POWER. Improving Engine Utilization in DP Vessels

Similar documents
Fuel Efficient Power Plant Featuring Variable Speed Generation Systems for DP Drilling Units

DP INNOVATION. A Novel Solution to Common Mode Failures in DP Class 2 Power Plant

Appendix A. Power Management System Test Guidelines

Optimization of Power and Station Keeping Installations by a Total System Design Approach

Marine Technology Society

POWER SESSION. DP3 Class Power System Solutions for Dynamically Positioned Vessels

Kevin Duffin - Martime Assurance & Consulting John Flynn- Stena Drilling

Optimizing Energy Efficiency for DP Vessels for Variable Operational Risks

Alf Kåre Ådnanes; ABB BU Marine & Cranes, 2010-November Energy efficiency and fuel consumption of marine and offshore vessels Technical possibilities

Power Management Control of Electrical Propulsion Systems

RISK, FMEA AND RELIABILITY. Machinery System for DP Vessels with Increased Efficiency and Reliability

A Novel Solution to Common Mode Failures in DP Class 2 Power Plant

PSO project EaseWind Enhanced ancillary services from Wind Power Plants. Anca D. Hansen DTU Wind Energy

PARALLELING SWITCHGEAR

Wärtsilä HY TUG propulsion system

Basics of Paralleling

Wang Bin & Michael Ho, TIIAE Power management system

CATERPILLAR 3516B DP2 System

ASYN205B Central Synchronizing Controller

Alf Kåre Ådnanes Vice President Technology. A Concept of Environmentally Friendly Propulsion System

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

95 MW Wartsila Natural Gas Generator Power Plant

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Low Loss Concept Comparison Study

Standby Power Systems

DYNAMIC POSITIONING CONFERENCE October 13-14, 2015 THRUSTERS

DP Conference, Houston October 17-18, Challenges related to propulsion equipment and their interface to the Dynamic Positioning System

Control. Fuel Consumption and Emission Predictions Applications to a DP-FPSO Concept

T-Line Generator Control, Protection and Monitoring

Fishery Research Vessel Solea for Federal Office of Agriculture and Food

Automatic Genset Controller, AGC-3 Functional description Display unit and menu structure PID-controller Procedure for parameter setup Parameter list

Rental Power QSL9 series engine

THE GUIDELINE TO ELECTRIC PROPULSION

Development of Cloud-Based HILS for Performance Verification of LNGC PMS

ABB Softstarter Benefits Charnchanok Thongprad

SP4 DOCUMENTATION. 1. SP4 Reference manual SP4 console.

GENSET PRODUCTS 013 2

1800 KW / 2250 KVA POWERED by

640 KW / 800 KVA POWERED by

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

VLT AutomationDrive for marine winch applications

700 KVA / 550 KW POWERED by

Distributed Energy Resources

The Benefits of Podded Propulsion in the Offshore Market

Low Voltage Automatic Transfer Switch Systems

Advanced Genset Controller, AGC 200 Display readings Push-button functions Alarm handling Log list

WÄRTSILÄ DF: PRESENT AND FUTURE OF THE LNG FUELLED VESSELS

NERC Load Modeling Activities. Ryan D. Quint, PhD, PE Senior Engineer, System Analysis, NERC MRO Fall Reliability Conference November 2016

The Norwegian NOx Fund Experiences gained so far. Sveinung Oftedal

Ekip Link logic- zone discrimination protection system

MORE EFFICIENT DIESEL ELECTRIC POWER PLANT FOR DREDGES

Emergency Back-up Power Generation for Water & Wastewater Facilities

Diesel generator set QSL9 series engine

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Marine generators Proven generators for reliable power on board

Power Cables between Offshore Oil Platforms Viggo Bunæs page 130

Innovations in Offshore Drilling: Power and Drive Systems

From academia to industry Commercializing research on propulsion and hydrodynamics. Øyvind Smogeli Chief Operating Officer

TYPICAL AZIMUTH THRUSTER ARRANGEMENT

Frequency Inverters SJ Series Type P1

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Onboard DC Grid. Jan Fredrik DP Conference 2011; Houston. for enhanced DP operation in ships

DG SYNCHRONIZING &AMF PANEL

IEEE SESSION COMPUTER AIDED SMART POWER GRID

80 KW / 100 KVA POWERED by

MX431 Generator Automatic Voltage Regulator Operation Manual

Nirupa Chander, ABB Power Grids, All Energy Conference, Oct 2016 Grid Scale Energy Storage. How microgrids with storage & diesel create value

1000 KW / 1250 KVA POWERED by

Diesel generator set QSK95 series engine

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Diesel generator set QSK60 series engine

» IMPROVED EFFICIENCY» IMPROVED PRODUCTIVITY» POWER QUALITY» LOW-CARBON ENVIRONMENT.

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Setting Up an Oscillation Amplitude Sweep Test

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Options G4, G5 and G8 Power management Functional description Display units Power management setup Power management functions Parameter lists

Summary of Revision, IEEE C , Guide for Breaker Failure Protection of Power Circuit Breakers

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS

See Note. 100% of rated load

16 KW / 20 KVA POWERED by

ABB s new control and protection devices

HYBRID & LNG SOLUTIONS FOR FERRIES

See Note. 100% of rated load

See Note. 100% of rated load

MAN engines supporting Wind power EAPIC, Nairobi, 2 nd September 2010

Breakout Session 1 Report-out presentations

See Note. 100% of rated load

Texas A&M Microgrid and Electrical System Study. Cushing Memorial Library & Archives

MKN-DSP SERIES - THREE PHASE

Podded Propulsion Drive for Cruise Liner Seven Seas Voyager

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Rental Power KTA50 G3 series engine

Design Considerations for a Reference MVDC Power System

Electric Motor Controls BOMA Pre-Quiz

INDUSTRIAL GENERATOR SERVICE

COMPARISON OF ELECTRIC POWER AND PROPULSION PLANTS FOR LNG CARRIERS WITH DIFFERENT PROPULSION SYSTEMS

Transcription:

POWER Improving Engine Utilization in DP Vessels John J. May P.E., Transocean Offshore Deepwater Drilling, Inc. Session Chair Don Wilkes, GlobalSantaFe September 16-17, 2003 Houston, Texas

Improving Engine Utilization on DP Vessels

Series of Power Management System Modifications Frequency Sensitive - Thruster Drive Fast Phase Back Modify Load Dependent Start Table Auto Start - Handling of Different Size Generator Sets Add Low Pass Filter to Improve Synchronization Time Coordinate Engine Load Ramp with Availability of Power to DP Addition of Quick Trips to Improve Service Continuity Power System - More Robust - Blackout Resistant

Causes of Blackouts Short Circuits - protective devices programmed to isolate Overloads - PMS load dependent start/stop matrix Most severe - sudden loss of engine under load -Fuel system failures - (clogged fuel lines,fuel pump failure, water in fuel - mechanical failure (loss of oil pressure, over speed) - Control system failures (false activation lube oil pressure or oil mist detector, crankcase overpressure) Operator error - usually set up and/or synchronizing generators

Thruster Frequency Spillover Design - Major Components Engine/generator size and speed Thruster type/arrangement, size, and speed DP and power management system supplier Engine governor system and its response times Voltage regulation system and its response Systems must be tuned to work in harmony System testing is required Spillover is integral part of PMS

Operator Station Ethernet Switchboard Transducers Analog Signals (Hardwired) PMS Process Station DPC Ethernet Thruster Process Station Other Thruster Process Stations Analog Signal (Hardwired) Time delay = 1-2 seconds P L C Thruster Control Figure 1 - Thruster Load Limit Delay

Operator Station Switchboard Transducers Analog Signals (Hardwired) PMS Process Station Ethernet DPC Ethernet Thruster Process Station Other Thruster Process Stations Current Limit Control (fast) Analog Signal (Hardwired) P L C Thruster Control 110V Buss Volt / Freq Figure 2 - Frequency Sensitive Power Phase Back

Supply Frequency %Supply frequency Limit 100 80 60 40 20 0 54 54.5 55 55.5 56 56.5 57 57.5 58 58.5 59 59.5 60 Supply Frequency Figure 3 - Initial Phase Back Current Limit

Frequency Sensitive - Fast Phase Back Logic Diagram

HARMONIC FILTER 7MW 1D 4.7MW 2B 7MW 1C 7MW 4.7MW 7MW 1B 2A 1A HARMONIC FILTER SWBD PORT 11KV SWBD STBD 11KV DRILLING 480V SWBD AFT PORT 480V SWBD AFT STBD DRILLING 4.3MW EG E D B THRUSTERS A C F THRUSTERS 480V SWBD EMCY AFT 120V SYSTEM 480V SWBD FWD PORT 480V SWBD FWD STBD Discovery Enterprise EMCY 120V SYSTEM One Line Diagram FWD 120V SYSTEM

Testing of Spillover Tests the Power Management System Loss of on-line generator set (FMEA) PMS must manage loads Modify Load Dependent Start Table Worst case is 2 generator operation with the loss of 1 unit Remaining generator must carry 200% of its initial load Test system overload capability - failure is blackout System must be stable enough to synchronize additional generators

Load Dependent Start Table - Initial Number of Start 1 Start 2 Generators Load Time Load Time 2 55 10 100 2 3 68 10 100 2 4 80 10 100 2 5 84 10 100 2 Figure 5 - Initial Enterprise Load Dependent Start Table

Figure 6 - Engine Response to Step Load Changes

Engines System Engine Remaining Overload Overload Overload Overload On-Line Capacity Loss System Capability Capability Capability Capability MW MW MW Capacity 110% 140% 150% 160% 2 Engine/Generator Sets 2-4.7 9.4 4.7 4.7 55% 70% 75% 80% 1-4.7 & 1-7.0 11.7 4.7 7.0 66% 84% 90% 96% 1-4.7 & 1-7.0 11.7 7.0 4.7 44% 56% 60% 64% 2-7.0 14.0 7.0 7.0 55% 70% 75% 80% 3 Engine/Generator Sets 2-4.7 & 1-7.0 16.4 4.7 13.7 92% 117% 125% 134% 2-4.7 & 1-7.0 16.4 7.0 9.4 63% 80% 86% 92% 1-4.7 & 2-7.0 18.7 4.7 14.0 82% 105% 112% 120% 1-4.7 & 2-7.0 18.7 7.0 11.7 69% 88% 94% 100% 3-7.0 21.0 7.0 14.0 73% 93% 100% 107% 4 Engine/Generator Sets 2-4.7 & 2-7.0 23.4 4.7 18.7 88% 112% 120% 128% 2-4.7 & 2-7.0 23.4 7.0 16.4 77% 98% 105% 112% 1-4.7 & 3-7.0 25.7 4.7 21.0 90% 114% 123% 131% 1-4.7 & 3-7.0 25.7 7.0 18.7 80% 102% 109% 116% 4-7.0 28.0 7.0 21.0 83% 105% 113% 120% 5 Engine Generator Sets 2-4.7 & 3-7.0 30.4 4.7 25.7 93% 118% 127% 135% 2-4.7 & 3-7.0 30.4 7.0 23.4 85% 108% 115% 123% 1-4.7 & 4-7.0 32.7 4.7 28.0 94% 120% 128% 137% 1-4.7 & 4-7.0 32.7 7.0 25.7 86% 110% 118% 126% 5-7.0 35.0 7.0 28.0 88% 112% 120% 128% = Minimum Figure 7 - Load Dependent Start Worksheet

Load Dependent Start Table - After FSO Number of Start 1 Start 2 Generators Load Time Load Time 2 65 90 70 2 3 72 90 80 2 4 80 90 85 2 5 84 90 90 2 Two Engine Operation - Large and Small Engine - At 60% load for 30 second a standby start will be initiated. - For short time load Dependent Start see table above (I.e. 70 % - 2 sec.) Figure 8 - Load Dependent Stat Table - After FSO

7MW & 4.7MW ll with 55% Load 137% Load on 4.7MW Gen Figure 9 - Discovery Deep Seas Test C11 FSO starts: 270ms Simrad reacts: 4.18 sec Simrad Controls 6.2 sec

2-7MW Gens ll with 60% Load 120% Load on 7MW Gen Figure 10 - Discovery Deep Seas Test C18 FSO starts:.343 sec Simrad reacts: 3.90 sec Simrad controls: 4.95 sec

2-7MW Gens ll with 55% Load kw oscillation 1.2MW with 18 sec period Figure 11 - Discovery Enterprise Test Thrusters: Manual Control FSO program regulates thruster kw

Bus Ties Open - DP Control Figure 12 - Discovery Spirit Test Gen 1C is tripped and after 90 sec re-synchronized with Gen 1D

Low Pass Filter on Thruster Speed Reference Parallel 1C in 90 sec Figure 13 - Discovery Enterprise Test 7MW & 4.7MW ll with 60%Load 150% Load on 4.7MW Gen

4.00 3.50 Engines per Day 3.00 2.50 2.00 1.50 1.00 40 41 42 43 44 45 46 47 48 49 50 51 52 1 2 3 4 5 6 7 Time - Weeks 2002-2003 Discovery Enterprise Discovery Spirit Discovery Deep Seas Figure 14 - Enterprise Class Engine Hour Summary

Wartsila Emission Report CO emissions are reduced by 42 tons/year; a 59% reduction CO2 emissions are reduced by 491 tons/year; a 1.5% reduction Fuel Consumption decreased by 246 tons/year; a 2.5% reduction Particulate matter reduced by 5 tons/year; - a 15% reduction THC emissions are reduced by 15 tons/year; a 25% reduction SOx emissions are proportional to kw; therefore, no difference NOx emissions are increased to 39 tons/year; an 8 % increase

The improved engine utilization on each Enterprise vessels because of the of FSO and PSM modifications have yielded the following benefits: Engine hours reduced by more than 25% Fuel reduction ~ 10% ~ 300,000 gallons/year Lube Oil consumption cut in half Overall emissions are reduced Engine maintenance and parts reduction ~ $50,000/year Related maintenance labor and parts ~ $150,000/year

Figure 15 - Express Class - Power System One Line Diagram

FSO Current Clamp 62 hz Voltage Frequency Power DP Reference Current 140% Load 55.2 hz Figure 16 - Cajun Express FSO Test

Series of Power Management System Modifications Frequency Sensitive - Thruster Drive Fast Phase Back Modify Load Dependent Start Table Auto Start - Handling of Different Size Generator Sets Add Low Pass Filter to Improve Synchronization Time Coordinate Engine Load Ramp with Availability of Power to DP Addition of Quick Trips to Improve Service Continuity Power System - More Robust - Blackout Resistant