MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

Similar documents
OPERATING MANUAL POWER DRIVE SYSTEM. Cat. No RevH


OPERATING MANUAL. Cole-Parmer Stir-Pak General-Purpose Laboratory Mixer. Model Number General-Purpose Laboratory Mixer System

Rectal Light Handle REF V Power Supply REF 73305, 73322, 73324, 73326

PUMP SYSTEM OPERATING MANUAL:

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

3 PHASE TESTER & MOTOR ROTATION TESTER

LED Exam Light. Service and Parts Manual. Model Numbers: FOR USE BY MIDMARK TRAINED TECHNICIANS ONLY Rev. (1/23/18)

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-707A & AEU-707AV2 Implant / Surgery Systems

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Fiber Optic Illuminator. Model 21AC Model 21DC

Xenon Fiberoptic Lightsource

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Before installing this unit, read the operating instructions carefully. Strictly adhere to these operating instructions.

RemRest. Service Manual. CAUTION: USA Federal law restricts this device to sale by or on the order of a physician. P/N Rev A

OPERATION and MAINTENANCE INSTRUCTION MANUAL

INSTRUCTIONS FOR USE. Operation and Maintenance manual. Light Industrial Compressor. Hi-Tech Diagnostics Service

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Instructions For Use VATEA. Endodontic Irrigation Device

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Introduction. The words WARNING, CAUTION and NOTE carry special meanings and should be carefully reviewed.

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-70A Peristaltic Infusion Pump

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

OPERATING MANUAL HAZARDOUS-DUTY PUMP DRIVE

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-7/AEU-7P Peristaltic Water Pump

Filtered PWM Speed Control for Permanent Magnet DC Motors

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

UNIVERSAL BATTERY CHARGER II

SPECIFIC TECHNICAL CRITERIA

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

IsoLED FLEX I CUSTOMER MANUAL

Versatile and Powerful

HLS Watt Halogen Illuminator Service Manual

Language specific user manuals are available on

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-500 Mini-Electric Portable Dental System

System 3 ZB1PS Device Chassis. Operator s Manual

1 AMP CURRENT SOURCE

s h a p e f i t t i n g t e c h n o l o g y

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Mini Multimeter with Non-Contact Voltage Detector (NCV)

THE PHOENIX MODEL 1800 KNEE CPM OPERATOR'S MANUAL SERIES Seeds Road Grove City, OH Fax

ZG-JSL, ZG-JSLA Jackshaft Retrofit Linkage For AF, NF, LF, NMX and AMX Series Actuators

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

MF4E MF4E

PPD-130 PERISTALTIC PUMP DISPENSER

Operator's Manual Tracer III Nerve Locator, Model NL-3

Users Manual. Phase Rotation Indicator

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

TITAN Tx350 Model Tx350-A Xenon Illuminator with Manual Dimming Operation Manual

Laerdal Compact Suction Unit 4

Digital Apex Locator. ipex OPERATION MANUAL OM-E0285E

LDLS Laser-Driven Light Source. EQ-1000 High Brightness DUV Light Source. Operation Manual

SmartVent. Instructions for Use Version 4 (Dec 2009)

Language specific user manuals are available on

XENON 300 LIGHT SOURCE

Model G14SD Vapor Management System

Model 605 Portable Aspirator

HL (AZH) LIMIT SWITCHES

Installation Manual 354 / 355 Combination Lighting System

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

LF Series At A Glance

BEL-50N DENTAL CHAIR OPERATING INSTRUCTIONS IMPORTANT

Table of Contents. Classifications.. 5. Installation.,12. Focusing..14. Operating Instructions..15. Charts Description Maintenance...

Minimum 27 in-lb torque

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Universal Battery Charger II.

Versatile and Powerful

Techcon Systems TS6500 CIM Automatic Techkit Mixer

Alternating Current Revolution per minute Protective Earth Ground. Protected from dripping water Fuse Attention, Consult Accompanying Document

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

CCTV Rack Mount Power Supplies

PerfectSpeed NEMA 48 Pump Motor. With User Interface

COOKSON OWNER'S MANUAL

OPERATION and MAINTENANCE INSTRUCTION MANUAL. ADU-12DCE Task Force Deluxe Portable Pneumatic Dental System

User Manual SONESTA S2 & S3

Minimum 27 in-lb Torque

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

CCTV Rack Mount Power Supplies

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

OPERATING INSTRUCTIONS

SMOKE EVACUATION SYSTEM SAFETY PRECAUTIONS

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

AM-134, AM-140, AM-234, AM-240, AM-334, AM-340, AM-368

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

DC CCTV Power Supplies Installation Guide

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Transcription:

OPERATING MANUAL: MEDICAL IRRIGATION K PUMP Manufactured for: K.M.I 3185 Palisades Dr Corona CA 92880-9432 USA 1-866-412-7867 Model No. 1000-0031 A-1299-5091 Edition 01

TABLE OF CONTENTS Title SAFETY PRECAUTIONS & ICON DEFINITIONS.................................................... 2 GENERAL DESCRIPTION..................................................................... 3 SETUP AND DRIVE OPERATION................................................................ 3 TECHNICAL DESCRIPTION....................................................................4 TROUBLESHOOTING.........................................................................5 MAINTENANCE/CLEANING.................................................................... 6 SERVICING.................................................................................6 NOTE: PRIOR TO PROCEEDING PLEASE READ "SAFETY PRECAUTIONS" and ICON DEFINITIONS" SAFETY PRECAUTIONS CLASSIFIED C 58XL US MEDICAL EQUIPMENT WITH RESPECT TO ELECTRICAL SHOCK, FIRE, MECHANICAL AND OTHER SPECIFIED HAZARDS ONLY IN ACCORDANCE WITH UL 2601-1, AND CAN/CSA C22.2 NO. 601.1 Page ELECTRICAL SHOCK HAZARD. DO NOT REMOVE COVER. Refer servicing to qualified service personnel. RISK OF FIRE, DO NOT REPLACE FUSES. Refer servicing to qualified service personnel. EXPLOSION RISK if used in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide. ICON DEFINITIONS ATTENTION: Consult accompanying documents Type BF equipment Alternating current Fuse symbol OFF ON (Power: connected to Mains) FWD REV Forward (Clockwise rotation) Reverse (Counterclockwise rotation) 2

GENERAL DESCRIPTION This Medical Irrigation Pump is designed with a user selectable Mains power input module and an Easy-Load pump head with safety interlock. The pump head safety interlock is enabled when the pump head cam lever is opened; exposing the pump head rollers. Power On/Off switch is located on the rear panel with a "power on" green LED indicator on the front panel. Motor control is PWM circuitry with indirect velocity feedback for load/line regulation and speed control. Pump speed (flow rate) is set by a user adjustable single turn potentiometer located on the front panel. Remote Drive "On/Off operation is available through an air actuated foot switch. SETUP AND OPERATION 1. Lift pump head lever to the up position to allow loading of the peristaltic tubing/tubing section. Peristaltic tubing/ tubing specifications: Material: Silicone Sizes: 3 16" I.D x 3 8" O.D orr 1 4" I.D x 7 16" O.D 2. Place tubing on roller section ensuring flow direction is from left to right as facing the unit. 3. Lower pump head lever to the down (closed) position and lock in place. 4. Secure tubing by locking the tubing retainers in place. Press in tubing retainer tabs on the side of the pump head and lower until tubing is secured. 5. Connect foot switch to ports located on the front of the pump. 6. Select desired rotation of pump head. ie: FWD (Forward) for irrigation; REV (Reverse) for removal. 7. Turn power to the medical irrigation pump ON. 8. Select desired pneumatic foot switch to be used. 9. Depress foot switch operation to start the pumps operation, depress again to discontinue pump operation. 10. Adjust flow rate with the 1-turn potentiometer speed control. Note: rotating dial clockwise (CW) will increase flow rate, counter clockwise (CCW) will decrease flow rate. Dial indicator numbers are relative and do not indicate a specific flow rate. Flow rate must be empirically correlated to dial indicator problem. 3

TECHNICAL DESCRIPTION Drive Speed Range: Maximum Torque: Flow Rate: Mode of Operation: Rated Input Voltage: Rated Input Frequency: Mains Power Input Fusing: 10-600 rpm 50 oz. in. Up to 1000 ml/min. depending upon tubing and pump speed Continuous (Forward or Reverse) 110/ 120 VAC, 220/ 240VAC (qualified service technician selectable) 50/60Hz (2) T 1.0A/250V for 110/120 VAC input power selection. (2) T 0.6A/250V for 220/240 VAC input power selection. Fusing replaceable by qualified service technician. Mains Power Connection: IEC 320, Use only cordage terminated in HOSPITAL GRADE plugs to insure power grounding. Speed Regulation: Line: +/- 2% Load: +/- 1% Temperature Drift: +/- 10% Humidity (non-condensing): 10% to 90% Operating Temperature: 0 to 40 C Storage Temperature: -45 to 60 C Atmospheric Pressure Range: 500Hpa to 1060hPa Protection against shock: Enclosure rating: Chemical Resistance: Display: Remote: Dimensions: (L x W x H): Weight: Pollution Degree: Class I, Type BF Ordinary equipment All materials will withstand mild disinfectant solution or cleaning solvents. Green LED Foot switch with 10 ft. PVC hose, air actuated. 219.1 x 190.5 x 114.3 mm (8 5 8 in x 7 1 2 in x 4 1 2 in) 4.08 kg (9.0 pounds) Pollution Degree 2 per IEC 664 (Indoor usage lab, office) Installation Category: Installation Category II per IEC 664 (Local level appliances, portable equipment etc.) 4

TROUBLESHOOTING CAUTION: SHOCK HAZARD! DO NOT REMOVE COVER. High voltage exists and is accessible in the Medical Irrigation Pump. 1. Power ON indicator does not illuminate. a. Verify power cord is inserted in Pumps power entry module. b. Verify power entry module power switch is in the ON position. c. Verify Mains power circuit breaker is ON. d. If (a), (b), (c) verify OK and power ON indicator remains off, return Pump to manufacture for servicing. 2. Pump does not RUN, power ON indicator is illuminated. a. Verify tubing is loaded properly and that the pump head lever is latched by pushing down on it. b. Verify pump head screws are securely tightened. c. Verify FWD/ REV switch in the FWD or REV position, not center position which is OFF. d. If (a), (b) and (c) verify OK, return Pump to manufacture for servicing. 3. Pump runs in the wrong direction. a. Verify FWD/ REV switch is in the desired position. 5

MAINTENANCE/ CLEANING Disconnect Medical Irrigation Pump from the power mains. 1. Wipe down outside of pump and pump head with a mild sanitizing solution and dry. DO NOT IMMERSE PUMP in liquid or use excessive liquid. 2. Verify ground wire condition in power cord. SERVICING No user repairable parts available. Refer all servicing to the manufacture. 6

NOTES... 7