MR16out Processor Installation and Specifications

Similar documents
SPC Series. Digital Scale. Operation Manual

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

American Power Design, Inc.

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

AUTO PUMP STATUS CENTER

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

INSTALLATION/OPERATING INSTRUCTIONS TSC

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

All products subject to this warranty must be returned for examination, repair or replacement to:

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

American Power Design, Inc.

C3000 SIGNAL TRANSMITTER. Introduction

CUL INVERTER/CHARGER OWNER'S MANUAL

Industry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

TD77-2 and ULB42-TD-2 TRAFFIC DIRECTOR CONTROL BOXES

SCP Hardware Quick Reference

Vehicle Application Guide... Wiring Diagram... Wiring Connection Reference Chart... LED Diagnostics and Troubleshooting... Reset the module...

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Remote Vehicle Control System. Keyless Entry and Convenience System

Generator Start Control Module

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Installation Manual Model 3800/3810

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

A419ABG-3C Electronic Temperature Control

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Phase Sequence Tester

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

OC Automation Converters Series. Electronic Industries Alliance (EIA) interface converter series for serial communication devices

INTECH Micro 2300-RTD6

Two Channel Remote Shutdown Device

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

Installation Guide. Index. Vehicle Canbus Integration System

TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER. INSTRUCTION NUMBER: AO of 9

Door lock and key interface compatible with the latest Kia vehicles. The available features include brake, hood, trunk and door trigger sensors.

MARS Way Controller OPERATING & INSTALLATION INSTRUCTIONS LIMITED LIFETIME WARRANTY

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

BSC Series

Infinitybox Express Road Race Car Kit Installation Guide

Installation and Operation Guide

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

L I M I T E D L I F E T I M E W A R R A N T Y

Generator Start Control Module

RU BMS Power Supply and Battery Management System Owners Guide

Installation and Operation Guide

Solar Charge Controller Owner s Manual SC 1210 SC 1210LD SC 1220LD

Panel Mount Digital Tachometer Model

User Guide. Model Insulation Tester / Megohmmeter. Introduction

MDC Series

ca1153 Owner s Guide

Owner s Guide. ca5154

Lingenfelter ECSS-001 Ethanol Content Sensor Signal Simulator Installation & Operating Instructions

BroadBand PowerShield. 20 AHr Battery. User Manual

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

Speedometer Interface

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

Sola/Hevi-Duty S3K Series Mini-Tower UPS

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

60 Series Engine Controls

Warranty Compatibility vehicle chart Bootloading CANMAX Installation (overview) Installation TYPE A...

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

Full Function Display User s Manual

Electronic Ballast EVG 2000-T

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Digital/Analog Amplifiers Installation Instructions

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

INSTALLATION/OPERATING INSTRUCTIONS MCP

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

Remote Vehicle Control System CA-150. Owner's Manual. Vehicle Security System With Remote Keyless Entry

Setup and Configuration Guide Universal Switch Interface

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Expansion Signal (XSIG) Card Installation Instructions

Omega RS-110-DP OPERATION MANUAL BACK COVER PRINTER S NOTE: production back cover. is color; this is a place marker cover. FRONT COVER PRINTER S NOTE:

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

MOTORTRONICS Solid State AC Motor Control

Emergency Response Trailer 14

Installation and Operating Manual

Owner s Guide ca4054 ca4554

MDCSL V, 30A

CA 5054 Owner s Guide

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Installation and Operating Manual

Remote Vehicle Control System. Keyless Entry & Remote Start System

Web Volume Control Model WV220

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

WARRANTY INFORMATION...

Owner s Guide CA 4555

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Transcription:

MR16out Processor Installation and Specifications 1. General: www.mercury-security.com 2355 MIRA MAR AVE., LONG BEAH, A 90815-1755, (562) 986-9105 FAX (562) 986-9205 This device complies with part 15 of the F Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The MR16out processor provides a solution to the OEM system integrator for output control. The controller has 16 form- contact relays for load switching. Additionally, 2 digital inputs are provided for tamper and power fault status monitoring. The processor requires 12 to 24Vdc for power. 1 2 4 7 9 3 5 12 6 8 13 14 10 11 15 16 N K1 K9 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 N N N N N K7 TB3 TB2 TB1 K2 K4 K6 K3 K5 K11 K12 K13 K14 K10 TB5 TB6 TB7 OUT 6 N OUT 7 N OUT 8 N T TB9 2W 4W RS-485 TR+ TR- R+ R- TB10 S1 1 2 3 4 5 6 7 8 VIN TB11 OUT 9 N OUT 10 N OUT 11 N OUT 12 N OUT 13 N K15 OUT 14 N TB4 K8 K16 TB8 OUT 115 N OUT 16 J6 A J5 B J7 T J2 J1 J1, J2 RS-485 TERM J3 2W 4W U1 J8 J4 2. Supplying Power to the MR16out: The MR16out accepts 12 to 24Vdc for power. Locate power source as closed to the unit as possible. onnect power with minimum of 18AWG wires. Observe POLARITY on VIN! + VIN 12 TO 24Vdc - TB11 Mercury Security orporation, opyright 2006 MR16out DO 10107-0011 REV: 2.00 Page 1

3. ommunication Wiring: The MR16out communicates to host via a RS-485 interface, which may be configured for either 2-wire or 4- wire operation. The interface allows multi-drop communication on a single bus of up to 4,000 feet (1,200 m). Use twisted pair(s) (minimum 24 AWG) with shield for the communication. Install the following jumpers for the RS-485 interface according to the selected configuration: 2W 4W TR+ TR- R+ R- TB10 2-WIRE (ONLY 2-WIRE RS-485 IS SUPPORTED) 4. Inputs for abinet Tamper/Power Fault: Input T and input are used for monitoring cabinet tamper and power failure with normally closed contacts. These two inputs are for contact closure monitoring only, and do not use EOL resistor(s). If these inputs are not used, install a short piece of wire at the input to indicated safe condition. ABINET TAMPER POWER FAULT T TB9 5. Relay Outputs: The following diagram shows a typical use of the relay. A D power source is recommended whenever possible. Transient clamping must be provided to protect the contacts and to reduce EMI emission. Use sufficiently large wires for the load current to avoid voltage loss. TB5 N N FUSE LOAD FUSE MOV LOAD + D SOURE - A SOURE DIODE SELETION: DIODE URRENT RATING > 1 X STRIKE URRENT DIODE BREAK DOWN VOLTAGE: 4X STRIKE VOLTAGE FOR 12Vdc or 24Vdc STRIKE, DIODE 1N4002 (100V /1A) TYPIAL MOV SELETION: LAMP VOLTAGE > 1.5 X Vac RMS FOR 24Vac STRIKE, PANASONI ERZ-07DK470 TYPIAL Mercury Security orporation, opyright 2006 MR16out DO 10107-0011 REV: 2.00 Page 2

6. DIP Switch and Jumper Usage: Switches 1 to 5 select the devices communication address. Switches 6 to 7 select the communication baud rate. ommunication on the RS-485 serial port is asynchronous, half-duplex with 1 start bit, 8 data bits and 1 stop bit. S8 S7 S6 S5 S4 S3 S2 S1 SELETION OFF OFF OFF OFF OFF Address 0 OFF OFF OFF OFF ON Address 1 OFF OFF OFF ON OFF Address 2 OFF OFF OFF ON ON Address 3 OFF OFF ON OFF OFF Address 4 OFF OFF ON OFF ON Address 5 OFF OFF ON ON OFF Address 6 OFF OFF ON ON ON Address 7 OFF ON OFF OFF OFF Address 8 OFF ON OFF OFF ON Address 9 OFF ON OFF ON OFF Address 10 OFF ON OFF ON ON Address 11 OFF ON ON OFF OFF Address 12 OFF ON ON OFF ON Address 13 OFF ON ON ON OFF Address 14 OFF ON ON ON ON Address 15 ON OFF OFF OFF OFF Address 16 ON OFF OFF OFF ON Address 17 ON OFF OFF ON OFF Address 18 ON OFF OFF ON ON Address 19 ON OFF ON OFF OFF Address 20 ON OFF ON OFF ON Address 21 ON OFF ON ON OFF Address 22 ON OFF ON ON ON Address 23 ON ON OFF OFF OFF Address 24 ON ON OFF OFF ON Address 25 ON ON OFF ON OFF Address 26 ON ON OFF ON ON Address 27 ON ON ON OFF OFF Address 28 ON ON ON OFF ON Address 29 ON ON ON ON OFF Address 30 ON ON ON ON ON Address 31 OFF OFF 2,400 BPS OFF ON 9,600 BPS ON OFF 19,200 BPS ON ON 38,400 BPS OFF Not Used JUMPER J1 J2 J3 J4 J5 J6 J7 J8 DESRIPTION RS-485 TERMINATION, INSTALL IN FIRST AND LAST UNITS ONLY FATORY USE ONLY 2-WIRE/4-WIRE SELET, INSTALL IN 2W POSITION ONLY FATORY USE ONLY FATORY USE ONLY FATORY USE ONLY FATORY USE ONLY FATORY USE ONLY Mercury Security orporation, opyright 2006 MR16out DO 10107-0011 REV: 2.00 Page 3

7. Status LEDs: Power-up: All LED s OFF. Initialization: Once power is applied, initialization of the module begins. The A LED is turned on at the beginning of initialization. If the application program cannot be run, the A LED will flash at a rapid rate. The MR16out is waiting for firmware to be down loaded. When initialization is completed, LEDs A, B, T and are briefly sequenced ON then OFF. Run time: After the above sequence, the LEDs have the following meanings: A LED: Heartbeat and On-Line Status: Off-line: 1 second rate, 20% ON On-line: 1 second rate, 80% ON B LED: SIO ommunication Port Status: Indicates communication activity on the SIO communication port T: abinet Tamper : Power Fault Input in the inactive state: OFF (briefly flashes ON every 3 seconds) Input in the active state: ON (briefly flashes OFF every 3 seconds) LED 1 through 16: Illuminates when output relay OUT 1 (K1) through OUT 16 (K16) is energized. 8. Specifications: The MR16out is for use in low voltage, class 2 circuits only. Primary power: Relay contacts: Inputs: ommunication: 12 to 24Vdc ±10%, 1100mA maximum 12Vdc @ 850mA nominal 24Vdc @ 450mA nominal 16 Form-, 5A @ 28Vdc, resistive 2 unsupervised, decicated for cabinet tamper and UPS fault monitoring RS-485, 2-wire. 2400, 9600, 19200 or 38400bps able requirements: Power: RS-485: Inputs: Outputs: Mechanical: Dimension: Weight: Environmental: Temperature: Humidity: 1 twisted pair, 18 AWG 24AWG, 120 ohm impedance, twisted pair with shield, 4,000' (1,200m) maximum 1 twisted pair, 30 ohms maximum As required for the load 6" (152mm)W x 8" (203mm)L x 1" (25.4mm)H 14 oz. ( 400 gm) nominal -55 to +85, storage 0, to +70, operating 0% to 95% RHN Mercury Security orporation, opyright 2006 MR16out DO 10107-0011 REV: 2.00 Page 4

Warranty Mercury Security orporation warrants the product is free from defects in material and workmanship under normal use and service with proper maintenance for one year from the date of factory shipment. Mercury Security orporation assumes no responsibility for products damaged by improper handling or installation. This warranty is limited to the repair or replacement of the defective unit. There are no expressed warranties other than set forth herein. Mercury Security orporation does not make, nor intends, nor does it authorize any agent or representative to make any other warranties, or implied warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose. Returned units are repaired or replaced from a stock of reconditioned units. Returns must be accompanied by a return authorization number (RMA) obtained from customer service, and prepaid postage and insurance. Liability The Interface should only be used to control exits from areas where an alternative method for exit is available. This product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security orporation is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or malfunction of the product. Mercury Security orporation's liability does not extend beyond the purchase price of the product. Mercury Security orporation, opyright 2006 MR16out DO 10107-0011 REV: 2.00 Page 5