Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Similar documents
Installing a PTV Inlet

Switching DC Power Supply

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Installing a PTV Inlet

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

Triple Output Power Supply

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

Installation and Service Manual On-Highway Stabilization System

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

»Product» Safety Warning

Galaxy 300 Battery Breaker Kit G3HTBKIT1

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual

AUTO CHARGE D PUMP PLUS

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installing an Auxiliary Pressure Control Module

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Nickel Catalyst Tube Accessory 19205A

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

AGM Series. Installation Manual AGM Series Modular Battery Systems

WATERFLUX 3070 Quick Start

OPERATOR PROTECTIVE EQUIPMENT. Owner s Responsibility

KIT # MC-2911, MC-2923 FOR ALL YEAR SUZUKI M-109R SERIES

INSTALLATION INSTRUCTIONS SEMI-HIDDEN WINCH MOUNT Part Number:70005 Application: Ford Super Duty

GPS AutoSteer System Installation Manual

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

"Engineered to Ride, Built to Last "

TECHNICAL INSTRUCTIONS

Fiber Splice Panel Rack Mount User Manual

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

KIT # MC-3104 FOR HARLEY DAVIDSON DYNA SERIES

Instructions for 2-row monitoring only

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

Instructions for 2-row monitoring only

Galaxy VM. Battery Breaker Box Installation 09/

Environmental Distribution Center (EDC-06P-NH)

2-row and All-row systems included.

On all settings above 100 horsepower the following precautions should be observed:

160S Rewind Option Kit Installation Instructions

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

KIT # MC-2992, MC-2993 INDIAN SCOUT SERIES W/ ABS 2014-PRESENT

PNEUMATIC SLIDING VALVE

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

Installing Power Components

Installing the Flame Ionization Detector EPC Flow Control Manifold

VERSAFLOW MAG 4000 Quick Start

Valve Box and Valve Accessories G4315A, G4316A, G4317A

BATTERY SAVER LOW RIPPLE HO

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Installing a Purged Packed (PP) Inlet

GPS AutoSteer System Installation Manual

INSTALLATION INSTRUCTIONS

ELECTRIC START KIT KIT P/N

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

FD 120 Card Cutter MAINTENANCE MANUAL. MyBinding.com 5500 NE Moore Court Hillsboro, OR Toll Free: Local: /2011

Installation Instructions Electric Heaters 5 20 kw

Installing a Cool On-Column Inlet

Max IV Rear Axle Replacement For models after Serial Number and all rear splined axle replacements.

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Installation Instructions

SCION tc 2014 FOG LIGHT KIT

A1062 & A1072 AUGER ASSEMBLY MANUAL. Read & understand all instructions pertaining to this auger prior to use!

READ ME! IMPORTANT WARNING! ENG. Auxiliary 80l Fuel Tank Toyota Hilux DC 2005-Current

Installation Instructions Electric Heaters 5 20 kw

Model 1672, 1673 Triple Output Power Supply

RANGER 900 POWER STEERING KIT

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

ME217PIB / ME503PIB SMART INTERLOCK TECHNOLOGY ACME ADAPTER INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

DEALER SETUP INSTRUCTION

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

CONSOLE MANAGEMENT CONTROLLER

Sentry Battery Charger. Installation and Operations Manual Section 75

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Before equipment use, please read this operation manual carefully. Serial Number: Date Purchased:

Installation and Operation

Installing an Auxiliary Pressure Control Module

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

PRODIGY & PRO PLUS Skid Steer Snowplows

GPS AutoSteer System Installation Manual

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

IMPORTANT SAFEGUARDS

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Installation Instructions

Installing the CO 2 Cryogenic Oven Cooling Kit

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

EXTRA LARGE OUTDOOR HOUSINGS

VISOR AUDIO KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Transcription:

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5 Installation Manual

ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTIONS Document Information Identification Alcatel-Lucent DC Metro Cell AWS (B4) Installation Instructions 1000023159 Rev 01 7/14 ii

ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTION Before You Begin How to Get Assistance If you need help with your Alcatel-Lucent products, contact one of our TAC Engineers at 866-582-3688. Packaging Inspection If the shipping container shows evidence of rough handling, inspect the equipment carefully for shipping damage. If damage is found, notify the carrier immediately, and annotate the damage on the bill of lading. Product Summary The Alcatel-Lucent DC Metro Cell kit provides parts and instructions to field-install the second DC Metro Cell in an MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, or MC-DBR5 cabinet. For Use With This document is intended for use with the Alcatel-Lucent DC Metro Cell AWS (B4) Field-installed Kit, PN 3MV00489AC. Associated Documentation Name Part Number Alcatel-Lucent 7310 Metro Cell Cabinet Installation Manual 1000021514 Alcatel-Lucent 7310 Metro Cell Cabinet Installation Manual 1000023131 Revision History Revision ECO Description of Change Approvals 00 Original release. 3/12/14. ME M.S. 01 Customer redlines; clarified SAR-W port information; added information to re-secure MC and SAR-W to bracket; added MC-DBR2 RF cable installation information and references to MC-DBR4 and MC-DBR5. 7/28/14. EE PM ME EE PM M.B. E.B. M.S. M.B. E.B. iii

ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTIONS Warnings and Cautions This cabinet and its equipment might not be suitable for use in corrosive environments that can be present in agricultural buildings. See NEC 547 or CEC 2-400. Your equipment may be damaged and the warranty voided if: Components (including cables and equipment) are connected or disconnected while power is applied to them Incorrect wire connections are made Battery polarity is reversed Battery voltage rating is too high The following precautions must be observed during all phases of installing an ALP cabinet and equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual risks personal injury and violates safety standards of design, manufacture, and intended use of the equipment. Alcatel-Lucent is not responsible for any equipment damage or poor operating performance when these guidelines are not followed or when noncertified installers perform the work. Type of Precaution Precaution General Safety Observe all general safety precautions against personal injury and equipment damage. Keep bystanders away. Ensure all site personnel know emergency procedures in case of an injury and the location of the first-aid kit. Codes The procedures in this manual are only recommended guidelines. Follow all national and local electrical codes. Security Never leave the cabinet unattended. When leaving the site, close and secure the cabinet. Service Personnel It is safe to have a second person assist when servicing or adjusting internal parts. Electrical Proper Ground The equipment must be connected to an electrical ground to minimize shock hazard. Consult NFPA 70 (NEC) and local codes for grounding requirements. Explosive Atmosphere Do not operate the equipment in the presence of flammable gases, fumes, or dust. Operation of this equipment in such an environment constitutes a safety hazard. Live Circuits Operation personnel must not remove equipment covers or panels. Component replacement and internal adjustments must be made only by qualified maintenance personnel. Do not replace components with power applied. To avoid injuries, always disconnect power and allow the circuit to discharge before performing repair procedures. Lightning Storms Do not service or repair equipment during a lightning storm. Voltage Detector Always use a noncontact voltage detector when approaching a cabinet to verify there are no leaks or shorts on the external body. iv

ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTION Type of Precaution Precaution Equipment General Follow manufacturer s recommended mounting, installation, and operation procedures to ensure proper equipment operation, avoid damage, and maintain warranty. In most cases, a certified installer for such equipment is required. Conform to jurisdictional codes and construction covenants. Removing Components Remove individual components only after power is disconnected. This includes both AC line power and backup battery power. Specifications The equipment is designed to operate within specified design parameters. Do not exceed the specifications. Substituting Parts or Making Modifications Do not install substitute parts or perform any modifications to factory-installed equipment without permission from Alcatel-Lucent. Moving Cabinet Factor in the combined weight of all materials in the cabinet before engineering a lifting apparatus; consult a site engineer to verify adequate support. Ensure the doors are closed before the cabinet is lifted. Do not lift the cabinet with optional equipment or batteries installed. The cabinet may bend from excessive weight. If the batteries are damaged, a potentially hazardous material spill may occur. Follow any moving instructions from the manufacturer of installed equipment. These may include not installing the equipment until the cabinet is mounted. This manual contains safety labels in the form of DANGER, WARNING, and CAUTION. The labels generic here but specific in the manual have the following definitions. DANGER: Danger indicates that the described activity or situation may result in serious personal injury or death; for example, high voltage or electric shock hazards. WARNING: Warning indicates that the described activity or situation may, or will, cause equipment damage or serious performance problems. CAUTION: Caution indicates that the described activity or situation may, or will, cause service interruption. The safety alert symbol is used on product labels and in this guide to alert the user to important operating and maintenance instructions. v

ALCATEL-LUCENT DC METRO CELL AWS (B4) KIT INSTALLATION INSTRUCTIONS Notes vi

Introduction These instructions describe how to install a DC Metro Cell AWS (B4) into the 7310 Metro Cell (MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, and MC-DBR5) cabinet. MCO#1 SAR-W AWS (B4) Rear Bracket Assembly Handle DC Metro Cell Access Cover Shot-protector Bracket Front Bracket Spacer Bracket (for use with 7310-MC DBR1) Table of Contents Kit Contents, page 2 DC Metro Cell AWS (B4) assembly, page 3 MC-DBR1, MC-DBR3, or MC-DBR4 installation, page 8 MC-DBR2 or MC-DBR5 installation, page 19 1

Kit Contents (1) Front bracket (5) M5x10mm screws (1) Rear bracket assembly (2) M6x16mm hex bolts (1) Shot-protector bracket (2) M6 split-lock washers (1) Handle (2) M8 30mm hex bolts (1) GPS cable (2) M8 14mm hex bolts (1) Power cable (4) M8 split-lock washers (1) Fiber cable (2) M8 flat washers (1) Tether with detachable link (2) 12-24 self-tapping screws (1) Spacer bracket (2) 10-32 screws (2) 5.3mm plugs (2) #10 split-lock washers (1) Locking nut (1) 3/8-16 3 1/2-in. hex bolt (1) Gland assembly (body, sealing gland, compression nut) (1) 3/8-in. split-lock washer (1) MCO#2 front antenna cable (PN 4000013492, MC-DBR1, MC-DBR3, or MC-DBR4) (1) MCO#2 front antenna cable (PN 4000014441, MC-DBR2 or MC-DBR5) (1) MCO#2 rear antenna cable (PN 4000013489 MC-DBR1, MC-DBR3, or MC-DBR4) (20) 8-in. cable ties (1) MCO#2 rear antenna cable (PN 4000014442, MC-DBR2 or MC-DBR5) Tools and Materials Required DC Metro Cell Standard tools T20 and T25 Torx bit screwdrivers Medium-strength thread-lock ESD wrist strap Oxide-inhibiting, electrically-conductive grease 2

Precautions DANGER Cabinet and equipment must be grounded to minimize shock hazard. Follow national and local codes, and best practices. Wear appropriate personal protection equipment, and follow safe electrical work practices. See NFPA 70E. Do not install equipment showing any physical damage. Reattach all devices, doors, and covers before switching on power to the cabinet. Failure to follow these precautions will result in death or serious injury! Threat Releases The on-site technician is responsible for acquiring threat releases before work begins. Neither Alcatel-Lucent nor its representatives will start any work without site management approval. Assemble the DC Metro Cell AWS (B4) To assemble the DC Metro Cell AWS (B4) 1 Install the front bracket onto the DC Metro Cell. Apply medium strength thread-lock to the screw threads. Secure the front bracket to the DC Metro Cell with (2) M8 30mm hex bolts, (2) M8 split-lock washers, (2) M8 flat washers, and (3) M5x10mm screws. Torque screws first to 25 in-lb. Torque bolts second to 40 in-lb. Screw Bolt, Split-lock Washer, Flat Washer DC Metro Cell Bolt, Split-lock Washer, Flat Washer Front Bracket Screws 3

2 Install the rear bracket assembly onto the DC Metro Cell. Secure the rear bracket assembly to the DC Metro Cell with (2) M8 14mm hex bolts and (2) M8 split-lock washers. Torque hardware to 40 in-lb. Rear Bracket Assembly Bolts and Split-lock Washers DC Metro Cell 3 Install the shot-protector bracket onto the DC Metro Cell. Secure the shot-protector bracket to the DC Metro Cell with (2) M5x10mm screws. Torque to 25 in-lb. Note Install spacer bracket onto the front bracket on model 7310 MC-DBR1. Secure with shot-protector bracket hardware and torque as listed above. DC Metro Cell Shot-protector Bracket Front Bracket Spacer Bracket (optional) 4

4 Install the handle onto the front bracket. Secure the handle to the front bracket with (2) 10-32 screws and (2) #10 split-lock washers. Torque to 25 in-lb. Screw Handle Screw Front Bracket 5 Use a T25 Torx bit screwdriver to loosen the 3 Torx screws on the DC Metro Cell access cover. Open the access cover. Remove and discard the knock-out assembly illustrated below. Access Cover Torx Screws Knock-out Assembly 5

6 Locate the gland assembly in the kit. Remove the compression nut and sealing gland from the gland body. Set the sealing gland and compression nut aside. Install the gland body into the knock-out hole from the outside. Secure the gland body to the DC Metro Cell with (1) locking nut. Torque to 10 ft-lb. Gland Assembly Gland Sealing Compression Body Gland Nut Locking Nut (Inside DC Metro Cell) ASM Gland Body DC Metro Cell 7 Route the fiber cable through the compression nut. Install the sealing gland onto the fiber cable. Install (2) 5.3mm plugs into the empty holes in the sealing gland. Note Ensure the 5.3mm plugs are fitted and level with the sealing gland surface 5.3mm Plugs Heat Shrink Sealing Gland Compression Nut 5.3mm Plugs Level with Sealing Gland Surface 6

8 Route the fiber cable through the gland body into the DC Metro Cell. Remove and discard the 2 fiber contact covers to expose the fiber contacts. Install the fiber cable connector into the SX SFP module. Important Do not touch the fiber contacts. Inspect the fiber cable end and carefully clean if necessary. Fiber Contact Covers Fiber Cable Fiber Cable SX SFP Module Fiber Contacts Gland Body 9 Install the sealing gland into the gland body. Secure the sealing gland in the gland body by tightening the compression nut with a tool until the sealing gland compresses slightly. Note The fiber cable should not move in the sealing gland. If it does, tighten the compression nut a little more. Sealing Gland in Gland Assembly (View from Below) Compression Nut 7

10 Close the DC Metro Cell access cover. Use a T25 Torx bit screwdriver to secure the access cover with the 3 Torx screws. Torque to 25 in-lb. Access Cover Torx Screws MC-DBR1, MC-DBR3, or MC-DBR4 Installation (for use with RF cable PNs 4000013492 and 4000013489) To connect the RF cables 1 Open the rectifier door and then open equipment cabinet door. 2 Remove the 7/16-in. DIN terminators from the diplexer and the N-type terminator from the GPS splitter. GPS Splitter Diplexer Terminators Removed at Circled Locations 8

3 Install the MCO#2 rear antenna cable (PN 4000013489) onto the diplexer port (labelled 1710-2200MHz) as illustrated. Torque to 20 ft-lb. Note Ensure rear antenna cable is positioned downward as illustrated. 1710-2200MHz Diplexer Port Diplexer MCO#2 Rear Antenna Cable (4000013489) 4 Install the MCO#2 front antenna cable (PN 4000013492) onto the diplexer port (labelled 1710-2200MHz) as illustrated. Torque to 20 ft-lb. Note Ensure front antenna cable is positioned downward as illustrated. 1710-2200MHz Diplexer Port MCO#2 Front Antenna Cable (4000013492) Diplexer 9

5 Secure both MCO#2 antenna cables with (4) 8-in. cable ties as illustrated. Important Ensure cables are not kinked or twisted. Do not bend the cable within 2 in. of the DC Metro Cell connector. The bend radius must not be less than 1 in. MCO#2 Front Antenna Cable MCO#2 Rear Antenna Cable Cable Ties Circled 6 If installed, remove the AWS (B4) fuse from position 3 on the rectifier front panel. Note It is not necessary to turn off cabinet power to install the AWS (B4) kit. Position Fuse Value Equipment 1 7.5A MCO#1 2 5A SAR-W 3 7.5A AWS (B4) 4 1.5A NID (External) 5 - Unused 6 - Unused 7 Locate the MCO#2 power feed in-line connector. 8 Remove the compression nut and tube. 9 Cut the power cable to desired length. Plug MCO#2 Compression Nut Tube Label Identifying MCO#2 10

10 Remove the sealing plug from the in-line connector and discard. 11 Reinstall the compression nit and tube onto the cable as illustrated below. 12 Insert the power cable through the nut, selected seal(s), and tube. 13 Install the electrical connections onto the screw terminal block. Torque the screws to 5 in-lb. Seals RED (L) is -48VDC BLACK (N) is RETURN Screw Terminal Block ELECTRICAL CONNECTIONS BLACK (N) RETURN RED (L) -48VDC N N/A 0.300 0.800 L 14 Reassemble the in-line connector. Note Ensure the assembly is tightened to 22 in-lb to provide a good cable entry seal. In-line Connector 11

15 Secure the power cable to the lance on the rear of the hinge pin bracket with 1 cable tie. Lance Cable Tie Power Cable Hinge Pin Bracket Install the DC Metro Cell To install the DC Metro Cell 1 Install the tether onto the tether bracket. Secure the tether to the tether bracket with (1) (3/8-16) 3 1/2-in. hex bolt and (1) 3/8-in. split-lock washer. Hand-tighten the bolt with a tool until the split-lock washer compresses. Bolt Split-lock Washer Tether Bracket Tether 12

2 Feed the MCO#2 antenna cables through the front bracket opening from the rear of the DC Metro Cell. Front Bracket Opening View from Front MCO#2 Antenna Cables 3 Install the DC Metro Cell onto the hinge pin. Secure the DC Metro Cell to the hinge pin with (2) 12-24 self-tapping screws as illustrated. Torque 25 in-lb. DC Metro Cell Hinge Pin Screws 13

4 Install the tether link and tether onto the rear bracket. Apply medium-strength thread-lock to tether link threads. Torque to 25 in-lb. Tether DC Metro Cell Tether Link Rear Bracket 5 Install the MCO#2 antenna cables onto the top of the DC Metro Cell as illustrated. Torque MCO#2 antenna cable connectors to 20 ft-lb. MCO#2 Rear Antenna Cable (4000013489) MCO#2 Front Antenna Cable (4000013492) DC Metro Cell 14

6 Secure the antenna cables to the handle and lances with (4) 8-in. cable ties as illustrated. Important Ensure the cables are not kinked or twisted. Do not bend the cable within 2 in. of the DC Metro Cell connector. The bend radius must not be less than 1 in. Handle (under antenna cables) Lances 7 Install the GPS cable onto the top of the DC Metro Cell. Torque the GPS cable connector to 20 in-lb. DC Metro Cell (top) GPS Cable 15

8 Secure the GPS cable to handle, lances, and antenna cables with (4) 8-in. cable ties and feed through the front bracket opening as illustrated. Important Ensure cables are not kinked or twisted. Do not bend the cable within 2 in. of the DC Metro Cell connector. The bend radius must not be less than 1 in. Handle Lances GPS Cable Front Bracket Opening 9 Install GPS cable connector onto the splitter as illustrated. Torque to 20 in-lb. Secure the GPS cable to the other cables with (3) 8-in. cable ties as illustrated. GPS Cable Connector Splitter Cable Ties 3rd cable tie not shown 16

10 Carefully cut the cable ties securing the MCO#2 ground cable to the rear of the hinge pin bracket. Apply oxide-inhibiting, electrically-conductive grease to the flat side of the ground cable lug. Install the ground cable onto the rear of the DC Metro Cell as illustrated. Secure the ground cable to the DC Metro Cell with (2) M6x16mm hex bolts and (2) M6 split-lock washers. Torque to 40 in-lb. Ground Cable Bolts and Washers Hinge Pin Bracket Ground Cable Cable Ties 11 Install the power cable onto the DC Metro Cell as illustrated. DC Metro Cell Power Cable 17

12 Remove the cover from Port 2 (SFP) on the bottom of the SAR-W. Install the fiber cable into Port 2. Secure the FullAXS gland to the SAR-W. SAR-W Ports (view from rear) DC AC SAR-W (view from rear) 5 4 3 FullAXS Gland Port 2 (SFP) 2 Fiber Cable 1 13 Reinsert the fuse into location 3 on the rectifier front panel. WARNING The cabinets and cables are live once the 48VDC power is applied. 14 Commission the DC Metro Cell AWS (B4) per the instructions in the cabinet installation manual (PN 1000021514 or 1000023131). 15 Return the DC Metro Cell AWS (B4) and SAR-W to their upright position. 16 Use a 3/16-in. Allen wrench to hand-tighten the hardware securing the DC Metro Cell AWS (B4) and SAR-W rear-equipment mounting brackets to the cabinet. Rear Equipment Mounting Brackets SAR-W DC Metro Cell AWS (B4) 17 Installation is complete. 18

MC-DBR2 or MC-DBR5 Installation (for use with RF cable PNs 4000014441 and 4000014442) To connect the RF cables 1 Remove the protective cap, nut, flat washer, and o-ring (if present) from both MCO#2 antenna cable bulkhead connectors. Retain the protective cap, nuts, and washers; discard the o-ring. MCO#2 Antenna Cable Bulkhead Connector O-ring Nut Protective Cap Flat Washer 2 Install the MCO#2 front (PN 4000014441) and rear (PN 4000014442) antenna cable bulkhead connectors into the upper and lower openings in the cabinet as illustrated. Secure each cable with a nut and washer on the outside of the cabinet. Torque to 10 ft-lb. Important Align the flat edges on the bulkhead connector with the flat edges of the cabinet opening so the DC Metro Cell connector on the opposite end faces up as illustrated. MCO#2 Front Antenna Cable (4000014441) Bulkhead Connector MCO#2 Rear Antenna Cable (4000014442) Flat Sides Flat Sides DC Metro Cell Connector Facing Up 19

3 Reinstall the protector caps onto the bulkhead connectors outside the cabinet. Cabinet Rear Protector Caps (Nuts and Washers Underneath) 4 If installed, remove the AWS (B4) fuse from position 3 on the rectifier front panel. Note It is not necessary to turn off cabinet power to install the AWS (B4) kit. Position Fuse Value Equipment 1 7.5A MCO#1 2 5A SAR-W 3 7.5A AWS (B4) 4 1.5A NID (External) 5 - Unused 6 - Unused 5 Locate the MCO#2 power feed in-line connector. 6 Remove the compression nut and tube. 7 Cut the power cable to desired length. Plug MCO#2 Compression Label Identifying Tube Nut MCO#2 8 Remove the sealing plug from the in-line connector and discard. 9 Reinstall the compression nit and tube onto the cable as illustrated below. Seals Screw Terminal Block 20

10 Insert the power cable through the nut, selected seal(s), and tube. 11 Install the electrical connections onto the screw terminal block. Torque the screws to 5 in-lb. RED (L) is -48VDC BLACK (N) is RETURN ELECTRICAL CONNECTIONS BLACK (N) RETURN RED (L) -48VDC N N/A 0.300 0.800 L 12 Reassemble the in-line connector. Note Ensure the assembly is tightened to 22 in-lb to provide a good cable entry seal. In-line Connector 13 Secure the power cable to the lance on the rear of the hinge pin bracket with 1 cable tie. Lance Cable Tie Power Cable Hinge Pin Bracket 21

Install the DC Metro Cell To install the DC Metro Cell 1 Install the tether onto the tether bracket. Secure the tether to the tether bracket with (1) 3/8-16 3 1/2-in. hex bolt and (1) 3/8-in. split-lock washer. Hand-tighten the bolt until the split-lock washer compresses. Bolt Split-lock Washer Tether Bracket Tether 2 Feed the MCO#2 antenna cables through the front bracket opening from the rear of the DC Metro Cell. Front Bracket View from Front MCO#2 Antenna Cables 22

3 Install the DC Metro Cell onto the hinge pin. Secure the DC Metro Cell to the hinge pin with (2) 12-24 self-tapping screws as illustrated. Torque 25 in-lb. DC Metro Cell Hinge Pin Screws 4 Install the tether link and tether onto the rear bracket. Apply medium-strength thread-lock to tether link threads. Torque to 25 in-lb. Tether DC Metro Cell Tether Link Rear Bracket 23

5 Install the MCO#2 rear antenna cable (4000014442) onto the rear DC Metro Cell connector as illustrated. Finger-tighten; cable will be torqued at a later step. MCO#2 Rear Antenna Cable (4000014442) Rear DC Metro Cell Connector 6 Carefully bend the front MCO#2 antenna cable (4000014441) as illustrated. Important Ensure the cable is not kinked or twisted. Do not bend the cable within 2 in. of the DC Metro Cell connector. The bend radius must not be less than 1 in. 1 Radius Do not Bend within 2 of Connector MCO#2 Front Antenna Cable (4000014441) 24

7 Install the MCO#2 front antenna cable (4000014441) onto the front DC Metro Cell connector as illustrated. Finger-tighten; cable will be torqued in a later step. MCO#2 Front Antenna Cable (4000014441) Front DC Metro Cell Connector 8 Secure both MCO#2 antenna cables to the Metro Cell handle lances with 4 cable ties. Handle Cable Ties MCO#2 Antenna Cables Lance Cable Ties DC Metro Cell 25

9 Torque the MCO#2 antenna cable connectors to 20 ft-lb. MCO#2 Antenna Cable Connector MCO#2 Antenna Cable Connector 10 Secure the MCO#2 front antenna cable to the MCO#2 rear antenna cable with 1 cable tie as illustrated. MCO#2 Front Antenna Cable MCO#2 Rear Antenna Cable Cable Tie 26

11 Install the GPS cable connector onto the Metro Cell as illustrated. Torque to 20 in-lb. GPS Cable Connector 12 Feed the GPS cable through the Metro Cell opening. GPS Cable DC Metro Cell Opening 27

13 Install the GPS cable connector onto the splitter as illustrated. Torque to 20 in-lb. Secure the GPS cable to the other cables with (3) 8-in. cable ties as illustrated. GPS Cable Connector Splitter Note: 2nd and 3rd cable ties not shown Cable Tie 14 Secure the GPS cable to the Metro Cell handle, lances, and antenna cables with (4) 8-in. cable ties and feed through the front bracket opening as illustrated. Important Ensure cables are not kinked or twisted. Do not bend the cable within 2 in. of the DC Metro Cell connector. The bend radius must not be less than 1 in. Handle GPS Cable Lance Cable Ties Front Bracket Opening 28

15 Carefully cut the cable ties securing the MCO#2 ground cable to the rear of the hinge pin bracket. Apply oxide-inhibiting, electrically-conductive grease to the flat side of the ground cable lug. Install the ground cable onto the rear of the DC Metro Cell as illustrated. Secure the ground cable to the DC Metro Cell with (2) M6x16mm hex bolts and (2) M6 split-lock washers. Torque to 40 in-lb. Ground Cable Bolts and Washers Hinge Pin Bracket Ground Cable Cable Ties 16 Install the power cable onto the DC Metro Cell as illustrated. DC Metro Cell Power Cable 29

17 Remove the cover from Port 2 (SFP) on the bottom of the SAR-W. Install the fiber cable into Port 2. Secure the FullAXS gland to the SAR-W. SAR-W Ports (view from rear) DC AC SAR-W (view from rear) 5 4 3 FullAXS Gland Port 2 (SFP) 2 1 Fiber Cable Installed 18 Reinsert the fuse into location 3 on the rectifier front panel. WARNING The cabinets and cables are live once the 48VDC power is applied. 19 Commission the DC Metro Cell AWS (B4) per the instructions in the cabinet installation manual (PN 1000021514 or 1000023131). 20 Return the DC Metro Cell AWS (B4) and SAR-W to their upright position. 21 Use a 3/16-in. Allen wrench to hand-tighten the hardware securing the DC Metro Cell AWS (B4) and SAR-W rear-equipment mounting brackets to the cabinet. Rear Equipment Mounting Brackets SAR-W DC Metro Cell AWS (B4) 22 Installation is complete. 30