Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Similar documents
Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

ExpressLT Dry Dry Loose Tube Cable (2.5 mm)

Fiber Optic, Breakout cable, tight buffered, 900 microns

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Article number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length}

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

Micro Fibre Indoor Cable Multi-core (Up to 96 Fibres) Applications. Features

ezprep Gel-Free Loose Tube Gel-Free Loose Tube Cable (2.5mm)

MIC Unitized Plenum Cables, Fibers

MIC Plenum Cables, 2-24 Fibers

Optical Fibre Fibre Cables

Long Span ADSS All-dielectric self-supporting loose tube cable

ezspan ADSS All-dielectric self-supporting loose tube cable

Mini Breakout Distribution Cable Multi-core ( Fibres)

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

Application Specification. Optical Fiber. Aramid Yarns. 2mm Subunit Jacket. Strength Rods. Outer Jacket

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

HITRONIC HQN Single-mode & Multi-mode Glass Optical Fiber Cable for Outdoor Applications

fiber optic cable Outdoor Cables

Indoor/Outdoor Cables Single-Armored, Plenum, Tight Buffered Distribution Indoor/Outdoor Cable

50µm µlinx Avionics Cable

OPTOFLEX G62,5/125: rubber cables with fiber optic

Volition Fiber Optic Cable

Outside Plant All Dielectric

Datasheet Outside Plant Cable

Plug & Play AnyLAN Systems

MTP Loose Tube Trunk Assemblies. Features. Applications.

FTTH simplex indoor cables with semi-tight tube

Volition. Fiber Optic Cable. 3Innovation

DNV-GL HH CE RoHS-II conform

MPO MicroCable Trunk Assembly

Avionics Optical Cables

Caledonian Fire Resistant Optic Fiber Cables

OAsys. Outside Plant. Metallic Joint Closure VXOK units. Features and Benefits

Fibre optic cables. Guarantee. Fibre optic cables. Information about Fibre optic cables CFLK CFLG88 CFLG.LB.PUR CFLG.LB CFLG.G

Data sheet chainflex CF8821

6491B / H07Z-R / BS EN Cable

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

Data sheet chainflex CF5

Data sheet chainflex CF6

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

Data sheet chainflex CF10

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

Performs under pressure. Our instrumentation cables keep everything in tune.

Data sheet chainflex CFSOFT1

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

Laser Optimized Multimode

Data sheet chainflex CF130.UL

P R O D U C T C AT A L O G T ALOG

Data sheet chainflex CF140.UL

Data sheet chainflex CF9

LANmark-1000 Category 6 Plenum

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

The cables you need when you need them

Interconnect Cable Simplex and Duplex

40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly

Power & Control Cable IEC

Mini-Span ADSS Cable

FiberExpress Distribution Cables Tight Buffer Indoor Riser & Plenum Rated

chainflex type Fibre optic cables* Information fibre optic cables 154 CFLK** PUR 12,5-20/ CFLG.2H CFLG.LB*** TPE 5-40/

Cables for cable carriers and reels SYSTEMS IN MOTION

O P T I C A L F I B R E C A B L E S CONTRIBUTING TO DIGITAL INDIA

CF270.UL.D.

Draka Elevator Catalog

Data sheet chainflex CF240

Power & Control Cable IEC

Outside Plant. Tube Distribution Closure (TDC) MK II. Features and Benefits. Prysmian Part Number: XBFSC Kit Contents.

Crane Cables General Catalogue

flame Retardant overall screened Instrumentation cables (Multicore)

Any inquiries, please feel free to contact or Caledonian

Power & Control Cable IEC

ENERGY. Solar Cables

Cables for Railway Technology

Global data. Electrical parameters

Connecting globally. TFCrane

Industrial Optical Cables

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Telephone Cables Fire Warning Cables

14 HH EAC/CTP CE RoHS-II conform

SY PVC / BS EN Control Flexible Cable

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

CFRIP - tear strip for faster stripping

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

TRIFLEX H07RN-F CPR COMPLIANT REGULATION 305/2011/EU. Low voltage - Energy, cabling, signalling and control. reaction to fire

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

2001 PRODUCT CA T ALOG

CRANE, CONVEYOR, LIFT & REELING CABLES

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

600/1000V, PVC Insulated Cables according to IEC

Transcription:

Universal indoor/outdoor distribution or mini breakout cable with ES9 tight buffer, 2 24 fibres and black FireBur sheath, VDE: U-V(ZN)H Application and Installation This distribution or mini-break-out cable can be used for many indoor applications and outdoor applications The cable features our new and improved ES9 tight buffer. Typical cable applications include: LAN and WAN backbones, central office interconnections, backbones in data centres, and many other. The cable is suited for installation in ducts and on trays. The cable features an UV stabilised, water and moisture resistant FireBur sheathing, the cable is thus well suited for outdoor runs; but is not longitudinal water blocked. Standards ISO 11801 2 nd edition, EN 187 000, IEC 60794-2, EN 50 173-1, IEC 60794-2-20 Flame resistance LSHF (FRNC): IEC 60332-1-2; IEC 60754-2; IEC 61034 Page 1 of 3

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Grey w/mark every 70 mm 4 Yellow 16 Turquoise w/mark every 70 mm 5 White 17 Orange w/mark every 70 mm 6 Grey 18 Pink w/mark every 70 mm 7 Brown 19 Yellow w/mark every 35 mm 8 Violet 20 White w/mark every 35 mm 9 Turquoise 21 Grey w/mark every 35 mm 10 Black 22 Turquoise w/mark every 35 mm 11 Orange 23 Orange w/mark every 35 mm 12 Pink 24 Pink w/mark every 35 mm Strength member E- Glass rovings Sheath Black FireBur, halogen free, flame resistant thermoplastic sheathing compound acc. to EN 50290-2-27, UV stabilized Sheath marking Draka I/O DI LSHF ES9 < count> < type>< brand><item No>05<Batch Number><Meter mark> U-V(ZN) H < count> < family> <Mode field diameter> /125 <Transmission Class> Physical properties IEC 60794-1-2 Method count 2 4 6 8 12 16 24 Nominal diameter [mm] - 6 6.5 6.5 7.0 7.5 8.0 8.5 Nominal weight [kg/km] - 32 34 36 39 43 52 63 Maximum installation load (a few hours) [N] - 1500 2100 2400 Short term tensile strength (some days) [N] E1 1000 1400 1600 Permanent tensile strength [N] E1 500 1000 1500 Impact [J] E4 20 J Crush (compressive strength) E3 3000 N/ 100 mm Torsion E7 5 cycles 1 turn Minimum bending radius E11 50 75 115 Minimum bending radius under tension E18A 100 130 230 Temperature range F1 Operation and Installation Minimum bending radius of the ES9 tightly buffered fibres G01 Heat of combustion [MJ/km] [kw/m] 660 0.18 Storage With standard fibres With MaxCap-BB-OMx fibres With BendBright-XS fibers: 760 0.21 845 0.23 970 0.29 1180 0.33-20 C to 70 C -40 C to 70 C 20 mm 7.5 mm 7.5 mm 1400 0.39 1700 0.47 Page 2 of 3

Product codes ordering information Prysmian group material Prysmian Group material description code DR I/O DI N LSHF ES9 2 OM2B BL 2 MaxCap-BB-OM2 50/125 C34 60019951 DR I/O DI N LSHF ES9 4 OM2B BL 4 MaxCap-BB-OM2 50/125 C34 DR I/O DI N LSHF ES9 6 OM2B BL 6 MaxCap-BB-OM2 50/125 C34 DR I/O DI N LSHF ES9 8 OM2B BL 8 MaxCap-BB-OM2 50/125 C34 DR I/O DI N LSHF ES9 12 OM2B BL 12 MaxCap-BB-OM2 50/125 C34 DR I/O DI N LSHF ES9 24 OM2B BL 24 MaxCap-BB-OM2 50/125 C34 Draka Material code count type data sheet DR I/O DI N LSHF ES9 2 OM3B BL 2 MaxCap-BB-OM3 C31 60019530 DR I/O DI N LSHF ES9 4 OM3B BL 4 MaxCap-BB-OM3 C31 DR I/O DI N LSHF ES9 6 OM3B BL 6 MaxCap-BB-OM3 C31 60019531 DR I/O DI N LSHF ES9 8 OM3B BL 8 MaxCap-BB-OM3 C31 60019532 DR I/O DI N LSHF ES9 12 OM3B BL 12 MaxCap-BB-OM3 C31 DR I/O DI N LSHF ES9 16 OM3B BL 16 MaxCap-BB-OM3 C31 60019534 DR I/O DI N LSHF ES9 24 OM3B BL 24 MaxCap-BB-OM3 C31 60019535 DR I/O DI N LSHF ES9 4 OM4B BL 4 MaxCap-BB-OM4 C32 DR I/O DI N LSHF ES9 6 OM4B BL 6 MaxCap-BB-OM4 C32 60019536 DR I/O DI N LSHF ES9 8 OM4B BL 8 MaxCap-BB-OM4 C32 DR I/O DI N LSHF ES9 12 OM4B BL 12 MaxCap-BB-OM4 C32 60019538 DR I/O DI N LSHF ES9 16 OM4B BL 16 MaxCap-BB-OM4 C32 60019539 DR I/O DI N LSHF ES9 24 OM4B BL 24 MaxCap-BB-OM4 C32 DR I/O DI N LSHF ES9 4 MM61 BK 2 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 4 MM61 BK 4 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 6 MM61 BK 6 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 8 MM61 BK 8 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 12 MM61 BK 12 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 16 MM61 BK 16 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 24 MM61 BK 24 OM1 62.5/125 multi mode C02 DR I/O DI N LSHF ES9 2 SM2D BK 2 OS2 single mode C03e 60037923 DR I/O DI N LSHF ES9 4 SM2D BK 4 OS2 single mode C03e DR I/O DI N LSHF ES9 6 SM2D BK 6 OS2 single mode C03e 60037924 DR I/O DI N LSHF ES9 8 SM2D BK 8 OS2 single mode C03e DR I/O DI N LSHF ES9 12 SM2D BK 12 OS2 single mode C03e 60038345 DR I/O DI N LSHF ES9 16 SM2D BK 16 OS2 single mode C03e DR I/O DI N LSHF ES9 24 SM2D BK 24 OS2 single mode C03e DR I/O DI N LSHF ES9 4 SM7B BK 4 BendBrightXS G.657.A2 C24 PRYSMIAN GROUP 2012, All Rights Reserved All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group. Page 3 of 3

C31: MaxCap-BB-OM3 multimode fibre Proper rties of cabled bend insensitive OM3 fibre General and application This fibre is a laser-optimised, bend-insensitive graded-index multimode OM3 fibre suitable for transmission speeds of 10 Gb/s or higher. It has a 50 μm core diameter and a 125 μm cladding diameter. The fibree is optimised for maximum transmission properties at 850 nm; but is also well suited for 13000 nm systems. This fibre iss fully compliant to the OM3 specification. The fibre supports 1000 m link length for a 1000BASE-SX systemm and 300 m for 10GBASE-SX, as well as 550 m for a 1000BASE-LX system. The outstanding bending performance of this fibre supports future compact cable management. Standar rds IEC 60793-2-10: type A1a.2 ISO/IEC 118011 category OM3 ISO/IEC 247644 ITU G.651.1 EN 60793-2-10: type A1a. 2 EN 50173-1 category OM3 TIA/EIA-492 AAAC ANSI/TIA/EIA-568.C IEEE 802.3 Optical properties Attenuation limit according to IEC 60793-2-10, 850 nmm Attenuation limit according to IEC 60793-2-10, 1300 nm Inhomogeneity of OTDR trace for any two 1000 metre fibre lengths Numerical aperture Cable attenuation Maximum attenuation value of cable at 850 nm Maximum attenuation value of cable at 1300 nm Attenuatio on variation vs bending bending loss R=7.5 mmm 850/1300 nm bending loss R=15 mmm 850/1300 nm Bandwidth Overfilled (OFL) modal bandwidth at 850 nm Overfilled (OFL) modal bandwidth at 1300 nm Effective Modal Bandwidth (EMB) at 850 nm Group index of refraction Group index of refraction at 850 nm Group index of refraction at 1300 nm Measurement method IEC 60793-1-40 db/km IEC 60793-1-43 - IEC 60793-1-40 dbb IEC 60793-1-40 dbb IEC 60793-1-41 MHz km IEC 60793-1-41 MHz km IEC 60793-1-49 MHz km IEC 60793-1-22 - IEC 60793-1-22-2.5 0.8 Max. 0.1 0..200 ± 0.015 3.0 1.0 0.2 / 0.5 0.1 / 0.3 1500 500 2000 1..482 1..477 MaxCa ap C31_e Version 1.3 2012-07-177 Page 1 of 2

C31: MaxCap-BB-OM3 multimode fibre Geomet trical properties Core diameter Cladding diameter Cladding non-circularity Core non-circularity Core-cladding concentricity error diameter uncoloured diameter - coloured non-circularity -cladding concentricity error Mechani ical properties Proof stress level Typical average strip force Strip force (peak) Measurement method IEC 60793-1-20 μmm 50 ± 2 IEC 60793-1-20 μmm 125.0 ± 1.0 IEC 60793-1-20 % 0.7 IEC 60793-1-20 % 5 IEC 60793-1-20 μmm IEC 60793-1-21 μmm 242 ± 5 IEC 60793-1-21 μmm 250 ± 15 IEC 60793-1-21 % 5 IEC 60793-1-21 μmm 6 Measurement method 1 IEC 60793-1-30 GPa 0.7 ( 1 %) IEC 60793-1-32 N 1.7 IEC 60793-1-32 N 1.3 F peak.strip 8.9 PRYSMIAN GROUP 2012, All Rights Reserved All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced inn any form, either wholly or in part, p without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmiann Group reserves the right to amend this specification without prior notice. Thiss specification iss not contractually valid unless specifically authorised by Prysmian Group. MaxCa ap C31_e Version 1.3 2012-07-177 Page 2 of 2