GD series Submersible Grinder Pump

Similar documents
Thank you for selecting the GD submersible grinder pump.

Installation, Operation and Maintenance Manual Stancor SE, SV, SS & SC Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

barmesapumps.com 2AHS 0.5 & RPM Installation, Operation & Maintenance Manual Submersible Dewatering Pumps

Installation & Operating Manual

barmesapumps.com 2AHS 0.5, 1 & RPM Installation, Operation & Maintenance Manual Submersible Dewatering Pumps

Submersible Sump/Drainage Pump

GeyserMax-Flow Series

Instruction Manual. * We reserve the right to amend specification without prior notice.

PL Submersible, Semi-Vortex, Water Feature Pump

Instruction Manual. * We reserve the right to amend specification without prior notice.

EBARA Fluid Handling

Matala. VersiFlow Series. Instruction and Maintenance Manual

SUBMERSIBLE PUMP HSE RANGE

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

Submersible Stainless Steel Semi-Vortex Pumps Pumps

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

SUBMERSIBLE PUMP HSE RANGE

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

SUBMERSIBLE SUMP PUMP RANGE

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz

DUMPER. Data Book 50 Hz

SPECIFICATION PUMP. DW - G 2 UNI ISO 228 Flange

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 BEARINGS 301 MECHANICAL SEAL 301

SUBMERSIBLE SEWAGE PUMPS WITH SEMI-VORTEX IMPELLER in cast iron

KTV/NK Series. Submersible General Dewatering Pump OPERATION MANUAL

A Series. 60 Hz. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CHART DW 204 PERFORMANCE CHART DW VOX 205

Submersible Stainless-Steel Cutter Pump OPERATION MANUAL

Technical Data BEST 2~5. Stainless Steel Submersible Sump Pumps EBARA PUMPS AUSTRALIA PTY. LTD. Best 2-5_Techdata_SS_V10

Technical Data DML. Submersible Sewage Pumps with Single Channel Impeller. DML_Techdata_SS_V11 EBARA PUMPS AUSTRALIA PTY. LTD.

TSURUMI MANUFACTURING CO., LTD.

Sewage transport Submersible pumps

Series description: Wilo-Drain MTC

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

WASTEWATER SUBMERSIBLE MOTOR PUMP MODEL DML3

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

A Series 50HZ. A - Series. Vertical Multistage Centrifugal in-line Pumps AVC/AVI/AVS ISO-9001

Multi-stage Immersion Type

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

Fully Imported from Japan

Series description: Wilo-Drain STS 40

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 TYPE KEY 202 PERFORMANCE CHART DW 203 PERFORMANCE CHART DW VOX 204

VERSION 1 VU4. KAWAMOTO SUBMERSIBLE PUMP 4 POLES / 50 Hz SIZE MM. 100 % SOLID PASSAGE MODEL VORTEX IMPELLER KAWAMOTO PUMP ASIA CO.,LTD.

Submersible Vortex Sewage Pump

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Submersible Pump Instructions. Safety Instructions

Operating Manual Includes Pumps: PG-9000 Part #R809606

Ebara Submersible Sewage Pumps (Single Channel Impeller)

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE RIGHT PERFORMANCE CURVE RIGHT

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

- click here for pricing and ordering

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

SUBMERSIBLE WATER PUMPS

Ni-HARD SUBMERSIBLE PUMP

Page - SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART BEST ONE 202 PERFORMANCE CHART BEST ONE VOX 203

Electric submersible pumps SEMISOM for sewage water

SUBMERSIBLE PUMP RANGE

- CONTENTS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

INSTALLATION AND OPERATING INSTRUCTIONS

Battery Powered Hydraulic Pump; Kit PN [ ]

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

OPERATION MANUAL TSURUMI MANUFACTURING CO., LTD.

SUBMERSIBLE SEMI-VORTEX SEWAGE PUMPS

DEWATERING PUMP. Instruction, Installation, Operation and Maintenance Manual. A Mark of Quality. ISO 9001 Certified Company

Portable Oil Free Silent Series Compressor Operating Instructions

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Dewatering Submersible sewage pumps

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Owners Manual: - Pumps

PROCESS PUMPS (INDIA) PVT LTD

200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS 202 PERFORMANCE CURVES DW VOX 204

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Multi-stage Immersion Type VKB Series

SUBMERSIBLE DIRTY WATER PUMP

SUNC3000 / Item #40885

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

Submersible Pumps. 5'' CS Series Pumps

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

OPERATION & MAINTENANCE INSTRUCTIONS

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

SUBMERSIBLE PUMPS EFFLUENT DISPOSAL RANGE 4 poles - 50 Hz

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

OPERATION & MAINTENANCE MANUAL PORTABLE SUBMERSIBLE PUMP

3-Way Ball Valve Type 23H

Semi-vortex Submersible Pump SVC. 50Hz

SUBMERSIBLE ELECTRIC PUMPS FOR DRAINAGE AND WASTEWATER 50 Hz

Transcription:

GD series Submersible Grinder Pump 60HZ STAIRS INDUSTRIAL CO., LTD.

GD series-submersible Grinder Pump Model code GD - 15-30 - M A A = AUTO M = Single Phase T = Three Phase Connection dimensions Output power x 10 Series name Feature Robust construction Superior Heat Dissipation Vortex impeller design prevents clogging by cutting up articles Radial cutter and cutter ring SUS440C : corrosion resistant material, hardened to 55-60 Rockwell C Specific single phase design for starting torque, torque is five times stronger than General capacitor pump Horizontal casing with female thread can be fit the pipe directly Double mechanical seals Upper:CA/CE/NBR Lower:SIC/SIC/NBR Application Performance Curves Waste water treatment Sewage water Drainage of wastewater from individual residences,apartment buildings,recreational developments,motels Transferring wastewater,schools,federal,state and local parks To transfer various wastewater and sewage Motor H [m] 60 50 40 30 20 GD-50-50T GD-30-30T GD-20-30M(MA)(T) GD-75-50T Motor Type: 2 POLE, dry type Frequency: 60Hz Insulation Class: E class (120 C) Nominal Speed: 3450 rpm Pump Enclosure Protection Class: IP 68 Protector: Thermal protection Insulation Class: E class (120 C) Bearing: Ball Type Mechanical seal: Dual. Mechanical Seal 10 GD-15-30M(MA)(T) 0 100 200 300 0 6 12 18 Operation Conditions Liquid Temperature: 0 C - 40 C (32-104 F) MAX.depth: 10M Q[L/min] Q[m³/ h] Cutter HRC55~60 Semi-open Impeller 71 79 17 79a 43 11 7 2 4 3 31 32 19 10 15 7a No. 2 3 4 7 7a 10 11 15 17 19 31 32 43 71 79 79a Component Handle Bracket Upper Cover Cutter Cutter Ring Pump Casing Seal Housing Impeller Motor Housing Oil Chamber Stator Shaft and Rotor Mech. Seal Capacitor Upper Bearing Lower Bearing 1.5HP/2HP/3HP SS 41 SUS 440C SUS 440C SUS 410 Upper:CA/CE/NBR Lower:SIC/SIC/NBR - 6203 6304 Material 5HP/7.5HP SS 41 SUS 440C SUS 440C SUS 410 Upper:CA/CE/NBR Lower:SIC/SIC/NBR - 6304 6305-1 - www.stairs.com.tw

Dimension H2 H H1 D F C B E A K3 K2 K4 H2 K1 H1 K H D F C B E A K3 K2 K4 K1 K G G GD-15/20/30 GD-15/20/30 with QG Guide Rail System GD-50/75 GD-50/75 with QG Guide Rail System Model Dimensions (mm) A B C D E F G H H1 H2 K K1 K2 K3 K4 GD-15-30 128 102 103 103 230 206 445 640 445 160 630 432 150 50 240 GD-20-30 128 102 103 103 230 206 445 640 445 160 630 432 150 50 240 GD-30-30 128 102 103 103 230 206 445 680 485 160 670 472 150 50 240 GD-50-50 164 119 125 114 283 239 500 669 509 186 637 477 154 29 240 GD-75-50 164 119 125 114 283 239 500 709 549 186 677 517 154 29 240 Specifications Model Phase Voltage (V) Power Head (Pressure) Flow (Capacity) Connection Cable Weight HP KW Rated (M) Max. (M) Rated(L/min) Max. (L/min) Outlet M kg GD -15-30M 230 1.5 1.1 15.5 21.5 90 160 1-1/4" 10 30 GD -15-30MA 230 1.5 1.1 15.5 21.5 90 160 1-1/4" 10 30.5 1ø GD -20-30M 230 2 1.5 22 30 115 160 1-1/4" 10 32.8 GD -20-30MA 230 2 1.5 22 30 115 160 1-1/4" 10 33.3 GD -15-30T 460 1.5 1.1 15.5 21.5 90 160 1-1/4" 10 30 GD -20-30T 460 2 1.5 22 30 115 160 1-1/4" 10 32.8 GD -30-30T 3ø 460 3 2.2 24 32 130 160 1-1/4" 10 35 GD -50-50T 460 5 3.7 26 37 240 300 2" 10 44 GD -75-50T 460 7.5 5.5 35 49 250 300 2" 10 49 Model with M is single. Model with T is three. Model with A is AUTO. - 2 - www.stairs.com.tw

www.stairs.com.tw 201701 Subject to alterations

GD

INDEX Introduction..PAGE. 2 Nameplate format...page. 2 Prior to Operation...PAGE. 3 Installation....PAGE. 3 Electrical Wiring...PAGE. 4 Operation. PAGE. 5 Maintenance...PAGE. 5 Construction PAGE. 6 Troubleshooting.. PAGE. 10 Disassembly and Assembly..PAGE. 11 Introduction Thank you for selecting the GD submersible grinder pump. This instruction manual explains the product operations and gives important precautions regarding its safe use. In order to use the product to maximum benefit, be sure to read the instructions thoroughly and follow them carefully. To avoid accident, do not use the pump in any way other than as described in this instruction manual especial on! WARNING.. After reading this instruction manual, keep it nearby as a reference in case questions arise during use. If this instruction manual should become lost or damaged, ask your nearest dealer or representative for another copy. Nameplate format 2

Prior to Operation Check the following points upon receipt of your pump: Is the pump exactly what you ordered? Check nameplate. It is especially important that you check whether the pump is to be used with 50 or 60 Hz. Has any damage occurred during shipment? Are any bolts or nuts loose? Have all necessary accessories been supplied? (For a list of standard accessories see Construction page.7) We recommend that you keep a spare pump on hand in case of emergencies. Keep this instruction manual in a place for future reference. Check the nameplate for your pump s head (Hmax), volume (Qmax), speed (R.P.M), motor voltage and current. Installation 1. Check the following before beginning installation. Insulation resistance measurement: With the motor and cable (excluding the power supply cable) immersed in water, use a Megger to measure the insulation resistance between ground and each phase of the motor, and again between each phase of the motor. The Megger should indicate an insulation resistance of not less than 20mega ohms. While making the measurement, keep the power supply cable off the ground. We recommend that an auxiliary pump be kept on hand in case of emergency. 2. Installation- Under no circumstances should cable be pulled while the pump is being transported or installed. Attach a chain or rope to the grip and install the pump. This pump must not be installed on its side or operated a dry condition. Ensure that it is installed upright on a secure base. Install the pump at a location in the tank where there is the least turbulence. If there is a flow of liquid inside the tank, support the piping where appropriate. Install piping so that air will not be entrapped. If piping must be installed in such a way that air pockets are unavoidable, install an air release valve wherever such air pockets are most likely to develop. Do not permit end of discharge piping to be submerged, as backflow will result when the pump is shut down. 3

Electrical Wiring 1.Wiring A) Wire as indicated for the appropriate start system as shown in Fig-1 for single phase version and Fig-2 for three one. B) Loose connections will stop the pump. Make sure all electrical connections secure. 2.Cable! WARNING : Never let the end of the cable contact water. C) If the cable is extended, do not immerse the splice in water. D) Fasten the cable to the discharge piping with tape or vinyl strips. E) Install the cable so that it will not overheat. Overheating caused by coiling the cable and exposing it to direct sunlight. 3.grounding To ground the green wire (label G). Under no circumstances should the green wire be connected to the power supply. 4. WARNING : Use short circuit breakers to prevent danger of electrical shock. Fig-1 Fig-2 4

Operation 1. Before starting the pump 1. After completing installation, measure the insulation resistance again as described in Installation. 2. Check water level. If the pump is operated continuously for an extended period of time in a dry condition or at the lowest water level, the motor protector will be shut off the power. Constant operating in above condition will shorten pump life time. Do not start the pump again in such a situation before the motor has completely cooled. 2. Test operation. Non-automatic pump (GD) (1) Turn the operating switch on and off a couple of times to check switch function. (2) Next, check direction of rotation. If discharge volume is low or unusual sounds are heard when the pump is operating, rotation direction is reversed. When this happens, reverse two of the wires. Maintenance Check pressure, output, voltage, current and other specifications. Unusual readings may indicate. Refer to Troubleshooting and correct as soon as possible. 1. Daily inspections Check current and ammeter fluctuation daily. If ammeter fluctuation is great, even though within the limits of pump rating, foreign matter may be clogged the pump. If the volume of liquid discharged falls suddenly, foreign matter may be blocked the suction inlet. 2. Regular inspections Monthly inspections Measure the insulation resistance. The value should be more than 1M ohm. If resistance starts to fall rapidly even with an initial indication of over 1M ohm, this may be an indication of trouble and repair work is required. Annual inspections To prolong the service life of the mechanical seal by replacing the oil in the mechanical seal chamber once a year. Water mixed the oil or cloudy textures are indications of a defective mechanical seal requiring replacement. When replacing the oil, lay the pump on its side with filler plug on top. Fill suitable amount turbine oil No.32 (ISO VG-32) Inspections at 3-5year intervals Conduct an overhaul of the pump. These intervals will help to avoid possible failure in future. 3. Parts need to be replaced Replace the appropriate part when the following conditions appear. Replaceable part Mechanical seal Oil filler plug gasket Lubricating oil O-ring Condition Oil in mechanical seal chamber Inspect or replace the oil Oil is clouded or dirty Note: above replacement schedule is based on normal operating conditions. Overhaul the pump Frequency Annual Half a year Half a year Annual 5

Construction GD-1.5~3HP 6

N O Name Material Photo NO Name Material Photo 1 Cable H07RN-F / SJTOW/ STOW 11 Impeller FC-200 2 Handle SS41 12 Pump Casing FC-200 3 Motor Cover FC-200 13 Protector 4 Bracket FC-200 14-1 14-2 Upper Bearing Lower Bearing 6203 6304 Run 5 Motor Housing FC-200 15-1 Capacitor (Single Phase Only) Start 6 shaft with Rotor SUS 410 15-2 Capacitor (Single Phase Only) 7 Oil Chamber FC-200 16 Centrifugal switch cover (Single Phase Only) Iron 8 Mech. Seal Upper : CA/CE/NBR Lower : SIC/SIC/NBR 17 Centrifugal switch (Single Phase Only) 9 Seal Housing FC-200 18 Cutter Set SUS 440C 10 Oil Seal NBR 19 Base stand SUS304+ NBR 7

Construction GD-5~7.5HP 8

NO Name Material Photo NO Name Material Photo 1 Cable H07RN-F / SJTOW/ STOW 12 Pump Casing FC-200 2 Handle SS41 13 Protector 3 Motor Cover FC-200 14-1 Upper Bearing 6304 5 Motor Housing FC-200 14-2 Lower Bearing 6305 6 shaft with Rotor SUS 410 18 Cutter SUS 440C 7 Oil Chamber FC-200 19 Base stand SUS304+ NBR 8 Mech. Seal Upper : CA/CE/NBR Lower : SIC/SIC/NBR 20 Bakelite 9 Seal Housing FC-200 21 ~ 23 O-ring NBR 10 Oil Seal NBR 11 Impeller FC-200 9

Troubleshooting Trouble Cause Remedy Does not start. Starts, but immediately stops. Operates, but stops after a while. (1) Power failure (1)~(3) Contact electric power company and (2) Large discrepancy between power source and voltage devise counter-measures (3) Significant drop in voltage (4) Motor phase malfunction (4) Inspect electric circuit (5) Electric circuit connection faulty (5) Correct wiring (6) Faulty connection of control circuit (6) Inspect connections and magnetic coil (7) Fuses is blown (7) Check circuit then replace fuse (8) Faulty magnetic switch (8) Replace with correct one (9) Water is not at level indicated by Float (9) Raise water level (10) Float is not in appropriate level (10) Adjust the position of float (11) Float is not effective (11) Repair or replace (12) Short circuit breaker is functioning (12) Repair location of short circuit (13) Foreign matter clogging pump (13) Remove foreign matter (14) Motor burned out (14) Repair or replace (15) Motor bearing broken (15) Repair or replace (1) Prolonged dry operation has activated motor protector (1) Raise water level to C.W.L and caused pump to stop (2) High liquid temperature has activated motor protector (2) Lower liquid temperature and caused pump to stop (3) Reverse rotation! WARNING : (3) Correct rotation Does not pump. (1) Reverse rotation (1) Correct rotation (see Operation) Inadequate volume. (2) Significant drop in voltage (2) Contact electric power company (3) Operating a 60Hz pump with 50Hz (3) Check nameplate (4) Discharge head is high (4) Recalculate and adjust (5) Large piping loss (5) Recalculate and adjust (6) Low operating water level causes air suction (6) Raise water level or lower pump (7) Leaking from discharge piping (7) Inspect, repair (8) Clogging of discharge piping (8) Remove foreign matter (9) Foreign matter in suction inlet (9) Remove foreign matter (10) Foreign matter clogging pump (10) Remove foreign matter (11) Worn impeller (11) Replace impeller Over current (1) Unbalanced current and voltage (1) Contact electric power company (2) Significant voltage drop (2) Contact electric power company and devise counter-measure (3) Motor phase malfunction (3) Inspect connections and magnetic switch (4) Operating 50Hz pump on 60Hz (4) Check nameplate (5) Reverse rotation! WARNING : (5) Correct rotation (see Operation2) (6) Low head. Excessive volume of water (6) Replace pump with high head pump (7) Foreign matter clogging pump (7) Remove foreign matter (8) Motor bearing is worn out or damaged (8) Replace bearing Pump vibrates; excessive operating noise. (1) Reverse rotation (1) Correct rotation (2) Pump clogged with foreign matter (2) Disassemble and remove foreign matter (3) Piping resonates (3) Improve piping (4) Strainer is closed too far (4) Open strainer 10

Disassembly and Assembly 1. Disassembly- When disassembling pump, have a piece of cardboard or wooden board ready to place the different parts on as you work. Do not pile parts on top of each other. They should be laid out neatly in rows. The O ring and gasket cannot be used again once they are removed. Have replacement parts ready. Disassemble in the following order, referring to the sectional view. Be sure to cut off power source before disassembly. (1) Remove pump casing bolts, raise the motor section and remove pump casing. (2) Remove shaft head bolt and impeller. (3) Remove oil filler plug and drain lubricating oil. (4) Remove intermediate casing bolts and oil chamber. (Remember that any lubricating oil remaining in the mechanical seal chamber will flow out.) (5) Carefully remove mechanical seal, beware of not to scratch sliding surface of motor shaft. 2. Assembly- Re-assemble in reverse order of disassembly. Be careful of the following points. (A) During re-assembly, rotate the impeller by hand and check for smooth rotation. If rotation is not smooth, perform steps-(3) through -(5) again. (B) Upon completion of re-assembly step -(1) rotate the impeller by hand from the suction inlet and check that it rotates smoothly without touching the suction cover before operating the pump. Please order O rings, packing, shaft seals and other parts from your dealer. 11

Vol.PMGD-17021 12