SERIES 2000 GAS SAFETY SHUT OFF VALVE

Similar documents
Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

VML. elektrogas.com. Safety solenoid valves for gas Slow opening and fast closing type DN10 DN80 EE

Old documentation - Only for your information! Product is not available any more!

Manually operated safety shut-off valve HSAV HSAV/5

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Combination controls CG 10

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

B21 Series BASOTROL Gas Valve

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Electro- Hydraulic Actuator Gas Valves GH-5000

VE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

3 Edition Product brochure GB AGA

VE4000 & VE5000 SERIES

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

2-Port and 3-Port Zone Valves, PN16

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

VMH. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN EE

Black Teknigas Combustion Range

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Valve monitoring system VDK 200 A S02

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

EG25*... EG30*... SERIES

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Tightness control TC. Product brochure GB Edition 12.10

3. Operating instructions: Minor 200

2-Port and 3-Port Zone Valves, PN 16 / 20

BGD278 Series BASOTROL CE Approved Gas Valve

Solenoid valves for gas VAS, Double solenoid valves VCS

BGD258 Series BASOTROL CE Approved Class A Gas Valve

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

MS Application. Features. Proportional Valve Actuator General Instructions

Solenoid valves for gas VAS, Double solenoid valves VCS

2-Port and 3-Port Zone Valves & Actuators, PN16

Gas Pressure Governors

VF VFH. elektrogas.com. Butterfly valves DN40 DN150 EE155-11/11

Solenoid valves for gas VAS, Double solenoid valves VCS

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

VLF45... Hot Air Valves. Building Technologies Division

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

VR400/VR800 series UNIVERSAL GAS VALVES CLASS A SERVO REGULATED COMBINATION VALVES APPLICATION. Contents PRODUCT HANDBOOK. General

LK Manifold Shunt VS2

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

BALL VALVE - 10 SERIES Electric actuator - El-O-Matic

EL5600 Series Electric Actuators for DN15 to DN100 Valves

Electromotoric Actuators

Electromotoric Actuators

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

Pneumatic Valve 4V100 Series

Solenoid valves VZWP, servo-controlled

Solenoid Actuated Diesel Engine Air Shut Down Valves

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Series A Electric Linear Actuators

NV Direct Coupled Globe Valve Actuator

Solenoid valves for gas VAS Double solenoid valves VCS

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

Pressostats and thermostats CAS

HS1C Interlock Switches with Solenoid

2-position electric actuators with Ball valves VBZ ½...11/4

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Modulating control valve PN16 with magnetic actuator

Two-stage safety solenoid valves ZRLE/5, ZRDLE/5

Actuators for air dampers and control valves of oil burners

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Electromotoric Actuators

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

PCS. Proof of closure switch for safety gas valves. delta-elektrogas.com EE

Double solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco

Solenoid Valves Type 3963

Delta HE 35-XX, 55-XX

Modulating control valve PN16

Ex m Solenoid Operator Type 0519

BALL VALVE SERIES Electric actuator - El-O-matic

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

PRECISION UK Ltd DUPLEX AGSS PLANT

N/** поставка оборудования для подготовки воздуха

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Valve Box and Valve Accessories G4315A, G4316A, G4317A

BALL VALVE SERIES Electric actuator - El-O-matic

Modulating Control Valve PN 16 with Magnetic Actuator

Transcription:

APPLICATION 2 Series 00 Solenoid Valves are Safety Shut-off or Control Valves for use on gases in gas families 1, 2 and and are also suitable for use with air within the valves pressure range - see specification. Two valves may be bolted together in tandem to form a double block valve. FEATURES * CE Certificated * Range from ¾" to 2" * Flow Restrictor as standard * Flow Regulation from 0 to 100% * Full-wave Rectified Coil for quiet operation * Normally Closed operation * 0mbar maximum working pressure * Pressure Test Points on Inlet and Outlet * Approved to EN161 Group 2, Class A * Available as Fast or Slow Opening * Built in filter * Available with Closed Position Indicator Switch * 2V, 110V and 2V AC 50/60Hz Versions * Range of accessories available * Supplied with PG11 Cable Gland DESCRIPTION Series 00 is a range of Solenoid Operated Safety Shut-off Valves. Their primary application is the on/off control of low pressure 1st (town gas), 2nd (natural gas) and rd (LPG) family gases, although they may also be used as control valves for devices such as automatic burners and for low pressure air applications. The valves are available in screwed connections from ¾ up to 2 and have Flow Adjustment as a standard feature. Slow Opening valves are available and CPI Switches are available as an extra. All valves are supplied with plugged Pressure Test Points in both Inlet and Outlet Ports on both sides of the valve. The valve construction is of an aluminium die-cast body with a solenoid actuator and is maintenance free. There are no user serviceable parts to the valve. Upon being energised, the fast opening valve will open instantaneously whilst the slow opening valve will open within a user adjustable time span of up to seconds. Upon being de-energised the valves will close in less than 1 second. Removal of the power for whatever reason will cause the valves to close. Manual reset switches, for remote mounting are available as accessories. When fitted, manual intervention is required to reopen the valve after removal of the power by, for example, a power cut. To reenergise the valve the switch is momentarily depressed which allows power to the valve, latching the reset switch in the on position and allowing the valve to open. Remote mounted emergency cutout switches are also available in plastic or die-cast housings and also with a key switch operated action. Two types of thermal fuses are also available, either manually resettable or nonresettable where a fuse has to be physically replaced in the device. See accessory section. The photographs, illustrations and descriptions contained in this brochure are solely intended as an indication. Black Teknigas reserves the right to make technical and design changes to its products without prior notice

ORDERING CODES Size Part Numbers Size Part Numbers Type - Fast Opening with Flow Adjustment Type - Slow Opening with Flow Adjustment 2V AC 110V AC 2V AC 2V AC 110V AC 2V AC /" 05 2 V 05 110 V 05 2 V /" 05 2 VS 05 110 VS 05 2 VS 1" 06 2 V 06 110 V 06 2 V 1" 06 2 VS 06 110 VS 06 2 VS 11/" 07 2 V 07 110 V 07 2 V 11/" 07 2 VS 07 110 VS 07 2 VS 11/2' 08 2 V 08 110 V 08 2 V 11/2' 08 2 VS 08 110 VS 08 2 VS 2" 09 2 V 09 110 V 09 2 V 2" 09 2 VS 09 110 VS 09 2 VS Type - Fast Opening with Flow Adjustment and Closed Position Indicator Switch Type - Slow Opening with Flow Adjustment and Closed Position Indicator Switch /" 05 2 VC 05 110 VC 05 2 VC /" 05 2 VSC 05 110 VSC 05 2 VSC 1" 06 2 VC 06 110 VC 06 2 VC 1" 06 2 VSC 06 110 VSC 06 2 VSC 11/" 07 2 VC 07 110 VC 07 2 VC 11/" 07 2 VSC 07 110 VSC 07 2 VSC 11/2' 08 2 VC 08 110 VC 08 2 VC 11/2' 08 2 VSC 08 110 VSC 08 2 VSC 2" 09 2 VC 09 110 VC 09 2 VC 2" 09 2 VSC 09 110 VSC 09 2 VSC SPECIFICATION Media: Non-corrosive gases and air, approved for use with gas families 1. Town Gas 2. Natural Gas. LPG Media Temperature Range: -10 o C to +60 o C Ambient Temperature Range: - o C to +60 o C Opening Speed etc.: Fast Opening Models < 1 sec. Slow Opening Models < 1 sec to sec Closing Speed: All models < 1 sec Flow Regulation: 0 to 100% repeatable Electrical: Models available 2V AC 50Hz 110V AC 50Hz 2V AC 50Hz Rating: All Models ¾ - 1 VA 1¼ - 1½ 7VA 2 VA Maximum Switching rate: 1000 cycles per hour Pipe Connections: Rp ¾ up to Rp 2 - ISO 7-1 Pressure Test Points Plugged test point on Inlet and outlet ports on both sides of body Inlet Pressure: All models - 0 mbar Seat Disc: Buna N Cable Gland: Pg 11 - supplied Environmental: IP5 - IEC 529 Filter: 1mm wire mesh Approvals: All models approved to EN161 Class A, Group 2 for Gas Families 1, 2 and EC Certificated EN 126 Closed Position Indicator Switch (if fitted) 2 normally open contacts Voltage 250V AC, Consumption 10W Rating 10VA Maximum

DIMENSIONS Model Connections A B C D E BC 05V/VC Rp/" 126 8 12 7 26 BC 05 VS/VSC Rp/" 126 8 216 7 26 BC 06V/VC Rp 1" 126 8 12 7 26 BC 06 VS/VSC Rp 1" 126 8 216 7 26 BC 07V/VC Rp 1.1/" 167 57 167 11 29 BC 07 VS/VSC Rp 1.1/" 167 57 25 11 29 BC 08V/VC Rp 1.1/2" 167 57 167 11 29 BC 08 VS/VSC Rp 1.1/2" 167 57 25 11 29 BC 09V/VC Rp 2" 195 62 171 15 2 BC 09 VS/VSC Rp 2" 195 62 250 15 2 Note for 'VC' and 'VSC' models add mm to dimension 'B'. Dimensions in millimetres

5 Fig.1 - Flow Adjustment - see Page 6 Fig 2. - Flow and Opening Time Adjustment - see Page 6 Fig. - Series 00 Component Parts 1 - Top Cap 2 - Flow Adjustment Screw - Armature - Body Top 5 - Valve Spring 6 - Filter 7 - Valve Head 8 - Coil 9 - Armature Housing 10 - 'O' ring 11 - Valve Body 12 - Flange Screws 1 - Inlet Flange 1 - Cover Screws - Cable Gland 16 - Electrical Housing 17/19 - Pressure Test Plugs 18 - Outlet Flange

FLOW CHART 6 50 2 0 0 5 2 0 0 6 2 0 0 7 2 0 0 8 2 0 0 9 Pressure loss Äp mbar 10 7 5 2 1 Natural Gas 5 Air L.P.G. Town Gas 6 7 8 9 10 5 6 5 7 8 9 10 7 8 9 10 6 7 8 9 10 50 70 100 50 70 50 70 100 0 0 0 50 70 100 0 0 100 0 0 0 0 500 0 500 0 Flow Rate Q - m /h INSTALLATION AND OPERATION Installation Observe local Codes of Practice e.g. Use of CORGI registered installers. Avoid installing in contact with plastered walls. Ensure that gas and electricity supplies are adequate and ambient temperature is suitable. Switch off gas supply before commencing installation. Connecting pipework must be clean. Mount Valve onto pipework using a suitable thread sealant which must be applied to the pipework, not the internal thread of the valve. When installing a valve in pipework do not use the coil as a lever, but use the correct wrench. Valves may be mounted either horizontally or vertically providing that the actuator is not below the valve body. Ensure that the flow arrow on the valve body is in the correct position in relation to the gas supply. Fitting an upstream gas filter is recommended. To connect two valves together use the 'O' ring and screws set available for this purpose. If fitting more than three series 00 valves in line, the valves must be supported. Ensure that the electrical supply is m.c.b. protected or fitted with a slow blow fuse rated slightly higher than the maximum power requirement for the valve (See specification). Refer to wiring diagram illustration and connect supply to screw terminals, as indicated. Where necessary make connections to Closed Position Indicator (CPI) Switch. Commissioning Leak test the Gas connections, Switch on Gas supply, Test points may be used to establish static pressure of the gas supply. Control is now ready for service. Flow Adjustment - see diagrams page 5 Series 00 valves are fitted, as standard, with a flow adjuster. This device acts by restricting the opening of the valve and allow the gas flow to be adjusted from 0 to 100%. To adjust the gas flow unscrew the coil top cap (1) to access the adjuster screw (2 - also 'B' fig 2) inside the flange tube (9) of the valve. Use a flat bladed screw driver to make the adjustment. Turn the screw clockwise to reduce the flow and counterclockwise to increase it. When the screw is completely tightened there is no gas flow and maximum flow occurs when the screw is completely loosened. Opening Time Adjustment on Slow Opening Models Slow Opening valves are factory set at minimum opening time. To adjust, Firstly remove the top cap (1) on the top of the coil and then with a flat bladed screwdriver (1 x 5.5) turn screw 'A' (fig.2) either clockwise to increase speed or anti-clockwise to decrease speed. Maximum time from fully open to fully closed is seconds. See Fig.2 page 5. Please read the preceding installation and operating instructions. This equipment must be installed in accordance with current regulations Wiring Diagrams for Valves (left) and CPI - if fitted (right). N GND L