CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage

Similar documents
CONTROL UNITS VEHICLE EXHAUST GASES. Pure advantages

T: +44 (0) F: +44 (0) E:

DPC300 FUME CUPBOARD CONTROLLER

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

EXHAUST EXTRACTOR Pure advantage. Exhaust rails for rescue vehicles

Single-inlet centrifugal fans

Electric Furnace KF/KFS Series

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

1 Phase electronic contactor (SC 1)

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

AUTOMATICS. GEOVENT offers a wide range of options for ventilation and extraction controls.

Motor-drive mechanism, type BUL. Technical guide

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

Type SOQ Negative Sequence Time Overcurrent Relay

TECHNICAL CATALOGUE. Softstarter range. CNABB /1SFC en, May-2000R

Emotron DCM Control Unit

Electro Controls. Damper Actuators / Valve Motors WattsIndustries.co.uk

EDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc

Smart Power is a power socket with built-in automatic for start/stop-function of fans and motor dampers in proces ventilation units.

Direction Technique et Commerciale Paris 54, Route de Sartrouville F Le Pecq Tel : (+33) ELECTRIC POWER SUPPLIER

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (2 of 2) Lecture 6 Contactors and Motor Starters

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

SECTION DC POWER SUPPLY/BATTERY CHARGER

SINGLE DUCT TERMINAL UNITS

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

KV sileo 100 M. Circular duct fans. Circular duct fans

Dimensions WxHxD [mm] Weight [kg]

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

IEC Utilization Categories (Explanation)

Instructions for the BCEA Rotary heat exchanger

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Safety Interlock Switches

RVS-AX Instruction Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Application Engineering

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Dodge Engineering & Controls, Inc. Toll Free (877) Fax: (978) EN44 and EN88 Non-Spring Return Electronic Actuators

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Pressure Transmitters

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Application Engineering

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

BAC Custom Engineered Controls

MX431 Generator Automatic Voltage Regulator Operation Manual

AA4006 Speed Sensitive Trip Unit. User Manual

DTV, DTH and VVR Roof- and wall fans DTV Roof fan DTH Roof fan VVR Wall fan

SN1010 NATURAL VENTILATION CONTROLLER SET POINT

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Sky Wing. Contents. Power Roof Ventilator

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Swing Gate Kits AUTOMATIC GATE KITS & ACCESSORIES SECURING GATES SINCE Control Cards. Accessories 2017 / Gate & Door Controls Catalogue

H:\SC218\17_Ersatzteile\Spare Parts SC 218.doc

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

Product manual Extraction arm KUA

Automatic COSYS PFC. Automatic power factor correction system NEW

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

Essential equipment for all your requirements

INSTRUCTION MANUAL MAGNA RAIL

Components for EEx e Panels

MAGNETIC MOTOR STARTERS

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

MCset kv Medium voltage equipment

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

AXICIAT VA. Axial fans. Smoke extraction F200/120 and F400/120. High available pressure

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

V-SENSOR LOW AIR VELOCITY SENSOR

1.1 Caution Statements

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

SECTION MOTOR CONTROL

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

Thermal Circuit Breaker 3120-F...

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Installation instruction MicaFlex fume hood control. Fume hood control. Innehållsförteckning. Mi-212gb_

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

MaxPak Plus Analog DC V S Drive

Oil - kerosene burner

AHN 064 to 304 EHN/CHN 064 to 304

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

SDS Enclosed Star-Delta Starter User Guide

Softstarters Type PSS. Softstarters. General information

GMX24-SR. Proportional Control, Non-Spring Return, Direct Coupled, 24V, for 2 to 10 VDC and 4 to 20 ma

RVP-R- VAV controller. In explosion-proof version

Industrial Variable Speed A-C Motors B-4511

SmartX MF and MS

Transcription:

CONTROL UNITS LOCAL EXTRACTORS Fumex s control unit offers a good working environment, adapted to all types of facilities. The right choice of control units is also very energy-saving and provides the lowest possible noise levels. Control automation encompasses specially adapted and proven components, as well as recommendations for appropriate system selections. In the installation examples on pages 2 through 5, there are suggestions for various solutions to help finding systems to satisfy most needs. Local extraction arms are presented in various system solutions in the examples. Automation can even be used in other applications, such as when connecting extractors directly to machinery. For control of automotive exhaust installations, see the control automation for exhaust extraction. Most types of sensors such as for gas, heat, light and vibrations can be combined with the S 200 and S control units. For help with optimising extractor installations or calculating energy savings, please contact Fumex. Fumex also offers a range of local extractors, fans, accessories and filters to our local extractors. LOCAL EXTRACTORS Pure advantage

Start and stop of fans, with or without speed control. System 1:1 Manual start and stop of fan The fan is manually started and stopped with a protective motor switch SMB. The protective motor switch has a thermal-magnetic release and phase failure protection. SMB Protective motor switch 1x VAC/ 3x VAC System 1:2 Manual speed control of fan that is started and stopped with the potentiometer. The fan s speed is regulated manually and start/stopped as necessary with the SFC PS potentiometer. SFC PS Potentiometer SFC Frequency converter 1x VAC/ 3x VAC System 1:3 Manual start and stop of fan and two speeds The fan is manually started and stopped with the SFC VSS rotary switch. With the rotary switch, the fan speed can be regulated between two preset speeds that are programmed on the frequency converter display. SFC VSS Rotary switch SFC Frequency converter 1x VAC/ 3x VAC System 1:4 Manual start and stop of fan and need-adapted control of fan speed The fan is manually started and stopped with the SFC SB switch. The frequency converter maintains a constant negative pressure in the main duct via the pressure sensor. ST 300 Pressure sensor SFC SB Switch SFC Frequency converter 1x VAC/ 3x VAC 1x/ 3x VAC Signal cable Hose

Start and stop fans with contactor. Manual control from work station with time delay System 2:2 Manual start and stop of fan. Start and stop is made manually with a push-button mounted on the extractor. The S control unit has a builtin adjustable time delay of 0-15 minutes. Contactor Transformer S Control unit S Control unit 1x VAC/ 3x VAC 1x VAC PRT / KHT Push-button PRT / KHT Push-button Automatic control from work station with time delay. System 2:3 Automatic starting and stopping of fan. Starting and stopping are conducted automatically with the STG pliers sensor, which is clipped onto the earth cable of the welding transformer. The S control unit has a built-in adjustable time delay of 0 15 minutes. Contactor Transformer S Control unit S Control unit 1x VAC/ 3x VAC 1x VAC STG Pliers sensor STG Pliers sensor 1x/ 3x VAC 24 VAC Signal cable

Individual damper control and start and stopping of fan via contactor Damper and contactor manually controlled from the work station with time delay System 3:2 Manual control of damper and start and stop of fan Opening and closing of the damper is made manually via a push-button mounted on the extractor. A control signal from the control unit starts and stops the fan. Transformer S Control unit S Control unit The S control unit has a built-in adjustable time delay of 0 15 minutes. 1x VAC/ 3x VAC Contactor 1x VAC PRT / KHT Push-button PRT / KHT Push-button Damper and contactor automatically controlled from the work station with time delay System 3:3 Automatic control of damper and start and stop of fan The damper opened and closed automatically with the STG pliers sensor, which is clipped onto the earth cable of the welding transformer. Transformer S Control unit S Control unit A control signal from the control unit starts and stops the fan. Contactor The S control unit has a builtin adjustable time delay of 0 15 minutes. 1x VAC/ 3x VAC 1x VAC STG Pliers sensor STG Pliers sensor 1x/ 3x VAC 24 VAC Signal cable

Individual damper control and need-adapted control of fan via a pressure sensor and frequency converter Damper and frequency converter manually controlled from the work station with time delay System 4:2 Manual control of damper and needadapted control and start and stop of fan The damper is opened and closed manually with a push-button mounted on the extractor, which also starts and stops the fan. Transformer S Control unit S Control unit The frequency converter maintains a constant negative pressure in the main duct via the pressure sensor. The S control unit has a built-in adjustable time delay of 0 15 minutes. ST 300 Pressure sensor 1x VAC/ 3x VAC SFC Frequency converter 1x VAC PRT / KHT Push-button PRT / KHT Push-button Damper and frequency converter automatically controlled from the work station with time delay System 4:3 Automatic control of damper and needadapted control and start and stop of fan The damper is opened and closed automatically with the STG pliers sensor, which is clipped onto the earth cable of the welding transformer. A control signal from the control unit starts and stops the fan. The frequency converter maintains a constant negative pressure in the main duct via the pressure sensor. The S control unit has a built-in adjustable time delay of 0 15 minutes. 1x VAC/ 3x VAC Transformer ST 300 SFC Pressure sensor Frequency converter 1x VAC S Control unit STG Pliers sensor S Control unit STG Pliers sensor 1x/ 3x VAC 24 VAC Signal cable Hose

SFC ENCLOSURE CLASS IP 21 Designation SFC 037/21-1 SFC 037/21-3 SFC 055/21-1 SFC 055/21-3 SFC 075/21-1 SFC 075/21-3 SFC 110/21-1 SFC 110/21-3 SFC /21-1 SFC /21-3 SFC 220/21-1 SFC 220/21-3 Rated power kw 0,37 0,37 0,55 0,55 0,75 0,75 1,1 1,1 2,2 2,2 ENCLOSURE CLASS IP 55 Rated current A 3,3 3,7 1,9 4,8 2,3 6,9 3 8 4,1 11 5,5 Output V 1- phase 3-phase FREQUENCY CONVERTER Designed for process ventilation The SFC frequency converter is designed for variable speed control of e.g. fans. This provides optimal operating economy and the lowest possible noise level. Depending on the number of work stations in operation, the SFC (along with the ST 300 pressure sensor) varies the fan speed and thus evacuates the correct amount of air. Alternatively, manual variable control can be used with the SFC PS potentiometer. The SFC VSS is used if a 2-step control is preferred. Interference filters are included. The enclosure class is IP 21 for built-in applications, alternatively IP 55 for dust- and water protection. Fumex can supply SFC PROG pre-programmed frequency converters to make it easier to put systems in operation. For alternative voltages, etc., please contact Fumex. Input V Weight kg 3,1 3,1 Width mm 72 72 72 140 140 Height mm SFC /21-3 4 9,5 3,1 140 184 SFC 750/21-3 7,5 17 6,5 180 232 170 Designation SFC 037/55-1 SFC 037/55-3 SFC 055/55-1 SFC 055/55-3 SFC 075/55-1 SFC 075/55-3 SFC 110/55-1 SFC 110/55-3 SFC /55-1 SFC /55-3 SFC 220/55-1 SFC 220/55-3 Rated power kw 0,37 0,37 0,55 0,55 0,75 0,75 1,1 1,1 2,2 2,2 Rated current A 3,3 3,7 1,9 4,8 2,3 6,9 3 8 4,1 11 5,5 Output V 1- phase 3-phase Input V Weight kg 6,3 8,8 6,3 8,8 6,3 8,8 8,8 8,8 8,8 10,7 10,7 Width mm 210 210 210 145 145 145 184 184 Height mm SFC /55-3 4 9,5 10,7 340 208 SFC 750/55-3 7,5 17 23,6 320 425 290 240 240 240 340 340 Depth mm 130 140 140 Depth mm 163 163 163 208 208

SFC PS/VSS/SB SFC POT POTENTIOMETER The SFC PS is a potentiometer for a variable regulation of fan speed via frequency converters. Dimensions Resistance 100x100x67 mm 10 kω SFC VSS ROTARY SWITCH The SFC POT is a rotary switch for 2-step regulation of fan speeds via frequency converters. SFC PS Dimensions 100x100x67 mm Increments 0-1-2 SFC SB SWITCH The SFC SB is a switch for start/stop of fans via frequency converters. SFC VSS Dimensions 60x80x55 mm Enclosure class IP 54 Power supply Max 250 V, 16 A SFC SB ST 300 ST 300 PRESSURE SENSOR The ST 300 maintains constant negative pressure in the discharge duct via a frequency converter that controls fan speeds. The ST 300 always provides the correct flow, regardless of the number of open and closed dampers. Dimensions 90x96x36 mm Enclosure class IP 54 Operating range 500, 1000, 2000, 3000 Pa Power supply 24 VDC Output signal 0-10 V (alt. 4-20 ma) Inc. accessories Measurement output and 2 m hose

S S CONTROL UNIT The S is used for automatic control of damper motor SAS 24 at terminals 1 4. Fans are normally controlled via the transformer units. The after-run time for evacuation of remaining gases is built into the control unit. The time is set between 0 15 min. The S is supplied with 24 VAC from the transformer unit. STG Dimensions 130x80x77 mm Enclosure class IP 54 Primary side 24 VAC Secondary side 24 VAC SMT 60 TIMER SWITCH The SMT mechanical timer switch is a manual timer, adjustable from 0 to 60 minutes. It can replace a KHT push-button unit. The SMT 60 is wall-mounted close to the extractor. Dimensions Timeset 100x100x67 mm 0-60 min. ACCESSORIES SSB STG KHT / MEMT PRT Switch Clip-on sensor Push-button unit Push-button unit SMT 60 MEMT-XXX SSB PRT S Terminals 1-4 24 V~ For damper 5-7 Potential-free VX-switch. 8-9 24 V~ supply from. 10-14 Connection sensor (15 V). SMT 60. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 STG SAS KHT / MEMT-XXX PRT

TRANSFORMER UNIT The is used to supply 24 VAC to the S control unit. Control of fan is made via external contactor VAC, via signal from terminals 1 & 2. Frequency converter is controlled via the potential-free outputs, terminals 3 and 4. Dimensions 130x180x102 mm Enclosure class IP 54 Primary side VAC Secondary side 24 VAC (60 VA) Terminals L1-N V~ Main connection. 1-2 V~ Connection. 3-4 Potential-free VX-switch. 5-6 24 V~ Votage. 7-8 Switch connection. L1 PE N 1 2 3 4 5 6 7 8 S SFC

S 200/ S 200/24 S 200/ CONTROL UNIT S 200/24 CONTROL UNIT The S 200/ is used for automatic control of damper motor SAS and/or a fan. The after-run time for evacuation of remaining gases is built into the pliers sensor (~30 sec.). For longer after-run times, there is an adjustable timer card (0 15 min. and 0 240 min.) available as an accessory. Single-phase fans (max. 0.75 kw) can be directly controlled via an integrated relay. Other fans are controlled with an external contactor via the same integrated relay, terminals 1 5. Frequency converters are controlled via the potential-free output, terminals 6 8. Dimensions 180x130x77 mm Enclosure class IP 54 Primary side VAC Secondary side VAC (Max 10A) ACCESSORIES STK 15 Timer card 0-15 min STK 240 Timer card 0-240 min SSB Switch STG 200 Pliers sensor (~30s delay) KHT/PRT Push-button unit The S 200/24 is used for automatic control of damper motor SAS 24 and/or a fan. The after-run time for evacuation of remaining gases is built into the pliers sensor (~30 sec.). For longer after-run times, there is an adjustable timer card (0 15 min. and 0 240 min.) available as an accessory. Fans are controlled with external contactors via the integrated relay, terminals 1 5. Frequency converters are controlled via the potential-free output, terminals 6 8. Dimensions 180x130x77 mm Enclosure class IP 54 Primary side VAC Secondary side 24 VAC ACCESSORIES STK 15 Timer card 0-15 min STK 240 Timer card 0-240 min SSB Switch STG 200 Pliers sensor (~30s delay) KHT/PRT Push-button unit STG 200 S 200/ S 200/24 STG 200 STK 15 SSB STK 240 KHT PRT S 200/ S 200/24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 SAS SAS STG 200 STG 200 PRT PRT Terminals PRT/ KHT /MEMT-XXX 1-5 V~ For 1-phase fan motor (Max 0,75kW.) 1-5 V~ For contactor -xxx/. 1-5 V~ For damper SAS-xxx/. 6-8 Potential-free VX switch. 9-11 V~ Main connection. 12-14 Connection sensor (15 V). Terminals 1-5 24 V~ For damper. 6-8 Potential-free VX-switch. 9-11 V~ Main connection. 12-14 Connection sensor (15 V). PRT/ KHT /MEMT-XXX..

SMB SMB PROTECTIVE MOTOR SWITCH The SMB is a 3-pole protective motor switch with thermal-magnetic release and equipped with phase failure protection. The SMB is designed for control and protection of fan motors. Dimensions 93x148x84 mm Enclosure class IP 55 Product Current 3-phase range ~ V (A) (kw) SMB 10* 0,63-1,0 0,25 SMB 16* 1,0-1,6 0,37/0,55 SMB 25* 1,6-2,5 0,75 SMB 40* 2,5-4,0 1,1/ SMB 63* 4,0-6,3 2,2 SMB 100* 6,0-10,0 4,0 SMB 140** 9,0-14,0 5,5 SMB 180** 13,0-18,0 7,5 * Self-protecting, pre-fusing not required ** Max. pre-fusing when Ik>Icu is 63 A. CONTACTOR The is a 3-pole contactor with an overcurrent relay for manual resetting. The overcurrent relay has phase failure protection. It is used with external switches or control. Dimensions 103x200x153 mm Enclosure class IP 55 Product Current 3-phase range ~ V (A) (kw) 10/* 0,63-1,0 0,25 17/* 1,0-1,7 0,37/0,55 25/* 1,6-2,5 0,75 40/* 2,5-4,0 1,1/ 60/* 4,0-6,0 2,2 80/* 5,5-8,0 4,0 130/** 9,0-13,0 5,5 180/** 12,0-18,0 7,5 * Maximum power is 4 kw. **Maximum power is 7.5 kw.

SAS 20180312 ~24 V SAS AUTOMATIC DAMPER The SAS is an automatic single-leaf damper for applications where short operating times are necessary. The extremely fast motor opens the damper blade in 7.5 seconds. This entails 95% extraction capacity after 3 seconds. The damper is supplied for air tightness class 1. For other air tightness classes, please contact Fumex. Dimensions (motor) 140x100x85 mm Material (cowling) PA Material (damper housing) Galvanised sheet metal Opening time, 90º 7,5 s Torque 3 Nm Power consumption (24 V) 2 VA i drift/ 0 VA i vila Power consumption ( V)5 VA i drift/ 0 VA i vila Product Diameter Voltage (mm) (V) SAS-100/24 Ø100 24 SAS-125/24 Ø125 24 SAS-160/24 Ø160 24 SAS-200/24 Ø200 24 SAS-250/24 Ø250 24 SAS-315/24 Ø315 24 ~ V SAS-100/ Ø100 SAS-125/ Ø125 SAS-160/ Ø160 SAS-200/ Ø200 SAS-250/ Ø250 SAS-315/ Ø315 Verkstadsvagen 2, SE-931 61 SKELLEFTEÅ, Sweden Tel. +46 910-361 80, Fax +46 910-13022 www.fumex.com info@fumex.se Fumex AB, 2016 With provision for changes