Shut-off valve type AVT and AVM

Similar documents
Flow control valve type SJ

Throttle valve and throttle check valve type CQ, CQR and CQV

Throttle valve type ED, throttle restrictor check valve type RD and RDF

Throttle valve and shut-off valve type CAV

Check valve type ER and EK

Releasable check valve type RH

Releasable check valve type HRP

Flow divider, type TQ

Valve bank type BNG. Product documentation. Manifold mounting Operating pressure p max : Flow rate Q max : 400 bar 60 lpm D 7788 BNG

Releasable twin check valve type DRH

Pump element type MPE and PE for radial piston pumps

Check valve type ER and EK

Check valve type ER and EK

Valve bank (directional seated valve) type BVH

Direct current compact hydraulic power pack type NPC

Connection blocks type AX, ASX, AVX and APX

Variable displacement axial piston pump type V80M

Directional spool valves type SWPN

Releasable twin check valve type DRH

Proportional directional spool valve type EDL

Valve bank (nominal size 6) type BA

Variable displacement axial piston pump type V80M

Pressure controlled the 2-way directional valve type CNE

Variable displacement axial piston pump type V60N

Check valves type CRK, CRB and CRH to screw-in into simple to manufacture tapped holes

Variable displacement axial piston pump type V30E

Proportional pressure reducing valve type KFB 01 (hydraulic joystick)

Hydraulically pilot operated cartridge check valves Type RHC and RHCE without and with hydraulic pre-relief

Discontinued type. 4/3-way proportional pressure reducing valve type FB and KFB (pilot valves)

Lifting / Lowering valve type HSV

Proportional, solenoid actuated flow control valves type SE and SEH

Lifting / Lowering valve type HSV and HZV

Proportional pressure limiting valve Type PMV and PMVP Type PMVS and PMVPS (with external control oil inlet)

Operating manual. General operating instructions: Assembly, commissioning and maintenance B

Variable displacement axial piston pump type V60N

4/3- and 3/3-way directional seated valves type VH (R) and VHP

Directional spool valve type SG and SP

Pressure Relief Valve DB12 CE

Proportional directional spool valve type EDL

Check valve cartridge Type M-SR

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Connection blocks type HMP with integrated lifting and lowering function for proportional spool valves type PSL and PSV, size 2 and 3

Variable displacement axial piston pump type V30E

Double throttle check valve Type Z2FS 10

2-way flow control valve

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Load-holding valves type LHDV

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Check valve, pilot operated

Intermediate plate type NZP hole pattern conforming NG 6 (DIN A6)

Pipe burst safety valve

Internal Gear Pumps Installation Manual

Spindle axis ELGC-BS-KF. Operating instructions [ ]

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Ball valve for pipeline systems

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Throttle and throttle check valve

Pressure reducing valve, pilot operated Type DR

Proportional pressure relief valve, directly operated, rising characteristic curve

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Clamping modules type SMD 2 and NSMD 2 for actuating hydraulic clamping devices

2/2-way poppet valves with solenoid operation Type KSDER1

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Axial piston variable displacement pump type V60N, Serie 03

Directional spool valve type SG and SP

Operating instructions Rescue equipment. Mobile Selection Manifold MSM-2D PN500 - STREAM GB Issue

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Pressure reducing valve, pilot operated

Mini slide EGSC-BS-KF. Operating instructions b [ ]

Axial Piston Units for Use with HF Fluids

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Exchange of rollers from the XTS-Mover

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

These 2/2-way directional cone seated valves show zero leakage while in blocked shifting position. The following versions are available:

Throttle and throttle check valve

Angle seat valve with piston actuator VZXA-...-K

Twin throttle check valve

Proportional flow control valve, with integrated pressure compensator

Reservoir oil filler/breather

A408 GB. Pneumatic oil and diesel pumps 1:1

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Flow Control Valves and Flow Control Valves with reverse flow check DV/DRV

Starting up hydraulic systems

Safety and operating instructions

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Operating instructions Rerailing Equipment. Hydraulic units GB Edition (Translation of the original operating instructions)

Pressure relief valve, pilot operated

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

Priority valve LPS. Data sheet. Series 1 x

Pressure relief valve, pilot operated

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Angle seat valve with diaphragm actuator VZXA-...-M

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Transcription:

Shut-off valve type AVT and AVM Product documentation Operating pressure pmax: Flow rate Qmax: 630 bar 50 lpm D 7690 05-2016-1.1

by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document generated on: 08.11.2017 2/11 D 7690 - AVT, AVM - 05-2016-1.1 HAWE Hydraulik SE

Contents 1 Overview of shut-off valve type AVT and AVM...4 2 Available versions, main data... 5 3 Parameters... 6 3.1 General... 6 4 Dimensions... 8 5 Assembly, operation and maintenance recommendations...9 5.1 Intended use...9 5.2 Assembly information... 9 5.3 Operating instructions...10 5.4 Maintenance information...10 HAWE Hydraulik SE D 7690 - AVT, AVM - 05-2016-1.1 3/11

1 Overview of shut-off valve type AVT and AVM Throttle and shut-off valves are a type of metering valve. With the aid of these valves a pressure drop can be established between the inlet and outlet side. In this way the velocity of cylinders in accumulator circuits and the ow rate in control circuits can be regulated or a consumer line completely shut-off (e.g. to protect a pressure gauge). The throttle and shut-off valve type AVT produces a throttle effect by means of an annular gap. It is mounted in a T-housing. Commercially available pipe screw connections enable a direct pipe connection. Features and bene ts: Various configurations Sensitive adjustment and complete shut off possible Shut-off valve type AVT and AVM Intended applications: General hydraulic systems 4/11 D 7690 - AVT, AVM - 05-2016-1.1 HAWE Hydraulik SE

2 Available versions, main data Circuit symbol: AVT AVM Marking Description Connection pipe # A (mm) AVT 6 6 AVT 8 8 With pipe connection at both ends AVT 10 10 AVT 12 12 Pressure range p max (bar) Output B 630 Input A AVM 8 500 AVM 8 L With pipe bracket at one end 8 315 315 630 HAWE Hydraulik SE D 7690 - AVT, AVM - 05-2016-1.1 5/11

3 Parameters 3.1 General General information Description Design Model Material and surface protection Mounting Installation position Shut-off valve Cone valve Pipe screw connection Steel, seat and cone hardened and ground Freely suspended in pipe As desired Flow direction Recommended A d B: A - in ow side, delivery side to be shut off B - continuing pressure line, return line, element that is shut off (pressure gauge, pressure switch) tight at both ends when closed Hydraulic uid Hydraulic oil: according to Part 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s opt. operation approx. 10... 500 mm 2 /s. Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol) and HEES (synthetic ester) at operating temperatures up to approx. +70 C. Cleanliness level ISO 4406 21/18/15...19/17/13 Temperatures Ambient: approx. -40... +80 C, Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biologically degradable pressure uids: Observe manufacturer's specifications. By consideration of the compatibility with seal material not over +70 C. Pressure and ow rate Operating pressure p max (Chapter 2, "Available versions, main data"); corresponds to nominal pressure with 4x protection against bursting Pressure at B: Pressure at A: Permissible system pressure with valve open Permissible overload capacity at input A with valve closed 6/11 D 7690 - AVT, AVM - 05-2016-1.1 HAWE Hydraulik SE

Characteristic curves Oil viscosity approx. 60 mm 2 /s Sp-Q characteristics Apply to a fully open valve Q ow rate (lpm); Sp ow rate (bar) Weight Type AVT 6 AVT 8 AVT 10 AVT 12 AVM 8 AVM 8 L = 140 g = 175 g = 230 g = 315 g = 110 g = 100 g HAWE Hydraulik SE D 7690 - AVT, AVM - 05-2016-1.1 7/11

4 Dimensions All dimensions in mm, subject to change. AVT AVM s Adjustment travel s Adjustment travel Type H D #d l l 1 s SW1 SW2 SW3 AVT 6 91 40 6 31 -- 3 17 14 -- AVT 8 94 40 8 32 -- 3.5 19 17 -- AVT 10 94 40 10 34 -- 4.5 22 19 -- AVT 12 114 50 12 38 -- 5 24 22 -- AVM 8 91 40 8 29 32 3.5 19 14 19 AVM 8 L 92 40 8 30.5 30 3.5 17 17 19 8/11 D 7690 - AVT, AVM - 05-2016-1.1 HAWE Hydraulik SE

5 Assembly, operation and maintenance recommendations 5.1 Intended use This valve is exclusively intended for hydraulic applications ( uid engineering). The valve demands high technical safety standards and regulations for uid engineering. The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the speci c complete system must also always be observed. If the product can no longer be operated safely: 1. Remove the product from operation and mark it accordingly It is then not permissible to continue using or operating the product 5.2 Assembly information The product must only be installed in the complete system with standard and compliant connection components (screw ttings, hoses, pipes, etc.). The hydraulic power pack must be shut down correctly prior to dismounting; this applies in particular to power packs with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance. HAWE Hydraulik SE D 7690 - AVT, AVM - 05-2016-1.1 9/11

5.3 Operating instructions Product configuration and setting the pressure and ow rate The statements and technical parameters in this documentation must be strictly observed. The instructions for the complete technical system must also always be followed. Note Read the documentation carefully before usage. The documentation must be accessible to the operating and maintenance staff at all times. Keep documentation up to date after every addition or update. Caution Risk of injury due to unexpected movement processes in the machine due to incorrect ow setting! Risk of minor injury Be prepared for unexpected, fast movements. On changing the ow settings, consumers will move more slowly or more quickly. Always monitor the pressure gauge when setting or changing the ow. Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of the hydraulic component. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Pay attention to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters"). 5.4 Maintenance information This product is largely maintenance-free. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year. 10/11 D 7690 - AVT, AVM - 05-2016-1.1 HAWE Hydraulik SE

Further information Additional versions Throttle valve and shut-off valve type AV: D 4583 Throttle valve and shut-off valve CAV: D 7711 Pressure-dependent shut-off valve type DSV: D 3990 Pressure-dependent shut-off valve type CDSV: D 7876 Application Fitting type X 84: D 7077 D 7690 - AVT, AVM - 05-2016-1.1 HAWE Hydraulik SE Streitfeldstraße 25 81673 München Postfach 80 08 04 81608 München Germany Tel +49 89 379100-1000 Fax +49 89 379100-91000 info@hawe.de www.hawe.com