instrument should be kept in warm dry conditions away from direct sources of heat or sunlight, and in such a manner as to preserve the working life of the unit. It is strongly advised that the unit is not kept in a tool box where other tools may damage it. 4.2 Calibration To maintain the integrity of measurements made using your instrument, Martindale Electric recommends that it is returned at least once a year to an approved Calibration Laboratory for recalibration and certification. Martindale Electric is pleased to offer you this service. Please contact our Service Department for details. Email: service@martindale-electric.co.uk Tel: 01923 650660 4.3 Cleaning If contamination is found, clean with a damp soft cloth and if necessary a mild detergent or alcohol. Do not use abrasives, abrasive solvents, or detergents which can cause damage to the 10 11 5. WARRANTY AND LIMITATION OF LIABILITY This Martindale product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is 2 years and begins on the date of receipt by the end user. This warranty extends only to the original buyer or enduser customer, and does not apply to fuses, disposable batteries, test leads or to any product which, in Martindale s opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation, handling or storage. Martindale authorised resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Martindale. Martindale s warranty obligation is limited, at Martindale s option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to Martindale within the warranty period. This warranty is the buyer s sole and exclusive remedy and is in lieu of all other warranties, expressed or implied, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. Martindale shall not be liable for any special, indirect, incidental or consequential damages or losses, including loss of data, arising from any cause or theory. Since some jurisdictions do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any part of any provision of this warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision or other part of that provision. Nothing in this statement reduces your statutory rights. 12 13

Specification Specification Input protection: 24V DC or AC rms maximum input voltage on any combination of input pins. Input connector: Accepts standard miniature thermocouple connectors (fl at blades spaced 7.9mm. center to center). ELECTRICAL All specifi ed accuracies are at 23 C ± 5 C, <75% RH for 1 year, not including thermocouple error. Temperature coeffi cient: 0.1 x (applicable accuracy) per C. (0 C to 18 C, 28 C to 50 C) Temperature scale: Celsius or Fahrenheit, user-selectable Thermocouple type: K Measurement range: -200 C to 1372 C. (-328 F to 1999 F) Note: Measurement range will be limited by the range of the thermocouple probe used. Resolution: 0.1 to 199.9 C/ F, 1 200 C/ F Temperature accuracy: Range -200 C to -60 C -60 C to 1372 C -328 F to -76 F -76 F to 1999 F Accuracy ± (0.1% of rdg + 2 C) ± (0.1% of rdg + 1 C) ± (0.1% of rdg + 4 F) ± (0.1% of rdg + 2 F) Supplied thermocouple probe: 4-foot Type K thermocouple bead probe (tefl on tape insulated). Maximum insulation temperature: 260 C (500 F). Probe accuracy: ± 2.2 C or ± 0.75% of reading (whichever is greater). GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999 Measurement rate: 2.5 times/second Polarity: Automatic, positive implied, - for negative polarity indication Overrange: (OL) is displayed Power: 4 x 1.5V, AAA alkaline batteries (IEC LR03, NEDA 24A) Battery life: 200 hours typical with alkaline batteries Low battery indication: Low battery symbol is displayed Auto power off: After 30 minutes Dimensions: 160 mm (H) x 83 mm (W) x 38 mm (D). Weight: Approx. 240g, including batteries Includes: Type K bead thermocouple (x2 for DT175), 4 x 1.5V AAA alkaline batteries and instructions ENVIRONMENTAL Temperature & Humidity: (Operating): 0 C to 50 C, <70% R.H. (Storage): -20 C to 60 C, 0 to 80% R.H., batteries removed Altitude: up to 2000m Pollution degree: 2 SAFETY Conforms to: BS EN 61010-1 Class II, double insulation Specification Check out what else you can get from Martindale: 18th Edition Testers Motor Maintenance Equipment Accessories Multifunction Testers Calibration Equipment Non-trip Loop Testers Continuity Testers Pat Testers & Accessories Electricians Kits Phase Rotation Testers Environmental Products Proving Units Full Calibration & Repair Service Socket Testers Fuse Finders Thermometers & Probes Digital Clamp Meters Test Leads Digital Multimeters Voltage Indicators Labels Specialist Metrohm Testers (4 & 5kV) Microwave Leakage Detectors Specialist Drummond Testers EMC Conforms to BS EN 61326-1 Martindale Electric Company Limited Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900 E-mail: sales@martindale-electric.co.uk Website: www.martindale-electric.co.uk Martindale Electric Company Ltd. 2017 Registered in England No. 3387451. Rev 1 LITDT173/175