ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

Similar documents
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. Electronic unit and accessories Retrofitting on Contrac

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

FICHA TÉCNICA DE PRODUTO

Model 3400 Intrinsically Safe Load Cell

ABB i-bus KNX DG/S x DALI-Gateway Basic

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Moving Coil Indicators with direct temperature sensor input

Thermal overload relay TF140DU and TF140DU-V1000

Additional Information. Measurement made easy

Service Fieldbus Engineering and Consulting

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

RS85 Vibrating fork level switch

Electronic overload relays EF205 and EF370

Shut-off valves and accessories for pressure measuring instruments

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

Technical Description. Wireless Automation Accessories

Control Valve 23 / 24 Single-seat straight-way valve with exchangeable seat ring

The perfect solution for wellhead flow measurement with CoriolisMaster, ProcessMaster and VortexMaster

MW05 MagWave Magnetic Level Gauge. Dual chamber level system K-TEK Products

ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

EAS822 (Contrac) Power Electronic Unit

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

Thermal overload relay TF65 and TF96

Manual motor starter MS116

Electronic overload relay EF65, EF96 and EF146

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

Mini contactors B6, BC6 with 3 pole

ZS6 Screw Clamp Terminal Blocks Feed-through

Manual motor starter MS116

Surge arrester POLIM-H..SD

Gas analyzers EL3060 The specialists for hazardous areas

SWC515 PinMount. Right the First Time Safe, Accurate, Service Friendly. SWC515 PinMount. Right the First Time

Manual motor starter MS132

LV Capacitors QCap-L series Capacitors for power factor correction

Manual motor starter MS132

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Manual motor starter MS132

ZS50-PE Screw Clamp Terminal Blocks Ground

PIN LOAD CELL TYPE PR

ZS10 Screw Clamp Terminal Blocks Feed-through

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

When grids get smart ABB your partner for developing Smart Grids solutions

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS4-PE Screw Clamp Terminal Blocks Ground

Surge arrester POLIM-C.. HD

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis Mass Flowmeter

TwinLine The new system of wall-mounting and floor-standing cabinets

ZS10-PE Screw Clamp Terminal Blocks Ground

RSD100 (Contrac) Electrical Linear Actuator

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ABB MEASUREMENT & ANALYTICS DATA SHEET series ph and Redox (ORP) industrial dip electrode systems

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

MB3600-HP10 Laboratory FT-NIR analyzer for hydrocarbon applications Pre-calibrated for blended gasoline, diesel, reformate and naphtha

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

MEDIUM VOLTAGE PRODUCT. KECA 80 D85 Current Sensor Instructions for installation, use and maintenance

Voltage limiting device HVL

Valve Blocks. For direct flanging to pressure and differential pressure transmitters. Drop-forging housing. Replaceable valve seat

SLB415 Load Cell. Global Usage No Compromise on Performance. SLB415 Beam Load Cells Cost Efficient Solution

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

Surge arrester POLIM-H.. ND

HLC A1... HLC B1... HLC F1...

2600T Series Pressure Transmitters Custom Linearization Table with ABB Asset Vision Basic

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

Manual motor starters Overview and benefits

ZX-Family Gas-insulated medium voltage switchgear

Model 6A Series 6-Axis Load Cells (Fx Fy Fz Mx My Mz)

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

Navigator 550 Sodium wet-section

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Voltage limiting device HVL

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

Manual motor starter magnetic only MO325

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZK4-PE PI-Spring Terminal Blocks Ground

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Transcription:

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET 9QGPS5500 Wire rope load cell

2 Measurement made easy Low cost load cell specially designed to measure the tension force on hoisting ropes. CE certified for hoisting applications Easy installation directly and without dismantling on the hoisting rope Very large range of measured loads on cable (from 0.25 up to 24 t) Very large range of cable suitable (available diameters 6 to 46 mm (0.24 to 1.81 inch)) Material: Nickel plated steel (also available in stainless steel) IP rating IP 65 Available options (non exhaustive list) ATEX intrinsic safety High service temperature 50 to 0 C ( 58 to 02 F) Amplified output (V or ma) Dual Wheatstone bridge

Change from one to two columns Applications Capacities The load cell 9QGPS5500 is perfectly designed to the following applications: Hoisting devices and crane's security in combination with a load limitation electronics (BRIDGEBOY, CRANEBOY, ) Specially designed to equip existing cranes 0.25 to 24 t (on the wire rope) Explosion protection (Option) ATEX intrinsic safety Ex II 1GD Ex ia IIC T6 or T4 Ga Ex ia IIIC T80 C Da Change from two to one column Specification 2 to 5 % Temperature coefficient of the sensitivity < ± 0.1 % F.S./10 C Temperature coefficient of zero signal < ± 0.1 % F.S./10 C Reference temperature 2 C (7.4 F) Temperature data Nominal temperature range 10 to 45 C (14 to 11 F) Service temperature range 25 to 70 C ( 1 to 8 F) Storage temperature range 50 to 85 C ( 58 to 5 F) Electrical data Input resistance 52 Ω ± 2 Ω Output resistance 52 Ω ± 2 Ω Insulation resistance (50 V) > 5000 MΩ Reference excitation voltage Nominal range of excitation voltage Nominal sensitivity 10 V to 12 V ± 1 mv/v* Load limits Safe load limit 200 % F.S. Breaking load > 00 % F.S. Permissible dynamic loading Table 1: (F.S.: full scale) * Can be different (according to the wire rope) Combined error depends on rope material and on site calibration Specifications subject to change without notice 70 % F.S.

4 Dimensions Load cell model 9QGPS5500 G (max) I J 20 L F (max) A M B C D F (max) R00057 Figure 1: Dimensions All specified dimensions are in mm Ref. Item Model Cable Ø mm Load t* ± A B C D Min - Nominal - Max 1TTSA** 1TTSI*** 6/9 to 10/ 0.25-0.8-1.2 E ±F G I J L M Torque NM CL Weight (Optimum) (m) mm (kg) 20 40 60 0 1 100 45 10 1.75 1TSA 1TSI*** 6/9 to 10/ 0.4-1.1-1.5 20 40 60 0 1 100 45 1.75 1SA 1SI*** 6/9 to 10/ 16 to 22 0.75-2 - 2.8 20 40 60 0 1 100 45 1.8 5 20 40 60 0 1 100 45 1.8 7 20 50 75 0 40 100 45 20 2.1 1A 1I*** 6/9 to 10/ 16 to 22 5500-C 2A 2I*** 14 to 28 1.6 -.5 2-5 - 5500-D A I*** 26 to 6 5.5-10 - 16 25 68 100 25 41 55 1 55 95 200 M16 25 6 4. 5500-E 4A 0 to 46 10 - - 24 5 75 1 26 46 70 116 55 110 20 M20 50 6 5.7 Table 2: * Other capacities and dimensions on request Table giving sensitivity and electronics limits for each cable diameter, available upon request ** 0nly in version 9QGPS5500J 4 to 20 ma, wires *** Stainless steel

5 All specified dimensions are in in. Ref. Item Model Cable Ø inch Load t* ±A B C D E Min - Nominal - Max 0.25-0.8 - ±F G I J L M inch 1.2 1.57 2.6 0.71 1. 1.22.94 1.77.5 6.0 M12 1.5 1.57 2.6 0.71 1. 1.22.94 1.77.5 6.0 M12 2-2.8 1TTSA** 1TTSI*** 0.24/0.5 to 0.9/0.59 1TSA 1TSI*** 0.24/0.5 to 0.9/0.59 0.4-1SA 1SI*** 0.24/0.5 to 0.9/0.59 0.6 to 0.87 0.75-1A 1I*** 0.24/0.5 to 0.9/0.59 0.6 to 0.87 5500-C 2A 2I*** 0.55 to 1.10 2-5 - 1.1-1.6 -.5-1.57 2.6 0.71 1. 1.22.94 1.77.5 6.0 M12 5 1.57 2.6 0.71 1. 1.22.94 1.77.5 6.0 M12 7 1.97 2.95 0.71 1. 1.57.94 1.77.5 6.0 M12 5500-D A I*** 1.02 to 1.42 5.5-10 - 16 0.98 2.78.94 0.98 1.61 2.17 4.5 2.17.74 5500-E 4A 1. to 1.81 10 - - 24 1.42 2.95 4.5 1.02 1.81 2.76 4.57 2.17 4. 9.06 M20 Table : 7.87 M16 Other capacities and dimensions on request Ref. Item Model Torque NM (Optimum) CL (ft) Weight (lb) 1TTSA** 1TTSI*** 10.86 1TSA 1TSI***.86 1SA 1SI***.97 500-A 1A 1I***.97 5500-C 2A 2I*** 20 4.6 5500-D A I*** 25 19.69 9.48 5500-E 4A 50 19.69 12.57 Table 4: * Other capacities and dimensions on request Table giving sensitivity and electronics limits for each cable diameter, available upon request ** 0nly in version 9QGPS5500J 4 to 20 ma, wires *** Stainless steel Wiring code - Exct. - Yellow (Jaune) + Sig. - Sig. + Green (Vert) + - White (Blanc) - + Exct. + Brown (Brun) + Standard: Cable screen not connected to transducer Faradisation non connectée au capteur Load direction Force Force R00081 Figure 2: Other views

26 Notes 9QGPS5500 9QGPS5500 WIRE WIRE ROPE ROPE LOAD LOAD CELL CELL DS/9QGPS5500-EN DS/9QGPS5500-ENREV. REV.AA Measurement made easy Low cost load cell specially designed to measure the tension force on hoisting ropes. CE certified for hoisting applications Easy installation directly and without dismantling on the hoisting rope Very large range of measured loads on cable (from 0.25 up to 24 t) Very large range of cable suitable (available diameters 6 to 46 mm (0.24 to 1.81 inch)) Material: Nickel plated steel (also available in stainless steel) IP rating IP 65 Available options (non exhaustive list) ATEX intrinsic safety High service temperature 50 to 0 C ( 58 to 02 F) Amplified output (V or ma) Dual Wheatstone bridge

7

ABB Automation GmbH Measurement & Analytics Force Measurement Oberhausener Str. 40472 Ratingen Germany Tel: +49 2102 12-2520 Fax: +49 2102 12-1414 Mail: ForceMeasurement@de.abb.com We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 20 ABB All rights reserved BDE701042 DS/9QGPS5500-EN Rev. A 02.20 abb.com/measurement