U S E R M A N U A L SAVE THESE INSTRUCTIONS

Similar documents
U S E R M A N U A L SAVE THESE INSTRUCTIONS

portable ac/dc suction pump USER S MANUAL ITEM # 18605

Model 605 Portable Aspirator

INSTRUCTIONS FOR USE. Rx Only

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Rectal Light Handle REF V Power Supply REF 73305, 73322, 73324, 73326

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

900 PEAK AMP PORTABLE JUMP STARTER

OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Laerdal Compact Suction Unit 4

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Firstmate Installation Manual and User's Guide May, 2003

OPERATING INSTRUCTIONS. MAINTENANCE MANUAL S-SCORT Model 2300 Suction Series

Duo Massager. Cordless Shiatsu & Percussion Massager

SUPER PUMP OUT SYSTEM

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Register your product and get support at Philips Sonicare DiamondClean

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

USER'S GUIDE 9151 SERIES V

SMOKE EVACUATION SYSTEM SAFETY PRECAUTIONS

MV Series Motors Operation & Parts Manual

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

600 Amp Battery Jumper with Air Compressor

Item no Smart AC 200 USB. User s Manual

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.

SUBMERSIBLE MINI-PUMP

VANGUARD A EZ INSTALL OPERATOR S MANUAL

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

SUNC3000 / Item #40885

Submersible Pond Pump with UV 800 Gallons Per Hour

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Language specific user manuals are available on

1 AMP CURRENT SOURCE

II DISTRIBUTION & SUBSTATION TYPE C

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

Sentinel Enteral Feeding Pump. Model: S-1000-SI. Operating Manual

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Matson Jump Starter Operator s Manual

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Invacare. Battery Charger User Manual. Model: POC1 115, POC1 115 AZ, POC1 115 C, POC1 115 EU

4-VOLT LITHIUM-ION AUTO-LOAD SCREWDRIVER w/led WORKLIGHT

U-Control. User's Manual. EMG Home Trainer. Thought Technology Ltd.

JUMP STARTER OPERATOR S MANUAL RA1900

Owners Manual. LifeGuard Power Lift Model # Rev. 2/1/13

LifeGuardLift. LifeGuard Power Lift Model #100287A OWNERS MANUAL. Rev: 2/14/11

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

Hydraulic Immediate Need Power Pack

Owner s Manual. Features

Armon Edero. User manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

AUTOMATIC SUBMERSIBLE UTILITY PUMP

Operator s Safety and Service Manual

TWO YEAR LIMITED WARRANTY MOMENT NOW PLEASE TAKE A INSTRUCTION MANUAL AND WARRANTY INFORMATION MP-15-THP

Model G14SD Vapor Management System

Cordless Make Up Mirror WITH ILLUMINATED 1X AND 10X MAGNIFICATION PLUS NIGHT LIGHT

INSTALLATION INSTRUCTIONS

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

Jetpik. Model JP-51M/51/210/250-SOLO Power Floss System

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

12.0-Volt Lithium-Ion Power Source

Operating Instructions

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

FastPrep FP120 Cell Disrupter INSTRUCTION MANUAL

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

Instructions For Use VATEA. Endodontic Irrigation Device

Model 1672, 1673 Triple Output Power Supply

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

20A Solar Charge Controller

Installation Power Management Unit Battery Cables and Battery Harness

StormPro BA Series Sump Pump

6 Bay Battery Charger Operation Manual

60V RECHARGEABLE LITHIUM-ION BATTERY

Printed: Doc-Nr: PUB / / 000 / 00

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

INSTALLATION INSTRUCTIONS

CLASSIC II Portable Braking System

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

IMPORTANT SAFETY INSTRUCTIONS

Owner s Manual & Safety Instructions

D Instructions/Parts. Siphon Feed Detail Spray Gun D

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL S-SCORT Ten Model 2100 and 2100S

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AA-98 AirPac II Compressor 110V

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Language specific user manuals are available on

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Air-Operated Waste Oil Drainer

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

Parts Manual Vermeer/ McLaughlin Mud System 230P

User s Manual. Item no. 2561


Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Transcription:

U S E R M A N U A L Model No. PM65 PM65E PM65HG SAVE THESE INSTRUCTIONS Federal (USA) law restricts this device to sale by or on the order of a physician. 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 ISO 13485 Certified www.precisionmedical.com

RECEIVING / INSPECTION Remove the Precision Medical, Inc. Easy Go Vac Aspirator from packaging and inspect for damage. If there is any damage, DO NOT USE and contact your Provider. Intended Use The Easy Go Vac Aspirator provides a portable, AC/DC powered medical vacuum source. It is intended for use in the homecare / healthcare environments. READ ALL INSTRUCTIONS BEFORE USING This manual instructs a Professional to install and operate the Easy Go Vac Aspirator. This is provided for your safety and to prevent damage to the Aspirator. If you do not understand this manual, DO NOT USE the Aspirator and contact your Provider. Explanation of abbreviations mmhg Millimeters of Mercury kpa Kilopascal inhg Inches of Mercury l/min Liters per Minute SAFETY Information - Warnings and Cautions Indicates an imminently hazardous situation which, if DANGER not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if 0473 not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. Symbol indicates the device complies with the requirements of Directive 93/42/EEC. (On CE marked Devices ONLY) CONSULT ACCOMPANYING DOCUMENTS Type BF equipment Suction "OFF" (Battery Charging mode when plugged into charger.) Suction "ON" 1

DANGER To reduce the risk of Electrocution: Always unplug the Easy Go Vac Aspirator after using, except when battery is being recharged. DO NOT use while bathing. DO NOT place or store the Aspirator where it can fall or be pulled into a tub or sink. DO NOT place or drop into water or other liquid. DO NOT reach for the Aspirator that has fallen into water. Unplug immediately. DO NOT attempt to repair the Aspirator. Any attempt could result in electrical shock. DO NOT use near any type of flame or flammable/explosive substances. DO NOT allow Aspirator to exceed Operating or Storage Temperature specifications. Caution must be exercised when operating the Easy Go Vac Aspirator where oxygen is being administered. Equipment not suitable for use in the presence of flammable anesthetic mixture with air, oxygen or nitrous oxide. To reduce risk of burns, electrocution, fire, or injury to persons: Close supervision is necessary when this Easy Go Vac Aspirator is used by, on, or near children or invalids. Use this Easy Go Vac Aspirator only for its "Intended Use" as described in this manual. DO NOT use attachments not recommended by the Precision Medical, Inc. DO NOT use when sleepy or drowsy. DO NOT use if the Aspirator has a damaged cord or plug. DO NOT use if the Aspirator has been dropped or damaged. Connect this Aspirator to a properly grounded outlet only. See GROUNDING INSTRUCTIONS. Keep the cord away from heated surfaces. Use ONLY the Battery Charger / Power Supply provided by Precision Medical, Inc. Use of other Battery Chargers / Power Supplies is not recommended and will void the warranty. 2

SPECIFICATIONS Dimensions (in Carry Bag): Length: 12 in (30 cm) Width: 9.5 in (24 cm) Height: 10 in (25 cm) Weight (with Carry Bag and all Accessories): 9.6 lbs (4.4 kg) Shipping Weight: 11 lbs (5 kg) Suction Canister: 800cc Max Volume Vacuum is not to exceed 25 inhg (635 mmhg). The Canister Lid has a float shut off valve, that protects the Aspirator from overfill. Patient Tubing: 1/4 in. ID Non-Conductive PVC tubing, 6 ft. long, with 1/4 in.- 3/8 in. ID female connectors, or equivalent Filter: Inline, Hydrophobic Vacuum: 2-21 inhg (51-533 mmhg) Flow: 6.5 ± 0.4 l/min @ 11.8 inhg (300 mmhg) Electrical: Aspirator Unit: 12 Volts DC, 1.8 Amps Battery Charger / Power Supply: 100-240 Volts AC, 50-60 Hz, 0.80-0.35 Amps Internal Battery Type: 12 Volt, Sealed Lead Acid Operating Temperature Range: 50 F to 104 F (10 C to 40 C) Storage / Transport Requirements Temperature Range: -4 F to 104 F (-20 C to 40 C) Maximum Humidity: 95% Noncondensing Equipment Classification: Class I - with respect to protection from electrical shock Type BF - degree of protection against electrical shock IPX0 - degree of protection against ingress of liquids Mode of Operation - continuous Specifications are subject to change without prior notice. 3

Component description If for any reason any label becomes illegible or lost, contact Precision Medical, Inc. On/Off Switch External Power Jack Vacuum Control Knob Inline Hydrophobic Filter Vacuum Gauge Yellow Low Battery Light AC Power Cord Patient Tubing Connection Suction Canister (Built in overfill protection device) Battery Charger/ Power Supply Patient Suction Tubing 4 Auto DC Power Cord (optional) Grounding instructions The Battery Charger Power Supply should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electrical current. This Battery Charger Power Supply is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded. DANGER Improper use of the grounding plug can result in a risk of electrical shock. Ground reliability can only be achieved when the power cord is connected to an equivalent receptacle marked "Hospital Grade".

OPERATING INSTRUCTIONS Inspect the Easy Go Vac Aspirator for visual damage, DO NOT USE if damaged. 1. Place the Easy Go Vac Aspirator in the upright position on a level surface. 2. Make sure the On/Off ( / ) Switch is in the OFF position. 3. Be sure the Inline Hydrophobic Filter and tubing is properly connected to the vacuum port on the Suction Canister lid. The Inline Hydrophobic Filter prevents liquid from entering the vacuum pump. 4. Select appropriate Mode of Operation. DO NOT run the Easy GO Vac Aspirator without the Inline Hydrophobic Filter. This will void the warranty. A. AC electrical receptacle operation (100-240 Volts AC) a. Insert the small plug on the cord from the Battery Charger/Power Supply into External Power Jack on the Easy Go Vac Aspirator. b. Connect the female end of the AC Power Cord into the Battery Charger/ Power Supply. c. Plug the male end (3 prong plug) into a grounded receptacle. 5. Push the On/Off ( / ) Switch to the ON position. 6. Block the patient connection on the Suction Canister and adjust the Vacuum Control Knob to the desired vacuum. To INCREASE vacuum - Turn knob CLOCKWISE To DECREASE vacuum - Turn knob COUNTERCLOCKWISE NOTE: Vacuum should be set as prescribed by your Provider. 7. Connect one end of the Patient Suction Tubing to the port on the canister marked Patient Tubing. 8. Connect the other end of the Patient Suction Tubing to the suction catheter and begin procedure as instructed by your Provider. 9. When procedure is completed, press the On/Off ( / ) Switch to the OFF position. NOTE: DO NOT overfill the Canister. 5

10. Empty the Suction Canister as follows: Disconnect patient tubing and elbow fitting from the top of the Canister. Remove the canister from its bracket and empty as instructed by your Provider. 11. Replace Suction Canister and reconnect all suction tubing. Canister is single patient use only. B. Internal Battery Operation 1. Steps 1 thru 4, see OPERATING INSTRUCTIONS. Battery should be fully charged before using; to charge battery, see CHARGING BATTERY. When the yellow Low Battery Light is on continuously during normal use, the battery needs to be charged. If automatic shut off occurs during battery operation, the Aspirator cannot be restarted until the battery has been recharged, or until the Aspirator is connected to either of the external power source options. 5. Push the On/Off ( / ) Switch to the ON position. If yellow Low Battery Light stays on continuously, battery needs charging. Charge battery or use another Mode of Operation. Operating Aspirator after yellow Low Battery Light has been on continuously, will cause automatic shut down. 6. Steps 6 thru 11, see OPERATING INSTRUCTIONS. C. Auto DC Operation (Auto Power Port) 1. Steps 1 thru 4, see OPERATING INSTRUCTIONS. a. Insert small plug on the Auto DC Power Cord into the External Power Jack on the Aspirator. b. Plug the other end into the auto power port receptacle. 6

DO NOT leave the Aspirator connected to the auto power port when not in use. Failure to follow these instructions can cause severe battery failure and will void the warranty, see charging battery. 5. Push the On/Off ( / ) Switch to the ON position. If yellow Low Battery Light stays on continuously, battery needs charging. Charge battery or use another mode of operation. Operating Easy Go Vac Aspirator after yellow Low Battery Light has been on continuously, will cause automatic shut down. 6. Steps 6 thru 11, see OPERATING INSTRUCTIONS. Charging Battery 1. Insert small plug on cord from the Battery Charger/Power Supply into External Power Jack on the Aspirator. 2. Connect the female end of AC Power Cord into the Battery Charger/Power Supply. 3. Plug male end (3 prong plug) into a grounded receptacle. Amber light on Battery Charger / Power Supply will come on. When amber light changes to green, battery is fully charged. Average charging time is 2-4 hours. (A new battery may take longer to fully charge the first time.) NOTE: No damage will occur if the charger is left connected. 4. Disconnect AC Power Cord from AC receptacle. 5. Disconnect cord from External Power Jack on Aspirator. When fully charged, battery will provide approximately 120 minutes of operation in 8, 15 minute intermittent duration periods. CLEANING / MAINTENANCE Turn the Aspirator OFF and disconnect from any external power source before cleaning. DO NOT clean the Aspirator with Alcohol, Acetone or other solvents. Inline Hydrophobic Filter: This filter cannot be cleaned. If it becomes contaminated or clogged, it must be replaced. 7

To replace Inline Hydrophobic Filter: 1. Disconnect filter assembly from Suction Canister and remove Suction Canister from the Aspirator. 2. Unscrew filter assembly from the Aspirator. 3. Dispose of filter. 4. Install new filter (Part #506047) by screwing filter into the Aspirator, until hand tight. Then reconnect tubing and elbow. DO NOT use sealing material on the filter threads. Tubing is single patient use only. DO NOT clean. Cleaning for Exterior Components: 1. Disconnect the Aspirator from power source and other connections before cleaning. 2. Use a cloth or sponge dampened with soap and water. 3. Wipe dry with a clean cloth or paper towel. 4. Store the Aspirator in a clean area free from grease, oil, and other sources of contamination. Returns Returned products require a Returned Goods Authorization (RGA) number, contact Precision Medical, Inc. All returns must be packaged in sealed containers to prevent damage. Precision Medical, Inc. will not be responsible for goods damaged in transit. Refer to Precision Medical, Inc. Return Policy available on the Internet, www.precisionmedical.com. Manuals available on our Website; www.precisionmedical.com Disposal Instructions Dispose of Bio-waste products as described by your Healthcare Professional or Healthcare Facility protocol. The Easy Go Vac Aspirator contains a sealed lead acid battery. DO NOT dispose with normal trash. Consult your local waste management authority for proper disposal procedures. If Aspirator is used for treatment of infectious disease, consult your Physician or Healthcare Professional for recommended procedures for proper disposal. Please Recycle 8

Troubleshooting If the Easy Go Vac Aspirator fails to function, consult the Troubleshooting Guide. If the problem cannot be corrected, consult your Provider. There are no user serviceable parts inside. DO NOT open case. Problem Probable Cause Remedy Aspirator will not operate on battery Aspirator will not operate when connected to AC Power Source Aspirator will not operate when connected to Auto DC Power Cord Battery will not charge Unable to adjust vacuum 1. On/Off Switch in OFF position 2. Battery not charged (Low battery light on) 1. On/Off Switch in OFF position 2. AC Power Cord not connected 1. On/Off Switch in OFF position 2. Auto DC Power Cord not connected properly 3. Defective auto power port receptacle 4. Defective Auto DC Power Cord 1. Not connected to Battery Charger / Power Supply 2. Defective Battery Charger / Power Supply 3. Defective battery 1. Filter assembly not connected properly 2. Suction Canister not connected properly 3. Filter clogged 4. Defective Suction Canister 5. Defective Aspirator Tell us how we are doing! Visit us at www.precisionmedical.com 1. On/Off Switch to ON position 2. Recharge battery If battery will not charge, contact your Provider 1. On/Off Switch to ON position 2. Check connection at both AC Power Source and Aspirator 1. On/Off Switch to ON position 2. Check connections at both ends of cord 3. Connect to a known working auto power port 4. Contact your Provider 1. Connect Battery Charger/Power Supply 2. Contact your Provider 3. Contact your Provider 1. Confirm and tighten connections 2. Confirm and tighten connections 3. Replace filter assembly 4. Replace Suction Canister 5. Contact your Provider 9

Replacement Parts Description Part # Filter 506047 Filter Assembly 503293 800cc Canister, (Case-10 ea.) 502519-10 Patient Suction Tubing 1955 Charger 503974 Carry Bag 502956 AC Power Cord 503106 Auto DC Power Cord 502954 DECLARATION OF CONFORMITY Precision Medical, Inc 300 Held Drive Northampton PA 18067, USA 0473 Emergo Europe (European Office) Molenstraat 15 2513 BH, The Hague The Netherlands Phone: +31 (0) 70.345.8570 Fax: +31 (0) 70.346.7299 PM65HG, PM65E Classification: IIa Classification criteria: Clause 3.2 Rule 11 of Annex IX of MDD We hereby declare that an examination of the under mentioned production quality assurance system has been carried out following the requirements of the UK national legislation to which the undersigned is subjected, transposing Annex II, 3 of the Directive 93/42/EEC on medical devices. We certify that the production quality system conforms with the relevant provisions of the aforementioned legislation, and the result entitles the organization to use the CE 0473 marking on those products listed above. Applied Standards: BS EN 1041, EN 60601-1, EN 60601-1-2, EN ISO 10079-1, EN ISO 14971, ISO 13458, ISO 15223-1 Notified Body: AMTAC Certification Services Limited 0473 Address: Davy Avenue Knowlhill Milton Keynes MK5 8NL, UK Certification Registration No s: 1126 CE Date of Expiry: 03 August 2017 Devices already manufactured: S/N traceability Device History Records Validity of DOC: 04 August 2012 to Date of Expiry Manufacture Representative: Quality Manager Position: Quality Systems/ISO Representative Date of Issue: 04 August 2012 10

LIMITED WARRANTY AND LIMITATION OF LIABILITY Precision Medical, Inc. warrants that Easy Go Vac Aspirator (the Product) and the following component parts thereof will be free of defects in workmanship and/or material for the following periods: Easy Go Vac Aspirator Battery Two (2) years from shipment Six (6) months from shipment Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc. s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense. ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES. The representatives of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of that contract. THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED. Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications without notice. Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty. 502598 Rev10 10/22/12 (?M) Printed in USA